SIST EN 13600:2004
(Main)Copper and copper alloys - Seamless copper tubes for electrical purposes
Copper and copper alloys - Seamless copper tubes for electrical purposes
This European Standard specifies the composition, property requirements including electrical properties, and
tolerances on dimensions and form for seamless drawn copper tubes for electrical purposes, delivered in straight
lengths with the cross-sections and size ranges below:
for round tubes with outside diameters from 5 mm up to and including 150 mm and wall thicknesses from
0,5 mm up to and including 20 mm;
for square and rectangular tubes with major outside dimension from 5 mm up to and including 150 mm and wall
thicknesses from 0,5 mm up to and including 10 mm.
The sampling procedures, the methods of test for verification of conformity to the requirements of this standard, and
the delivery conditions are also specified.
Kupfer und Kupferlegierungen - Nahtlose Rohre aus Kupfer für die Anwendung in der Elektrotechnik
Diese Europäische Norm legt die Zusammensetzung, die Anforderungen an die Eigenschaften einschließlich
elektrische Eigenschaften, Grenzabmaße und Formtoleranzen für nahtlose Kupferrohre für die Elektrotechnik,
geliefert in geraden Längen, fest, mit den Querschnitten und Größenbereichen wie folgt:
für Rundrohre mit Außendurchmessern von 5 mm bis 150 mm und Wanddicken von 0,5 mm bis 20 mm;
für quadratische und rechteckige Rohre mit den größten Außenmaßen von 5 mm bis 150 mm und Wanddicken
von 0,5 mm bis 10 mm.
Der Ablauf der Probenentnahme, die Prüfverfahren zur Feststellung der Übereinstimmung mit den Anforderungen
der Norm und die Lieferbedingungen sind ebenfalls festgelegt.
Cuivre et alliages de cuivre - Tubes sans soudure en cuivre pour usages électriques
La présente norme européenne spécifie la composition, les caractéristiques, y compris les caractéristiques électriques et les tolérances de dimensions et de formes des tubes étirés sans soudure en cuivre pour usages électriques fournis en longueurs droites de coupes transversales et de dimensions suivantes :
- pour les tubes ronds de diametres extérieurs compris entre 5 mm et 150 mm inclus et d'épaisseurs de paroi comprises entre 0,5 mm et 20 mm inclus ;
- pour les tubes carrés et rectangulaires de dimensions extérieures principales comprises entre 5 mm et 150 mm inclus et d'épaisseurs de paroi comprises entre 0,5 mm et 10 mm inclus.
Les procédures d'échantillonnage, les méthodes d'essai pour la vérification de la conformité aux exigences de la présente norme et les conditions de livraison sont également spécifiées.
Baker in bakrove zlitine – Nevarjene bakrene cevi za uporabo v elektrotehniki
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Baker in bakrove zlitine – Nevarjene bakrene cevi za uporabo v elektrotehnikiKupfer und Kupferlegierungen - Nahtlose Rohre aus Kupfer für die Anwendung in der ElektrotechnikCuivre et alliages de cuivre - Tubes sans soudure en cuivre pour usages électriquesCopper and copper alloys - Seamless copper tubes for electrical purposes77.150.30Bakreni izdelkiCopper productsICS:Ta slovenski standard je istoveten z:EN 13600:2002SIST EN 13600:2004en01-januar-2004SIST EN 13600:2004SLOVENSKI
STANDARD
SIST EN 13600:2004
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13600March 2002ICS 77.150.30English versionCopper and copper alloys - Seamless copper tubes for electricalpurposesCuivre et alliages de cuivre - Tubes sans soudure en cuivrepour usages électriquesKupfer und Kupferlegierungen - Nahtlose Rohre aus Kupferfür die Anwendung in der ElektrotechnikThis European Standard was approved by CEN on 22 February 2002.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2002 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13600:2002 ESIST EN 13600:2004
EN 13600:2002 (E)ContentspageForeword .3
1Scope .4
2Normative references .4
3Terms and definitions .4
4Designations .5
4.1Material .5
4.2Material condition .5
4.3Product .5
5Ordering information .7
6Requirements .8
6.1Composition .8
6.2Mechanical properties
..............8
6.3Electrical properties .8
6.4Freedom from hydrogen embrittlement .8
6.5Dimensions and tolerances .8
6.6Mass tolerances .10
6.7Surface condition .10
7Sampling .10
7.1General .10
7.2Analysis .10
7.3Mechanical and electrical tests .10
8Test methods .11
8.1Analysis .11
8.2Tensile test .11
8.3Hardness test .11
8.4Electrical resistivity test .11
8.5Hydrogen embrittlement test .11
8.6Retests .11
8.7Rounding of results .12
9Declaration of conformity and inspectiondocumentation .12
9.1Declaration of conformity .12
9.2Inspection documentation .12page10Marking, packaging, labelling .12Annex A
(informative)
Characteristics of coppers for electrical purposes .21Bibliography .23TablesTable 1 — Composition of copper .13Table 2 — Mechanical properties .14Table 3 — Electrical properties (at 20 °C) .15Table 4 — Tolerance on outside diameter ofround tubes .16Table 5 — Tolerance on across-flats dimensions of square and rectangular tubes .17Table 6 — Corner radii of square andrectangular tubes .17Table 7 — Tolerances on wall thickness .18Table 8 — Tolerances on manufacturedlengths .18Table 9 — Tolerances on fixed lengths .18Table 10 — Twist of square and rectangulartubes .18Table 11 — Straightness .18Table 12 — Mass tolerances .18Table 13 — Sampling rate .20Table A.1 – Particular characteristics ofcoppers for electrical purposes .222SIST EN 13600:2004
EN 13600:2002 (E)ForewordThis document EN 13600:2002 has been prepared by Technical Committee CEN/TC 133 "Copper and copperalloys", the secretariat of which is held by DIN.This European Standard shall be given the status of a national standard, either by publication of an identical text orby endorsement, at the latest by September 2002, and conflicting national standards shall be withdrawn at the latestby September 2002.Within its programme of work, Technical Committee CEN/TC 133 requested CEN/TC 133/WG 5 "Copper forelectrical purposes" to prepare the following standard:EN 13600,
Copper and copper alloys — Seamless copper tubes for electrical purposes.The products specified in this European Standard are those which are especially suitable for electrical purposes, i.e.with specified electrical properties. Copper tubes for general purposes are specified in EN 12449.Annex A (informative) gives guidance on the characteristics of coppers for electrical purposes.This is one of a series of European Standards for copper products for electrical purposes. Other copper productsare specified as follows:EN 13599,
Copper and copper alloys — Copper plate, sheet and strip for electrical purposes.EN 13601,
Copper and copper alloys — Copper rod, bar and wire for general electrical purposes.EN 13602,
Copper and copper alloys — Drawn, round copper wire for the manufacture of electrical conductors.EN 13604,
Copper and copper alloys — Products of high conductivity copper for electronic tubes, semiconductordevices and vacuum applications.EN 13605,
Copper and copper alloys — Copper profiles and profiled wire for electrical purposes.According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countriesare bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France,Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden,Switzerland and United Kingdom.3SIST EN 13600:2004
EN 13600:2002 (E)1
ScopeThis European Standard specifies the composition, property requirements including electrical properties, andtolerances on dimensions and form for seamless drawn copper tubes for electrical purposes, delivered in straightlengths with the cross-sections and size ranges below:–for round tubes with outside diameters from 5 mm up to and including 150 mm and wall thicknesses from0,5 mm up to and including 20 mm;–for square and rectangular tubes with major outside dimension from 5 mm up to and including 150 mm and wallthicknesses from 0,5 mm up to and including 10 mm.The sampling procedures, the methods of test for verification of conformity to the requirements of this standard, andthe delivery conditions are also specified.2
Normative referencesThis European Standard incorporates, by dated or undated reference, provisions from other publications. Thesenormative references are cited at the appropriate places in the text, and the publications are listed hereafter. Fordated references, subsequent amendments to or revisions of any of these publications apply to this EuropeanStandard only when incorporated in it by amendment or revision. For undated references, the latest edition of thepublication referred to applies (including amendments).EN 1655,
Copper and copper alloys — Declarations of conformity.EN 1976,
Copper and copper alloys — Cast unwrought copper products.EN 10002-1,
Metallic materials — Tensile testing — Part 1: Method of test (at ambient temperature).EN 10204,
Metallic products — Types of inspection documents.EN ISO 2626,
Copper — Hydrogen embrittlement test (ISO 2626:1973).EN ISO 6506-1,
Metallic materials — Brinell hardness test — Part 1: Test method (ISO 6506-1:1999).EN ISO 6507-1,
Metallic materials — Vickers hardness test — Part 1: Test method (ISO 6507-1:1997).EN ISO 7438,
Metallic materials — Bend test (ISO 7438:1985).ISO 1811-2,
Copper and copper alloys — Selection and preparation of samples for chemical analysis — Part 2:Sampling of wrought products and castings.ISO 8491,
Metallic materials — Tube (in full section) — Bend test.NOTE
Informative references to documents used in the preparation of this standard, and cited at the appropriate places in thetext, are listed in the Bibliography.3
Terms and definitionsFor the purposes of this European Standard, the following terms and definitions apply.3.1 seamless tubehollow semi-finished product, circular, square or rectangular in cross-section, having a uniform wall thickness, whichat all stages of production has a continuous periphery. Tubes with a square or rectangular cross-section may havecorners rounded along their whole length4SIST EN 13600:2004
EN 13600:2002 (E)3.2mean diameterarithmetical mean of any two diameters normal to each other at the same cross-section of the tube3.3deviation from circular formdifference between the maximum and minimum outside diameters measured at any one cross-section of the tube4
Designations4.1
Material4.1.1
GeneralThe material is designated either by symbol or number (see Table 1).4.1.2
SymbolThe material symbol designation is based on the designation system given in ISO 1190-1.NOTE
Although material symbol designations used in this standard might be the same as those in other standards using thedesignation system in ISO 1190-1, the detailed composition requirements are not necessarily the same.4.1.3
NumberThe material number designation is in accordance with the system given in EN 1412.4.2
Material conditionFor the purposes of this standard, the following designations, which are in accordance with the system given inEN 1173, apply for the material condition:DMaterial condition for the product as cold worked without specified mechanical properties;H. Material condition designated by the minimum value of hardness requirement for the product with mandatory hardness requirements;R. Material condition designated by the minimum value of tensile strength requirement for the product withmandatory tensile strength, 0,2% proof strength and elongation requirements.NOTE
Products in the H. condition may be specified to Vickers or Brinell hardness. The material condition designation H. isthe same for both hardness test methods.Exact conversion between the material conditions designated H. and R. is not possible.Material condition is designated by only one of the above designations.4.3
ProductThe product designation provides a standardized pattern of designation from which a rapid and unequivocaldescription of a product is conveyed in communication. It provides mutual comprehension at the international levelwith regard to products which meet the requirements of the relevant European Standard.The product designation is no substitute for the full content of the standard.5SIST EN 13600:2004
EN 13600:2002 (E)The product designation for products to this standard shall consist of:–denomination (Tube);–number of this European Standard (EN 13600);–material designation, either symbol or number (see Table 1);–material condition designation (see Table 2);–cross-sectional shape (the following designations shall be used, as appropriate: RND for round, SQR for square,RCT for rectangular);–nominal dimensions;–round tube: outside diameter × wall thickness × length [either "as manufactured" (M) or "fixed" (F) length (see6.5.4)];–square or rectangular tube: across-flats dimension(s) × wall thickness × length [either "as manufactured" (M)or "fixed" (F) length (see 6.5.4)].The derivation of a product designation is shown in example 1 and other typical product designations are shown inexamples 2 and 3.EXAMPLE 1
Tube for electrical purposes conforming to this standard, in material designated either Cu-ETP or CW004A, inmaterial condition R250, round, nominal outside diameter 100 mm, nominal wall thickness 5 mm, as manufactured length3 000 mm, shall be designated as follows:EXAMPLE 2
Tube for electrical purposes conforming to this standard, in material designated either Cu-0F or CW008A, inmaterial condition H065, square, nominal width across-flats 120 mm, nominal wall thickness 10 mm, fixed length 4 500 mm, shallbe designated as follows:Tube EN 13600 — Cu-OF— H065 — SQR120 × 10 × 4 500ForTube EN 13600 — CW008A — H065 — SQR120 × 10 × 4 500F6SIST EN 13600:2004
EN 13600:2002 (E)EXAMPLE 3
Tube for electrical purposes conforming to this standard, in material designated either CuAg0,10 or CW013A, inmaterial condtion R290, rectangular, nominal widths across-flats 140 mm and 80 mm, nominal wall thickness 5 mm, fixed length3 500 mm, shall be designated as follows:Tube EN 13600 — CuAg0,10 — R290 — RCT140 × 80 × 5 × 3 500ForTube EN 13600 — CW013A— R290 — RCT140 × 80 × 5 × 3 500F5
Ordering informationIn order to facilitate the enquiry, order and confirmation of order procedures between the purchaser and the supplier,the purchaser shall state on his enquiry and order the following information:a)quantity of product required (mass, number of tubes);b)denomination (Tube);c)number of this European Standard (EN 13600);d)material designation (see Table 1);e)material condition designation (see 4.2 and Table 2);f)nominal dimensions:–round tubes: outside diameter × wall thickness × length [either "as manufactured" (M) or "fixed" (F) length(see 6.5.4)];–square or rectangular tubes: across-flats dimension(s) × wall thickness × length [either "as manufactured" (M)or "fixed" (F) length (see 6.5.4)].NOTE
It is recommended that the product designation, as described in 4.3, is used for items b) to f).In addition, the purchaser shall also state on the enquiry and order any of the following, if required:g)test method to be used for the measurement of hardness, i.e. Vickers or Brinell (see 8.3);h)whether special tolerances on dimensions and form are required;i)whether special surface conditions are required (see 6.7);j)whether deburring is required (see 6.5.4.1);k)whether a declaration of conformity is required (see 9.1);l)whether an inspection document is required, and if so, which type (see 9.2);m)whether there are any special requirements for marking, packaging or labelling (see clause 10).EXAMPLE
Ordering details for 1 000 pieces tube for electrical purposes conforming to EN 13600, in material designated eitherCu-ETP or CW004A, in material condition R250, round, nominal outside diameter 100 mm, nominal wall thickness 5 mm, asmanufactured length 3 000 mm:1 000 pieces Tube EN 13600 — Cu-ETP— R250 — RND100 × 5 × 3 000Mor1 000 pieces Tube EN 13600 — CW004A — R250 — RND100 × 5 × 3 000M7SIST EN 13600:2004
EN 13600:2002 (E)6
Requirements6.1
CompositionThe composition shall conform to the requirements for the appropriate material given in Table 1.NOTE
For characteristics of coppers for electrical purposes, see annex A.6.2
Mechanical propertiesThe mechanical properties shall conform to the appropriate requirements given in Table 2. The tests shall be carriedout in accordance with either 8.2 (tensile test) or 8.3 (hardness test).6.3
Electrical propertiesThe electrical properties shall conform to the appropriate requirements given in Table 3. The test shall be carried outin accordance with 8.4.6.4
Freedom from hydrogen embrittlementTubes in copper grades Cu-OF (CW008A), CuAg0,10P (CW016A), CuAg0,10(OF) (CW019A), Cu-PHC (CW020A)and Cu-HCP (CW021A) shall show no evidence of cracking, when tested and visually examined in accordance with8.5.6.5
Dimensions and tolerances6.5.1
Outside dimensionsThe dimensional tolerances are applied on the outside dimensions and wall thickness, if not otherwise agreedbetween the purchaser and the supplier.For round tubes the diameter shall conform to the tolerances given in Table 4.For square and rectangular tubes the outside dimensions shall conform to the tolerances given in Table 5.6.5.2
Corner radiiThe corner radii of square and rectangular tubes shall conform to the requirements given in Table 6.6.5.3
Wall thicknessThe wall thickness of round, square and rectangular tubes, measured at any one point, shall conform to thetolerances given in Table 7.6.5.4
Length 6.5.4.1 GeneralTubes shall be supplied either in "as manufactured" or "fixed" lengths, with ends either sawn or sheared.If deburring of the cut ends of the tubes is required it shall be agreed between the purchaser and the supplier see 5 j) .8SIST EN 13600:2004
EN 13600:2002 (E)6.5.4.2 As manufactured lengthsAs manufactured lengths (M) shall be supplied in the nominal lengths and with the tolerances given in Table 8.It is permissible for 10 % of the number of tubes in a consignment to be shorter, but not less than 50 % of thenominal length.6.5.4.3 Fixed lengthsTubes supplied as fixed lengths (F) shall conform to the tolerances given in Table 9.The deviation from squareness of the cut shall be a maximum of 2 % of the diameter or major across-flatsdimension of the tube and is included in the fixed length tolerance.6.5.5 Form tolerances6.5.5.1 GeneralThe form tolerances given in 6.5.5.2 and 6.5.5.3 apply to:a)outside dimensions equal to or greater than 10 mm;b)all material conditions except D, H040 and R200. The deviation shall be measured with the tube supported on a horizontal base plate such that the deviation isminimized by the mass of the tube.6.5.5.2 TwistSquare and rectangular tubes shall conform to the tolerances given in Table 10. The twist v
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.