23.040.15 - Non-ferrous metal pipes
ICS 23.040.15 Details
Non-ferrous metal pipes
Rohre aus NE-Metallen
Canalisations en métaux non ferreux
Cevi iz neželeznih kovin
General Information
e-Library Subscription
Create subscription and get permanent access to documents within 23.040.15 - Non-ferrous metal pipes
Currently subscription includes documents marked with .We are working on making all documents available within the subscription.
This European Standard specifies the composition, property requirements and tolerances on dimensions and form for seamless round drawn copper and copper alloy tubes for general purposes supplied in the size range from 3 mm up to and including 450 mm outside diameter and from 0,3 mm up to and including 20 mm wall thickness.
The sampling procedures and the methods of test for verification of conformity to the requirements of this European Standard are also specified.
NOTE Tubes having an outside diameter less than 80 mm and/or a wall thickness greater than 2 mm in certain alloys are most frequently used for free machining purposes which are specified in EN 12168.
- Standard51 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the composition, property requirements and tolerances on dimensions and form for seamless round drawn copper and copper alloy tubes for general purposes supplied in the size range from 3 mm up to and including 450 mm outside diameter and from 0,3 mm up to and including 20 mm wall thickness.
The sampling procedures and the methods of test for verification of conformity to the requirements of this document are also specified.
NOTE Tubes having an outside diameter less than 80 mm and/or a wall thickness greater than 2 mm in certain alloys are most frequently used for free machining purposes which are specified in EN 12168.
- Standard51 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the technical conditions for the inspection and delivery of wrought aluminium and aluminium alloys rods/bars, tubes and wires for general engineering applications. It is applicable to products which are extruded and then cold drawn. It does not apply to: — products which are rolled and then cold drawn, including seam-welded tubes; — forging stock, wire for drawing stock; — drawn wires for aeronautical application, electrical or welding purposes.
- Standard14 pagesEnglish languagesale 15% off
This document specifies the technical conditions for inspection and delivery of wrought aluminium and aluminium alloy rods/bars, tubes and profiles for general engineering applications. It is applicable to extruded products, but does not apply to the following: — forging stock; — extruded precision profiles in alloys A6060 and A6063; — products delivered in coils; — coiled tubes cut to lengths.
- Standard14 pagesEnglish languagesale 15% off
This document specifies the tolerances on form and dimensions of wrought aluminium and aluminium alloy drawn round tubes (seamless and porthole). This document is applicable to cold-drawn round tubes.
- Standard6 pagesEnglish languagesale 15% off
This document specifies the mechanical properties of wrought aluminium and aluminium alloy extruded rods/bars, tubes, and profiles for general engineering applications. It is applicable to extruded products.
- Standard25 pagesEnglish languagesale 15% off
This document specifies the mechanical properties of wrought aluminium and aluminium alloy rods/bars, tubes and wires for general engineering applications (except aeronautical rivets). It is applicable to products which are extruded and then cold drawn. It does not apply to: — products which are rolled and then cold drawn, including seam-welded tubes; — forging stock, wire for drawing stock; — drawn wires for aeronautical application, electrical or welding purposes.
- Standard18 pagesEnglish languagesale 15% off
This document specifies the requirements, sampling, test methods and conditions of delivery for seamless round copper and copper alloy tubes used for refrigeration and air-conditioning piping systems (i.e. piping, connections and repairs).
It is applicable to tubes with an outside diameter from 3 mm up to and including 219 mm.
Tubes made of the copper-grade Cu-DHP are supplied in straight lengths in the material conditions hard or half-hard, or in coils in the annealed material condition.
Tubes made of the alloy CuFe2P are supplied in straight length in the material conditions hard or annealed.
- Standard24 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a procedure for the eddy current test with an encircling test coil for measuring defects on the outer surface of seamless round copper and copper alloy tubes.
NOTE The eddy current test method(s) required, together with the size range and acceptance level, are defined in the relevant product standard.
The choice of the method for eddy current test:
- with an encircling test coil on the outer surface according to prEN 1971-1;
or
- with an internal probe on the inner surface according to prEN 1971-2;
is at the discretion of the manufacturer if there are no other agreements between the purchaser and the supplier.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a procedure for the eddy current test with an internal probe for measuring defects on the inner surface of seamless round copper and copper alloy tubes.
This document applies particularly for finned tubes with high fins according to EN 12452.
NOTE The eddy current test method(s) required, together with the size range and acceptance level, are defined in the relevant product standard.
The choice of the method for eddy current test:
- with an encircling test coil on the outer surface according to prEN 1971-1
or
- with an internal probe on the inner surface according to prEN 1971-2
is at the discretion of the manufacturer if there are no other agreements between the purchaser and the supplier.
Especially for finned tubes according to EN 12452 with high fins, it is suggested to use eddy current test with internal probe as described in this document.
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements, sampling, test methods and conditions of delivery for seamless round copper and copper alloy tubes used for refrigeration and air-conditioning piping systems (i.e. piping, connections and repairs).
It is applicable to tubes with an outside diameter from 3 mm up to and including 219 mm.
Tubes made of the copper-grade Cu-DHP are supplied in straight lengths in the material conditions hard or half-hard, or in coils in the annealed material condition.
Tubes made of the alloy CuFe2P are supplied in straight length in the material conditions hard or annealed.
- Standard24 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a procedure for the eddy current test with an encircling test coil for measuring defects on the outer surface of seamless round copper and copper alloy tubes.
NOTE The eddy current test method(s) required, together with the size range and acceptance level, are defined in the relevant product standard.
The choice of the method for eddy current test:
- with an encircling test coil on the outer surface according to prEN 1971-1;
or
- with an internal probe on the inner surface according to prEN 1971-2;
is at the discretion of the manufacturer if there are no other agreements between the purchaser and the supplier.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a procedure for the eddy current test with an internal probe for measuring defects on the inner surface of seamless round copper and copper alloy tubes.
This document applies particularly for finned tubes with high fins according to EN 12452.
NOTE The eddy current test method(s) required, together with the size range and acceptance level, are defined in the relevant product standard.
The choice of the method for eddy current test:
- with an encircling test coil on the outer surface according to prEN 1971-1
or
- with an internal probe on the inner surface according to prEN 1971-2
is at the discretion of the manufacturer if there are no other agreements between the purchaser and the supplier.
Especially for finned tubes according to EN 12452 with high fins, it is suggested to use eddy current test with internal probe as described in this document.
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, sampling, test methods and conditions of delivery for seamless round copper tubes, smooth or inner finned, used for heat exchangers and their internal connecting pipes in the manufacturing of refrigeration and air conditioning equipment.
It is applicable to tubes with an outside diameter from 3,97 mm up to and including 219 mm.
NOTE The tubes are supplied in straight length in the material conditions hard, half-hard or skin hard or as coils in the material conditions light annealed or soft annealed.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, sampling, test methods and conditions of delivery for copper tubes.
It is applicable to seamless round copper tubes having an outside diameter from 6 mm up to and including 219 mm for pipeline systems under vacuum or for distributing the following medical gases intended to be used at operating pressures up to 2 000 kPa:
- oxygen, nitrous oxide, nitrogen, helium, carbon dioxide, xenon;
- medical air;
- specific mixtures of these above mentioned gases;
- air for driving surgical tools;
- anaesthetic gases and vapours.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, sampling, test methods and conditions of delivery for copper tubes.
It is applicable to seamless round copper tubes having an outside diameter from 6 mm up to and including 219 mm for pipeline systems under vacuum or for distributing the following medical gases intended to be used at operating pressures up to 2 000 kPa:
- oxygen, nitrous oxide, nitrogen, helium, carbon dioxide, xenon;
- medical air;
- specific mixtures of these above mentioned gases;
- air for driving surgical tools;
- anaesthetic gases and vapours.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, sampling, test methods and conditions of delivery for seamless round copper tubes, smooth or inner finned, used for heat exchangers and their internal connecting pipes in the manufacturing of refrigeration and air conditioning equipment.
It is applicable to tubes with an outside diameter from 3,97 mm up to and including 219 mm.
The tubes are supplied in straight length in the material conditions hard, half-hard or skin hard or as coils in the material conditions light annealed or soft annealed.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 13085:2014 specifies the technical delivery condition, manufacturing process, material requirements, configuration and dimensions, and verification and inspection procedures for aluminium alloy pipes for use as tubing for wells in petroleum and natural gas industries.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the composition, property requirements and tolerances on dimensions and on form for seamless round copper capillary tubes for use as metering lines for liquids or gases where close controls over the smooth¬ness and dimensions of the bore are required to ensure uniform flow characteristics.
This European Standard applies to capillary tubes in straight lengths, or in coils, in the size range up to and including 6,10 mm outside diameter and from 0,30 mm up to and including 4,45 mm inside diameter which are intended for restrictor applications.
The sampling procedures and the methods of test for verification of conformity to the requirements of this European Standard are also specified.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the composition, property requirements and tolerances on dimensions and on form for seamless round copper capillary tubes for use as metering lines for liquids or gases where close controls over the smooth¬ness and dimensions of the bore are required to ensure uniform flow characteristics.
This European Standard applies to capillary tubes in straight lengths, or in coils, in the size range up to and including 6,10 mm outside diameter and from 0,30 mm up to and including 4,45 mm inside diameter which are intended for restrictor applications. The sampling procedures and the methods of test for verification of conformity to the requirements of this European Standard are also specified.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the composition, property requirements and tolerances on dimensions and form for seamless round drawn copper and copper alloy tubes for heat exchangers, condensers, evaporators and desalination equipment. It gives guidelines for copper and copper alloy tubes supplied in the size range from 6 mm up to and including 76 mm outside diameter and from 0,5 mm up to and including 3 mm wall thickness.
The sampling procedures and the methods of test for verification of conformity to the requirements of this European Standard are also specified.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the composition, property requirements and tolerances on dimensions and form for rolled, finned, seamless copper and copper alloy tubes for heat exchangers. It gives guidelines for copper and copper alloy tubes supplied in the size range from 6 mm up to and including 35 mm outside diameter; from 1 mm up to and including 3 mm wall thickness of the unfinned section; and with fin height up to and including 1,5 mm.
The sampling procedures and the methods of testing for verification of conformity to the requirements of this European Standard are also specified.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the composition, property requirements and tolerances on dimensions and form for rolled, finned, seamless copper and copper alloy tubes for heat exchangers supplied in the size range from 6 mm up to and including 35 mm outside diameter and from 1 mm up to and including 3 mm wall thickness of the unfinned section with fin height up to and including 1,5 mm. The sampling procedures and the methods of test for verification of conformity to the requirements of this standard are also specified.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the composition, property requirements and tolerances on dimensions and form for seamless round drawn copper and copper alloy tubes for heat exchangers, condensers, evaporators and desalina¬tion equipment, supplied in the size range from 6 mm up to and including 76 mm outside diameter and from 0,5 mm up to and including 3 mm wall thickness.The sampling procedures and the methods of test for verification of conformity to the requirements of this standard are also specified.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, sampling, test methods and conditions of delivery for seamless round copper tubes.
It is applicable to tubes having an outside diameter from 6 mm up to and including 267 mm for:
- distributing networks for hot water and cold water;
- hot water heating systems, including panel heating systems (under-floor, wall, overhead);
- domestic gas and liquid fuel distribution;
- waste water sanitation.
It is also applicable to seamless round copper tubes intended to be pre insulated before use for any of the above purposes.
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard35 pagesGerman languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, sampling, test methods and conditions of delivery for seamless round copper tubes. It is applicable to tubes having an outside diameter from 6 mm up to and including 267 mm for: - distributing networks for hot water and cold water; - hot water heating systems, including panel heating systems (under-floor, wall, overhead); - domestic gas and liquid fuel distribution; - waste water sanitation. It is also applicable to seamless round copper tubes intended to be pre-insulated before use for any of the above purposes.
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard35 pagesGerman languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, sampling, test methods and conditions of delivery for seamless
round copper tubes covered with solid plastics material.
It is applicable to tubes intended for:
- distributing networks for hot water and cold water;
- hot water heating systems (temperature not exceeding 95 °C) including underfloor heating systems;
- domestic gas and liquid fuel distribution.
NOTE The primary purpose of the covering is to protect the copper tube against external corrosion in service. In addition, the
covering can give some protection against impact and mechanical loading during transportation, installation and operation.
Coverings whose primary objective is thermal insulation are not included in this standard.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, sampling, test methods and conditions of delivery for seamless
round copper tubes covered with solid plastics material.
It is applicable to tubes intended for:
- distributing networks for hot water and cold water;
- hot water heating systems (temperature not exceeding 95 °C) including underfloor heating systems;
- domestic gas and liquid fuel distribution.
NOTE The primary purpose of the covering is to protect the copper tube against external corrosion in service. In addition, the
covering can give some protection against impact and mechanical loading during transportation, installation and operation.
Coverings whose primary objective is thermal insulation are not included in this standard.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements, sampling, test methods and conditions of delivery for seamless round copper tubes, smooth or inner finned, used for heat exchangers and their internal connecting pipes in the manufacturing of refrigeration and air conditioning equipment.
It is applicable to tubes with an outside diameter from 3,97 mm up to and including 219 mm.
NOTE The tubes are supplied in straight length or as coils.
- Draft27 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements, sampling, test methods and conditions of delivery for seamless round copper tubes, smooth or inner finned, used for heat exchangers and their internal connecting pipes in the manufacturing of refrigeration and air conditioning equipment.
It is applicable to tubes with an outside diameter from 3,97 mm up to and including 219 mm.
NOTE The tubes are supplied in straight length or as coils.
- Draft27 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies requirements for metallic industrial piping and their parts made of nickel and nickel alloys (see 3.1) in addition to the general requirements for metallic industrial piping under EN 13480 1:2017, EN 13480 2:2017, EN 13480 3:2017, EN 13480 4:2017 and EN 13480 5:2017.
NOTE Cast materials are not included in this version. Details regarding cast materials will be subject to an amendment to or a revision of this document.
- Draft22 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the composition, property requirements and tolerances on dimensions and form for seamless round drawn copper and copper alloy tubes for general purposes supplied in the size range from 3 mm up to and including 450 mm outside diameter and from 0,3 mm up to and including 20 mm wall thickness.
The sampling procedures and the methods of test for verification of conformity to the requirements of this European Standard are also specified.
NOTE Tubes having an outside diameter less than 80 mm and/or a wall thickness greater than 2 mm in certain alloys are most frequently used for free machining purposes which are specified in EN 12168.
- Draft5 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies requirements for metallic industrial piping and their parts made of nickel and nickel alloys (see 3.1) in addition to the general requirements for metallic industrial piping under EN 13480-1:2017, EN 13480-2:2017, EN 13480-3:2017, EN 13480-4:2017 and EN 13480-5:2017.
NOTE Cast materials are not included in this version. Details regarding cast materials will be subject to an amendment to or a revision of this document.
- Draft22 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the composition, property requirements and tolerances on dimensions and form for seamless round drawn copper and copper alloy tubes for general purposes supplied in the size range from 3 mm up to and including 450 mm outside diameter and from 0,3 mm up to and including 20 mm wall thickness.
The sampling procedures and the methods of test for verification of conformity to the requirements of this European Standard are also specified.
NOTE Tubes having an outside diameter less than 80 mm and/or a wall thickness greater than 2 mm in certain alloys are most frequently used for free machining purposes which are specified in EN 12168.
- Draft5 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the composition, property requirements and tolerances on dimensions and form for seamless round drawn copper and copper alloy tubes for general purposes supplied in the size range from 3 mm up to and including 450 mm outside diameter and from 0,3 mm up to and including 20 mm wall thickness.
The sampling procedures and the methods of test for verification of conformity to the requirements of this European Standard are also specified.
NOTE Tubes having an outside diameter less than 80 mm and/or a wall thickness greater than 2 mm in certain alloys are most frequently used for free machining purposes which are specified in EN 12168.
- Standard49 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the composition, property requirements and tolerances on dimensions and form for seamless round drawn copper and copper alloy tubes for general purposes supplied in the size range from 3 mm up to and including 450 mm outside diameter and from 0,3 mm up to and including 20 mm wall thickness.
The sampling procedures and the methods of test for verification of conformity to the requirements of this European Standard are also specified.
NOTE Tubes having an outside diameter less than 80 mm and/or a wall thickness greater than 2 mm in certain alloys are most frequently used for free machining purposes which are specified in EN 12168.
- Standard49 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies requirements (composition, mechanical properties, dimensional tolerances, limiting bend radii) and test procedures for the following materials in the following size ranges: tube for general purpose: cold worked - outside diameter 4 mm to 240 mm, hot worked - outside diameter 38 mm to 240 mm; tube for condenser and heat-exchanger applications: cold worked - maximum outside diameter 80 mm with wall thickness up to and including 5 mm. Annex A lists ISO methods of analysis.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard14 pagesEnglish languagesale 15% off
- Standard15 pagesFrench languagesale 15% off
- Standard15 pagesFrench languagesale 15% off
This European Standard specifies the requirements, sampling, test methods and conditions of delivery for seamless round copper and copper alloy tubes used for refrigeration and air-conditioning piping systems (i.e. piping, connections and repairs).
It is applicable to tubes with an outside diameter from 3 mm up to and including 219 mm.
Tubes made of the copper-grade Cu-DHP are supplied in straight lengths in the material conditions hard or half-hard, or in coils in the annealed material condition.
Tubes made of the alloy CuFe2P are supplied in straight length in the material conditions hard or annealed.
- Standard23 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, sampling, test methods and conditions of delivery for seamless round copper and copper alloy tubes used for refrigeration and air-conditioning piping systems (i.e. piping, connections and repairs).
It is applicable to tubes with an outside diameter from 3 mm up to and including 219 mm.
Tubes made of the copper-grade Cu-DHP are supplied in straight lengths in the material conditions hard or half-hard, or in coils in the annealed material condition.
Tubes made of the alloy CuFe2P are supplied in straight length in the material conditions hard or annealed.
- Standard23 pagesEnglish languagesale 10% offe-Library read for1 day
This part of this European Standard specifies a procedure for the eddy current test with an internal test coil for measuring defects on the inner surface of seamless round copper and copper alloy tubes. The eddy current test method(s) required, together with the size range and acceptance level, are defined in the relevant product standard. The choice of the method for eddy current test:
- with an encircling test coil on the outer surface according EN 1971-1; or
- with an internal test coil on the inner surface according EN 1971-2;
is at the discretion of the manufacturer if there are no other agreements between the purchaser and the supplier. Especially for finned tubes according to EN 12452 with high fins it is recommended to use eddy current test with internal sensor as described in this standard.
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a procedure for the eddy current test with an encircling test coil for measuring defects on the outer surface of seamless round copper and copper alloy tubes. The eddy current test method(s) required, together with the size range and acceptance level, are defined in the relevant product standard. The choice of the method for eddy current test:
- with an encircling test coil on the outer surface according EN 1971-1; or
- with an internal test coil on the inner surface according EN 1971-2;
is at the discretion of the manufacturer if there are no other agreements between the purchaser and the supplier.
- Standard8 pagesEnglish languagesale 10% offe-Library read for1 day
This part of this European Standard specifies a procedure for the eddy current test with an encircling test coil for measuring defects on the outer surface of seamless round copper and copper alloy tubes.
NOTE The eddy current test method(s) required, together with the size range and acceptance level, are defined in the relevant product standard.
The choice of the method for eddy current test:
- with an encircling test coil on the outer surface according EN 1971-1;
or
- with an internal probe on the inner surface according EN 1971-2;
is at the discretion of the manufacturer if there are no other agreements between the purchaser and the supplier.
- Standard8 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a procedure for the eddy current test with an internal probe for measuring defects on the inner surface of seamless round copper and copper alloy tubes.
This European Standard applies particularly for finned tubes with high fins according to EN 12452.
NOTE The eddy current test method(s) required, together with the size range and acceptance level, are defined in the relevant product standard.
The choice of the method for eddy current test:
- with an encircling test coil on the outer surface according EN 1971-1
or
- with an internal probe on the inner surface according EN 1971-2
is at the discretion of the manufacturer if there are no other agreements between the purchaser and the supplier.
Especially for finned tubes according to EN 12452 with high fins, it is recommended to use eddy current test with internal probe as described in this standard.
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the composition, property requirements and tolerances on dimensions and form for seamless round drawn copper and copper alloy tubes for general purposes supplied in the size range from 3 mm up to and including 450 mm outside diameter and from 0,3 mm up to and including 20 mm wall thickness.
The sampling procedures and the methods of test for verification of conformity to the requirements of this European Standard are also specified.
NOTE Tubes having an outside diameter less than 80 mm and/or a wall thickness greater than 2 mm in certain alloys are most frequently used for free machining purposes which are specified in EN 12168.
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the composition, property requirements and tolerances on dimensions and form for seamless round drawn copper and copper alloy tubes for general purposes supplied in the size range from 3 mm up to and including 450 mm outside diameter and from 0,3 mm up to and including 20 mm wall thickness.
The sampling procedures and the methods of test for verification of conformity to the requirements of this European Standard are also specified.
NOTE Tubes having an outside diameter less than 80 mm and/or a wall thickness greater than 2 mm in certain alloys are most frequently used for free machining purposes which are specified in EN 12168.
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
This Part of this European Standard specifies requirements for industrial piping systems made of aluminium and aluminium alloys in addition to the general requirements for industrial piping according to the series of standards EN 13480:2012 and CEN/TR 13480-7:2002. Revision of Annex B "Transition joints".
- Amendment10 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment11 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, sampling, test methods and conditions of delivery for seamless round copper tubes used for refrigeration and air-conditioning piping systems (i.e. piping, connections, repairs). It is applicable to tubes with an outside diameter from 3 mm up to and including 133 mm. These tubes are supplied in straight lengths in the material conditions hard or half-hard, or in coils in the annealed material condition.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, sampling, test methods and conditions of delivery for seamless round copper tubes, smooth or inner finned, used for heat exchangers and their internal connecting pipes in the manufacturing of refrigeration and air conditioning equipment. It is applicable to tubes with an outside diameter from 6 mm up to and including 133 mm. The tubes are supplied in straight length in the material conditions hard, half-hard or skin hard or as coils in the material conditions light annealed or soft annealed.
- Standard23 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, sampling, test methods and conditions of delivery for seamless round copper tubes used for refrigeration and air-conditioning piping systems (i.e. piping, connections, repairs).
It is applicable to tubes with an outside diameter from 3 mm up to and including 133 mm.
These tubes are supplied in straight lengths in the material conditions hard or half-hard, or in coils in the annealed material condition.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, sampling, test methods and conditions of delivery for seamless round copper tubes, smooth or inner finned, used for heat exchangers and their internal connecting pipes in the manufacturing of refrigeration and air conditioning equipment.
It is applicable to tubes with an outside diameter from 6 mm up to and including 133 mm.
The tubes are supplied in straight length in the material conditions hard, half-hard or skin hard or as coils in the material conditions light annealed or soft annealed.
- Standard23 pagesEnglish languagesale 10% offe-Library read for1 day