Abstract

ICS proforma for ETS 300 417-2-1.

Status
Published
Publication Date
30-Nov-2003
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Dec-2003
Due Date
01-Dec-2003
Completion Date
01-Dec-2003

Buy Documents

Standard

SIST EN 300 417-2-2 V1.1.4:2003

English language (123 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN 300 417-2-2 V1.1.4:2003 is the Slovenian standard identical to EN 300 417-2-2 Version 1.1.4. It gives the Implementation Conformance Statement (ICS) proforma for the SDH and PDH physical section layer functions defined in EN 300 417-2-1, so a supplier can state which capabilities an implementation supports in a standard format. It is aimed at equipment suppliers, test laboratories and buyers or operators who need a layer-by-layer conformance statement for transmission equipment.

What does SIST EN 300 417-2-2 V1.1.4:2003 specify?

SIST EN 300 417-2-2 V1.1.4:2003 specifies the ICS proforma used to describe conformance to the SDH and PDH physical section layer functions of EN 300 417-2-1. In practice, it tells the supplier what to record, how to mark each item as mandatory, optional or conditional, and how to present the answer so it can be used in conformance testing.

The document is organized as a short main text plus normative annexes. Clause 4 states how a completed ICS must match the proforma structure and ordering. Annex A explains how to complete the forms, and Annexes B-L provide layer-specific proformas.

AnnexWhat it covers
AGuidance for completing the ICS proforma for EN 300 417-2-1
BSTM-1 optical section layer
CSTM-4 optical section layer
DSTM-16 optical section layer
ESTM-1 electrical section layer
FE4 electrical section layer
GE31 electrical section layer
HE22 electrical section layer
JE12 electrical section layer
KT12 electrical section layer
LE0 electrical section layer

What are the key requirements of SIST EN 300 417-2-2 V1.1.4:2003?

How the ICS must be completed

Clause 4 requires a conforming ICS to be technically equivalent to the annex proforma and to preserve the numbering, naming and order of the items. It also says a separate ICS proforma is needed for each layer instance. That matters because conformance is checked per implemented layer, not just for the whole product.

Annex A gives the completion rules. The status column uses the standard ICS meanings - mandatory, optional, not applicable, prohibited, qualified optional and conditional - and the support column is filled by the supplier with yes/no-style answers. For multiple-profile systems, the supplier can use conditional expressions linked to the System Conformance Statement (SCS), so one form can still show which options are supported in each profile.

What the layer annexes ask you to declare

Annexes B-D cover the optical section layers OS1, OS4 and OS16. Each annex asks for identification of the implementation, a global statement of conformance, a layer description, transmission tables, and defect, fault and performance monitoring tables. The layer description requires at least one trail termination function, with adaptation functions linked to the chosen source or sink side.

Each optical annex also classifies the interface by application and source type. The proforma distinguishes intra-office, short-haul and long-haul use cases, then ties them to source wavelength range, spectral width, launched power, extinction ratio, receiver sensitivity, overload and reflectance. In practice, the supplier must declare the exact optical class and interface characteristics, not just say that the port is “optical”.

What the monitoring and fault items cover

The optical annexes include defect handling for Loss Of Signal (dLOS), Loss Of Frame (dLOF), Trail Signal Fail (aTSF), Server Signal Fail (aSSF), Alarm Indication Signal (aAIS), defect correlation and performance monitoring. They also cover port status modes such as NMON, MON and AUTO, plus the reporting of Out Of Frame Second (pOFS) to the Equipment Management Function (EMF). That tells a tester or buyer what alarms and status behaviour the implementation must expose.

The electrical annexes follow the same pattern for ES1, E4, E31, E22, E12, T12 and E0, but their tables focus on data stream, connection function, trail termination and adaptation functions, followed by defect and performance monitoring.

What terms does SIST EN 300 417-2-2 V1.1.4:2003 define?

  • Implementation Conformance Statement (ICS) - a statement from the supplier saying which capabilities an implementation supports for a given specification.
  • ICS proforma - the questionnaire form that is completed to become an ICS.
  • Implementation Under Test (IUT) - the specific implementation instance being assessed.
  • System Under Test (SUT) - the system that contains the IUT.
  • Equipment Management Function (EMF) - the management function that receives reported fault causes and performance information.
  • Alarm Indication Signal (AIS) - a signal inserted when a higher-layer failure needs to be indicated downstream.
  • Loss Of Signal (dLOS) - the defect declared when the received optical signal falls below the operational level and frame alignment would be interrupted.

Who uses SIST EN 300 417-2-2 V1.1.4:2003?

Suppliers of SDH and PDH transport equipment use this standard to complete conformance declarations for optical and electrical section layers. Test laboratories use it to decide which conformance tests apply to a given implementation. Buyers, operators and quality teams use it to compare vendor declarations in a consistent way and to check that the declared layer functions, monitoring behaviour and interface class are the ones they need.

What changed in SIST EN 300 417-2-2 V1.1.4:2003 from the previous edition?

ETSI states that this version was published because the previous two versions had incorrect dates in the transposition table. The foreword also says the EN family was converted from ETS 300 417 without technical changes, while some editorial corrections were made, including fixes in parts 2-1, 2-2 and 3-2.

Which standards are used with SIST EN 300 417-2-2 V1.1.4:2003?

  • EN 300 417-2-1 - supplies the physical section layer functions that this ICS proforma profiles.
  • EN 300 417-1-1 - supplies the generic processes and performance terms used for defect, fault and monitoring behaviour.
  • EN 300 417-6-1 - is part of the same transport-functionality family and is listed as a companion part.
  • ETS 300 406 and ISO/IEC 9646-7 - provide the conformance testing and ICS methodology used to structure the proforma.
  • ISO/IEC 9646-1 - gives the general conformance testing concepts used in the definitions.
  • ETS 300 232 and ITU-T G.957 - provide the optical interface characteristics used in the optical annexes.
  • ITU-T G.652, G.653 and G.654 - define the fibre types referenced by the long-haul optical options.
  • ETS 300 166, ETS 300 167, ETS 300 337, CCITT G.703, G.704, G.706, G.742, G.751, ITU-T G.823, G.825 and G.958 - support the electrical-interface, framing, jitter and transmission behaviour referenced in the proforma.

What does the SIST EN 300 417-2-2 V1.1.4:2003 document contain?

The document contains standardized questionnaire forms for layer conformance, with identification fields for the IUT, SUT, supplier, client and contact person. It also contains tables for optical and electrical layer functions, including source and sink functions, adaptation functions, wavelength and power characteristics, receiver limits, jitter, framing and monitoring behaviour.

Annex A gives the rules for interpreting the item, status and support columns and for using conditional expressions. The annex tables include the kinds of values and test-related declarations that a laboratory needs to select the right checks, but the standard overview does not reproduce the table values, masks or formulas.

Buy Documents

Standard

SIST EN 300 417-2-2 V1.1.4:2003

English language (123 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

SIST EN 300 417-2-2 V1.1.4:2003 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Transmission and Multiplexing (TM); Generic requirements of transport functionality of equipment; Part 2-2: Synchronous Digital Hierarchy (SDH) and Plesiochronous Digital Hierarchy (PDH) physical section layer functions; Implementation Conformance Statement (ICS) proforma specification". This standard covers: ICS proforma for ETS 300 417-2-1.

ICS proforma for ETS 300 417-2-1.

SIST EN 300 417-2-2 V1.1.4:2003 is classified under the following ICS (International Classification for Standards) categories: 33.040.20 - Transmission systems. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 300 417-2-2 V1.1.4:2003 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.XQNFLRQDOQRVWTransmission and Multiplexing (TM); Generic requirements of transport functionality of equipment; Part 2-2: Synchronous Digital Hierarchy (SDH) and Plesiochronous Digital Hierarchy (PDH) physical section layer functions; Implementation Conformance Statement (ICS) proforma specification33.040.20Prenosni sistemTransmission systemsICS:Ta slovenski standard je istoveten z:EN 300 417-2-2 Version 1.1.4SIST EN 300 417-2-2 V1.1.4:2003en01-december-2003SIST EN 300 417-2-2 V1.1.4:2003SLOVENSKI
STANDARD
EN 300 417-2-2 V1.1.4 (1999-05)European Standard (Telecommunications series)Transmission and Multiplexing (TM);Generic requirements of transport functionality of equipment;Part 2-2: Synchronous Digital Hierarchy (SDH) andPlesiochronous Digital Hierarchy (PDH)physical section layer functions;Implementation Conformance Statement (ICS)proforma specificationSIST EN 300 417-2-2 V1.1.4:2003

ETSIEN 300 417-2-2 V1.1.4 (1999-05)2ReferenceREN/TM-01015-2-2b (3v0iiieo.PDF)KeywordsICS, PDH, SDH, STM, transmission, testingETSIPostal addressF-06921 Sophia Antipolis Cedex - FRANCEOffice address650 Route des Lucioles - Sophia AntipolisValbonne - FRANCETel.: +33 4 92 94 42 00
Fax: +33 4 93 65 47 16Siret N° 348 623 562 00017 - NAF 742 CAssociation à but non lucratif enregistrée à laSous-Préfecture de Grasse (06) N° 7803/88Internetsecretariat@etsi.frIndividual copies of this ETSI deliverablecan be downloaded fromhttp://www.etsi.orgIf you find errors in the present document, send yourcomment to: editor@etsi.frCopyright NotificationNo part may be reproduced except as authorized by written permission.The copyright and the foregoing restriction extend to reproduction in all media.© European Telecommunications Standards Institute 1999.All rights reserved.SIST EN 300 417-2-2 V1.1.4:2003

ETSIEN 300 417-2-2 V1.1.4 (1999-05)3ContentsIntellectual Property Rights.9Foreword.9Introduction.101Scope.112References.113Definitions and abbreviations.123.1Definitions.123.2Abbreviations.124Conformance to this ICS proforma specification.14Annex A (normative):ICS proforma for EN 300 417-2-1.15A.1Guidance for completing the ICS proforma.15A.1.1Purposes and structure.15A.1.2Abbreviations and conventions.15A.1.3Instructions for completing the ICS proforma.17Annex B (normative):ICS proforma for STM-1 optical section layer.18B.1Identification of the implementation.18B.1.1Date of the statement.18B.1.2IUT identification.18B.1.3SUT identification.18B.1.4Product supplier.19B.1.5Client.19B.1.6ICS contact person.20B.2Identification of the EN.20B.3Global statement of conformance of OS1 layer.20B.4OS1 layer description.21B.5OS1 layer transmission tables.22B.5.1OS1 source operating wavelength range, OS1_TT_So.22B.5.2OS1 source spectral characteristics, OS1_TT_So.23B.5.3OS1 source optical characteristics, OS1_TT_So.24B.5.4OS1 receiver characteristics, OS1_TT_Sk.25B.5.5OS1 regeneration characteristics, OS1/RS1_A_So, OS1/RS1_A_Sk.26B.6Defect, fault and performance monitoring.27B.6.1Port status management.27B.6.2Defect detection and clearance criteria.27B.6.3Consequent action activation and clearance criteria.28B.6.4Defect correlation.29B.6.5Performance monitoring.29Annex C (normative):ICS proforma for STM-4 optical section layer.30C.1Identification of the implementation.30C.1.1Date of the statement.30C.1.2IUT identification.30C.1.3SUT identification.30C.1.4Product supplier.31C.1.5Client.31C.1.6ICS contact person.32SIST EN 300 417-2-2 V1.1.4:2003

ETSIEN 300 417-2-2 V1.1.4 (1999-05)4C.2Identification of the EN.32C.3Global statement of conformance of OS4 layer.32C.4OS4 layer description.33C.5OS4 layer transmission tables.34C.5.1OS4 source operating wavelength range, OS4_TT_So.34C.5.2OS4 source spectral characteristics, OS4_TT_So.35C.5.3OS4 source optical characteristics, OS4_TT_So.36C.5.4OS4 receiver characteristics, OS4_TT_Sk.37C.5.5OS4 regeneration characteristics, OS4/RS4_A_So, OS4/RS4_A_Sk.38C.6OS4 layer defect, fault and performance monitoring tables.39C.6.1Port status management.39C.6.2Defect detection and clearance criteria.39C.6.3Consequent action activation and clearance criteria.40C.6.4Defect correlation.41C.6.5Performance monitoring.41Annex D (normative):ICS proforma for STM-16 optical section layer.42D.1Identification of the implementation.42D.1.1Date of the statement.42D.1.2IUT identification.42D.1.3SUT identification.42D.1.4Product supplier.43D.1.5Client.43D.1.6ICS contact person.44D.2Identification of the EN.44D.3Global statement of conformance of OS16 layer.44D.4OS16 layer description.45D.5OS16 layer transmission tables.46D.5.1OS16 source operating wavelength range, OS16_TT_So.46D.5.2OS16 source spectral characteristics, OS16_TT_So.46D.5.3OS16 source optical characteristics, OS16_TT_So.47D.5.4OS16 receiver characteristics, OS16_TT_Sk.48D.5.5OS16 regeneration characteristics, OS16/RS16_A_So, OS16/RS16_A_Sk.49D.6OS16 layer defect, fault and performance monitoring tables.50D.6.1Port status management.50D.6.2Defect detection and clearance criteria.50D.6.3Consequent action activation and clearance criteria.51D.6.4Defect correlation.52D.6.5Performance monitoring.52Annex E (normative):ICS proforma for STM-1 electrical section layer.53E.1Identification of the implementation.53E.1.1Date of the statement.53E.1.2IUT identification.53E.1.3SUT identification.53E.1.4Product supplier.54E.1.5Client.54E.1.6ICS contact person.55SIST EN 300 417-2-2 V1.1.4:2003

ETSIEN 300 417-2-2 V1.1.4 (1999-05)5E.2Identification of the EN.55E.3Global statement of conformance of ES1 layer.55E.4ES1 layer description.56E.5ES1 layer transmission tables.56E.5.1ES1 layer data stream.56E.5.2ES1 layer connection function, ES1_C.56E.5.3ES1 layer trail termination functions, ES1_TT_So and ES1_TT_Sk.57E.5.4ES1 to RS1 adaptation functions, ES1/RS1_A_So and ES1/RS1_A_Sk.58E.6ES1 layer defect, fault and performance monitoring tables.59E.6.1Port status management.59E.6.2Defect detection and clearance criteria.60E.6.3Consequent action activation and clearance criteria.60E.6.4Defect correlation.61E.6.5Performance monitoring.61Annex F (normative):ICS proforma for E4 electrical section layer.62F.1Identification of the implementation.62F.1.1Date of the statement.62F.1.2IUT identification.62F.1.3SUT identification.62F.1.4Product supplier.63F.1.5Client.63F.1.6ICS contact person.64F.2Identification of the EN.64F.3Global statement of conformance of E4 layer.64F.4E4 layer description.65F.5E4 layer transmission tables.65F.5.1E4 layer data stream.65F.5.2E4 layer connection function, E4_C.65F.5.3E4 layer trail termination functions, E4_TT_So and E4_TT_Sk.66F.5.4E4 to P4x adaptation functions, E4/P4x_A_So and E4/P4x_A_Sk.67F.5.5E4to P4e adaptation functions, E4/P4e_A_So and E4/P4e_A_Sk.68F.5.6E4 to P4s adaptation functions, E4/P4s_A_So and E4/P4s_A_Sk.69F.6E4 layer defect, fault and performance monitoring tables.70F.6.1Port status management.70F.6.2Defect detection and clearance criteria.71F.6.3Consequent action activation and clearance criteria.71F.6.4Defect correlation.72Annex G (normative):ICS proforma for E31 electrical section layer.73G.1Identification of the implementation.73G.1.1Date of the statement.73G.1.2IUT identification.73G.1.3SUT identification.73G.1.4Product supplier.74G.1.5Client.74G.1.6ICS contact person.75SIST EN 300 417-2-2 V1.1.4:2003

ETSIEN 300 417-2-2 V1.1.4 (1999-05)6G.2Identification of the EN.75G.3Global statement of conformance of E31 layer.75G.4E31 layer description.76G.5E31 layer transmission tables.76G.5.1E31 layer data stream.76G.5.2E31 layer connection function, E31_C.76G.5.3E31 layer trail termination functions, E31_TT_So and E31_TT_Sk.77G.5.4E31 to P31x adaptation functions, E31/P31x_A_So and E31/P31x_A_Sk.78G.5.5E31to P31e adaptation functions, E31/P31e_A_So and E31/P31e_A_Sk.79G.5.6E31 to P31s adaptation functions, E31/P31s_A_So and E31/P31s_A_Sk.80G.6E31 layer defect, fault and performance monitoring tables.81G.6.1Port status management.81G.6.2Defect detection and clearance criteria.82G.6.3Consequent action activation and clearance criteria.82G.6.4Defect correlation.83Annex H (normative):ICS proforma for E22 electrical section layer.84H.1Identification of the implementation.84H.1.1Date of the statement.84H.1.2IUT identification.84H.1.3SUT identification.84H.1.4Product supplier.85H.1.5Client.85H.1.6ICS contact person.86H.2Identification of the EN.86H.3Global statement of conformance of E22 layer.86H.4E22 layer description.87H.5E22 layer transmission tables.87H.5.1E22 layer data stream.87H.5.2E22 layer connection function, E22_C.87H.5.3E22 layer trail termination functions, E22_TT_So and E22_TT_Sk.88H.5.4E22 to P22x adaptation functions, E22/P22x_A_So and E22/P22x_A_Sk.89H.5.5E22to P22e adaptation functions, E22/P22e_A_So and E22/P22e_A_Sk.90H.6E22 layer defect, fault and performance monitoring tables.91H.6.1Port status management.91H.6.2Defect detection and clearance criteria.91H.6.3Consequent action activation and clearance criteria.92H.6.4Defect correlation.93Annex J (normative):ICS proforma for E12 electrical section layer.94J.1Identification of the implementation.94J.1.1Date of the statement.94J.1.2IUT identification.94J.1.3SUT identification.94J.1.4Product supplier.95J.1.5Client.95J.1.6ICS contact person.96SIST EN 300 417-2-2 V1.1.4:2003

ETSIEN 300 417-2-2 V1.1.4 (1999-05)7J.2Identification of the EN.96J.3Global statement of conformance of E12 layer.96J.4E12 layer description.97J.5E12 layer transmission tables.97J.5.1E12 layer data stream.97J.5.2E12 electrical section connection function, E12_C.97J.5.3E12layer trail termination functions, E12_TT_So and E12_TT_Sk.98J.5.4E12 to P12x adaptation functions, E12/P12x_A_So and E12/P12x_A_Sk.100J.5.5E12 to P12s adaptation functions, E12/P12s_A_So and E12/P12s_A_Sk.101J.6E12 layer defect, fault and performance monitoring tables.104J.6.1Port status management.104J.6.2Defect detection and clearance criteria.104J.6.3Consequent action activation and clearance criteria.105J.6.4Defect correlation.106Annex K (normative):ICS proforma for T12 electrical section layer.107K.1Identification of the implementation.107K.1.1Date of the statement.107K.1.2IUT identification.107K.1.3SUT identification.107K.1.4Product supplier.108K.1.5Client.108K.1.6ICS contact person.109K.2Identification of the EN.109K.3Global statement of conformance of T12 layer.109K.4T12 layer description.110K.5T12 layer transmission tables.110K.5.1T12 layer data stream.110K.5.2T12layer connection function, T12_C.110K.5.3T12layer trail termination functions, T12_TT_So and T12_TT_Sk.110K.5.4T12 to SD adaptation functions, T12/SD_A_So and T12/SD_A_Sk.111K.6T12 layer defect, fault and performance monitoring tables.111K.6.1Port status management.112K.6.2Defect detection and clearance criteria.112K.6.3Consequent action activation and clearance criteria.112K.6.4Defect correlation.113Annex L (normative):ICS proforma for E0 electrical section layer.114L.1Identification of the implementation.114L.1.1Date of the statement.114L.1.2IUT identification.114L.1.3SUT identification.114L.1.4Product supplier.115L.1.5Client.115L.1.6ICS contact person.116L.2Identification of the EN.116L.3Global statement of conformance of E0 layer.116L.4E0 layer description.117L.5E0 layer transmission tables.117L.5.1E0 layer data stream.117L.5.2E0 layer connection function, E0_C.117SIST EN 300 417-2-2 V1.1.4:2003

ETSIEN 300 417-2-2 V1.1.4 (1999-05)8L.5.3E0 layer trail termination functions, E0_TT_So and E0_TT_Sk.118L.5.4E0 to P0s adaptation functions, E0/P0s_A_So and E0/P0s_A_Sk.119L.6E0 layer defect, fault and performance monitoring tables.120L.6.1Port status management.120L.6.2Defect detection and clearance criteria.120L.6.3Consequent action activation and clearance criteria.120L.6.4Defect correlation.121Bibliography.122History.123SIST EN 300 417-2-2 V1.1.4:2003

ETSIEN 300 417-2-2 V1.1.4 (1999-05)9Intellectual Property RightsIPRs essential or potentially essential to the present document may have been declared to ETSI. The informationpertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be foundin SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respectof ETSI standards", which is available free of charge from the ETSI Secretariat. Latest updates are available on theETSI Web server (http://www.etsi.org/ipr).Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guaranteecan be given as to the existence of other IPRs not referenced in SR 000 314 (or the updates on the ETSI Web server)which are, or may be, or may become, essential to the present document.ForewordThis European Standard (Telecommunications series) has been produced by ETSI Technical Committee Transmissionand Multiplexing (TM).The present document is one of a family of documents that has been produced in order to provide inter-vendor andinter-operator compatibility of Synchronous Digital Hierarchy (SDH) equipment.The present document is part 2-2 of a multi-part EN covering the generic requirements of transport functionality ofequipment, as identified below:Part 1-1:"Generic processes and performance".Part 1-2:"General information about Implementation Conformance Statement (ICS) proforma".Part 2-1:"Synchronous Digital Hierarchy (SDH) and Plesiochronous Digital Hierarchy (PDH) physical sectionlayer functions".Part 2-2:"Synchronous Digital Hierarchy (SDH) and Plesiochronous Digital Hierarchy (PDH) physicalsection layer functions; Implementation Conformance Statement (ICS) proforma specification".Part 3-1:"Synchronous Transport Module-N (STM-N) regenerator and multiplex section layer functions".Part 3-2:"Synchronous Transport Module-N (STM-N) regenerator and multiplex section layer functions;Implementaion Conformance Statement (ICS) proforma specification".Part 4-1:"Synchronous Digital Hierarchy (SDH) path layer functions".Part 4-2:"Synchronous Digital Hierarchy (SDH) path layer functions; Implementation Conformance Statement(ICS) proforma specification".Part 5-1:"Plesiochronous Digital Hierarchy (PDH) path layer functions".Part 5-2:"Plesiochronous Digital Hierarchy (PDH) path layer functions; Implementation Conformance Statement(ICS) proforma specification".Part 6-1:"Synchronization layer functions".Part 6-2:"Synchronization layer functions; Implementation Conformance Statement (ICS) proforma specification".Part 7-1:"Auxiliary layer functions".Part 7-2:"Auxiliary layer functions; Implementation Conformance Statement (ICS) proforma specification".Parts 2 to 7 specify the layers and their atomic functions.NOTE 1:The present document does not currently address configuration management.NOTE 2:The SDH radio equipment functional blocks are addressed by ETSI WG TM4.Various of the above parts have previously been published as parts of ETS 300 417.SIST EN 300 417-2-2 V1.1.4:2003

ETSIEN 300 417-2-2 V1.1.4 (1999-05)10They have been converted into parts of EN 300 417 without technical changes, but some editorial changes have beennecessary (e.g. references). In particular:-Parts 2-1, 2-2 and 3-2 have been modified to take account of editorial errors present in edition 1.-Part 1-1 has had its title change of to align with other parts published at a later date.Also note that in the meantime parts 8-1 and 8-2 together will all parts x-3 (Abstract Test Suites) have been stopped.This version of the present document has been published because the previous two versions had incorrect dates in thetransposition table.National transposition datesDate of latest announcement of this EN (doa):31 August 1999Date of latest publication of new National Standardor endorsement of this EN (dop/e):29 February 2000Date of withdrawal of any conflicting National Standard (dow):29 February 2000IntroductionTo evaluate conformance of a particular implementation, it is necessary to have a statement of which capabilities andoptions have been implemented for a telecommunication specification. Such a statement is called an ImplementationConformance Statement (ICS).A client of a test laboratory who requests a conformance / approval test shall provide to the test laboratory a completedICS proforma for each layer to be tested and a detailed system description of the implementation.The ICS proforma is not another complete description of the related specification, but rather a compact form of its staticconformance requirements, to be used by the test laboratory to identify which test shall be performed on a givenimplementation. Not every feature of a profile specification is contained in the related ICS proforma. For particularcases requiring specific information the ICS can refer to the appropriate clause of the related specification by means ofreferences, notes and or comments.The ICS proforma captures the implementation flexibility allowed by the related specification and details which optionare left to the implementor, which are conditionally dependent on other option taken by the implementor.SIST EN 300 417-2-2 V1.1.4:2003

ETSIEN 300 417-2-2 V1.1.4 (1999-05)111ScopeThe present document provides the Implementation Conformance Statement (ICS) proforma specification for theSynchronous Digital Hierarchy (SDH) equipment physical section layer functions defined in EN 300 417-2-1 [7] incompliance with the relevant requirements, and in accordance with the relevant guidance given in ISO/IEC 9646-7 [10]and ETS 300 406 [5].2ReferencesThe following documents contain provisions which, through reference in this text, constitute provisions of the presentdocument.· References are either specific (identified by date of publication, edition number, version number, etc.) ornon-specific.· For a specific reference, subsequent revisions do not apply.· For a non-specific reference, the latest version applies.· A non-specific reference to an ETS shall also be taken to refer to later versions published as an EN with the samenumber.[1]ETS 300 166 (1993): "Transmission and Multiplexing (TM); Physical and electrical characteristicsof hierarchical digital interfaces for equipment using the 2 048 kbit/s - based plesiochronous orsynchronous digital hierarchies".[2]ETS 300 167 (1993): "Transmission and Multiplexing (TM); Functional characteristics of2 048 kbit/s interfaces".[3]ETS 300 232: "Transmission and Multiplexing (TM); Optical interfaces for equipments andsystems relating to the Synchronous Digital Hierarchy [ITU-T Recommendation G.957 (1993)modified]".[4]ETS 300 337 (1993): "Transmission and Multiplexing (TM); Generic frame structures for thetransport of various signals (including Asynchronous Transfer Mode (ATM) cells and SynchronousDigital Hierarch
...