erospace series - Cables, optical 125 μm diameter cladding - Part 100: Tight structure 62,5/125 µm core GI fibre 1,8 mm outside diameter - Product standard

This European Standard specifies the general characteristics, conditions for qualification, acceptance
and quality assurance for fibre optic cable: 4641-100.

Luft- und Raumfahrt - Lichtwellenleiterkabel, Manteldurchmesser 125 µm - Teil 100: Festaderaufbau GI 62,5/125 µm Faser Kabeldurchmesser 1,8 mm - Produktnorm

Série aérospatiale - Câble, optique, diamètre extérieur de la gaine optique 125 µm - Partie 100: Câble à structure serrée fibre à gradient d’indice cœur 62,5/125 µm, diamètre extérieur 1,8 mm - Norme de produit

La présente Norme européenne spécifie les caractéristiques générales ainsi que les conditions de qualification, d’acceptation et d’assurance qualité pour le câble à fibre optique : 4641-100.

Aeronavtika - Kabli, optični, zunanji premer obloge 125 µm - 100. del: Kompaktna struktura 62,5/125 µm, zunanji premer vlakna 1,8 mm - Standard za proizvod

Ta evropski standard določa splošne lastnosti, pogoje za odobritev in sprejetje ter zagotavljanje kakovosti za kabel iz optičnih vlaken: 4641-100.

General Information

Status
Published
Public Enquiry End Date
19-May-2014
Publication Date
18-Oct-2015
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
18-Sep-2015
Due Date
23-Nov-2015
Completion Date
19-Oct-2015

Buy Standard

Standard
EN 4641-100:2015
English language
15 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
EN 4641-100:2015
English language
15 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Draft
k FprEN 4641-100:2014
English language
14 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 4641-100:2015
01-november-2015
Aeronavtika - Kabli, optični, zunanji premer obloge 125 µm - 100. del: Kompaktna
struktura 62,5/125 µm, zunanji premer vlakna 1,8 mm - Standard za proizvod
erospace series - Cables, optical 125 μm diameter cladding - Part 100: Tight structure
62,5/125 µm core GI fibre 1,8 mm outside diameter - Product standard
Luft- und Raumfahrt - Lichtwellenleiterkabel, Manteldurchmesser 125 µm - Teil 100:
Festaderaufbau GI 62,5/125 µm Faser Kabeldurchmesser 1,8 mm - Produktnorm
Série aérospatiale - Câble, optique, diamètre extérieur de la gaine optique 125 µm -
Partie 100: Câble à structure serrée fibre à gradient d’indice cœur 62,5/125 µm, diamètre
extérieur 1,8 mm - Norme de produit
Ta slovenski standard je istoveten z: EN 4641-100:2015
ICS:
33.180.10 (Optična) vlakna in kabli Fibres and cables
49.060 Letalska in vesoljska Aerospace electric
električna oprema in sistemi equipment and systems
SIST EN 4641-100:2015 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 4641-100:2015

---------------------- Page: 2 ----------------------
SIST EN 4641-100:2015


EN 4641-100
EUROPEAN STANDARD

NORME EUROPÉENNE

September 2015
EUROPÄISCHE NORM
ICS 49.090
English Version

Aerospace series - Cables, optical 125 µm diameter
cladding - Part 100: Tight structure 62,5/125 µm core GI
fibre 1,8 mm outside diameter - Product standard
Série aérospatiale - Câble, optique, diamètre extérieur Luft- und Raumfahrt - Lichtwellenleiterkabel,
de la gaine optique 125 µm - Partie 100 : Câble à Manteldurchmesser 125 µm - Teil 100: Festaderaufbau
structure serrée fibre à gradient d'indice cœur GI 62,5/125 µm Faser Kabeldurchmesser 1,8 mm -
62,5/125 µm, diamètre extérieur 1,8 mm - Norme de Produktnorm
produit
This European Standard was approved by CEN on 21 June 2014.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 4641-100:2015 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
SIST EN 4641-100:2015
EN 4641-100:2015 (E)
Contents Page
European foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 5
4 Required characteristics . 5
5 Cable construction . 5
6 Materials . 5
7 Test methods and performances in accordance with EN 3745-100 . 6
8 Quality assurance . 13
9 Designation, marking and colours . 13
10 Delivery conditions . 14
11 Storage . 14
Bibliography . 15

2

---------------------- Page: 4 ----------------------
SIST EN 4641-100:2015
EN 4641-100:2015 (E)
European foreword
This document (EN 4641-100:2015) has been prepared by the Aerospace and Defence Industries
Association of Europe - Standardization (ASD-STAN).
After enquiries and votes carried out in accordance with the rules of this Association, this European
Standard has received the approval of the National Associations and the Official Services of the member
countries of ASD, prior to its presentation to CEN.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by March 2016, and conflicting national standards shall
be withdrawn at the latest by March 2016.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent
rights.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

3

---------------------- Page: 5 ----------------------
SIST EN 4641-100:2015
EN 4641-100:2015 (E)
1 Scope
This European Standard specifies the general characteristics, conditions for qualification, acceptance
and quality assurance for fibre optic cable: 4641-100.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
EN 2424, Aerospace series — Marking of aerospace products
EN 2812, Aerospace series — Stripping of electric cables
EN 3745 (all parts), Aerospace series — Fibres and cables, optical, aircraft use — Test methods
EN 3838, Aerospace series — Requirements and tests on user-applied markings on aircraft electrical cables
EN 3909, Aerospace series — Test fluids and test methods for electric components and sub-assemblies
EN 9133, Aerospace series — Quality management systems — Qualification procedure for aerospace
standard parts
1)
TR 6058, Aerospace series — Cable code identification list
2)
TIA/EIA-455-30-B, FOTP-30 Frequency Domain Measurement of Multimode
TIA/EIA-455-175-B, FOTP175 — Chromatic Dispersion Measurement of Single-mode Optical Fibers by the
2)
Differential Phase Shift Method
2)
ANSI/EIA 4920000-A, Generic Specification for Optical Waveguide Fibers

1) Published as ASD-STAN Technical Report at the date of publication of this European Standard.
http://www.asd-stan.org/
2) Published by: National (US) American National Standard Institute. http://www.ansi.org/
4

---------------------- Page: 6 ----------------------
SIST EN 4641-100:2015
EN 4641-100:2015 (E)
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 3745-100 apply.
4 Required characteristics
The characteristics of the cables, tested according to the methods described hereafter shall comply with
the values defined in this product standard.
5 Cable construction
See Figure 1 and Table 1.

Key
1 Core
2 Optical cladding
3 Primary coating
4 Primary jacket
5 Mechanical strength braid
6 Outer jacket
Figure 1
Table 1
Property Value
Mass ≤ 4 g/m
Operating temperature -55 °C to 125 °C
Installation: 20 mm (10 × outside diameter)
Minimum bend radius (20 °C)
Long term: 20 mm (10 × outside diameter)
Storage: 40 mm (20 × cable outside diameter)
Tensile strength > 200 N

6 Materials
See Table 2.
5

---------------------- Page: 7 ----------------------
SIST EN 4641-100:2015
EN 4641-100:2015 (E)
Table 2
Element Material
Core
Fibre Silica
Cladding
Primary coating Silicone
Primary jacket Halogen free high temperature copolymer
Mechanical strength reinforcement Polymer aromatic braid
Outer jacket High temperature copolymer

7 Test methods and performances in accordance with EN 3745-100
7.1 Optical fibre tests
See Table 3.
Table 3 — Optical fibre test methods
Test
method Designation of the test Test conditions and results
EN 3745-
201 Fibre visual examination The coating shall be continuous and free of visible defects such as lumps,
abrasions, cracks, splits or blisters.
202 Fibre core dimensions Core diameter: (62,5 ± 3) µm
202 Fibre dimension cladding diameter
Cladding diameter: (125 ± 2) µm
Method A or B
Sample should be in accordance with test methods
Number of sample: 1
202 Fibre dimension core non circularity
Core non circularity: ≤ 5 % (3 µm)
Number of sample: 1
202 Fibre dimension cladding
Cladding non circularity: ≤ 2 % (2,5 µm)
non circularity
Number of sample: 1
202 Fibre dimension concentricity error
Concentricity error: ≤ 3 µm
Number of sample: 1
301 ≤ 4 dB/km at 850 nm (20 °C)
Fibre attenuation
Method A
≤ 2 dB/km at 1 300 nm (20 °C)
302 Numerical aperture
0,275 ± 0,015
303 Bandwidth Bandwidth ≥ 160 MHz.km at 850 nm
Bandwidth ≥ 500 MHz.km at 1 300 nm
Number of sample: 1
Minimal length of the sample: 1 km
Central wavelengths: 850 nm / 1 300 nm ± 10 nm
Spectral width (− 3 dB): ≤ 10 nm for 850 nm and 1 300 nm
501 Optical fibre proof test > 1 %

6

---------------------- Page: 8 ----------------------
SIST EN 4641-100:2015
EN 4641-100:2015 (E)
7.2 Fibre optic cable
See Table 4.
Table 4 — Fibre optic cable test methods (1 of 6)
Test
method Designation of the test Test conditions and results
EN 3745-
The outer jacket shall have the correct identification as specified in this
European Standard.
201 Visual Inspection The coating shall be continuous and free of visible defects such as lumps,
abrasions, cracks, splits or blisters.
Sample length: (100 ± 0,05) m
203 Primary coating outside diameter (400 ± 25) µm
203 Buffer diameter (900 ± 25) µm
203 Outer jacket outside diameter
(1,8 ± 0,1) mm
203 Outer jacket wall thickness (0,35 ± 0,07) mm
The change in longitudinal dimensions between core/cladding and
primary jacket and core/cladding
...

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Luft- und Raumfahrt - Lichtwellenleiterkabel, Manteldurchmesser 125 µm - Teil 100: Festaderaufbau GI 62,5/125 µm Faser Kabeldurchmesser 1,8 mm - ProduktnormSérie aérospatiale - Câble, optique, diamètre extérieur de la gaine optique 125 µm - Partie 100: Câble à structure serrée fibre à gradient d’indice cœur 62,5/125 µm, diamètre extérieur 1,8 mm - Norme de produitDUG49.060Aerospace electric equipment and systems29.060.20KabliCablesICS:Ta slovenski standard je istoveten z:EN 4641-100:2015SIST EN 4641-100:2015en,fr,de01-november-2015SIST EN 4641-100:2015SLOVENSKI
STANDARD



SIST EN 4641-100:2015



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 4641-100
September
t r s w ICS
v {ä r { r English Version
Aerospace series æ Cablesá optical
s t w
Ám diameter cladding æ Part
s r rã Tight sfibre
sá z mm outside diameter æ Product standard Série aérospatiale æ Câbleá optiqueá diamètre extérieur de la gaine optique
s t w
Ám æ Partie
s r r ã Câble œ structure serrée fibre œ gradient d 5indice cœur produit
Luftæ und Raumfahrt æ Lichtwellenleiterkabelá Manteldurchmesser
s t w
Ám æ Teil
s r rã Festaderaufbau Produktnorm This European Standard was approved by CEN on
t s June
t r s vä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey andUnited Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
9
t r s w CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
v x v sæ s r rã t r s w ESIST EN 4641-100:2015



EN 4641-100:2015 (E) 2 Contents Page European foreword . 3 1 Scope . 4 2 Normative references . 4 3 Terms and definitions . 5 4 Required characteristics . 5 5 Cable construction . 5 6 Materials . 5 7 Test methods and performances in accordance with EN
u y v w-100 . 6
z Quality assurance . 13 9 Designationá marking and colours . 13 10 Delivery conditions . 14 11 Storage . 14 Bibliography . 15
SIST EN 4641-100:2015



EN 4641-100:2015 (E) 3 European foreword This document (EN 4641-100:2015) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this European Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by March 2016, and conflicting national standards shall be withdrawn at the latest by March 2016. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
SIST EN 4641-100:2015



EN 4641-100:2015 (E) 4 1 Scope This European Standard specifies the general characteristics, conditions for qualification, acceptance and quality assurance for fibre optic cable: 4641-100. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2424, Aerospace series — Marking of aerospace products EN 2812, Aerospace series — Stripping of electric cables EN 3745 (all parts), Aerospace series — Fibres and cables, optical, aircraft use — Test methods EN 3838, Aerospace series — Requirements and tests on user-applied markings on aircraft electrical cables EN 3909, Aerospace series — Test fluids and test methods for electric components and sub-assemblies EN 9133, Aerospace series — Quality management systems — Qualification procedure for aerospace standard parts TR 6058, Aerospace series — Cable code identification list 1)
TIA/EIA-455-30-B, FOTP-30 Frequency Domain Measurement of Multimode 2) TIA/EIA-455-175-B, FOTP175 — Chromatic Dispersion Measurement of Single-mode Optical Fibers by the Differential Phase Shift Method 2) ANSI/EIA 4920000-A, Generic Specification for Optical Waveguide Fibers 2)
1) Published as ASD-STAN Technical Report at the date of publication of this European Standard. http://www.asd-stan.org/ 2) Published by: National (US) American National Standard Institute. http://www.ansi.org/ SIST EN 4641-100:2015



EN 4641-100:2015 (E) 5 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 3745-100 apply. 4 Required characteristics The characteristics of the cables, tested according to the methods described hereafter shall comply with the values defined in this product standard. 5 Cable construction See Figure 1 and Table 1.
Key 1 Core
2 Optical cladding
3 Primary coating
4 Primary jacket
5 Mechanical strength braid 6 Outer jacket Figure 1 Table 1 Property Value Mass ≤ 4 g/m Operating temperature -55 °C to 125 °C Minimum bend radius (20 °C) Installation: 20 mm (10 × outside diameter) Long term: 20 mm (10 × outside diameter) Storage: 40 mm (20 × cable outside diameter) Tensile strength > 200 N
6 Materials
See Table 2. SIST EN 4641-100:2015



EN 4641-100:2015 (E) 6 Table 2 Element Material Fibre Core Silica Cladding Primary coating Silicone Primary jacket Halogen free high temperature copolymer
Mechanical strength reinforcement Polymer aromatic braid Outer jacket High temperature copolymer
7 Test methods and performances in accordance with EN
u y v w-100 7.1 Optical fibre tests See Table 3. Table 3 — Optical fibre test methods
Test method EN 3745- Designation of the test Test conditions and results 201 Fibre visual examination The coating shall be continuous and free of visible defects such as lumps, abrasions, cracks, splits or blisters. 202 Fibre core dimensions Core diameter: (62,5 ± 3) µm 202 Fibre dimension cladding diameter Cladding diameter: (125 ± 2) µm Method A or B Sample should be in accordance with test methods Number of sample: 1 202 Fibre dimension core non circularity Core non circularity: ≤ 5 % (3 µm) Number of sample: 1 202 Fibre dimension cladding non circularity Cladding non circularity: ≤ 2 % (2,5 µm) Number of sample: 1 202 Fibre dimension concentricity error Concentricity error: ≤ 3 µm Number of sample: 1 301 Method A Fibre attenuation ≤ 4 dB/km at 850 nm (20 °C) ≤ 2 dB/km at 1 300 nm (20 °C) 302 Numerical aperture 0,275 ± 0,015 303 Bandwidth Bandwidth ≥ 160 MHz.km at 850 nm Bandwidth ≥ 500 MHz.km at 1 300 nm Number of sample: 1 Minimal length of the sample: 1 km Central wavelengths: 850 nm / 1 300 nm ± 10 nm Spectral width (− 3 dB): ≤ 10 nm for 850 nm and 1 300 nm 501 Optical fibre proof test > 1 %
SIST EN 4641-100:2015



EN 4641-100:2015 (E) 7 7.2 Fibre optic cable
See Table 4. Table 4 — Fibre optic cable test methods (1 of 6) Test method EN 3745- Designation of the test Test conditions and results 201 Visual Inspection The outer jacket shall have the correct identification as specified in this European Standard. The coating shall be continuous and free of visible defects such as lumps, abrasions, cracks, splits or blisters. Sample length: (100 ± 0,05) m 203 Primary coating outside diameter (400 ± 25) µm 203 Buffer diameter (900 ± 25) µm 203 Outer jacket outside diameter (1,8 ± 0,1) mm 203 Outer jacket wall thickness (0,35 ± 0,07) mm 205 Cable longitudinal dimensional stability The change in longitudinal dimensions between core/cladding and primary jacket and core/cladding and outer jacket shall not exceed the maximum value of 200 µm. Number of samples: 4 in total, 2 for each length Length of the samples: 2 m, (20 ± 0,01) m 301 Method C Cable attenuation Visual examination in accordance with
...

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Luft- und Raumfahrt - Lichtwellenleiterkabel, Manteldurchmesser 125 µm - Teil 100: Festaderaufbau GI 62,5/125 µm Faser Kabeldurchmesser 1,8 mm - ProduktnormSérie aérospatiale - Câble, optique, diamètre extérieur de la gaine optique 125 µm - Partie 100: Câble à structure serrée fibre à gradient d’indice cœur 62,5/125 µm, diamètre extérieur 1,8 mm - Norme de produitDUG49.060Aerospace electric equipment and systemsICS:Ta slovenski standard je istoveten z:FprEN 4641-100kSIST FprEN 4641-100:2014en,fr,de01-maj-2014kSIST FprEN 4641-100:2014SLOVENSKI
STANDARD



kSIST FprEN 4641-100:2014



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
FINAL DRAFT
FprEN 4641-100
March 2014 ICS
English Version
Aerospace series - Cables, optical 125 µm diameter cladding - Part 100: Tight structure 62,5/125 µm core GI fibre 1,8 mm outside diameter - Product standard
Série aérospatiale - Câble, optique, diamètre extérieur de la gaine optique 125 µm - Partie 100: Câble à structure serrée fibre à gradient d'indice cœur 62,5/125 µm, diamètre extérieur 1,8 mm - Norme de produit
Luft- und Raumfahrt - Lichtwellenleiterkabel, Manteldurchmesser 125 µm - Teil 100: Festaderaufbau GI 62,5/125 µm Faser Kabeldurchmesser 1,8 mm - Produktnorm This draft European Standard is submitted to CEN members for formal vote. It has been drawn up by the Technical Committee ASD-STAN. If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2014 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. FprEN 4641-100:2014 EkSIST FprEN 4641-100:2014



FprEN 4641-100:2014 (E) 2 Contents Page coreword .3 1 Scope .4 2 kormative references .4 3 qerms and definitions .5 4 oequired characteristics .5 5 Cable construction .5 6 Materials .5 7 qest methods and performances in accordance with bk mqno-100 .6 8 nuality assurance . 13 9 Designationf marking and colours . 13 10 aelivery conditions . 14 11 ptorage . 14 kSIST FprEN 4641-100:2014



FprEN 4641-100:2014 (E) 3 coreword This document (FprEN 4641-100:2014) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This document is currently submitted to the Formal Vote.
kSIST FprEN 4641-100:2014



FprEN 4641-100:2014 (E) 4 1 Scope This European Standard specifies the general characteristics, conditions for qualification, acceptance and quality assurance for fibre optic cable: 4641-100. 2 kormative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2424, Aerospace series — Marking of aerospace products EN 2812, Aerospace series — Stripping of electrical cables EN 3475-511, Aerospace series — Cables, electrical, aircraft use — Test methods — Part 511: Cable-to-cable abrasion EN 3745-100 (all parts), Aerospace series — Fibres and cables, optical, aircraft use — Test methods — Part 100: General EN 3838, Aerospace series — Requirements and tests on user-applied markings on aircraft electrical cables EN 3909, Aerospace series — Test fluids and test methods for electric components and sub-assemblies EN 9133, Aerospace series — Quality management systems — Qualification procedure for aerospace standard parts TR 6058, Aerospace series — Cable code identification list 1)
ISO 1817, Rubber, vulcanized — Determination of the effect of liquids 2) TIA/EIA-455-30-B, FOTP-30 Frequency Domain Measurement of Multimode 3) TIA/EIA-455-175-B, FOTP175 — Chromatic Dispersion Measurement of Single-mode Optical Fibers by the Differential Phase Shift Method 3) ANSI/EIA 4920000-A, Generic Specification for Optical Waveguide Fibers 3)
1) Published as ASD-STAN Technical Report at the date of publication of this standard. http://www.asd-stan.org/ 2) Published by: International International Standardisation Organisation. http://www.iso.ch/ 3) Published by: National (US) American National Standard Institute. http://www.ansi.org/ kSIST FprEN 4641-100:2014



FprEN 4641-100:2014 (E) 5 3 qerms and definitions For the purposes of this document, the terms and definitions given in EN 3745-100 apply. 4 oequired characteristics The characteristics of the cables, tested according to the methods described hereafter shall comply with the values defined in this product standard. 5 Cable construction See Figure 1 and Table 1.
hey 1 Optical cladding 2 Primary jacket 3 Outer jacket 4 Mechanical strength braid 5 Primary coating 6 Core cigure 1 Table 1 mroperty salue Mass ≤ 4 g/m Operating temperature − 55 °C to 125 °C Minimum bend radius (20 °C) Installation: 20 mm (10 × outside diameter) Long term: 20 mm (10 × outside diameter) Storage: 40 mm (20 × cable outside diameter) Tensile strength > 200 N
6 Materials
See Table 2. kSIST FprEN 4641-100:2014



FprEN 4641-100:2014 (E) 6 Table 2 blement Material Fibre Core Silica Cladding Primary coating Silicone Primary jacket Halogen free high temperature copolymer
Mechanical strength reinforcement Polymer aromatic braid Outer jacket High temperature copolymer
7 qest methods and performances in accordance with bk mqno-100 7.1 Optical fibre tests See Table 3. Table 3 — lptical fibre test methods
Test method EN 3745- aesignation of the test qest conditions and results 201 Fibre visual examination The coating shall be continuous and free of visible defects such as lumps, abrasions, cracks, splits or blisters. 202 Fibre core dimensions Core diameter: (62,5 ± 3) µm 202 Fibre dimension cladding diameter Cladding diameter: (125 ± 2) µm Method A or B Sample should be in accordance with test methods Number of sample: 1 202 Fibre dimension core non circularity Core non circularity: ≤ 5 % (3 µm) Number of sample: 1 202 Fibre dimension cladding non circularity Cladding non circularity: ≤ 2 % (2,5 µm) Number of sample: 1 202 Fibre dimension concentricity error Concentricity error: ≤ 3 µm Number of sample: 1 301 Method A Fibre attenuation ≤ 4 dB/km at 850 nm (20 °C) ≤ 2 dB/km at 1300 nm (20 °C) 302 Numerical aperture 0,275 ± 0,015 303 Bandwidth Bandwidth ≥ 160 Mhz.km at 850 nm Bandwidth ≥ 500 Mhz.km at 1 300 nm Number of sample: 1 Minimal length of the sample: 1 km Central wavelengths: 850 nm /1 300 nm ± 10 nm Spectral width (− 3 dB): ≤ 10 nm for 850 nm and 1 300 nm 501 Optical fibre proof test > 1 %
kSIST FprEN 4641-100:2014



FprEN 4641-100:2014 (E) 7 7.2 Fibre optic cable
See Table 4. Table 4 — cibre optic cable test methods (1 of 6) Test method EN 3745- aesignation of the test qest conditions and results 201 Visual Inspection The outer jacket shall have the correct identification as specified in this standard. The coating shall be continuous and free of visible defects such as lumps, abrasions, cracks, splits or blisters. Sample length: (100 ± 0,05) m 203 Primary coating outside diameter (400 ± 25) µm 203 Buffer diameter (900 ± 25) µm 203 Outer jacket outside diameter (1,8 ± 0,1) mm 203 Outer jacket wall thickness (0,35 ± 0,07) mm 205 Cable longitudinal dimensional stability The change in longitudinal dimensions between core/cladding and primary jacket and core/cladding and outer jacket shall not exceed the maximum value of 200 µm. Number of samples: 4 in total, 2 for each length Length of the samples: 2 m, (20 ± 0,01) m 301 Method C Cable attenuation Visual examination in accordance with EN 3745-201 Maximum attenuation at − 55 °C and 125 °C α ≤ 0,7 dB at 850 nm a
...

Questions, Comments and Discussion