Sanitary tapware - Shower outlets for sanitary tapware for water supply systems of type 1 and type 2 - General technical specification

This European Standard specifies:
•   the dimensional, leaktightness, mechanical, hydraulic and acoustic characteristics with which shower outlets shall comply;
•   the procedures for testing these characteristics.
This European Standard applies to shower heads and hand showers of any material used for ablutionary purposes and intended for equipping and supplementing sanitary tapware for baths and showers.
This European Standard applies to shower heads and hand showers connected downstream of the obturator of the tapware.
Integral and remote spray attachments incorporated in tapware (e.g. sink and wash basin mixing valves) are not covered by this standard.

Sanitärarmaturen - Brausen für Sanitärarmaturen für Wasserversorgungssysteme vom Typ 1 und Typ 2 - Allgemeine technische Spezifikation

Diese Europäische Norm legt Folgendes fest:
-   die Maße, die Dichtheit, das mechanische, hydraulische und das Geräuschverhalten, denen Brausen genügen müssen
   die Prüfverfahren, um diese Anforderungen zu überprüfen.
Sie gilt unabhängig vom verwendeten Material für Brauseköpfe und Handbrausen für die Körperhygiene als Ausrüstung von Sanitärarmaturen in Bädern und Duschen. Sie dürfen nur nach dem Absperrorgan der Sanitärarmatur angeschlossen werden.
In die Armatur integrierte Auslauf- und Seitenbrausen (z. B. wie bei Spültischmischern) werden von dieser Norm nicht umfasst.
Die Angaben zu Druck und Temperatur sind in Tabelle 1 enthalten.

Robinetterie sanitaire - Douches pour robinetterie sanitaire pour les systemes d`alimentation type 1 et type 2 - Spécifications techniques générales

La présente Norme européenne spécifie :
- les caractéristiques dimensionnelles, d’étanchéité, de comportement mécanique, hydraulique et
acoustique auxquelles doivent répondre les douches ;
- les modes opératoires d’essai permettant de contrôler ces caractéristiques.
Elle s’applique aux douches et douchettes, quel que soit le matériau utilisé, destinées a équiper et a
compléter les robinetteries sanitaires de baignoires ou de douches réservées pour l’hygiene corporelle. Ces
flexibles doivent etre connectés seulement a l’aval de l’obturateur de la robinetterie.
Les douchettes latérales et intégrées incorporées dans les robinetteries (par exemple, robinets mitigeurs pour
évier et lavabo) ne sont pas couvertes par cette norme.
Les exigences relatives a la pression et a la température sont données dans le Tableau 1.

Sanitarne armature - Prhe za sanitarne armature sistemov za oskrbo z vodo tipa 1 in tipa 2 - Splošne tehnične zahteve

General Information

Status
Published
Publication Date
26-Nov-2008
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
21-Nov-2008
Due Date
26-Jan-2009
Completion Date
27-Nov-2008

Relations

Buy Standard

Standard
EN 1112:2009
English language
21 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Sanitärarmaturen - Brausen für Sanitärarmaturen für Wasserversorgungssysteme vom Typ 1 und Typ 2 - Allgemeine technische SpezifikationRobinetterie sanitaire - Douches pour robinetterie sanitaire pour les systemes d`alimentation type 1 et type 2 - Spécifications techniques généralesSanitary tapware - Shower outlets for sanitary tapware for water supply systems of type 1 and type 2 - General technical specification91.140.70Sanitarne napraveSanitary installationsICS:Ta slovenski standard je istoveten z:EN 1112:2008SIST EN 1112:2009en,fr,de01-januar-2009SIST EN 1112:2009SLOVENSKI
STANDARDSIST EN 13904:2004SIST EN 1112:19971DGRPHãþD



SIST EN 1112:2009



EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 1112February 2008ICS 23.040.70Supersedes EN 1112:1997, EN 13904:2003
English VersionSanitary tapware - Shower outlets for sanitary tapware for watersupply systems of type 1 and type 2 - General technicalspecificationRobinetterie sanitaire - Douches pour robinetterie sanitairepour les systèmes d`alimentation en eau de types 1 et 2 -Spécifications techniques généralesSanitärarmaturen - Brausen für Sanitärarmaturen fürWasserversorgungssysteme vom Typ 1 und Typ 2 -Allgemeine technische SpezifikationThis European Standard was approved by CEN on 12 January 2008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2008 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 1112:2008: ESIST EN 1112:2009



EN 1112:2008 (E) 2 Contents Page Foreword.4 Introduction.5 1 Scope.6 2 Normative references.9 3 Terms and definitions.9 4 Classification.9 5 Designation.10 6 Marking.10 7 Materials.10 7.1 Chemical and hygienic requirements.10 7.2 Exposed surface condition and quality of coating.10 8 Dimensional Characteristics.10 8.1 General.10 8.2 Connecting Dimensions.11 8.3 Special Cases.12 9 Leaktightness Characteristics.13 9.1 General.13 9.2 Test Method.13 9.2.1 Principle.13 9.2.2 Apparatus.13 9.2.3 Procedure.13 9.2.4 Requirements.13 10 Mechanical Characteristics.13 10.1 General.13 10.2 Mechanical Strength.14 10.2.1 Test Method.14 10.2.2 Principle.14 10.2.3 Apparatus.14 10.2.4 Procedure.14 10.2.5 Requirements.14 10.3 Thermal Shock Test.15 10.3.1 General.15 10.3.2 Principle.15 10.3.3 Apparatus.15 10.3.4 Procedure.16 10.3.5 Requirements.17 11 Hydraulic Characteristics.17 11.1 General.17 11.2 Flow rate.17 11.2.1 Test Method.17 11.2.2 Principle.17 11.2.3 Apparatus.17 11.2.4 Procedure.19 11.2.5 Requirement.19 12 Acoustic characteristics.20 SIST EN 1112:2009



EN 1112:2008 (E) 3 12.1 General.20 12.2 Procedure.20 12.3 Expression of results.20 12.4 Determination of acoustic group.20 13 Maintenance.20 14 Rotary connection.20 14.1 General.20 14.2 Test method.21 14.2.1 Principle.21 14.2.2 Apparatus.21 14.2.3 Procedure.21 14.2.4 Requirements.21
SIST EN 1112:2009



EN 1112:2008 (E) 4 Foreword This document (EN 1112:2008) has been prepared by Technical Committee CEN/TC 164 “Water supply”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by August 2008, and conflicting national standards shall be withdrawn at the latest by August 2008. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 1112:1997 and EN 13904:2003 The scope is enlarged to include requirements for shower outlets used with water supply systems of type 1 and type 2. See Tables 1, 3, 4, 5 and 7. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. SIST EN 1112:2009



EN 1112:2008 (E) 5 Introduction In respect of potential adverse effects on the quality of water intended for human consumption, caused by the product covered by this standard:
 this standard provides no information as to whether the product may be used without restriction in any
of the Member States of the EU or EFTA;  it should be noted that while awaiting the adoption of verifiable European criteria, existing national regulations concerning the use and/or the characteristics of these products remain in force. SIST EN 1112:2009



EN 1112:2008 (E) 6
1 Scope This European Standard specifies:  the dimensional, leaktightness, mechanical, hydraulic and acoustic characteristics with which shower outlets shall comply;  the procedures for testing these characteristics. This European Standard applies to shower heads and hand showers of any material used for ablutionary purposes and intended for equipping and supplementing sanitary tapware for baths and showers.
This European Standard applies to shower heads and hand showers connected downstream of the obturator of the tapware. Integral and remote spray attachments incorporated in tapware (e.g. sink and wash basin mixing valves) are not covered by this standard. Details of pressures and temperatures are given in Table 1. Table 1 — Conditions of use/Classifications Operating range of shower outlets Flow rate classes Acoustics Marking Water Supply
system Limits Recommended
See clause 12.0 See clause 6.0 ZZ (0,025 ≤ Q < 0,12) l/s (1,5 ≤ Q <
7,2) l/min Z (0,12 ≤ Q < 0,20) l/s (7,2 ≤ Q < 12) l/min
A (0,20 ≤ Q < 0,25) l/s (12 ≤ Q < 15) l/min S (0,25 ≤ Q < 0,33) l/s (15 ≤ Q < 20) l/min B (0,33 ≤ Q < 0,42) l/s (20 ≤ Q < 25) l/min C (0,42 ≤ Q < 0,50) l/s (25 ≤ Q < 30) l/min Type 1
see Figure 1 Dynamic Pressure
(0,05 to 0,5) MPa
(0,5 to 5) bar
Dynamic Pressure
(0,1 to 0,3) MPa
(1,0 to 3) bar
D (0,50 ≤ Q < 0,63) l/s (30 ≤ Q < 38) l/min Group I
Group II
for example I A II B
E (0,06 ≤ Q < 0,14) l/s (3,6 ≤ Q < 8,4) l/min at (0,01) MPa (0,1 bar) Type 2
see Figure 2 Dynamic Pressure (0,01 to 0,2) MPa (0,1 to 2) bar
Dynamic
Pressure (0,02 to 0,1) MPa (0,2 to 1) bar
H (Q ≥ 0,14) l/s (Q ≥ 8,4) l/min at (0,01) MPa (0,1 bar) (unclassified)
Temperature T < 70°C T < 42°C
SIST EN 1112:2009



EN 1112:2008 (E) 7
Key 1 Cold water 2 Hot Water 3 Mains supply pipe (Supply pressures up to 10 bar)
4 Water heater Figure 1 — Type 1 Water supply system with a pressu
...