Environmental Engineering (EE) - Environmental conditions and environmental tests for telecommunications equipment - Part 2-1: Specification of environmental tests - Storage

The present document specifies test severities and methods for verification of the required resistibility of equipment
according to the relevant environmental class.
The tests defined in the present document apply to storage of equipment covering the environmental conditions stated in
ETSI EN 300 019-1-1 [1].

Okoljski inženiring (EE) - Okoljski pogoji in preskusi vplivov okolja na telekomunikacijsko opremo - 2-1. del: Specifikacija preskusov vplivov okolja - Skladiščenje

Ta dokument določa natančnost preskusov in metode za preverjanje zahtevane odpornosti opreme glede na ustrezen okoljski razred.
Preskusi, opredeljeni v tem dokumentu, se uporabljajo za skladiščenje opreme, ki jo zajemajo okoljski pogoji iz standarda ETSI EN 300 019-1-1 [1].

General Information

Status
Published
Public Enquiry End Date
26-Nov-2017
Publication Date
17-Dec-2017
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
04-Dec-2017
Due Date
08-Feb-2018
Completion Date
18-Dec-2017

Buy Standard

Standard
EN 300 019-2-1 V2.3.1:2018
English language
22 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
ETSI EN 300 019-2-1 V2.3.1 (2017-11) - Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-1: Specification of environmental tests; Storage
English language
22 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ETSI EN 300 019-2-1 V2.2.8 (2017-08) - Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-1: Specification of environmental tests; Storage
English language
22 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 300 019-2-1 V2.3.1:2018
01-februar-2018
2NROMVNLLQåHQLULQJ (( 2NROMVNLSRJRMLLQSUHVNXVLYSOLYRYRNROMDQD
WHOHNRPXQLNDFLMVNRRSUHPRGHO6SHFLILNDFLMDSUHVNXVRYYSOLYRYRNROMD
6NODGLãþHQMH
Environmental Engineering (EE) - Environmental conditions and environmental tests for
telecommunications equipment - Part 2-1: Specification of environmental tests - Storage
Ta slovenski standard je istoveten z: ETSI EN 300 019-2-1 V2.3.1 (2017-11)
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
SIST EN 300 019-2-1 V2.3.1:2018 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 300 019-2-1 V2.3.1:2018

---------------------- Page: 2 ----------------------

SIST EN 300 019-2-1 V2.3.1:2018
ETSI EN 300 019-2-1 V2.3.1 (2017-11)






EUROPEAN STANDARD
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 2-1: Specification of environmental tests;
Storage

---------------------- Page: 3 ----------------------

SIST EN 300 019-2-1 V2.3.1:2018
 2 ETSI EN 300 019-2-1 V2.3.1 (2017-11)



Reference
REN/EE-0170
Keywords
environment, equipment practice, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88

Important notice
The present document can be downloaded from:
http://www.etsi.org/standards-search
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the
print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
https://portal.etsi.org/TB/ETSIDeliverableStatus.aspx
If you find errors in the present document, please send your comment to one of the following services:
https://portal.etsi.org/People/CommiteeSupportStaff.aspx
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying
and microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.

© ETSI 2017.
All rights reserved.

TM TM TM
DECT , PLUGTESTS , UMTS and the ETSI logo are trademarks of ETSI registered for the benefit of its Members.
TM
3GPP and LTE™ are trademarks of ETSI registered for the benefit of its Members and
of the 3GPP Organizational Partners.
oneM2M logo is protected for the benefit of its Members.
GSM® and the GSM logo are trademarks registered and owned by the GSM Association.
ETSI

---------------------- Page: 4 ----------------------

SIST EN 300 019-2-1 V2.3.1:2018
 3 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
Contents
Intellectual Property Rights . 4
Foreword . 4
Modal verbs terminology . 5
1 Scope . 6
2 References . 6
2.1 Normative references . 6
2.2 Informative references . 6
3 Definitions . 7
4 Environmental test specifications . 7
4.0 General . 7
4.1 Equipment setup and configuration . 7
4.2 Performance criteria . 7
4.3 Specification T 1.1: Weatherprotected, partly temperature-controlled storage locations . 8
4.4 Specification T 1.2: Weatherprotected, not temperature-controlled storage locations . 11
4.5 Specification T 1.3: Non-weatherprotected storage locations and T 1.3 E: Non-weatherprotected storage
locations - extended . 14
Annex A (informative): Bibliography . 21
History . 22

ETSI

---------------------- Page: 5 ----------------------

SIST EN 300 019-2-1 V2.3.1:2018
 4 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
Intellectual Property Rights
Essential patents
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (https://ipr.etsi.org/).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Trademarks
The present document may include trademarks and/or tradenames which are asserted and/or registered by their owners.
ETSI claims no ownership of these except for any which are indicated as being the property of ETSI, and conveys no
right to use or reproduce any trademark and/or tradename. Mention of those trademarks in the present document does
not constitute an endorsement by ETSI of products, services or organizations associated with those trademarks.
Foreword
This European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE).
The present document is part 2, sub-part 1 of a multi-part deliverable covering the environmental conditions and
environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions";
Part 2: "Specification of environmental tests":
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations".
Part 1 specifies different standardized environmental classes covering climatic and biological conditions, chemically
and mechanically active substances and mechanical conditions during storage, transportation and in use.
Part 2 specifies the recommended test severities and test methods for the different environmental classes.

ETSI

---------------------- Page: 6 ----------------------

SIST EN 300 019-2-1 V2.3.1:2018
 5 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
National transposition dates
Date of adoption of this EN: 27 November 2017
Date of latest announcement of this EN (doa): 28 February 2018
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 31 August 2018
Date of withdrawal of any conflicting National Standard (dow): 31 August 2018

Modal verbs terminology
In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and
"cannot" are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of
provisions).
"must" and "must not" are NOT allowed in ETSI deliverables except when used in direct citation.
ETSI

---------------------- Page: 7 ----------------------

SIST EN 300 019-2-1 V2.3.1:2018
 6 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
1 Scope
The present document specifies test severities and methods for verification of the required resistibility of equipment
according to the relevant environmental class.
The tests defined in the present document apply to storage of equipment covering the environmental conditions stated in
ETSI EN 300 019-1-1 [1].
2 References
2.1 Normative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
https://docbox.etsi.org/Reference/.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
The following referenced documents are necessary for the application of the present document.
[1] ETSI EN 300 019-1-1 (2014): "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-1: Classification of environmental
conditions; Storage".
[2] Void.
[3] Void.
[4] IEC 60068-2-1:2007: "Environmental testing - Part 2-1: Tests - Test A: Cold".
[5] IEC 60068-2-2:2007: "Environmental testing - Part 2-2: Tests - Test B: Dry heat".
[6] IEC 60068-2-6:2007: "Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)".
[7] IEC 60068-2-14:2009: "Environmental testing - Part 2-14: Tests - Test N: Change of temperature".
[8] IEC 60068-2-18:2017: "Environmental testing - Part 2-18: Tests - Test R and guidance: Water".
[9] IEC 60068-2-27:2008: "Environmental testing. Part 2-27: Tests - Test Ea and guidance: Shock".
[10] IEC 60068-2-30:2005: "Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic
(12 + 12 hour cycle)".
[11] IEC 60068-2-78:2012: "Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady
state".
[12] IEC 60068-2-64:2008: "Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband
random and guidance".
2.2 Informative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
ETSI

---------------------- Page: 8 ----------------------

SIST EN 300 019-2-1 V2.3.1:2018
 7 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
The following referenced documents are not necessary for the application of the present document but they assist the
user with regard to a particular subject area.
[i.1] ETSI EN 300 019-2-0 (2003): "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 2-0: Specification of environmental
tests; Introduction".
[i.2] IEC 60068-2-68:1994: "Environmental testing - Part 2-68: Tests - Test L: Dust and sand".
[i.3] ETSI EN 300 019-1-0: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-0: Classification of environmental
conditions; Introduction".
3 Definitions
For the purposes of the present document, the terms and definitions given in ETSI EN 300 019-1-0 [i.3] apply.
4 Environmental test specifications
4.0 General
The equipment shall be tested in the state in which it is normally stored where this is possible. For example, if the
detailed descriptions of the environmental conditions are given in clauses 4 and 5 of ETSI EN 300 019-1-1 [1].
ETSI EN 300 019-2-0 [i.1] forms a general overview of part 2 of this multi-part deliverable.
If the equipment is normally stored in a packed state then it shall be tested in its packaging.
4.1 Equipment setup and configuration
The equipment shall be tested in the state in which it is normally stored where this is possible. For example, if the
equipment is stored in a packed state, then it shall be tested in its packaging. If the equipment can be stored both with
and without its packaging it is necessary to perform tests for both configurations. For some tests and equipment, the test
may be more severe for the packaged rather than the unpacked equipment. For example, for an equipment in a sealed
package, the change of temperature test may produce condensation.
4.2 Performance criteria
The following performance criterion A shall apply in the tests defined by the present document.
Performance criterion A:
The equipment, or piece of equipment, shall be verified before and after the tests. The equipment shall function
according to the manufacturer specifications before and after the test. No electrical or mechanical damages shall be
allowed due to the application of the tests.
ETSI

---------------------- Page: 9 ----------------------

SIST EN 300 019-2-1 V2.3.1:2018
 8 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
4.3 Specification T 1.1: Weatherprotected, partly temperature-controlled storage locations
The specifications in tables 1 and 2 shall apply to weatherprotected or partially weather-controlled storage locations having partially temperature or humidity control described
in ETSI EN 300 019-1-1 [1].
Table 1: Test specification T 1.1: Weatherprotected, partly temperature-controlled storage locations - climatic tests
Environmental parameter Environmental Environmental test specification T1.1: Weatherprotected,
Class 1.1 partly temperature-controlled storage locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
Severity criteria
low (°C) -5 -5 72 h IEC 60068-2-1 [4] Ab: Cold A
Air high (°C) +45 +45 or +55 72 h IEC 60068-2-2 [5] Bb: Dry heat A 1
temperature
change (°C/min) 0,5 None   2
 low (%) 5 None   7
relative high (%) 95 93 96 h IEC 60068-2-78 [11] Cab: Damp heat A 3
steady state
(°C) +30
Humidity condensation Yes None   4
3

absolute 1 None   7
low (g/m )
3
 29   5
high (g/m )
pressure low (kPa) 70 None   6
Air high (kPa) 106 None   6
speed (m/s) 1 None   7
rain intensity no
Water low temperature no
other sources no
icing & frosting yes None   7
2
Radiation solar 700 None   8
(W/m )
2
heat 600 None   8
(W/m )
ETSI

---------------------- Page: 10 ----------------------

SIST EN 300 019-2-1 V2.3.1:2018
 9 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
Environmental parameter Environmental Environmental test specification T1.1: Weatherprotected,
Class 1.1 partly temperature-controlled storage locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
Severity criteria
3
sulphur 0,3/1,0 None   9

SO (mg/m )
2
3
 0,1/0,5 None   9
HS (mg/m )
2
 Salts sea and road salt mist None   9
3
Chemically chlorine 0,1/0,3 None   9
Cl (mg/m )
2
3
active 0,1/0,5 None   9
HCI (mg/m )
3
substances nitrogen 0,5/1,0 None   9
NO (mg/m )
x
3
 1,0/3,0 None   9
NH (mg/m )
3
3
hydrogen fluoride 0,01/0,03 None   9
HF (mg/m )
3
ozone 0,05/0,1 None   9
O (mg/m )
3
Mechanically dust Sedimentation 1,5 None   10
2
(mg/(m h))
3
active 0,2 None   10
suspension (mg/m )
3
substances sand 30 None   10
(mg/m )
Flora and micro organisms negligible
Fauna rodents, insects negligible
Legenda: no = this condition does not occur in this class.
NOTE 1: (Air temperature, high) Two test temperatures are given. The lower temperature shall apply if the equipment is protected against solar radiation.
NOTE 2: The characteristic severity value is considered to have insignificant effect on the equipment and therefore no test is required.
NOTE 3: (Humidity, relative high) These severities are the nearest IEC test temperature values, which according to the climatogram can be achieved in the relative
humidity given in the table. This test is recommended for unpacked equipment only.
NOTE 4: This characteristic severity corresponds to the high value of relative humidity and small temperature variation within the equipment and is considered to be
covered by test IEC 60068-2-78 [11] Test Cab. Therefore, no additional tests are required.
NOTE 5: This effect is considered to be partly included in test IEC 60068-2-78 [11] Test Cab and/or test IEC 60068-2-30 [10] Test Db. Therefore, no additional tests
are required.
NOTE 6: (Air pressure, low and high) No test is required at equipment level or on sub-assemblies of it, because the effect of air pressure is evaluated at the
component level.
NOTE 7: The characteristic severity value is considered to have insignificant effect on the equipment in storage conditions and furthermore there is no IEC test method
for this parameter, therefore no test is required.
NOTE 8: (Radiation, solar, heat)The heating effect of solar radiation is included in the higher test temperature in IEC 60068-2-2 [5] Test Bb as described in note 2.
Photochemical tests can be made separately for components and materials. No test is required in the present document.
NOTE 9: (Chemically active substances) Characteristic severities are mean/maximum values. The characteristic severities should be considered when choosing
components and materials. No test is required in the present document.
NOTE 10: (Mechanically active substances) For mechanically active substances the packaging is supposed to protect the equipment against dust and sand where
needed, therefore no test is required. Furthermore, the levels of dust, both sedimentation and suspension, are far lower than the lowest severity
recommended in IEC 60068-2-68 [i.2] Test Lb.

ETSI

---------------------- Page: 11 ----------------------

SIST EN 300 019-2-1 V2.3.1:2018
 10 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
Table 2: Test specification T 1.1: Weatherprotected, partly temperature-controlled storage locations - mechanical tests
Environmental parameter Environmental Environmental test specification T 1.1: Weatherprotected,
Class 1.1 partly temperature-controlled storage locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
severity criteria
Fc: Vibration
 velocity (mm/s) 5 IEC 60068-2-6 [6] A 1
(sinusoidal)
 displacement (mm) 1,5
2
sinusoidal 5 2
acceleration (m/s )
2 - 9 9 - 200 5 - 62 62 - 200 3 x 5
frequency range (Hz)
sweep
Vibration 3
axes of vibration
cycles
2 3 IEC 60068-2-64 [12] Fh: Vibration,
  0,02 A 2
ASD (m /s )
broad-band
random +12 -12 3 x 30
(dB/oct)
random
minutes
5 - 10; 10 - 50; 50 - 100
frequency range (Hz)
(digital control)
3
axes of vibration
Shocks shocks shock spectrum Type L None   3
duration (ms) 22
2
40
acceleration (m/s )
number of shocks
directions of shocks
Load static load (kPa) 5 None   4
Legenda: no = this condition does not occur in this class.
NOTE 1: (Vibration, sinusoidal) The characteristic severities are given as peak values. The test severity values defined for this phenomenon are not specified in
IEC 60068-2-6 [6].
NOTE 2: (Vibration, random) ASD (Acceleration Spectral Density). Random vibration testing method may be used instead of the sinusoidal vibration test. The test severity
values are not specified in IEC 60068-2-64 [12]. The maximum test frequency has been reduced because between 100 Hz and 200 Hz the contribution is
insignificant.
classes: 1.1 and 1.2 class: 1.3
2 2
Acceleration RMS
1,06 m/s 1,5 m/s
(for information only)

NOTE 3: (Shocks) No test is required because this condition is covered by transportation test for packaged equipment and by in-use test for unpackaged equipment.
NOTE 4: (Load) Packaging and/or equipment should be designed taking into account this requirement but no tests are required.

ETSI

---------------------- Page: 12 ----------------------

SIST EN 300 019-2-1 V2.3.1:2018
 11 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
4.4 Specification T 1.2: Weatherprotected, not temperature-controlled storage locations
The specifications in tables 3 and 4 shall apply to weatherprotected or partially weatherprotected storage locations having neither temperature nor humidity control described in
ETSI EN 300 019-1-1 [1].
Table 3: Test specification T 1.2: Weatherprotected, not temperature-controlled storage locations - climatic tests
Environmental parameter Environmental Environmental test specification T1.2: Weatherprotected,
Class 1.2 not temperature-controlled storage locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
severity criterion
low (°C) -25 -25 72 h IEC 60068-2-1 [4] Ab: Cold A
Air high (°C) +55 +55 or +70 72 h IEC 60068-2-2 [5] Bb: Dry heat A 1
temperature change (°C/min) 0,5 None   2
 low (%) 10 None   8
 high (%) 100 93 96 h IEC 60068-2-78 [11] Cab: Damp A 3
heat steady
relative (°C) +30
state
Humidity condensation yes   A 5
(%) 90-100 2 cycles IEC 60068-2-30 [10] Db: Damp heat
cyclic
(°C) +30
Variant 1
3
absolute 0,5 None   8
low (g/m )
3
 29 None   4
high (g/m )
pressure low (kPa) 70 None   7
Air high (kPa) 106 None   7
speed (m/s) 30 None   8
rain intensity no
Water low temperature no
other sources dripping water None   6
icing & frosting yes None   8
2
Radiation solar 1 120 None   9
(W/m )
2
heat 600 None   9
(W/m )
ETSI

---------------------- Page: 13 ----------------------

SIST EN 300 019-2-1 V2.3.1:2018
 12 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
Environmental parameter Environmental Environmental test specification T1.2: Weatherprotected,
Class 1.2 not temperature-controlled storage locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
severity criterion
30,3/1,0 None   10

sulphur
SO (mg/m )
3
30,1/0,5 None   10

HS (mg/m )
2
sea and road salt mist None   10
 salts
30,1/0,3 None   10
Chemically chlorine
Cl (mg/m )
2
30,1/0,5 None   10
Active
HCl (mg/m )
30,5/1,0 None   10
substances nitrogen
NO (mg/m )
x
31,0/3,0 None   10

NH (mg/m )
3
30,01/0,03 None   10
hydrogen fluoride
HF (mg/m )
30,05/0,1 None   10
ozone
O (mg/m )
3
20 None   11
Mechanically dust sedimentation
2
(mg/(m h))
35,0 None   11
Active
suspension (mg/m )
3300 None   11
substances sand
(mg/m )
Flora and micro organisms mould, fungus, etc. None   12
Fauna rodents, insects rodents, etc. None   12
Legenda: no = this condition does not occur in this class.
NOTE 1: (Air temperature, high) Two test temperatures are given. The lower temperature shall apply if the equipment is protected against solar radiation.
NOTE 2: The characteristic severity value is considered to have insignificant effect on the equipment and therefore no test is required.
NOTE 3: (Humidity, relative high) These severities are the nearest IEC test temperature values, which according to the climatogram can be achieved in the relative humidity
given in the table. This test is recommended for unpacked equipment only.
NOTE 4: This characteristic severity corresponds to the high value of relative humidity and small temperature variation within the equipment and is considered to be
covered by test IEC 60068-2-78 [11] Test Cab. Therefore, no additional tests are required.
NOTE 5: (Humidity, relative, condensation) IEC 60068-2-30 [10] Test Db is recommended with test severities not higher than climatogram limits for this class.
NOTE 6: This effect is considered to be partly included in test IEC 60068-2-78 [11] Test Cab and/or test IEC 60068-2-30 [10] Test Db. Therefore, no additional tests are
required.
NOTE 7: (Air pressure, low and high) No test is required at equipment level or on sub-assemblies of it, because the effect of air pressure is evaluated at the component
level.
NOTE 8: The characteristic severity value is considered to have insignificant effect on the equipment in storage conditions and furthermore there is no IEC test method for
this parameter, therefore no test is required.
NOTE 9: (Radiation, solar, heat) The heating effect of solar radiation is included in the higher test temperature in IEC 60068-2-2 [5] Test Bb as described in note 2.
Photochemical tests can be made separately for components and materials. No test is required in the present document.
NOTE 10: (Chemically active substances) Characteristic severities are mean/maximum values. The characteristic severities should be considered when choosing
components and materials. No test is required in the present document.
NOTE 11: (Mechanically active substances) For mechanically active substances the packaging is supposed to protect the equipment against dust and sand where needed,
therefore no test is required. Furthermore, the levels of dust, both sedimentation and suspension, are far lower than the lowest severity recommended in
IEC 60068-2-68 [i.2] Test Lb.
NOTE 12: (Flora and fauna) The characteristic severities should be considered when choosing components and materials but no test is required at the equipment level.
ETSI

---------------------- Page: 14 ----------------------

SIST EN 300 019-2-1 V2.3.1:2018
 13 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
Table 4: Test specification T 1.2: Weatherprotected, not temperature-controlled storage locations - mechanical tests
Environmental parameter Environmental Environmental test specification T1.2: Weatherprotected
Class 1.2 not temperature-controlled storage locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
Severity criteria
Fc: Vibration
 velocity (mm/s) 5 IEC 60068-2-6 [6] A 1
(sinusoidal)
 displacement (mm) 1,5
2
sinusoidal 5 2
acceleration (m/s )
2 - 9 9 - 200 5 - 62 62 - 200 3 x 5 sweep
frequency range (Hz)
cycles
Vibration 3
axes of vibration
2 3 IEC 60068-2-64 [12] Fh: Vibration,
  0,02 A 2
ASD (m /s )
broad-band
random +12 -12 3 x 30 minutes
(dB/oct)
random
5 - 10; 10 - 50; 50 - 100
frequency range (Hz)
(digital control)
3
axes of vibration
 shock spectrum Type L   3
Shocks shocks duration (ms) 22
2
40 None
acceleration (m/s )
number of shocks
directions of shocks
Load static load  (kPa) 5 None   4
Legenda: no = this condition does not occur in this class.
NOTE 1: (Vibration, sinusoidal) The characteristic severities are given as peak values. The test severity values defined for this phenomenon are not specified in
IEC 60068-2-6 [6].
NOTE 2: (Vibration, random) ASD (Acceleration Spectral Density). Random vibration testing method may be used instead of the sinusoidal vibration test. The test severity
values are not specified in IEC 60068-2-64 [12]. The maximum test frequency has been reduced because between 100 Hz and 200 Hz the contribution is insignificant.

classes: 1.1 and 1.2 class: 1.3
2 2
Acceleration RMS
1,06 m/s 1,5 m/s
(for information only)

NOTE 3: (Shocks) No test is required because this condition is covered by transportation test for packaged equipment and by in-use test for unpackaged equipment.
NOTE 4: (Load) Packaging and/or equipment should be designed taking into account this requirement but no tests are required.

ETSI

---------------------- Page: 15 ----------------------

SIST EN 300 019-2-1 V2.3.1:2018
 14 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
4.5 Specification T 1.3: Non-weatherprotected storage locations and T 1.3 E:
Non-weatherprotected st
...

ETSI EN 300 019-2-1 V2.3.1 (2017-11)






EUROPEAN STANDARD
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 2-1: Specification of environmental tests;
Storage

---------------------- Page: 1 ----------------------
2 ETSI EN 300 019-2-1 V2.3.1 (2017-11)



Reference
REN/EE-0170
Keywords
environment, equipment practice, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88

Important notice
The present document can be downloaded from:
http://www.etsi.org/standards-search
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the
print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
https://portal.etsi.org/TB/ETSIDeliverableStatus.aspx
If you find errors in the present document, please send your comment to one of the following services:
https://portal.etsi.org/People/CommiteeSupportStaff.aspx
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying
and microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.

© ETSI 2017.
All rights reserved.

TM TM TM
DECT , PLUGTESTS , UMTS and the ETSI logo are trademarks of ETSI registered for the benefit of its Members.
TM
3GPP and LTE™ are trademarks of ETSI registered for the benefit of its Members and
of the 3GPP Organizational Partners.
oneM2M logo is protected for the benefit of its Members.
GSM® and the GSM logo are trademarks registered and owned by the GSM Association.
ETSI

---------------------- Page: 2 ----------------------
3 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
Contents
Intellectual Property Rights . 4
Foreword . 4
Modal verbs terminology . 5
1 Scope . 6
2 References . 6
2.1 Normative references . 6
2.2 Informative references . 6
3 Definitions . 7
4 Environmental test specifications . 7
4.0 General . 7
4.1 Equipment setup and configuration . 7
4.2 Performance criteria . 7
4.3 Specification T 1.1: Weatherprotected, partly temperature-controlled storage locations . 8
4.4 Specification T 1.2: Weatherprotected, not temperature-controlled storage locations . 11
4.5 Specification T 1.3: Non-weatherprotected storage locations and T 1.3 E: Non-weatherprotected storage
locations - extended . 14
Annex A (informative): Bibliography . 21
History . 22

ETSI

---------------------- Page: 3 ----------------------
4 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
Intellectual Property Rights
Essential patents
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (https://ipr.etsi.org/).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Trademarks
The present document may include trademarks and/or tradenames which are asserted and/or registered by their owners.
ETSI claims no ownership of these except for any which are indicated as being the property of ETSI, and conveys no
right to use or reproduce any trademark and/or tradename. Mention of those trademarks in the present document does
not constitute an endorsement by ETSI of products, services or organizations associated with those trademarks.
Foreword
This European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE).
The present document is part 2, sub-part 1 of a multi-part deliverable covering the environmental conditions and
environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions";
Part 2: "Specification of environmental tests":
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations".
Part 1 specifies different standardized environmental classes covering climatic and biological conditions, chemically
and mechanically active substances and mechanical conditions during storage, transportation and in use.
Part 2 specifies the recommended test severities and test methods for the different environmental classes.

ETSI

---------------------- Page: 4 ----------------------
5 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
National transposition dates
Date of adoption of this EN: 27 November 2017
Date of latest announcement of this EN (doa): 28 February 2018
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 31 August 2018
Date of withdrawal of any conflicting National Standard (dow): 31 August 2018

Modal verbs terminology
In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and
"cannot" are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of
provisions).
"must" and "must not" are NOT allowed in ETSI deliverables except when used in direct citation.
ETSI

---------------------- Page: 5 ----------------------
6 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
1 Scope
The present document specifies test severities and methods for verification of the required resistibility of equipment
according to the relevant environmental class.
The tests defined in the present document apply to storage of equipment covering the environmental conditions stated in
ETSI EN 300 019-1-1 [1].
2 References
2.1 Normative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
https://docbox.etsi.org/Reference/.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
The following referenced documents are necessary for the application of the present document.
[1] ETSI EN 300 019-1-1 (2014): "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-1: Classification of environmental
conditions; Storage".
[2] Void.
[3] Void.
[4] IEC 60068-2-1:2007: "Environmental testing - Part 2-1: Tests - Test A: Cold".
[5] IEC 60068-2-2:2007: "Environmental testing - Part 2-2: Tests - Test B: Dry heat".
[6] IEC 60068-2-6:2007: "Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)".
[7] IEC 60068-2-14:2009: "Environmental testing - Part 2-14: Tests - Test N: Change of temperature".
[8] IEC 60068-2-18:2017: "Environmental testing - Part 2-18: Tests - Test R and guidance: Water".
[9] IEC 60068-2-27:2008: "Environmental testing. Part 2-27: Tests - Test Ea and guidance: Shock".
[10] IEC 60068-2-30:2005: "Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic
(12 + 12 hour cycle)".
[11] IEC 60068-2-78:2012: "Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady
state".
[12] IEC 60068-2-64:2008: "Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband
random and guidance".
2.2 Informative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
ETSI

---------------------- Page: 6 ----------------------
7 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
The following referenced documents are not necessary for the application of the present document but they assist the
user with regard to a particular subject area.
[i.1] ETSI EN 300 019-2-0 (2003): "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 2-0: Specification of environmental
tests; Introduction".
[i.2] IEC 60068-2-68:1994: "Environmental testing - Part 2-68: Tests - Test L: Dust and sand".
[i.3] ETSI EN 300 019-1-0: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-0: Classification of environmental
conditions; Introduction".
3 Definitions
For the purposes of the present document, the terms and definitions given in ETSI EN 300 019-1-0 [i.3] apply.
4 Environmental test specifications
4.0 General
The equipment shall be tested in the state in which it is normally stored where this is possible. For example, if the
detailed descriptions of the environmental conditions are given in clauses 4 and 5 of ETSI EN 300 019-1-1 [1].
ETSI EN 300 019-2-0 [i.1] forms a general overview of part 2 of this multi-part deliverable.
If the equipment is normally stored in a packed state then it shall be tested in its packaging.
4.1 Equipment setup and configuration
The equipment shall be tested in the state in which it is normally stored where this is possible. For example, if the
equipment is stored in a packed state, then it shall be tested in its packaging. If the equipment can be stored both with
and without its packaging it is necessary to perform tests for both configurations. For some tests and equipment, the test
may be more severe for the packaged rather than the unpacked equipment. For example, for an equipment in a sealed
package, the change of temperature test may produce condensation.
4.2 Performance criteria
The following performance criterion A shall apply in the tests defined by the present document.
Performance criterion A:
The equipment, or piece of equipment, shall be verified before and after the tests. The equipment shall function
according to the manufacturer specifications before and after the test. No electrical or mechanical damages shall be
allowed due to the application of the tests.
ETSI

---------------------- Page: 7 ----------------------
8 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
4.3 Specification T 1.1: Weatherprotected, partly temperature-controlled storage locations
The specifications in tables 1 and 2 shall apply to weatherprotected or partially weather-controlled storage locations having partially temperature or humidity control described
in ETSI EN 300 019-1-1 [1].
Table 1: Test specification T 1.1: Weatherprotected, partly temperature-controlled storage locations - climatic tests
Environmental parameter Environmental Environmental test specification T1.1: Weatherprotected,
Class 1.1 partly temperature-controlled storage locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
Severity criteria
low (°C) -5 -5 72 h IEC 60068-2-1 [4] Ab: Cold A
Air high (°C) +45 +45 or +55 72 h IEC 60068-2-2 [5] Bb: Dry heat A 1
temperature
change (°C/min) 0,5 None   2
 low (%) 5 None   7
relative high (%) 95 93 96 h IEC 60068-2-78 [11] Cab: Damp heat A 3
steady state
(°C) +30
Humidity condensation Yes None   4
3

absolute 1 None   7
low (g/m )
3
 29   5
high (g/m )
pressure low (kPa) 70 None   6
Air high (kPa) 106 None   6
speed (m/s) 1 None   7
rain intensity no
Water low temperature no
other sources no
icing & frosting yes None   7
2
Radiation solar 700 None   8
(W/m )
2
heat 600 None   8
(W/m )
ETSI

---------------------- Page: 8 ----------------------
9 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
Environmental parameter Environmental Environmental test specification T1.1: Weatherprotected,
Class 1.1 partly temperature-controlled storage locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
Severity criteria
3
sulphur 0,3/1,0 None   9

SO (mg/m )
2
3
 0,1/0,5 None   9
HS (mg/m )
2
 Salts sea and road salt mist None   9
3
Chemically chlorine 0,1/0,3 None   9
Cl (mg/m )
2
3
active 0,1/0,5 None   9
HCI (mg/m )
3
substances nitrogen 0,5/1,0 None   9
NO (mg/m )
x
3
 1,0/3,0 None   9
NH (mg/m )
3
3
hydrogen fluoride 0,01/0,03 None   9
HF (mg/m )
3
ozone 0,05/0,1 None   9
O (mg/m )
3
Mechanically dust Sedimentation 1,5 None   10
2
(mg/(m h))
3
active 0,2 None   10
suspension (mg/m )
3
substances sand 30 None   10
(mg/m )
Flora and micro organisms negligible
Fauna rodents, insects negligible
Legenda: no = this condition does not occur in this class.
NOTE 1: (Air temperature, high) Two test temperatures are given. The lower temperature shall apply if the equipment is protected against solar radiation.
NOTE 2: The characteristic severity value is considered to have insignificant effect on the equipment and therefore no test is required.
NOTE 3: (Humidity, relative high) These severities are the nearest IEC test temperature values, which according to the climatogram can be achieved in the relative
humidity given in the table. This test is recommended for unpacked equipment only.
NOTE 4: This characteristic severity corresponds to the high value of relative humidity and small temperature variation within the equipment and is considered to be
covered by test IEC 60068-2-78 [11] Test Cab. Therefore, no additional tests are required.
NOTE 5: This effect is considered to be partly included in test IEC 60068-2-78 [11] Test Cab and/or test IEC 60068-2-30 [10] Test Db. Therefore, no additional tests
are required.
NOTE 6: (Air pressure, low and high) No test is required at equipment level or on sub-assemblies of it, because the effect of air pressure is evaluated at the
component level.
NOTE 7: The characteristic severity value is considered to have insignificant effect on the equipment in storage conditions and furthermore there is no IEC test method
for this parameter, therefore no test is required.
NOTE 8: (Radiation, solar, heat)The heating effect of solar radiation is included in the higher test temperature in IEC 60068-2-2 [5] Test Bb as described in note 2.
Photochemical tests can be made separately for components and materials. No test is required in the present document.
NOTE 9: (Chemically active substances) Characteristic severities are mean/maximum values. The characteristic severities should be considered when choosing
components and materials. No test is required in the present document.
NOTE 10: (Mechanically active substances) For mechanically active substances the packaging is supposed to protect the equipment against dust and sand where
needed, therefore no test is required. Furthermore, the levels of dust, both sedimentation and suspension, are far lower than the lowest severity
recommended in IEC 60068-2-68 [i.2] Test Lb.

ETSI

---------------------- Page: 9 ----------------------
10 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
Table 2: Test specification T 1.1: Weatherprotected, partly temperature-controlled storage locations - mechanical tests
Environmental parameter Environmental Environmental test specification T 1.1: Weatherprotected,
Class 1.1 partly temperature-controlled storage locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
severity criteria
Fc: Vibration
 velocity (mm/s) 5 IEC 60068-2-6 [6] A 1
(sinusoidal)
 displacement (mm) 1,5
2
sinusoidal 5 2
acceleration (m/s )
2 - 9 9 - 200 5 - 62 62 - 200 3 x 5
frequency range (Hz)
sweep
Vibration 3
axes of vibration
cycles
2 3 IEC 60068-2-64 [12] Fh: Vibration,
  0,02 A 2
ASD (m /s )
broad-band
random +12 -12 3 x 30
(dB/oct)
random
minutes
5 - 10; 10 - 50; 50 - 100
frequency range (Hz)
(digital control)
3
axes of vibration
Shocks shocks shock spectrum Type L None   3
duration (ms) 22
2
40
acceleration (m/s )
number of shocks
directions of shocks
Load static load (kPa) 5 None   4
Legenda: no = this condition does not occur in this class.
NOTE 1: (Vibration, sinusoidal) The characteristic severities are given as peak values. The test severity values defined for this phenomenon are not specified in
IEC 60068-2-6 [6].
NOTE 2: (Vibration, random) ASD (Acceleration Spectral Density). Random vibration testing method may be used instead of the sinusoidal vibration test. The test severity
values are not specified in IEC 60068-2-64 [12]. The maximum test frequency has been reduced because between 100 Hz and 200 Hz the contribution is
insignificant.
classes: 1.1 and 1.2 class: 1.3
2 2
Acceleration RMS
1,06 m/s 1,5 m/s
(for information only)

NOTE 3: (Shocks) No test is required because this condition is covered by transportation test for packaged equipment and by in-use test for unpackaged equipment.
NOTE 4: (Load) Packaging and/or equipment should be designed taking into account this requirement but no tests are required.

ETSI

---------------------- Page: 10 ----------------------
11 ETSI EN 300 019-2-1 V2.3.1 (2017-11)
4.4 Specification T 1.2: Weatherprotected, not temperature-controlled storage locations
The specifications in tables 3 and 4 shall apply to weatherprotected or partially weatherprotected storage locations having neither temperature nor humidity control described in
ETSI EN 300 019-1-1 [1].
Table 3: Test specification T 1.2: Weatherprotected, not temperature-controlled storage locations - climatic tests
Environmental parameter Environmental Environmental test specification T1.2: Weatherprotected,
Class 1.2 not temperature-controlled storage locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
severity criterion
low (°C) -25 -25 72 h IEC 60068-2-1 [4] Ab: Cold A
Air high (°C) +55 +55 or +70 72 h IEC 60068-2-2 [5] Bb: Dry heat A 1
temperature change (°C/min) 0,5 None   2
 low (%) 10 None   8
 high (%) 100 93 96 h
...

Draft ETSI EN 300 019-2-1 V2.2.8 (2017-08)






EUROPEAN STANDARD
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 2-1: Specification of environmental tests;
Storage

---------------------- Page: 1 ----------------------
2 Draft ETSI EN 300 019-2-1 V2.2.8 (2017-08)



Reference
REN/EE-0170
Keywords
environment, equipment practice, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88

Important notice
The present document can be downloaded from:
http://www.etsi.org/standards-search
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the
print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
https://portal.etsi.org/TB/ETSIDeliverableStatus.aspx
If you find errors in the present document, please send your comment to one of the following services:
https://portal.etsi.org/People/CommiteeSupportStaff.aspx
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying
and microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.

© ETSI 2017.
All rights reserved.

TM TM TM
DECT , PLUGTESTS , UMTS and the ETSI logo are trademarks of ETSI registered for the benefit of its Members.
TM
3GPP and LTE™ are trademarks of ETSI registered for the benefit of its Members and
of the 3GPP Organizational Partners.
oneM2M logo is protected for the benefit of its Members.
GSM® and the GSM logo are trademarks registered and owned by the GSM Association.
ETSI

---------------------- Page: 2 ----------------------
3 Draft ETSI EN 300 019-2-1 V2.2.8 (2017-08)
Contents
Intellectual Property Rights . 4
Foreword . 4
Modal verbs terminology . 5
1 Scope . 6
2 References . 6
2.1 Normative references . 6
2.2 Informative references . 6
3 Definitions . 7
4 Environmental test specifications . 7
4.0 General . 7
4.1 Equipment setup and configuration . 7
4.2 Performance criteria . 7
4.3 Specification T 1.1: Weatherprotected, partly temperature-controlled storage locations . 8
4.4 Specification T 1.2: Weatherprotected, not temperature-controlled storage locations . 11
4.5 Specification T 1.3: Non-weatherprotected storage locations and T 1.3 E: Non-weatherprotected storage
locations - extended . 14
Annex A (informative): Bibliography . 21
History . 22

ETSI

---------------------- Page: 3 ----------------------
4 Draft ETSI EN 300 019-2-1 V2.2.8 (2017-08)
Intellectual Property Rights
Essential patents
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (https://ipr.etsi.org/).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Trademarks
The present document may include trademarks and/or tradenames which are asserted and/or registered by their owners.
ETSI claims no ownership of these except for any which are indicated as being the property of ETSI, and conveys no
right to use or reproduce any trademark and/or tradename. Mention of those trademarks in the present document does
not constitute an endorsement by ETSI of products, services or organizations associated with those trademarks.
Foreword
This draft European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE),
and is now submitted for the combined Public Enquiry and Vote phase of the ETSI standards EN Approval Procedure.
The present document is part 2, sub-part 1 of a multi-part deliverable covering the environmental conditions and
environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions";
Part 2: "Specification of environmental tests":
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations".
Part 1 specifies different standardized environmental classes covering climatic and biological conditions, chemically
and mechanically active substances and mechanical conditions during storage, transportation and in use.
Part 2 specifies the recommended test severities and test methods for the different environmental classes.
ETSI

---------------------- Page: 4 ----------------------
5 Draft ETSI EN 300 019-2-1 V2.2.8 (2017-08)
Proposed national transposition dates
Date of latest announcement of this EN (doa): 3 months after ETSI publication
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 6 months after doa
Date of withdrawal of any conflicting National Standard (dow): 6 months after doa

Modal verbs terminology
In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and
"cannot" are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of
provisions).
"must" and "must not" are NOT allowed in ETSI deliverables except when used in direct citation.
ETSI

---------------------- Page: 5 ----------------------
6 Draft ETSI EN 300 019-2-1 V2.2.8 (2017-08)
1 Scope
The present document specifies test severities and methods for verification of the required resistibility of equipment
according to the relevant environmental class.
The tests defined in the present document apply to storage of equipment covering the environmental conditions stated in
ETSI EN 300 019-1-1 [1].
2 References
2.1 Normative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
https://docbox.etsi.org/Reference/.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
The following referenced documents are necessary for the application of the present document.
[1] ETSI EN 300 019-1-1 (2014): "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-1: Classification of environmental
conditions; Storage".
[2] Void.
[3] Void.
[4] IEC 60068-2-1:2007: "Environmental testing - Part 2-1: Tests - Test A: Cold".
[5] IEC 60068-2-2:2007: "Environmental testing - Part 2-2: Tests - Test B: Dry heat".
[6] IEC 60068-2-6:2007: "Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)".
[7] IEC 60068-2-14:2009: "Environmental testing - Part 2-14: Tests - Test N: Change of temperature".
[8] IEC 60068-2-18:2017: "Environmental testing - Part 2-18: Tests - Test R and guidance: Water".
[9] IEC 60068-2-27:2008: "Environmental testing. Part 2-27: Tests - Test Ea and guidance: Shock".
[10] IEC 60068-2-30:2005: "Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic
(12 + 12 hour cycle)".
[11] IEC 60068-2-78:2012: "Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady
state".
[12] IEC 60068-2-64:2008: "Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband
random and guidance".
2.2 Informative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
ETSI

---------------------- Page: 6 ----------------------
7 Draft ETSI EN 300 019-2-1 V2.2.8 (2017-08)
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
The following referenced documents are not necessary for the application of the present document but they assist the
user with regard to a particular subject area.
[i.1] ETSI EN 300 019-2-0 (2003): "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 2-0: Specification of environmental
tests; Introduction".
[i.2] IEC 60068-2-68:1994: "Environmental testing - Part 2-68: Tests - Test L: Dust and sand".
[i.3] ETSI EN 300 019-1-0: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-0: Classification of environmental
conditions; Introduction".
3 Definitions
For the purposes of the present document, the terms and definitions given in ETSI EN 300 019-1-0 [i.3] apply.
4 Environmental test specifications
4.0 General
The equipment shall be tested in the state in which it is normally stored where this is possible. For example, if the
detailed descriptions of the environmental conditions are given in clauses 4 and 5 of ETSI EN 300 019-1-1 [1].
ETSI EN 300 019-2-0 [i.1] forms a general overview of part 2 of this multi-part deliverable.
If the equipment is normally stored in a packed state then it shall be tested in its packaging.
4.1 Equipment setup and configuration
The equipment shall be tested in the state in which it is normally stored where this is possible. For example, if the
equipment is stored in a packed state, then it shall be tested in its packaging. If the equipment can be stored both with
and without its packaging it is necessary to perform tests for both configurations. For some tests and equipment, the test
may be more severe for the packaged rather than the unpacked equipment. For example, for an equipment in a sealed
package, the change of temperature test may produce condensation.
4.2 Performance criteria
The following performance criterion A shall apply in the tests defined by the present document.
Performance criterion A:
The equipment, or piece of equipment, shall be verified before and after the tests, The equipment shall function
according to the manufacturer specifications before and after the test. No electrical or mechanical damages shall be
allowed due to the application of the tests.
ETSI

---------------------- Page: 7 ----------------------
8 Draft ETSI EN 300 019-2-1 V2.2.8 (2017-08)
4.3 Specification T 1.1: Weatherprotected, partly temperature-controlled storage locations
The specifications in tables 1 and 2 shall apply to weatherprotected or partially weather-controlled storage locations having partially temperature or humidity control described
in ETSI EN 300 019-1-1 [1].
Table 1: Test specification T 1.1: Weatherprotected, partly temperature-controlled storage locations - climatic tests
Environmental parameter Environmental Environmental test specification T1.1: Weatherprotected,
Class 1.1 partly temperature-controlled storage locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
Severity criteria
low (°C) -5 -5 72 h IEC 60068-2-1 [4] Ab: Cold A
Air high (°C) +45 +45 or +55 72 h IEC 60068-2-2 [5] Bb: Dry heat A 1
temperature
change (°C/min) 0,5 None   2
 low (%) 5 None   7
relative high (%) 95 93 96 h IEC 60068-2-78 [11] Cab: Damp heat A 3
steady state
(°C) +30
Humidity condensation Yes None   4
3

absolute 1 None   7
low (g/m )
3
 29   5
high (g/m )
pressure low (kPa) 70 None   6
Air high (kPa) 106 None   6
speed (m/s) 1 None   7
rain intensity no
Water low temperature no
other sources no
icing & frosting yes None   7
2
Radiation solar 700 None   8
(W/m )
2
heat 600 None   8
(W/m )
ETSI

---------------------- Page: 8 ----------------------
9 Draft ETSI EN 300 019-2-1 V2.2.8 (2017-08)
Environmental parameter Environmental Environmental test specification T1.1: Weatherprotected,
Class 1.1 partly temperature-controlled storage locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
Severity criteria
3
sulphur 0,3/1,0 None   9

SO (mg/m )
2
3
 0,1/0,5 None   9
HS (mg/m )
2
 Salts sea and road salt mist None   9
3
Chemically chlorine 0,1/0,3 None   9
Cl (mg/m )
2
3
active 0,1/0,5 None   9
HCI (mg/m )
3
substances nitrogen 0,5/1,0 None   9
NO (mg/m )
x
3
 1,0/3,0 None   9
NH (mg/m )
3
3
hydrogen fluoride 0,01/0,03 None   9
HF (mg/m )
3
ozone 0,05/0,1 None   9
O (mg/m )
3
Mechanically dust Sedimentation 1,5 None   10
2
(mg/(m h))
3
active 0,2 None   10
suspension (mg/m )
3
substances sand 30 None   10
(mg/m )
Flora and micro organisms negligible
Fauna rodents, insects negligible
Legenda: no = this condition does not occur in this class.
NOTE 1: (Air temperature, high) Two test temperatures are given. The lower temperature shall apply if the equipment is protected against solar radiation.
NOTE 2: The characteristic severity value is considered to have insignificant effect on the equipment and therefore no test is required.
NOTE 3: (Humidity, relative high) These severities are the nearest IEC test temperature values, which according to the climatogram can be achieved in the relative
humidity given in the table. This test is recommended for unpacked equipment only.
NOTE 4: This characteristic severity corresponds to the high value of relative humidity and small temperature variation within the equipment and is considered to be
covered by test IEC 60068-2-78 [11] Test Cab. Therefore, no additional tests are required.
NOTE 5: This effect is considered to be partly included in test IEC 60068-2-78 [11] Test Cab and/or test IEC 60068-2-30 [10] Test Db. Therefore, no additional tests
are required.
NOTE 6: (Air pressure, low and high) No test is required at equipment level or on sub-assemblies of it, because the effect of air pressure is evaluated at the
component level.
NOTE 7: The characteristic severity value is considered to have insignificant effect on the equipment in storage conditions and furthermore there is no IEC test method
for this parameter, therefore no test is required.
NOTE 8: (Radiation, solar, heat)The heating effect of solar radiation is included in the higher test temperature in IEC 60068-2-2 [5] Test Bb as described in note 2.
Photochemical tests can be made separately for components and materials. No test is required in the present document.
NOTE 9: (Chemically active substances) Characteristic severities are mean/maximum values. The characteristic severities should be considered when choosing
components and materials. No test is required in the present document.
NOTE 10: (Mechanically active substances) For mechanically active substances the packaging is supposed to protect the equipment against dust and sand where
needed, therefore no test is required. Furthermore, the levels of dust, both sedimentation and suspension, are far lower than the lowest severity
recommended in IEC 60068-2-68 [i.2] Test Lb.

ETSI

---------------------- Page: 9 ----------------------
10 Draft ETSI EN 300 019-2-1 V2.2.8 (2017-08)
Table 2: Test specification T 1.1: Weatherprotected, partly temperature-controlled storage locations - mechanical tests
Environmental parameter Environmental Environmental test specification T 1.1: Weatherprotected,
Class 1.1 partly temperature-controlled storage locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
severity criteria
Fc: Vibration
 velocity (mm/s) 5 IEC 60068-2-6 [6] A 1
(sinusoidal)
 displacement (mm) 1,5
2
sinusoidal 5 2
acceleration (m/s )
2 - 9 9 - 200 5 - 62 62 - 200 3 x 5
frequency range (Hz)
sweep
Vibration 3
axes of vibration
cycles
2 3 IEC 60068-2-64 [12] Fh: Vibration,
  0,02 A 2
ASD (m /s )
broad-band
random +12 -12 3 x 30
(dB/oct)
random
minutes
5 - 10; 10 - 50; 50 - 100
frequency range (Hz)
(digital control)
3
axes of vibration
Shocks shocks shock spectrum Type L None   3
duration (ms) 22
2
40
acceleration (m/s )
number of shocks
directions of shocks
Load static load (kPa) 5 None   4
Legenda: no = this condition does not occur in this class.
NOTE 1: (Vibration, sinusoidal) The characteristic severities are given as peak values. The test severity values defined for this phenomenon are not specified in
IEC 60068-2-6 [6].
NOTE 2: (Vibration, random) ASD (Acceleration Spectral Density). Random vibration testing method may be used instead of the sinusoidal vibration test. The test severity
values are not specified in IEC 60068-2-64 [12]. The maximum test frequency has been reduced because between 100 Hz and 200 Hz the contribution is
insignificant.
classes: 1.1 and 1.2 class: 1.3
2 2
Acceleration RMS
1,06 m/s 1,5 m/s
(for information only)

NOTE 3: (Shocks) No test is required because this condition is covered by transportation test for packaged equipment and by in-use test for unpackaged equipment.
NOTE 4: (Load) Packaging and/or equipment should be designed taking into account this requirement but no tests are required.

ETSI

---------------------- Page: 10 ----------------------
11 Draft ETSI EN 300 019-2-1 V2.2.8 (2017-08)
4.4 Specification T 1.2: Weatherprotected, not temperature-controlled storage locations
The specifications in tables 3 and 4 shall apply to weatherprotected or partially weatherprotected storage locations having neither temperature nor humidity control described in
ETSI EN 300 019-1-1 [1].
Table 3: Test specification T 1.2: Weatherprotected, not temperature-controlled storage locations - climatic tests
Environmental parameter Environmental Environmental test specification T1.2: Weatherprotected,
Class 1.2 not temperature-controlled storage locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
severity criterion
low (°C) -25 -25 72 h IEC 60068-2-1 [4] Ab: Cold A
Air high (°C) +55 +55 or +70 72 h IEC 60068-2-2 [5] Bb: Dry heat A 1
temperature change (°C/min) 0,5
...

Questions, Comments and Discussion