Secure storage units - Classification and methods of test for resistance to fire - Light fire storage units

This European Standard specifies requirements for light fire storage units providing protection against fire. The method of test is specified to determine the ability of light fire storage units to protect paper media from the effects of fire. Two levels of fire exposure periods (LFS 30 P and LFS 60 P) are specified using the maximum temperature increase permitted within the storage space of the light fire storage unit. Requirements are also specified for the test specimen, the technical documentation for the test specimen, correlation of the test specimen with the technical documentation, preparation for type testing and test procedures. A scheme to classify the light fire storage units from the test results is also given (see Table 1).

Wertbehältnisse - Klassifizierung und Methoden zur Prüfung des Widerstandes gegen Brand - Leichte Brandschutzschränke

Diese Europäische Norm legt Anforderungen an leichte Brandschutzschränke zum Schutz gegen Brände fest.
Das Prüfverfahren dient der Ermittlung der Widerstandsfähigkeit von leichten Brandschutzschränken, um Papierdokumente vor Brandeinwirkung zu schützen. Zwei Stufen der Beflammungsdauer  (LFS 30 P und LFS 60 P) sind vorgesehen, die unter Berücksichtigung der im Innenraum des Brandschutzschrankes maximal zulässi¬gen Temperaturerhöhung definiert werden.
Außerdem sind Anforderungen für den Probekörper, die Technische Dokumentation des Probekörpers, die Überein¬stimmung von Probekörper mit der Technischen Dokumentation, die Vorbereitung der Typprüfung sowie das Prüfverfahren definiert.
Ferner wird ein Schema zur Klassifizierung von leichten Brandschutzschränken nach ihrem Prüfergebnis gegeben (siehe Tabelle 1).

Unités de stockage en lieu sur - Classification et méthodes d'essaisde résistance au feu - Meubles ignifuges premier niveau

La présente Norme européenne spécifie les exigences relatives aux meubles ignifuges premier niveau
procurant une protection contre l’incendie.
Cette méthode d’essai vise à déterminer la capacité des meubles ignifuges premier niveau à protéger le
média papier contre les effets du feu. Deux niveaux de durée d’exposition au feu (MIPN 30 P et MIPN 60 P)
sont spécifiées, compte tenu de l’augmentation maximale de température admise dans l’espace de stockage
du meuble ignifuge premier niveau.
Les exigences s’appliquent également à l’éprouvette, à la documentation technique concernant l’éprouvette, à
la corrélation entre l’éprouvette et la documentation technique, à la préparation de l’essai de type et aux
modes opératoires d’essai.
Une classification des meubles ignifuges premier niveau en fonction des résultats d’essai est également
fournie (voir Tableau 1).

Varnostne shranjevalne enote - Klasifikacija in metode preskušanja odpornosti proti ognju - Shranjevalne enote za zaščito papirja do 170 °C

General Information

Status
Withdrawn
Public Enquiry End Date
29-Sep-2007
Publication Date
16-Aug-2009
Withdrawal Date
12-Nov-2019
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
13-Nov-2019
Due Date
06-Dec-2019
Completion Date
13-Nov-2019

Relations

Buy Standard

Standard
EN 15659:2009
English language
13 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Wertbehältnisse - Klassifizierung und Methoden zur Prüfung des Widerstandes gegen Brand - Leichte BrandschutzschränkeUnités de stockage en lieu sur - Classification et méthodes d'essaisde résistance au feu - Meubles ignifuges premier niveauSecure storage units - Classification and methods of test for resistance to fire - Light fire storage units35.220.99Druge naprave za shranjevanje podatkovOther data storage devices13.310Varstvo pred kriminalomProtection against crime13.220.40Sposobnost vžiga in obnašanje materialov in proizvodov pri gorenjuIgnitability and burning behaviour of materials and productsICS:Ta slovenski standard je istoveten z:EN 15659:2009SIST EN 15659:2009en,fr01-oktober-2009SIST EN 15659:2009SLOVENSKI
STANDARD



SIST EN 15659:2009



EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 15659April 2009ICS 13.220.40; 91.060.01 English VersionSecure storage units - Classification and methods of test forresistance to fire - Light fire storage unitsUnités de stockage en lieu sûr - Classification et méthodesd'essaisde résistance au feu - Meubles ignifuges premierniveauWertbehältnisse - Klassifizierung und Methoden zurPrüfung des Widerstandes gegen Brand - LeichteBrandschutzschränkeThis European Standard was approved by CEN on 19 March 2009.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre:
Avenue Marnix 17,
B-1000 Brussels© 2009 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15659:2009: ESIST EN 15659:2009



EN 15659:2009 (E) 2 Contents Page Foreword . 3 Introduction . 4 1 Scope . 5 2 Normative references . 5 3 Terms and definitions . 5 4 Requirements, classification and locks . 5 5 Test specimen, technical documentation and correlation . 6 5.1 Test specimen . 6 5.2 Technical documentation of the test specimen . 6 5.3 Correlation of test specimens and technical documentation . 7 6 Test methods . 7 6.1 Principle . 7 6.2 Test equipment . 7 6.3 Preparation for test . 8 6.4 Procedure . 10 6.4.1 Correlation . 10 6.4.2 Fire endurance test . 11 6.4.3 Examination . 12 7 Test report . 12 8 Marking . 12
Figures Figure 1 — Measurement points . 9 Figure 2 — Cable entry hole and sealing . 10 Figure 3 — Protection of instrument cables . 11
Tables Table 1 — Protection level requirements . 6
SIST EN 15659:2009



EN 15659:2009 (E) 3 Foreword This document (EN 15659:2009) has been prepared by Technical Committee CEN/TC 263 “Secure storage of cash, valuables and data media”, the secretariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2009, and conflicting national standards shall be withdrawn at the latest by October 2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. SIST EN 15659:2009



EN 15659:2009 (E) 4 Introduction The testing conditions given in this European Standard provide a basis for simulating fires to determine, in a reproducible way, the fire resistance of light fire storage units at various protection levels. The protection levels enable a comparison to be made of the resistance against fire provided by different constructions. The threshold value for the maximum temperature increase of 150 K at every measuring point in the protection levels LFS 30 P and LFS 60 P for light fire storage units from a starting temperature of (21 ± 1)°C, as defined in this European Standard, refers to the relatively short-term stress due to high temperatures during a fire test. It is not normally experienced by paper media stored in light fire storage units in the normal and correct way. SIST EN 15659:2009



EN 15659:2009 (E) 5 1 Scope This European Standard specifies requirements for light fire storage units providing protection against fire.
The method of test is specified to determine the ability of light fire storage units to protect paper media from the effects of fire. Two levels of fire exposure periods (LFS 30 P and LFS 60 P) are specified using the maximum temperature increase permitted within the storage space of the light fire storage unit. Requirements are also specified for the test specimen, the technical documentation for the test specimen, correlation of the test specimen with the technical documentation, preparation for type testing and test procedures. A scheme to classify the light fire storage units from the test results is also given (see Table 1). 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1363-1:1999, Fire resistance tests — Part 1: General requirements EN 60584-1, Thermocouples — Part 1: Reference tables (IEC 60584-1:1995). 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 light fire storage unit storage unit designed to protect paper media, except for paper grades where data loss occurs at temperatures below 172°C, as well as valuables against the effects of temperatures up to 172°C NOTE A light fire storage unit can have doors, drawers, lids, connections and fittings. 3.2 compartment part of a light fire storage unit which can be closed with a separate door, lid or cover NOTE A compartment formed by inserting a shelf board is not a compartment within the meaning of this standard. 3.3 lock device which verifies an entered code and performs a blocking function on the boltwork or the door 4 Requirements, classification and locks 4.1 Light fire storage units shall provide protection against the effects of fire (see Clause 6) and be classified as specified in Table 1. SIST EN 15659:2009



EN 15659:2009 (E) 6 Table 1 — Protection level requirements Protection level Maximum temperature increase 30 min 60 min LFS 30 P LFS 60 P 150 K NOTE 1
Where LFS is the symbol applied for light fire storage units. NOTE 2
The numerical values in the protection level are the duration of fire exposure during the type test in minutes.
NOTE 3
P represents protection of data on paper, excluding those paper grades which lose data below 172ºC.
4.2 Light fire storage units shall be fitted with a lock. 5 Test specimen, technical documentation and correlation 5.1 Test specimen Of several models of a series (with one door, two doors, drawers, etc.) having the same design, protection and construction features (type and thickness of construction and protective materials, rabbet geometry, etc.) as well as the same base (with a tolerance of ± 15 % each applicable to the internal dimensions of width and depth), the models with the smallest and largest internal height resp. the lowest and highest number of drawers shall be tested.
Light fire storage units with double doors shall be regarded as a separate model range. Where a variety of locking options is available, the test specimen used in the type test shall be coordinated with the testing laboratory. Two identical light fire storage units shall be available: one for the fire endurance test, the other for verifying correlation of the filling material with the technical documentation. The testing laboratory shall decide which test sp
...