Chemicals used for the treatment of swimming pool water - Iron based coagulants

This European Standard is applicable to iron based coagulants (iron (III) chloride, iron (III) chloride sulfate and iron (III) sulfate liquid) used directly or for the production of formulations for treatment of water for swimming pools. It describes the characteristics of iron based coagulants and specifies the requirements and the corresponding test methods for iron based coagulants. It gives information on their use in swimming pool water treatment. General information on iron based coagulants is given in Annex A. It also determines the rules relating to safe handling and use (see Annex B).

Produkte zur Aufbereitung von Schwimm-und Badebackenwasser - Flockungsmittel auf Eisenbasis

Dieses Dokument gilt für Flockungsmittel auf Eisenbasis (Eisen(III)-chlorid, Eisen(III)-chloridsulfat und
Eisen(III)-sulfat, flüssig), die direkt zur Aufbereitung von Schwimm- und Badebeckenwasser oder zur
Herstellung von Zubereitungen für diesen Zweck verwendet werden.
Es beschreibt die Eigenschaften von Flockungsmitteln auf Eisenbasis und legt die Anforderungen sowie die
entsprechenden Prüfverfahren für Flockungsmittel auf Eisenbasis fest. Es enthält Angaben zu deren Anwendung
in der Aufbereitung von Schwimm- und Badebeckenwasser. Allgemeine Angaben zu Flockungsmitteln
auf Eisenbasis sind in Anhang A enthalten.
Es legt darüber hinaus Regeln für die sichere Handhabung und Verwendung fest (siehe Anhang B).

Produits chimiques utilisés pour le traitement de l'eau des piscines - Coagulants à base de fer

Le présent document est applicables aux coagulants à base de fer (chlorure de fer (III), chlorosulfate de fer (III) et sulfate de fer (III) liquide) utilisés directement ou pour la production de formulations pour le traitement de l’eau des piscines.
Elle décrit les caractéristiques des coagulants à base de fer et spécifie les prescriptions et les méthodes d’essai correspondantes. Elle donne des informations pour leur utilisation dans le traitement de l’eau des piscines. Elle fixe également les règles relatives à la sécurité d’emploi et de manipulation (voir Annexe B).

Kemikalije, ki se uporabljajo za pripravo bazenske vode - Strjevanje na osnovi železa

Ta evropski standard se uporablja za sredstva za strjevanje na osnovi železa (železov (III) klorid, železov (III) klorid sulfat in železov (III) sulfat v tekočem stanju), ki se uporabljajo neposredno ali za proizvodnjo pripravkov za pripravo bazenske vode. Opisuje značilnosti sredstev za strjevanje na osnovi železa ter opredeljuje zahteve in ustrezne metode preskušanja za sredstva za strjevanje na osnovi železa. Podaja podatke o njihovi uporabi pri pripravi bazenske vode. Splošni podatki o sredstvih za strjevanje na osnovi železa so podani v Dodatku A. Prav tako opredeljuje pravila, ki se nanašajo na rokovanje in uporabo (glej Dodatek B).

General Information

Status
Withdrawn
Publication Date
09-Feb-2010
Withdrawal Date
08-Jun-2022
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
09-Jun-2022
Due Date
02-Jul-2022
Completion Date
09-Jun-2022

Relations

Buy Standard

Standard
EN 15797:2010
English language
12 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Kemikalije, ki se uporabljajo za pripravo bazenske vode - Strjevanje na osnovi železaProdukte zur Aufbereitung von Schwimm-und Badebackenwasser - Flockungsmittel auf EisenbasisProduits chimiques utilisés pour le traitement de l'eau des piscines - Coagulants à base de ferChemicals used for the treatment of swimming pool water - Iron based coagulants71.100.80Chemicals for purification of water13.060.25Voda za industrijsko uporaboWater for industrial useICS:Ta slovenski standard je istoveten z:EN 15797:2010SIST EN 15797:2010en,fr,de01-marec-2010SIST EN 15797:2010SLOVENSKI
STANDARD



SIST EN 15797:2010



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 15797
January 2010 ICS 71.100.80 English Version
Chemicals used for the treatment of swimming pool water - Iron based coagulants
Produits chimiques utilisés pour le traitement de l'eau des piscines - Coagulants à base de fer
Produkte zur Aufbereitung von Schwimm- und Badebackenwasser - Flockungsmittel auf Eisenbasis This European Standard was approved by CEN on 28 November 2009.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2010 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15797:2010: ESIST EN 15797:2010



EN 15797:2010 (E) 2 Contents Page Foreword .3Introduction .41Scope .52Normative references .53Description .54Purity criteria .54.1General .54.2Composition of commercial product .54.3Impurities and main by-products .64.4Chemical parameters .65Test methods .66Labelling - Transportation - Storage .66.1Means of delivery .66.2Risk and safety labelling in accordance with the EU Directives .66.3Transportation regulations and labelling .76.4Marking .86.5Storage .9Annex A (informative)
General information on iron based coagulants . 10A.1Origin . 10A.2Use . 10Annex B (normative)
General rules relating to safety . 11B.1Rules for safe handling and use . 11B.2Emergency procedures . 11Bibliography . 12 SIST EN 15797:2010



EN 15797:2010 (E) 3 Foreword This document (EN 15797:2010) has been prepared by Technical Committee CEN/TC 164 “Water supply”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by July 2010, and conflicting national standards shall be withdrawn at the latest by July 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. SIST EN 15797:2010



EN 15797:2010 (E) 4 Introduction In respect of potential adverse effects on the quality of water for swimming pools, caused by the products covered by this European Standard: a) this document provides no information as to whether the products may be used without restriction in any of the Member States of the EU or EFTA; b) it should be noted that, while awaiting the adoption of verifiable European criteria, existing national regulations concerning the use and/or the characteristics of these products remain in force. NOTE Conformity with the document does not confer or imply acceptance or approval of the products in any of the Member States of the EU or EFTA. The use of these products covered by this document is subject to regulation or control by National Authorities. SIST EN 15797:2010



EN 15797:2010 (E) 5
1 Scope This European Standard is applicable to iron based coagulants (iron (III) chloride, iron (III) chloride sulfate and iron (III) sulfate liquid) used directly or for the production of formulations for treatment of water for swimming pools. It describes the characteristics of iron based coagulants and specifies the requirements and the corresponding test methods for iron based coagulants. It gives information on their use in swimming pool water treatment. General information on iron based coagulants is given in Annex A. It also determines the rules relating to safe handling and use (see Annex B). 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 888, Chemicals used for treatment of water intended for human consumption
Iron (III) chloride EN 890, Chemicals used for treatment of water intended for human consumption
Iron (III) sulfate liquid EN 891, Chemicals used for treatment of water intended for human consumption
Iron (III) chloride sulfate 3 Description For the identification, the commercial form, the physical properties and the chemical properties see the relevant subclauses of EN 888, EN 890 and EN 891. 4 Purity criteria 4.1
General This document specifies the minimum purity requirements for iron based coagulants used for the treatment of water for swimming pools. Limits are given for impurities commonly present in the products. Depending on the raw material and the manufacturing process other impurities may be present and, if so, this shall be notified to the user and when necessary to relevant authorities. NOTE Users of these products should check the national regulations in order to clarify whether they are of appropriate purity for treatment of water for swimming pools, taking into account water quality, required dosage, contents of other impurities and additives used in these products not stated in these product standards. Limits have been given for impurities and chemical parameters where these are likely to be present in significant quantities from the current prod
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.