SIST ETS 300 446 E1:2003
(Main)Radio Equipment and Systems (RES); ElectroMagnetic Compatibility (EMC) standard for second generation Cordless Telephone (CT2) apparatus operating in the frequency band 864,1 MHz to 868,1 MHz, including public access services
Radio Equipment and Systems (RES); ElectroMagnetic Compatibility (EMC) standard for second generation Cordless Telephone (CT2) apparatus operating in the frequency band 864,1 MHz to 868,1 MHz, including public access services
Covers the EMC standard for cordless telephones CT2. The ETS may be used to demonstrate compliance with the requirements of the EMC Directive 89/336/EEC.
Radijska oprema in sistemi (RES) – Standard elektromagnetne združljivosti (EMC) brezvrvičnih telefonskih naprav druge generacije (CT2), ki delujejo v frekvenčnem pasu od 864,1 MHz do 868,1 MHz, vključno s storitvami javnega dostopa
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST ETS 300 446 E1:2003
01-december-2003
5DGLMVNDRSUHPDLQVLVWHPL5(6±6WDQGDUGHOHNWURPDJQHWQH]GUXåOMLYRVWL(0&
EUH]YUYLþQLKWHOHIRQVNLKQDSUDYGUXJHJHQHUDFLMH&7NLGHOXMHMRYIUHNYHQþQHP
SDVXRG0+]GR0+]YNOMXþQRVVWRULWYDPLMDYQHJDGRVWRSD
Radio Equipment and Systems (RES); ElectroMagnetic Compatibility (EMC) standard for
second generation Cordless Telephone (CT2) apparatus operating in the frequency band
864,1 MHz to 868,1 MHz, including public access services
Ta slovenski standard je istoveten z: ETS 300 446 Edition 1
ICS:
33.060.20 Sprejemna in oddajna Receiving and transmitting
oprema equipment
33.100.01 Elektromagnetna združljivost Electromagnetic compatibility
na splošno in general
SIST ETS 300 446 E1:2003 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST ETS 300 446 E1:2003
---------------------- Page: 2 ----------------------
SIST ETS 300 446 E1:2003
EUROPEAN ETS 300 446
TELECOMMUNICATION June 1996
STANDARD
Source: ETSI TC-RES Reference: DE/RES-09012
ICS: 33.100, 33.060.20, 33.060.50
CT2, EMC, radio
Key words:
Radio Equipment and Systems (RES);
Electro-Magnetic Compatibility (EMC) standard
for second generation Cordless Telephone (CT2) apparatus
operating in the frequency band 864,1 MHz to 868,1 MHz,
including public access services
ETSI
European Telecommunications Standards Institute
ETSI Secretariat
F-06921 Sophia Antipolis CEDEX - FRANCE
Postal address:
650 Route des Lucioles - Sophia Antipolis - Valbonne - FRANCE
Office address:
c=fr, a=atlas, p=etsi, s=secretariat - secretariat@etsi.fr
X.400: Internet:
Tel.: +33 92 94 42 00 - Fax: +33 93 65 47 16
*
Copyright Notification: No part may be reproduced except as authorized by written permission. The copyright and the
foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 1996. All rights reserved.
---------------------- Page: 3 ----------------------
SIST ETS 300 446 E1:2003
Page 2
ETS 300 446: June 1996
Whilst every care has been taken in the preparation and publication of this document, errors in content,
typographical or otherwise, may occur. If you have comments concerning its accuracy, please write to
"ETSI Editing and Committee Support Dept." at the address shown on the title page.
---------------------- Page: 4 ----------------------
SIST ETS 300 446 E1:2003
Page 3
ETS 300 446: June 1996
Contents
Foreword .5
1 Scope .7
2 Normative references.7
3 Definitions and abbreviations .8
3.1 Definitions .8
3.2 Abbreviations .9
4 General test conditions.9
4.1 Test conditions.9
4.2 Arrangements for test signals at the input of the transceiver .9
4.2.1 Speech equipment .9
4.3 Normal test modulation.10
4.4 Connection of test signals for transceivers.10
4.4.1 Radio Frequency (RF) connection .10
4.5 Connection of test signals for receiver-only equipment .10
4.5.1 RF connection .10
4.6 Receiver test signal level .10
4.7 Narrow band responses on receivers or receivers which are part of transceivers .10
4.8 Exclusion bands.11
4.8.1 Exclusion band for CT2 receivers and CT2 receiver parts of transceivers.11
4.8.2 Exclusion band for CT2 transmitter parts of transceivers .11
5 Performance assessment .11
5.1 General .11
5.2 Equipment classification .12
5.3 Ancillary equipment.12
5.4 Assessment of host connected equipment and plug-in cards .12
5.4.1 Alternative A: composite equipment.12
5.4.2 Alternative B: use of a test jig and three hosts.12
5.5 Performance assessment test procedure to verify no loss of user control functions or
stored data for CT2 transceivers .13
5.6 Performance assessment of audio breakthrough.13
6 Performance criteria.14
6.1 Performance criteria for Continuous phenomena applied to CT2 Transceivers (CT) .15
6.2 Performance criteria for Transient phenomena applied to CT2 Transceivers (TT).15
6.3 Performance criteria for Continuous phenomena applied to CT2 Receive-only
equipment (CR) .15
6.4 Performance criteria for Transient phenomena applied to CT2 Receive-only equipment
(TR).15
7 Applicability overview tables.15
7.1 Emission .16
7.2 Immunity .16
8 Test methods and limits for emission tests of transceivers and/or receivers and/or ancillary
equipment.17
8.1 Test configuration .17
8.2 Enclosure.17
8.2.1 Definition .17
8.2.2 Test method .17
8.2.3 Test limit.17
8.3 DC power input/output port.18
---------------------- Page: 5 ----------------------
SIST ETS 300 446 E1:2003
Page 4
ETS 300 446: June 1996
8.3.1 Definition. 18
8.3.2 Test method. 18
8.3.3 Test limit . 18
8.4 AC mains power input/output port. 18
8.4.1 Definition. 18
8.4.2 Test method. 19
8.4.3 Test limit . 19
9 Test methods and levels for immunity tests of transceivers and/or receivers and/or ancillary
equipment. 19
9.1 Test configuration. 19
9.2 Radio frequency electro-magnetic field (80 to 1 000 MHz) . 20
9.2.1 Enclosure. 20
9.2.1.1 Definition . 20
9.2.1.2 Test method and level. 20
9.2.1.3 Performance criteria. 20
9.3 Electrostatic discharge . 20
9.3.1 Definition. 20
9.3.2 Test method and levels. 20
9.3.3 Performance criteria . 21
9.4 Fast transients common mode. 21
9.4.1 Definition. 21
9.4.2 Test method and levels. 21
9.4.3 Performance criteria . 21
9.5 RF common mode, 0,15 MHz to 80 MHz (current clamp injection) . 22
9.5.1 Definition. 22
9.5.2 Test method and level . 22
9.5.3 Performance criteria . 22
9.6 Transients and surges, vehicular environment . 23
9.6.1 Definition. 23
9.6.2 Test method and level . 23
9.6.3 Performance criteria . 24
9.7 Voltage dips and interruptions. 24
9.7.1 Definition. 24
9.7.2 Test method and levels. 24
9.7.3 Performance criteria . 24
9.8 Surges, common and differential mode . 25
9.8.1 Definition. 25
9.8.2 Test method and levels. 25
9.8.3 Performance criteria . 26
History. 27
---------------------- Page: 6 ----------------------
SIST ETS 300 446 E1:2003
Page 5
ETS 300 446: June 1996
Foreword
This European Telecommunication Standard (ETS) has been prepared by the Radio Equipment and
Systems (RES) Technical Committee of the European Telecommunications Standards Institute (ETSI).
Other standards cover radio communications equipment not listed in the scope.
This ETS is based upon the Generic Standards EN 50081-1 [1] and EN 50082-1 [2], and other standards,
where appropriate.
Transposition dates
Date of adoption of this ETS: 30 June 1996
Date of latest announcement of this ETS (doa): 30 September 1996
Date of latest publication of new National Standard
or endorsement of this ETS (dop/e): 31 March 1997
Date of withdrawal of any conflicting National Standard (dow): 31 March 1997
---------------------- Page: 7 ----------------------
SIST ETS 300 446 E1:2003
Page 6
ETS 300 446: June 1996
Blank page
---------------------- Page: 8 ----------------------
SIST ETS 300 446 E1:2003
Page 7
ETS 300 446: June 1996
1 Scope
This European Telecommunication Standard (ETS) covers the assessment of radio communication and
ancillary equipment in respect of Electro-Magnetic Compatibility (EMC). Technical specifications related to
the antenna port and emissions from the enclosure port of radio equipment are found in the related
product standards I-ETS 300 131 (1992) [3], and I-ETS 300 131 (1994) second edition [4].
This ETS specifies the minimum performance and the methods of measurements of EMC on second
generation Cordless Telephone (CT2) apparatus and ancillary equipment.
This ETS specifies the applicable EMC tests, the limits, and the performance criteria for digital radio
equipment as described in I-ETS 300 131 [3] or [4], operating in the frequency range 864,1 to 868,1 MHz,
and for the associated ancillary equipment.
The environment classification used in this ETS refers to the environment classification used in the
Generic Standards EN 50081-1 [1], EN 50082-1 [2], except the vehicular environment class which refers
to ISO 7637 [6].
The EMC requirements have been selected to ensure an adequate level of compatibility for apparatus at
residential, commercial, light industrial and vehicular environments. The levels however, do not cover
extreme cases which may occur in any location but with a low probability of occurrence.
This ETS may not cover those cases where a potential source of interference which is producing
individually repeated transient phenomena, or a continuous phenomena, is permanently present, e.g. a
radar or broadcast site in the near vicinity. In such a case it may be necessary to use special protection
applied to either the source of interference, or the interfered part, or both.
Compliance of radio equipment to the requirements of this ETS does not signify compliance to any
requirement related to the use of the equipment (i.e. licensing requirements).
Compliance to this ETS does not signify compliance to any safety requirements. However, it is the
responsibility of the assessor of the equipment that any observation regarding the equipment becoming
dangerous or unsafe as a result of the application of the tests of this ETS, should be recorded in the test
report.
2 Normative references
This ETS incorporates, by dated or undated reference, provisions from other publications. These
normative references are cited at the appropriate places in the text and the publications listed hereafter.
For dated references, subsequent amendments to or revisions of any of these publications apply to this
ETS only when incorporated in it by amendment or revision. For undated references, the latest edition of
the publication referred to applies.
[1] EN 50081-1 (1992): "Electromagnetic compatibility - Generic emission standard
- Part 1: Residential, commercial and light industry".
[2] EN 50082-1 (1992): "Electromagnetic compatibility - Generic immunity standard
- Part 1: Residential, commercial and light industry".
[3] I-ETS 300 131 (1992): "Radio Equipment and Systems (RES); Common air
interface specification to be used for the interworking between cordless
telephone apparatus in the frequency band 864.1 MHz to 868.1 MHz, including
public access services".
[4] I-ETS 300 131 (1994): 2nd Edition "Radio Equipment and Systems (RES);
Common air interface specification to be used for the interworking between
cordless telephone apparatus in the frequency band 864,1 MHz to 868,1 MHz,
including public access services".
[5] I-ETS 300 176: "Radio Equipment and Systems (RES); Digital European
Cordless Telecommunications (DECT); Approval test specification".
---------------------- Page: 9 ----------------------
SIST ETS 300 446 E1:2003
Page 8
ETS 300 446: June 1996
[6] ISO 7637 (1990): "Road vehicles - Electrical disturbance by conducting and
coupling; Part 1: Passenger cars and light commercial vehicles with nominal
12 V supply voltage"; and "Part 2: Commercial vehicles with nominal 24 V
supply voltage - Electrical transient conduction along supply lines only".
[7] EN 55022 (1994): "Limits and methods of measurement of radio interference
characteristics of information technology equipment".
[8] CISPR Publication No. 16: "Specification for radio disturbance and immunity
measuring apparatus and methods"; Part 1: "Radio disturbance and immunity
measuring apparatus".
[9] ENV 50140: "Electromagnetic compatibility - Basic immunity standard -
Radiated, radio frequency electromagnetic field; Immunity test".
[10] EN 60801-2 (1993): "Electromagnetic compatibility for industrial-process
measurement and control equipment - Part 2: Electrostatic discharge
requirements".
[11] IEC 801-4 (1988): "Electromagnetic compatibility for industrial process
measurement and control equipment; Part 4: Electrical fast transients / burst
requirements".
[12] ENV 50141: "Electromagnetic compatibility - Basic immunity standard -
Conducted disturbances induced by radio-frequency fields".
[13] EN 61000-4-11: "Electromagnetic compatibility (EMC) - Part 4: Testing and
measurement techniques - Section 11: Voltage dips, short interruptions and
voltage variations immunity tests".
[14] ENV 50142: "Electromagnetic compatibility - Basic immunity standard - Surge
immunity test".
3 Definitions and abbreviations
3.1 Definitions
For the purposes of this ETS, the following definitions apply:
ancillary equipment: Equipment (apparatus), used in connection with a receiver or transceiver is
considered as an ancillary equipment (apparatus) if:
- the equipment is intended for use in conjunction with a receiver, or transceiver to provide additional
operational and/or control features to the radio equipment (e.g. to extend control to another position
or location); and
- the equipment cannot be used on a stand alone basis to provide user functions independently of a
receiver or transceiver; and
- the receiver or transceiver to which it is connected, is capable of providing some intended operation
such as transmitting and/or receiving without the ancillary equipment (i.e. it is not a sub-unit of the
main equipment essential to the main equipment basic functions).
base station equipment: Used to describe CT2 equipment including CFPs (cordless fixed parts) and/or
CPPs (cordless portable parts) as defined in I-ETS 300 131 [3] [4] which are powered via an ac power
input port or a dc power input port.
CT2 equipment: Apparatus which includes one or more transceivers and/or receivers and/or parts
thereof which conform to the requirements of clause 4 of I-ETS 300 131 [3] [4].
---------------------- Page: 10 ----------------------
SIST ETS 300 446 E1:2003
Page 9
ETS 300 446: June 1996
host equipment: Any equipment which has a complete user functionality when not connected to the CT2
radio equipment, and to which the CT2 radio equipment provides additional functionality, and to which
connection is necessary for the CT2 radio equipment to offer functionality.
integral antenna: An antenna designed to be connected to the equipment without the use of an external
connector and considered to be part of the equipment. An integral antenna may be fitted internally or
externally to the equipment.
manufacturer: The legal entity responsible for placing the product on the market.
mobile equipment: Used to describe all CT2 equipment powered by a vehicular power supply.
port: A particular interface of the specified equipment (apparatus) with the external electro-magnetic
environment.
portable equipment: Used to describe all CT2 equipment powered by an internal battery.
NOTE: More than one of the equipment classifications may apply to certain equipment, as
described in subclause 5.2, dependent upon the manufacturer's declaration of normal
intended use.
3.2 Abbreviations
For the purposes of this ETS, the following abbreviations apply:
FP Cordless Fixed Part
CT2 second generation Cordless Telephone
CPP Cordless Portable Part
EMC Electro-Magnetic Compatibility
ESD Electro-Static Discharge
EUT Equipment Under Test
LISN Line Impedance Stabilisation Network
RF Radio Frequency
RMS Root Mean Square
SPL Sound Pressure Level
4 General test conditions
4.1 Test conditions
The equipment shall be tested under normal test conditions contained in the relevant product and basic
standards or in the information accompanying the equipment, which are within the manufacturer's
declared range of humidity, temperature, and supply voltage.
The test conditions shall be recorded in the test report.
The test configuration shall be as close to normal intended use as possible and shall be recorded in the
test report.
Whenever the Equipment Under Test (EUT) is provided with a detachable antenna, the EUT shall be
tested with the antenna fitted in a manner typical of normal intended use.
For CT2 equipment parts for which connection to a host equipment is necessary to offer functionality the
test configuration shall be as defined in subclause 5.4.
4.2 Arrangements for test signals at the input of the transceiver
4.2.1 Speech equipment
Audio input signals may be connected to the EUT either by a non-metallic acoustic tube or, if provided, by
electrical connections. The CT2 equipment shall not be modified to provide any electrical connection ports
---------------------- Page: 11 ----------------------
SIST ETS 300 446 E1:2003
Page 10
ETS 300 446: June 1996
for the purposes of this test. Suitable test arrangements for the acoustic tube are described in
I-ETS 300 176 [5].
4.3 Normal test modulation
The wanted input signal shall have the maximum peak frequency deviation which is specified in
I-ETS 300 131 [3] and [4], subclause 4.5.2.
4.4 Connection of test signals for transceivers
4.4.1 Radio Frequency (RF) connection
Where the equipment incorporates an external antenna connector, the wanted signal to establish
communications shall be delivered to that connector by a coaxial cable.
The source of the wanted input signal shall be located outside of the test environment.
Where the equipment does not incorporate an external RF connector (integral antenna equipment), the
wanted signal to establish communications shall be delivered from the equipment to an antenna located
within the test environment.
4.5 Connection of test signals for receiver-only equipment
4.5.1 RF connection
Where the equipment incorporates an external antenna connector, the wanted signal to establish
communications shall be presented to that connector by a coaxial cable.
The source of the wanted input signal shall be located outside of the test environment.
Where the equipment does not incorporate an external RF connector (integral antenna equipment), the
wanted signal, to establish communications, shall be presented to the equipment from an antenna located
within the test environment. Adequate measures shall be taken to protect the measuring equipment from
the effect of all the radiated fields within the test environment.
4.6 Receiver test signal level
For tests on receivers and the receiver parts of transceivers the level of the wanted input signal shall be
adjusted to approximately 40 dB above the radio receiver sensitivity limit as defined in I-ETS 300 131 [3]
and [4].
The source of the wanted input signal shall be located outside of the test environment.
4.7 Narrow band responses on receivers or receivers which are part of transceivers
No immunity tests shall be carried out on frequencies of identified narrow band responses (i.e. spurious
responses) of the receiver parts of the CT2 equipment.
A spurious response is defined as a failure of the communications state between a CFP or CPP and its
corresponding CPP or CFP due to the introduction of interfering radio signals, at any frequency within a
continuous frequency band of width 1 MHz or less at a lower field strength than given as the limiting value
in I-ETS 300 131 [3] and [4], subclause 4.6.3.1 at that frequency equal to the centre frequency of this
band.
The procedure by which a narrow band response is distinguished from a wide band response is as
follows:
- if during testing the communications link is dropped, or there is an increase above the permitted
level in the measured value of speech output signal level, the frequency of the unwanted signal
shall be recorded and then increased by 1 MHz and the test repeated. Similarly, the frequency of
the unwanted signal shall be set to the frequency recorded in the previous test, and then decreased
by 1 MHz and the test repeated;
---------------------- Page: 12 ----------------------
SIST ETS 300 446 E1:2003
Page 11
ETS 300 446: June 1996
- if the communications link is maintained and the speech output signal of the EUT as measured is
within the permitted limit at the two test frequencies described in the previous paragraph, then the
response observed at the recorded frequency of the unwanted signal shall be considered a narrow
band response and shall not be used in determining the EMC compliance of the EUT;
- if the communications link is dropped or the speech output signal level of the EUT as measured is
outside the permitted limits at the two test frequencies, then the test shall be repeated using
frequency offsets of plus and minus 1,5 MHz. If at one or both of this second set of test frequencies
the communications link is dropped or the speech output signal level as measured is still outside
the permitted limits, then the response is considered to be a wide band phenomena and the EUT
fails the test.
4.8 Exclusion bands
Frequencies on which the EUT is intended to operate are excluded from immunity tests with either
conducted or radiated unwanted RF signals. For the purposes of this ETS these frequencies are referred
to as "exclusion bands".
4.8.1 Exclusion band for CT2 receivers and CT2 receiver parts of transceivers
The exclusion band for a receiver or a receiver part of a transceiver shall extend from 820,9 MHz to
911,5 MHz.
4.8.2 Exclusion band for CT2 transmitter parts of transceivers
The exclusion band for the transmitter part of a transceiver shall extend from 820,9 MHz to 911,5 MHz.
NOTE: The product operates on a single frequency in a time-division multiplex mode. For this
reason, it is not practical to configure test equipment to use an exclusion band for the
transmitter that is narrower than that used for the receiver. As a result, the specified
exclusion band for transmitters has been set equal to the exclusion band for receivers.
5 Performance assessment
5.1 General
The manufacturer shall at the time of submission of the equipment for test, declare the following
information which shall be recorded in the test report:
- in the case of receive-only equipment, the primary functions of the radio equipment to be tested
during and after the EMC testing;
- the intended functions of the EUT which shall be in accordance with the documentation
accompanying the equipment;
- the ancillary equipment and/or host equipment to be used with the radio equipment for testing;
- the user-control functions and stored data that are required for normal operation and the method to
be used to assess whether these have been lost after EMC stress;
- an exhaustive list of ports, classified as either power or signal/control. Power ports shall further be
classified as ac or dc power;
- the edition of the performance standard I-ETS 300 131 [3] or [4] which the EUT is intended to meet;
- the volume setting required to provide nominal operation of the product as defined in
I-ETS 300 131 [3] or [4].
---------------------- Page: 13 ----------------------
SIST ETS 300 446 E1:2003
Page 12
ETS 300 446: June 1996
5.2 Equipment classification
Port
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.