SIST EN 13476-1:2007
(Main)Plastics piping systems for non-pressure underground drainage and sewerage - Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 1: General requirements and performance characteristics
Plastics piping systems for non-pressure underground drainage and sewerage - Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 1: General requirements and performance characteristics
This standard, together with EN 13476 2 and EN 13476 3, specifies the definitions and requirements for pipes, fittings and the system based on unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) structured-wall piping systems that are to be used for non-pressure underground drainage and sewerage systems.
This standard is applicable to:
a) structured-wall pipes and fittings, which are to be used buried in the ground outside a building structure only; reflected by the marking of products by “U”;
b) structured-wall pipes and fittings, which are to be used buried in the ground both outside (application area code “U”) and within a building structure (application area code “D”); reflected in the marking of products by “UD”.
In conjunction with EN 13476 2 and EN 13476 3 it is applicable to structured-wall pipes and fittings with or without an integral socket with elastomeric ring seal joints, as well as welded and fused joints.
This part specifies general aspects and gives guidance concerning a national selection of requirement levels and classes where part 2 and part 3 of this standard provide options.
EN 13476 2 and EN 13476 3 specify material characteristics, dimensions and tolerances, test methods, test parameters and requirements for pipes with smooth internal and external surfaces, Type A, and pipes with smooth internal and profiled external surfaces, Type B.
This standard covers a range of pipe and fitting sizes, materials, pipe constructions, stiffness classes and tolerance classes and offers recommendations concerning colours.
NOTE 1 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
NOTE 2 Pipes, fittings and other components conforming to any plastic product standards referred to in clause 2 can be used with pipes and fittings conforming t
Kunststoff-Rohrleitungssysteme für erdverlegte drucklose Abwasserkanäle und -leitungen - Rohrleitungssysteme mit profilierter Wandung aus weichmacherfreiem Polyvinylchlorid (PVC-U), Polypropylen (PP) und Polyethylen (PE) - Teil 1: Allgemeine Anforderungen und Leistungsmerkmale
Diese Europäische Norm legt gemeinsam mit EN 13476-2 und EN 13476-3 Definitionen und allgemeine Anforderungen an Rohre, Formstücke und das Rohrleitungssystem aus weichmacherfreiem Polyvinylchlorid (PVC-U), Polypropylen (PP) und Polyethylen (PE) mit profilierter Wandung fest, die für erdverlegte, drucklos betriebene Abwasserkanäle und leitungen verwendet werden.
Diese Norm gilt für:
a) Rohre und Formstücke mit profilierter Wandung, die ausschließlich für erdverlegte Anwendungen außerhalb einer Gebäudestruktur vorgesehen sind; gekennzeichnet mit Anwendungs¬kennzeichen „U“;
b) Rohre und Formstücke mit profilierter Wandung, die sowohl für erdverlegte Anwendungen außerhalb der Gebäudestruktur (Anwendungskennzeichen „U“) als auch innerhalb einer Gebäudestruktur (Anwendungs¬kennzeichen „D“) vorgesehen sind; gekennzeichnet mit Anwendungs¬kennzeichen „UD“.
Gemeinsam mit EN 13476-2 und EN 13476-3 gilt dieser Teil für Rohre und Formstücke mit profilierter Wandung sowohl mit glatten Enden als auch mit angeformter Muffe mit elastomeren Dichtringverbindungen bzw. Verbindung durch Heizelement-Stumpf-, Extrusions- oder Heizwendelschweißen.
Dieser Teil legt allgemeine Aspekte fest und enthält Empfehlungen zur Auswahl nationaler Anforderungsstufen und -klassen, wofür Teil 2 und Teil 3 dieser Norm die Optionen enthält.
EN 13476-2 und EN 13476-3 legen Werkstoffeigenschaften, Maße und Toleranzen, Prüfverfahren, Prüfparameter und Anforderungen für Rohre mit glatten Innen- und Außenflächen, Typ A, sowie Rohre mit glatten Innen- und profilierten Außenflächen, Typ B, fest.
Diese Norm enthält, gemeinsam mit EN 13476-2 und EN 13476-3, Festlegungen für Maße von Rohren und Formstücken, für Werkstoffe, Rohrkonstruktionen, für Steifigkeitsklassen und Toleranzklassen und gibt Empfehlungen für die Einfärbung.
ANMERKUNG 1 Der Käufer bzw. Auftraggeber ist unter Berücksichtigung der eigenen Anforderungen sowie der geltenden nationalen
Systemes de canalisations en plastique pour les branchements et les collecteurs d'assainissements sans pression enterrés - Systemes de canalisation a parois structurées en poly(chlorure de vinyle) non plastifié (PVC-U), polypropylene (PP) et polyéthylene (PE) - Partie 1: Exigences générales et caractéristiques de performance
Cevni sistemi iz polimernih materialov za odvodnjavanje in kanalizacijo, ki delujejo po težnostnem principu in so položeni v zemljo - Cevni sistemi s strukturirano steno iz nemehčanega polivinilklorida (PVC-U), polipropilena (PP) in polietilena (PE) - 1. del: Splošne zahteve in zahtevane lastnosti
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Plastics piping systems for non-pressure underground drainage and sewerage - Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 1: General requirements and performance characteristicsSystemes de canalisations en plastique pour les branchements et les collecteurs d'assainissements sans pression enterrés - Systemes de canalisation a parois structurées en poly(chlorure de vinyle) non plastifié (PVC-U), polypropylene (PP) et polyéthylene (PE) - Partie 1: Exigences générales et caractéristiques de performanceKunststoff-Rohrleitungssysteme für erdverlegte drucklose Abwasserkanäle und -leitungen - Rohrleitungssysteme mit profilierter Wandung aus weichmacherfreiem Polyvinylchlorid (PVC-U), Polypropylen (PP) und Polyethylen (PE) - Teil 1: Allgemeine Anforderungen und LeistungsmerkmaleTa slovenski standard je istoveten z:EN 13476-1:2007SIST EN 13476-1:2007en;fr;de93.030Zunanji sistemi za odpadno vodoExternal sewage systems23.040.20Cevi iz polimernih materialovPlastics pipesICS:SLOVENSKI
STANDARDSIST EN 13476-1:200701-julij-2007
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13476-1May 2007ICS 93.030 English VersionPlastics piping systems for non-pressure underground drainageand sewerage - Structured-wall piping systems of unplasticizedpoly(vinyl chloride) (PVC-U), polypropylene (PP) andpolyethylene (PE) - Part 1: General requirements andperformance characteristicsSystèmes de canalisations en plastique pour lesbranchements et les collecteurs d'assainissements sanspression enterrés - Systèmes de canalisation à paroisstructurées en poly(chlorure de vinyle) non plastifié (PVC-U), polypropylène (PP) et polyéthylène (PE) - Partie 1:Exigences générales et caractéristiques de performanceKunststoff-Rohrleitungssysteme für erdverlegte druckloseAbwasserkanäle und -leitungen - Rohrleitungssysteme mitprofilierter Wandung aus weichmacherfreiemPolyvinylchlorid (PVC-U), Polypropylen (PP) undPolyethylen (PE) - Teil 1: Allgemeine Anforderungen undLeistungsmerkmaleThis European Standard was approved by CEN on 5 March 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2007 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13476-1:2007: E
EN 13476-1:2007 (E) 2 Contents Page Foreword 4 Introduction 5 1 Scope 6 2 Normative references 6 3 Terms and definitions, symbols and abbreviations 7 3.1 Definitions 7 3.1.1 General definitions 7 3.1.2 Geometrical definitions 8 3.2 Symbols and abbreviations 9 4 Material 10 4.1 General 10 4.2 Utilisation of non-virgin material 10 4.3 Sealing ring retaining components 10 4.4 Sealing rings 10 4.5 Fused or welded joints 10 5 Designation of wall construction 10 6 Appearance and colour 10 6.1 Appearance 10 6.2 Colour 11 7 Geometrical characteristics 11 8 Types of fittings 11 8.1 General 11 8.2 Design length of fittings 14 9 System performance related test methods and characteristics 14 10 Marking, general 16 10.1 Presentation 16 10.2 Marking process 16 10.3 Size 16 Annex A (informative)
Characteristics of PVC-U, PP and PE pipes and fittings 17 A.1 General 17 A.2 Material characteristics 17 A.3 Chemical resistance 17 A.4 Abrasion resistance 18 A.5 Hydraulic roughness 18 Annex B (informative)
Structural design 19 B.1 General 19 B.2 Structural design based on practical experience 19 B.3 Structural design based on a design calculations 21 B.4 Selection of fitting stiffness or class 21 Annex C (informative)
Designation of pipes and corresponding fittings 23 Annex D (informative)
Guidance in cleaning plastics pipes 24 D.1 Introduction 24 D.2 Cleaning and unblocking 24
EN 13476-1:2007 (E) 3 D.2.1 Choosing the right equipment 24 D.2.2 Comparing techniques 24 D.3 Conclusions from independent jetting tests 25 D.3.1 Assessing efficiency and impact 25 D.3.2 Testing of plastic pipes 25 D.3.3 Clearing tests 25 D.4 Supplementary cleaning techniques 26 D.5 Recommended practice principles for jetting 26 Bibliography 28
EN 13476-1:2007 (E) 4 Foreword This document (EN 13476-1:2007) has been prepared by Technical Committee CEN/TC 155 “Plastics piping systems and ducting systems”, the secretariat of which is held by NEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by November 2007, and conflicting national standards shall be withdrawn at the latest by November 2007. This standard is a part of a System Standard for plastics piping systems of particular materials for specified applications. There are a number of such System Standards. System Standards are based on the results of the work being undertaken in ISO/TC 138 “Plastics pipes, fittings and valves for the transport of fluids”, which is a Technical Committee of the International Organization for Standardization (ISO). They are supported by separate standards on test methods to which references are made throughout the System Standard. The System Standards are consistent with general standards on functional requirements and on recommended practice for installation. EN 13476 consists of the following Parts under the general title Plastics piping systems for non-pressure underground drainage and sewerage — Structured-wall piping systems of unplasticized poly(vinyl chloride)
(PVC-U), polypropylene (PP) and polyethylene (PE): — Part 1: General requirements and performance characteristics (this standard); — Part 2: Specifications for pipes and fittings with smooth internal and external surface and the system, Type A; — Part 3: Specifications for pipes and fittings with smooth internal and profiled external surface and the system, Type B; — Part 4: Assessment of conformity (CEN/TS); — Part 5: Guidance for installation (CEN/TS).1 For pipes and fittings which have conformed to the relevant national standard before May 2007, as shown by the manufacturer or by a certification body, the national standard may continue to be applied until May 2009.
National standards specifically for pipes and fittings for the transport of surface water are not considered to be conflicting with this standard and may thus be allowed to coexist. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
1 The feasibility of this project is under study.
EN 13476-1:2007 (E) 5
Introduction Due to the variety in materials, pipe constructions, application areas and classes, several combinations are possible. The purchaser or specifier may select between these possibilities by designating the pipe and fitting he or she prefers to use for each case, as described in Annex C, Designation of pipes and corresponding fittings, taking into account any particular requirements and relevant national regulations and installation practices or codes.
EN 13476-1:2007 (E) 6 1 Scope This European Standard, together with EN 13476-2 and EN 13476-3, specifies the definitions and general requirements for pipes, fittings and the system based on unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) structured-wall piping systems that are to be used for non-pressure underground drainage and sewerage systems. This standard is applicable to: a) structured-wall pipes and fittings, which are to be used buried in the ground outside a building structure only; reflected by the marking of products by “U”; b) structured-wall pipes and fittings, which are to be used buried in ground both outside (application area code “U”) and within a building structure (application area code “D”); reflected in the marking of products by “UD”. In conjunction with EN 13476-2 and EN 13476-3 it is applicable to structured-wall pipes and fittings with or without an integral socket with elastomeric ring seal joints, as well as welded and fused joints. This part specifies general aspects and gives guidance concerning a national selection of requirement levels and classes where part 2 and part 3 of this standard provide options. EN 13476-2 and EN 13476-3 specify material characteristics, dimensions and tolerances, test methods, test parameters and requirements for pipes with smooth internal and external surfaces, Type A, and pipes with smooth internal and profiled external surfaces, Type B. This standard, together with EN 13476-2 and EN 13476-3, covers a range of pipe and fitting sizes, materials, pipe constructions, stiffness classes and tolerance classes and offers recommendations concerning colours. NOTE 1 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
NOTE 2 Pipes, fittings and other components conforming to any plastic product standards referred to in clause 2 can be used with pipes and fittings conforming to this standard, when they conform to the requirements for joint dimensions given in part 2 and part 3 of this standard and to the performance requirements given in Clause 9. NOTE 3
For dimensions larger than DN 1200 OD/ID this document may serve as general guideline regarding appearance, colour, physical and mechanical characteristics as well as performance requirements. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 681-1, Elastomeric seals — Materials requirements for pipe joint seals used in water and drainage applications — Part 1: Vulcanized rubber EN 681-2, Elastomeric seals — Materials requirements for pipe joint seals used in water and drainage applications — Part 2: Thermoplastic elastomers EN 681-4, Elastomeric seals — Materials requirements for pipe joint seals used in water and drainage applications — Part 4: Cast polyurethane sealing elements EN 13476-2:2007,
Plastics piping systems for non-pressure underground drainage and sewerage - Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 2: Specifications for pipes and fittings with smooth internal and external surface and the system, Type A
EN 13476-1:2007 (E) 7 EN 13476-3:2007,
Plastics piping systems for non-pressure underground drainage and sewerage - Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 3: Specifications for pipes and fittings with smooth internal and profiled external surface and the system, Type B EN ISO 472:2001, Plastics — Vocabulary (ISO 472:1999) EN ISO 1043-1:2001, Plastics - Symbols and abbreviated terms - Part 1: Basic polymers and their special characteristics (ISO 1043-1:2001) EN ISO 9969, Thermoplastics pipes — Determination of ring stiffness (ISO 9969:1994) ISO 11922-1:1997, Thermoplastics pipes for the conveyance of fluids — Dimensions and tolerances — Part 1: Metric series ISO 13967, Thermoplastics fittings — Determination of ring stiffness 3 Terms and definitions, symbols and abbreviations For the purposes of this standard, the terms and definitions given in EN ISO 472:2001, EN ISO 1043-1:2001, ISO 11922-1:1997 and the following apply. 3.1 Definitions
3.1.1 General definitions 3.1.1.1 application area code code used to mark pipes and fittings to indicate the permitted application area(s) for which they are intended, as follows:
U: code for the area more than 1 m from the building to which the buried piping system is connected;
D: code for the area under and within 1 m from the building where the pipes and fittings are buried
underground and are connected to the soil and waste discharge system of the building NOTE In the “D” application area, the existence of hot water discharge in addition to external forces from the surroundings is usual. 3.1.1.2 structured-wall pipes and fittings products which have an optimised design with regard to material usage to achieve the physical, mechanical and performance requirements of this standard NOTE For a description of the particular designs covered by this standard, see clause 5 in EN 13476-2:2007 and EN 13476-3:2007. 3.1.1.3 fabricated fitting fitting manufactured by heat forming and/or joining more than one piece of pipe and/or moulded component NOTE Sealed ring retaining components are not considered as a piece.
EN 13476-1:2007 (E) 8 3.1.2 Geometrical definitions 3.1.2.1 nominal size, DN numerical designation of the size of a component, other than a component designated by thread size, which is approximately equal to the manufacturing dimension in mm 3.1.2.2 nominal size, DN/OD nominal size, related to the outside diameter 3.1.2.3 nominal size, DN/ID nominal size, related to the inside diameter 3.1.2.4 nominal diameter dn specified diameter, in mm, assigned to a nominal size (DN/OD or DN/ID) 3.1.2.5 outside diameter de value of the measurement of the outside diameter through its cross-section at any point of a pipe or spigot, rounded to the next greatest 0,1 mm NOTE For Type B constructions, see EN 13476-3. 3.1.2.6 mean outside diameter dem value of the measurement of the outer circumference of a pipe or spigot in any cross-section divided by π (pi = 3,142), rounded to the next greatest 0,1 mm NOTE For Type B constructions, see EN 13476-3. 3.1.2.7 mean inside diameter dim average value of a number of equally spaced measurements of inside diameter in the same cross-section of a pipe or fitting 3.1.2.8 wall thickness e measured wall thickness at any point of the body of a component 3.1.2.9 construction height ec radial distance between the top of ribs or corrugation or, in case of Type A1 and Type A2 pipes and fittings, the external surface of the wall and the internal surface of the wall 3.1.2.10 ring flexibility ability of a pipe to resist diametric deflection without the loss of structural integrity
EN 13476-1:2007 (E) 9 3.1.2.11 ring stiffness mechanical characteristic of a pipe, which is a measure of the resistance to ring deflection under an external force as determined in accordance with EN ISO 9969
3.1.2.12 fitting stiffness mechanical characteristic of a fitting which is a measure of the resistance to ring deflection under an external force as determined in accordance with ISO 13967 3.1.2.13 ring stiffness class, SN numerical designation of the ring stiffness of the pipe or fitting which is a convenient round number, indicating the minimum required ring stiffness of the pipe or stiffness of the fitting 3.2 Symbols and abbreviations dn,1 nominal diameter of the main of a branch/saddle branch dn,2 nominal diameter of the branch of a branch/saddle branch L axial cover by a saddle branch Z1 design length of a fitting Z2 design length of a fitting Z3 design length of a fitting . nominal angle of fitting DN nominal size DN/ID nominal size related to inside diameter DN/OD nominal size related to outside diameter PE polyethylene PP polypropylene PP-MD Mineral modified PP
PVC-U unplasticized poly(vinyl chloride) RF ring flexibility performance S pipe series S SDR standard dimension ratio SN ring stiffness class
EN 13476-1:2007 (E) 10 4 Material 4.1 General The material shall be one of the materials specified in the relevant annexes of EN 13476-2 or EN 13476-3, as applicable. NOTE Information about general material characteristics is given in Annex A. 4.2 Utilisation of non-virgin material The specifications for the material and levels of permitted addition are specified in EN 13476-2 or EN 13476-3. 4.3 Sealing ring retaining components It is permitted that sealing rings are retained using components made from polymers other than PVC U, PP or PE. 4.4 Sealing rings The sealing ring material shall conform to EN 681-1, EN 681-2 or EN 681-4, as applicable. The sealing ring shall have no detrimental effects on the component properties. 4.5 Fused or welded joints When fused or welded joints are used, the component manufacturer's instructions for jointing shall be followed. 5 Designation of wall construction Pipes and fittings with smooth internal and external surfaces are designated as Type A. Pipes and fittings with smooth internal and profiled external surfaces are designated as Type B. Definitions of wall constructions including schematic sketches and examples of typical jointing methods are given in EN 13476-2 for Type A pipes and in EN 13476-3 for Type B pipes. 6 Appearance and colour 6.1 Appearance When viewed without magnification the following requirements apply: a) visible surfaces of pipes and fittings shall be smooth, clean and free from grooving, blistering, visible impurities or pores and any other surface irregularity likely to prevent conformity to this standard; b) pipe and fittings ends shall be cleanly cut square to the axis of the pipe, and within any cutting zone recommended by the manufacturer, or according to the profile geometry as specified by the manufacturer; c) edges on spirally formed pipes and fittings which become sharp when cut, shall be rounded off.
EN 13476-1:2007 (E) 11 6.2 Colour The inner and outer layer of pipes and fittings shall be coloured throughout. The external layer of pipes and fittings should preferably be black, orange-brown (approximately RAL 8023 [1]) or dusty grey (approximately RAL 7037 [1]). Other colours may be used. 7 Geometrical characteristics This standard specifies nominal sizes for DN/ID given in Table 1 and for DN/OD given in Table 2
Table 1 - Nominal sizes DN/ID Nominal sizes: DN/ID (in mm) 100, 125, 150, 200, 225, 250, 300, 400, 500, 600, 800, 1 000, 1 200
Table 2 - Nominal sizes DN/OD Nominal sizes: DN/OD (in mm) 110, 125, 160, 200, 250, 315, 400, 500, 630, 800, 1 000, 1 200 Other sizes are permitted when following the conditions given in EN 13476-2 or EN 13476-3. 8 Types of fittings 8.1 General This standard is applicable for the following types of fittings.
Figures 1 to 7 give examples for typical designs. Other designs of fittings including all socket and all spigot, are permitted. a) Bends un-swept and swept angle (see Figure 1 and Figure 2). NOTE 1 Preferred nominal angles, ., are the following: 15°, 22,5°, 30°, 45° and between 87,5° and 90°.
Figure 1 — Example of an un-swept bend
EN 13476-1:2007 (E) 12
Figure 2 — Example of a swept bend
b) Couplers and slip couplers (see Figure 3).
Figure 3 — Example of coupler and slip coupler
c) Reducers (see Figure 4).
Figure 4 — Example of reducer d) Branches and reducing branches un-swept and swept entry (see Figure 5). NOTE 2 Preferred nominal angles, ., are 45° and between 87,5° and 90°.
EN 13476-1:2007 (E) 13
Figure 5 — Example of a swept entry and a straight branch
e) Saddle branches for solvent cementing, fusion or welding (see Figure 6): — axial cover, L, in mm, shall conform to the following:
Table 3 - Axial cover of saddle branches Dimensions in millimetres
dn2 ≤≤≤≤ 110 110 < dn2 ≤≤≤≤ 125 125 < dn2 ≤≤≤≤ 160 160 < dn2 ≤≤≤≤ 200 L ≥ 50 ≥ 60 ≥ 70 ≥ 80
— saddles having dn1 < 315 mm, the cover shall be not less than half a circumference, see Figure 6 key 1; — saddles having dn1 ≥ 315 mm, the circumferential cover, a, shall not be less than 80 mm, see Figure 6 key 2. NOTE 3 The preferred nominal angle, ., for saddle branches is 45°. When (dn2/dn1) ≤ 2/3; the nominal angle, ., can be 90°.
EN 13476-1:2007 (E) 14
Key
1 dn1 < 315 2 dn1 ≥ 315 Figure 6 — Example of a solvent cementing, fusion or welding saddle f) Plugs (see Figure 7). — insert length, L1, shall be sufficient to ensure engagement of the sealing ring of at least 10 mm:
a) when measured from the effective sealing point to the end of the cylindrical part of the spigot when the sealing ring is positioned in the socket, or
b) when measured from the effective sealing point to the mouth of the cylindrical part of the socket when the sealing ring is positioned on the spigot.
Figure 7 — Example of a plug 8.2 Design length of fittings The design length(s) (Z-lengths) of the fittings (see Figure 1 to Figure 6) shall be declared by the manufacturer. NOTE The design lengths (Z-lengths) are intended to assist with the design of moulds and are not intended to be used for quality control purposes, ISO 265-1[2] can be used as a guideline. 9 System performance related test methods and characteristics The performance of the installed piping system depends on the quality of the system components and installation conditions and workmanship. The performance requirements of the system components and their relation to the tested characteristics specified in EN 13476-2 or EN 13476-3, as applicable, are explained in Table 4. Annex B gives guidelines for structural design.
EN 13476-1:2007 (E) 15 Table 4 — Relationship between system performance and tested characteristics
Reference System Performance Tested characteristic EN 13476-2 EN 13476-3 Test Method Pipes Impact strength Tensile strength of seam Table 15 Table 14 EN 744 [3] or EN 1411 [4] EN 1979 [5] Handling, transport, storing and installation robustness Fittings Impact strength Table 17 Table 16 EN 12061[6] Pipes Ring stiffness
Ring flexibility
Tensile strength of seam Creep ratio Table 15 Table 14 EN ISO 9969
(6.3 of EN 476:1997 [7]) EN 1446 [8] EN 1979 [5] EN ISO 9967 [9]
(6.3 of EN 476:1997 [7]) Resistance to soil load including traffic load, both during and after installation Fittings Ring stiffness
Mechanical strength or flexibility of fabricated fitting Table 17 Table 16 ISO 13967 /same stiffness class as pipe if same wall construction as pipe EN 12256 [10] Ability to hold fluid inside and outside the system (leak tightness) System Dimensions and tolerances Tightness
Long-term performance of TPE seals Water tightness
– fabricated fittings
Tensile test of welded and fused joints 7 Table 18
Table 18
Table 18
Table 18 7 Table 17
Table 17
Table 17
Table 17 EN ISO 3126 [11] EN 1277 [12]
(6.5 of EN 476:1997 [7]) EN 14741 [13] EN 1053 [14]
6.5 of EN 476:1997 [7] EN 1979 [5] Resistance to high temperature System Elevated temperature cycling - for sizes up to 160 mm (ID)/200m (OD)
Box loading Table 18 Table 17 EN 1055:1996 [15],
assembly B, Figure 2 (8.2 of EN 476:1997 [7]) Method A or B of EN 1437 [16] Cleaning and maintenance System Rodding Flushing – High volume low pressure High pressure cleaning
See a Pipes Resistance to dichloromethane Resistance to heating – oven test – Type B Longitudinal reversion – Type A Table 9 na
Table 9, 11, 13 Table 8 Table 8, 10, 12 na EN 580 [17] (PVC only) ISO 12091 [18]
EN ISO 2505 [19] Durability, processing Fittings Resistance to heating – oven test Table 10, 12, 14 Table 9, 11, 13 EN ISO 580 [39] Durability, material Material Resistance to internal pressure
Chemical resistance Thermal stability, raw material Table 1, 2, 3, 4
Table 2,3,4 Table 1, 2, 3, 4
Table 2, 3, 4 EN ISO 1167-1 [20] and EN ISO 1167-2 [21] ISO/TR 10358 [22] EN 728 [23] (PE and PP only) a Test methods for cleaning and maintenance are not included in this standard. Experience has shown that the wall thickness, impact resistance and material requirements given in EN 13476-2 or EN 13476-3, as applicable, ensure that the systems can resist the normal cleaning procedures. See also Annex D for guidance on practical cleaning
EN 13476-1:2007 (E) 16 10 Marking, general 10.1 Presentation Marking elements shall be printed or formed directly on the component or be on a label in such a way that after storage, handling and installation, the required legibility is maintained. Three levels of legibility of the marking on components are specified for the individual marking aspects given in EN 13476-2 and EN 13476-3. The required legibility of marking is coded as follows: a) durable in use; b) legible at least until the system is installed; c) marking on the packaging is legible at least until the component is installed. NOTE The manufacturer is not responsible for marking becoming illegible due to actions during installation and use such as painting, scratching, covering of the components or by use of e.g. detergents on the components, unless agreed with, or specified by the manufacturer. 10.2 Marking process Marking shall be carried out so it does not initiate cracks or other types of defects which are likely to prevent conformity to this standard. 10.3 Size The size of the marking shall be such that the marking is legible without magnification.
EN 13476-1:2007 (E) 17 Annex A (informative)
Characteristics of PVC-U, PP and PE pipes and fittings A.1 General EN 476 [7] specifies general requirements for components used in discharge pipes, drains and sewers for gravity systems. Pipes and fittings conforming to this standard meet these requirements.
A.2 Material characteristics The materials of pipes and fittings conforming to this standard have the characteristics given in Table A 1. Table A.1 Characteristic PVC-U PP PE Unit Modulus of elasticity, E (1min) ≥ 3 200 ≥ 1 250 ≥ 800 MPa Average density ≈ 1400 ≈ 900 ≈ 940 kg/m3 Average coefficient of linear thermal expansion ≈ 8 × 10-5 ≈ 14 × 10-5 ≈ 17 × 10-5 K-1 Thermal conductivity ≈ 0,16 ≈ 0,2 ≈ (0,36 to 0,50) WK-1m-1 Specific heat capacity ≈ (850 to 2 000) ≈ 2000 ≈ (2 300 to 2 900) Jkg-1K-1 Surface resistance > 1012 > 1012 > 1013
Poisson ratio
0,4 0,42 0,45 (-) NOTE Values are dependent on the material used. Therefore, it is recommended to contact the manufacturer, or see the manufacturer's documentation, for the relevant values in each individual case.
If information regarding the tensile strength and/or elongation of break of a material is needed, they can be determined in accordance with EN ISO 6259-1 [24] combined with EN ISO 6259-2 [25] or EN ISO 6259-3 [26] as applicable. A.3 Chemical resistance Piping systems conforming to this standard are resistant to corrosion by water with a wide range of pH values such as domestic wastewater, rainwater, surface water and ground water. If piping systems conforming to this standard are to be used for chemically contaminated wastewaters, such as industrial discharges, chemical and temperature resistance have to be taken into account. For information about the chemical resistance of PVC, PP and PE materials, guidance is given in ISO/TR 10358 [22] and for rubber materials in ISO/TR 7620 [27].
EN 13476-1:2007 (E) 18 A.4 Abrasion resistance Pipes and fittings conforming to this standard are resistant to abrasion.
The abrasion can be determined from the test method given in EN 295-3:1991 [28]. A.5 Hydraulic roughness The internal surfaces of pipes and fittings conforming to this standard are hydraulically smooth. The design of joints and fittings ensure good hydraulic performances. For further information about hydraulic capacity of pipes and fittings conforming to this standard refer to the manufacturer’s information.
EN 13476-1:2007 (E) 19 Annex B (informative)
Structural design B.1 General In general creating a structural design of a thermo-plastics pipeline construction by applying analytical or numerical methods is not needed. Any calculated prediction of the pipe behaviour and reality is strongly dependent on the conditions used for the calculation being the same as used for the installation. Therefore, it is important that effort is put into controlling the input values by extensive soil surveys and monitoring the installation. In many cases, practical and/or reference information is available and results in a sound prediction of the pipe performance. B.2 Structural design based on practical experience The following method described below fulfils 4.2 of EN 1610:1997 [29]. Designers first need to establish permitted deflections, average and maximum. (National requirements, product standards, this standard etc. offer guidance.) An intensive study of the deflection history of pipes installed under different conditions up to 25 years ago has resulted in experience as presented in the design graph shown in Figure B.1. For the deflection mentioned in the design graph, the strain will be far below the design limit.
EN 13476-1:2007 (E) 20
Key A “NONE” compaction, not recommended
1 Pipe deflection (%)
B “MODERATE” compaction
2 Ring stiffness (kN/m2) C “WELL” compaction Figure B.1 — Design graph — Long-term pipe deflection, maximum values
EN 13476-1:2007 (E) 21 The design graph according to Figure B.1 is valid under the
...