oSIST prEN 16121:2021
(Main)Non-domestic storage furniture - Requirements for safety, strength, durability and stability
Non-domestic storage furniture - Requirements for safety, strength, durability and stability
This document specifies requirements for the safety, strength, and durability for all types of non-domestic storage furniture.
It does not apply to domestic storage, industrial storage, kitchen, catering equipment, retail storage, and industrial storage lockers.
Requirements for strength and durability do not apply to the structure of the building for example the strength of wall hanging cabinets includes only the cabinets and the parts used for attachment. The wall and the wall attachments are not included.
The standard contains five annexes
Annex A (normative) Test methods for finger entrapment;
Annex B (normative) Requirements for schools, kindergartens and similar applications
Annex C (normative) Selecting product from a range of furniture
Annex D (informative) Guidance of test severity in relation to application
Annex E (informative) Suggested loads for tests not specified in this standard
It does not include requirements for the resistance to ageing, degradation and flammability.
Behältnismöbel für den Nicht-Wohnbereich - Anforderungen an die Sicherheit, Festigkeit, Dauerhaltbarkeit und Standsicherheit
Dieses Dokument legt Anforderungen an die Sicherheit, Festigkeit und Dauerhaltbarkeit für alle Arten von Behältnismöbeln für den Nicht-Wohnbereich einschließlich Behältnismöbeln im Bürobereich fest.
Es gilt nicht für Behältnismöbel im Wohnbereich, Industriebereich, für Küchen und Gastronomie- Einrichtungen, für Lagereinrichtungen im Einzelhandel und für Industrie-Schließfächer.
Anforderungen an die Festigkeit und Dauerhaltbarkeit gelten nicht für die Konstruktion eines Gebäudes, bei
spielsweise gilt die Festigkeit von Wandhängeschränken nur für die Schränke und für die Teile, die zur
gung verwendet werden. Die Wand selbst und die wandseitigen Befestigungsmittel sind darin nicht enthalten.
Dieses Dokument enthält fünf Anhänge:
—
AnhangA (normativ): Prüfverfahren für Fingerfangstellen sowie Scher- und Klemmstellen;
—
AnhangB (normativ): Anforderungen an Möbel für Schulen, Kindergärten und ähnliche Einrichtungen;
—
AnhangC (normativ): Auswahl eines Produktes aus einem Möbelsortiment;
—
AnhangD (informativ): Leitlinien für die Prüfstufen im Verhältnis zur Anwendung für Behältnismöbel für den Nicht-Wohnbereich;
—
AnhangE (informativ): Vorgeschlagene Prüflasten für Prüfungen, die in diesem Dokument nicht festgelegt sind.
Es sind keine Anforderungen an die Beständigkeit gegen Alterung, Abnutzung und Entflammbarkeit enthalten.
Meubles de rangement à usage collectif - Exigences pour la sécurité, la résistance, la durabilité et la stabilité
Shranjevalno pohištvo za javno uporabo - Zahteve za varnost, trdnost, trajnost in stabilnost
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
oSIST prEN 16121:2021
01-december-2021
Shranjevalno pohištvo za javno uporabo - Zahteve za varnost, trdnost, trajnost in
stabilnost
Non-domestic storage furniture - Requirements for safety, strength, durability and
stability
Behältnismöbel für den Nicht-Wohnbereich - Anforderungen an die Sicherheit, Festigkeit,
Dauerhaltbarkeit und Standsicherheit
Meubles de rangement à usage collectif - Exigences pour la sécurité, la résistance, la
durabilité et la stabilité
Ta slovenski standard je istoveten z: prEN 16121
ICS:
97.140 Pohištvo Furniture
oSIST prEN 16121:2021 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
oSIST prEN 16121:2021
---------------------- Page: 2 ----------------------
oSIST prEN 16121:2021
DRAFT
EUROPEAN STANDARD
prEN 16121
NORME EUROPÉENNE
EUROPÄISCHE NORM
October 2021
ICS 97.140 Will supersede EN 14073-2:2004, EN
16121:2013+A1:2017
English Version
Non-domestic storage furniture - Requirements for safety,
strength, durability and stability
Meubles de rangement à usage collectif - Exigences Behältnismöbel für den Nicht-Wohnbereich -
pour la sécurité, la résistance, la durabilité et la Anforderungen an die Sicherheit, Festigkeit,
stabilité Dauerhaltbarkeit und Standsicherheit
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 207.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 16121:2021 E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
oSIST prEN 16121:2021
prEN 16121:2021 (E)
Contents Page
European foreword . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 6
4 Test sequence and tolerances . 8
4.1 Individual units . 8
4.2 Range of units . 8
4.3 Tolerances . 8
5 Safety requirements . 8
5.1 Principles of safety requirements . 8
5.1.1 General. 8
5.1.2 Determination of centre of gravity . 9
5.1.3 Determination of total mass . 9
5.2 General safety requirements . 9
5.3 Holes in tubular/rigid components . 10
5.4 Shear and compression points . 10
5.4.1 Shear and compression points when setting up and folding . 10
5.4.2 Shear and compression points under influence of powered mechanisms . 10
5.4.3 Shear and compression points during use . 10
5.5 Hinged horizontal lids . 11
5.6 Vertical glass components . 11
5.7 Stability . 11
5.8 Structural safety . 13
5.8.1 Structural safety tests. 13
5.8.2 Structural safety requirements . 15
6 Strength and durability . 15
6.1 General. 15
6.2 Strength and durability requirements . 17
7 Information for use . 17
8 Test report . 17
Annex A (normative) Test methods for finger entrapment and shear and compression . 18
A.1 Finger entrapment . 18
A.1.1 Test equipment . 18
A.1.2 Test method . 19
A.2 Shear and compression . 21
A.2.1 Test equipment . 21
A.2.2 Test method - Shear and compression points created under the influence of powered
mechanisms . 22
2
---------------------- Page: 4 ----------------------
oSIST prEN 16121:2021
prEN 16121:2021 (E)
A.2.3 Test method - Shear and compression points created during normal use . 23
Annex B (normative) Requirements for schools, kindergartens and similar applications . 24
B.1 General . 24
B.2 Requirements . 24
B.2.1 General . 24
B.3 Additional requirements for furniture for kindergartens . 25
B.3.1 Finger entrapment . 25
Annex C (normative) Selecting product from a range of furniture . 26
C.1 Range of units . 26
Annex D (informative) Guidance of test severity in relation to application for non-domestic
storage furniture. 27
Annex E (informative) Suggested loads for tests not specified in this document . 28
E.1 Suggested loads for tests not specified in this document . 28
E.1.1 General . 28
E.1.2 Stability . 28
E.1.3 Strength and durability . 28
3
---------------------- Page: 5 ----------------------
oSIST prEN 16121:2021
prEN 16121:2021 (E)
European foreword
This document (prEN 16121:2021) has been prepared by Technical Committee CEN/TC 207 “Furniture”,
the secretariat of which is held by UNI.
This document is currently submitted to the CEN Enquiry.
This document will supersede EN 16121:2013+A1:2017 and EN 14073-2:2004.
In comparison with the previous edition, the following technical modifications have been made:
• Update on the requirements for finger entrapment reflecting CEN/TR 17202:2018 including an
Annex containing test methods;
• Normative references have been updated;
• Requirements for glass have been improved;
• Finger entrapment/shear squeeze requirements have been corrected and made applicable to
kindergarten only;
• Office and laboratory storage have been added to the list of applications;
• Test load added in Annex D.
4
---------------------- Page: 6 ----------------------
oSIST prEN 16121:2021
prEN 16121:2021 (E)
1 Scope
This document specifies requirements for the safety, strength, and durability for all types of non-domestic
storage furniture including office storage furniture.
It does not apply to domestic storage, industrial storage, kitchen, catering equipment, retail storage, and
industrial storage lockers.
Requirements for strength and durability do not apply to the structure of the building for example the
strength of wall hanging cabinets includes only the cabinets and the parts used for attachment. The wall
and the wall attachments are not included.
This document contains five annexes:
— Annex A (normative) Test methods for finger entrapment and shear and compression;
— Annex B (normative) Requirements for schools, kindergartens and similar applications;
— Annex C (normative) Selecting product from a range of furniture;
— Annex D (informative) Guidance of test severity in relation to application for non-domestic storage
furniture;
— Annex E (informative) Suggested loads for tests not specified in this document.
It does not include requirements for the resistance to ageing, degradation and flammability.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 71-1:2014+A1:2018, Safety of toys - Part 1: Mechanical and physical properties
EN 716-2:2017, Furniture - Children's cots and folding cots for domestic use - Part 2: Test methods
EN 12150-1:2015+A1:2019, Glass in building - Thermally toughened soda lime silicate safety glass - Part
1: Definition and description
EN 12600, Glass in building - Pendulum test - Impact test method and classification for flat glass
EN 14072:2003, Glass in furniture - Test methods
EN 16122:2012, Domestic and non-domestic storage furniture - Test methods for the determination of
strength, durability and stability
5
---------------------- Page: 7 ----------------------
oSIST prEN 16121:2021
prEN 16121:2021 (E)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1
accessible parts
parts to which access can easily be gained by the user when in its intended configuration of use and for
which the probability of unintentional user contact is high, including any parts that are less than 1000
mm above any surface on which a child could stand, but with the exception of doors, flaps and extension
elements including their hardware
Note 1 to entry: This includes, but is not limited to:
— the exposed edges and corners of storage units to which the user has access when the doors, drawers
and extension elements are closed,
— the corners and edges of handles.
3.2
parts accessible during setting up and folding
parts to which access can only be gained when setting up and folding the furniture
Note 1 to entry: For the definition of shear and squeeze points for furniture intended for use in schools and
kindergartens see B.2.1.1.
3.3
unit
complete item of furniture including the structure and all components such as drawers, doors and other
storage features
3.4
total mass
mass (kg) of the unit, or component plus the load defined in Table 2
3.5
clear height
unobstructed height above the top of the bottom surface
EXAMPLE The top of the extension element bottom and the lower edge of the extension element
above, or the structure of the unit (see Figure 1).
6
---------------------- Page: 8 ----------------------
oSIST prEN 16121:2021
prEN 16121:2021 (E)
Key
1 structure of the unit
2 clear height H
3 extension element
Figure 1 — Clear height
3.6
levelling device
adjustable device intended to keep the item of furniture perpendicular to the floor
EXAMPLE Adjustable feet or similar.
3.7
tray
storage element that is designed, under normal use, to be removed from the storage unit and used
independently
3.8
potential energy
Nm
2
multiplication of the total mass (kg) of the unit (or the part), gravity (m/s ) and the height (m) above the
floor to the centre of gravity
2
Note 1 to entry: For the purpose of this document gravity can be considered to be 10 m/s .
7
---------------------- Page: 9 ----------------------
oSIST prEN 16121:2021
prEN 16121:2021 (E)
4 Test sequence and tolerances
4.1 Individual units
When a single unit is supplied for test all the safety tests (5) shall be carried out on the same sample and
in the order in which they are listed in this document. Tests for strength and durability (6) may be carried
out on a second sample.
4.2 Range of units
For a range of units featuring similar construction and sharing hardware, or single units with features
utilizing identical hardware and fixings (e.g. a unit with different size drawers), selected tests shall be
carried out on the worst case units/components as detailed in Annex C.
The tests shall be carried out in the order in which they are listed in this document.
If one unit or component within a range of products does not satisfy the requirements of this document
then compliance for the full range cannot be claimed.
4.3 Tolerances
Unless otherwise stated, the following tolerances are applicable:
Forces: ± 5 % of the nominal force;
NOTE 1 Forces can be replaced by masses. The relationship 10N = 1 kg can be used.
Velocities: ± 5 % of the nominal velocity;
Masses: ± 1 % of the nominal mass;
Dimensions: ± 1 mm of the nominal dimension;
Angles: ± 2° of the nominal angle.
NOTE 2 For the purposes of uncertainty measurement, test results are not considered to be adversely affected
when the above tolerances are met.
5 Safety requirements
5.1 Principles of safety requirements
5.1.1 General
Safety requirements are based upon the knowledge that storage furniture and its parts are likely to cause
injury only when they are heavy and fall through a significant distance. This is possible if floor standing
units overbalance, wall or screen mounted units become detached, or heavy parts become detached from
units.
Therefore, the tests contained in Table 4 are only considered to affect safety when:
— The height of the centre of gravity of the unit, or any part, is > 650 mm above the floor and the total
mass is > 10kg,
or
— When the potential energy (3.8) of the unit, or any part, is > 65 Nm and the height of the centre of
gravity of the unit, or any part, is ≤ 650 mm.
8
---------------------- Page: 10 ----------------------
oSIST prEN 16121:2021
prEN 16121:2021 (E)
5.1.2 Determination of centre of gravity
The centre of gravity of a component or unit shall be taken as the geometric centre of that unit, except in
the case of extension elements, where the geometric centre of the usable volume shall be used.
The height of the centre of gravity above the floor shall be measured for storage furniture or their
components when installed according to the manufacturer’s instructions. Levelling devices shall be set
at their middle position.
Height adjustable components shall be placed in their highest position.
All wall or top hanging units, or components thereof, are considered to have their centre of gravity more
than 650 mm above the floor.
5.1.3 Determination of total mass
The total mass is the mass of the component or unit plus the mass supported by it.
Unless the component is conspicuously and durably marked by the manufacturer with a maximum load,
the mass of the contents shall be determined according to Table 1, which specifies mass per unit area for
shelves and the mass per unit volume for extension elements, baskets and trays etc.
The volume of fixed baskets and trays shall be taken as the volume contained below their top edge.
The volume of extension elements shall be taken as the area of its bottom multiplied by the clear height
(3.5).
Table 1 — Load to determine total mass and load applied to all components other than those
undergoing test, excluding stability tests
Part Unit Load
Non-domestic Office
2
Horizontal surfaces, tops, shelves, door baskets kg/dm 1,5 1,5
etc.
3
Extension elements, trays and baskets kg/dm 0,2 0,5
Suspended pocket files a 4 4
kg/dm
Clothes rails kg/dm 4 5
a
measured perpendicular to the plane of the pocket files
5.2 General safety requirements
The storage units shall be so designed as to minimize the risk of injury to the user.
All parts of the storage unit with which the user comes into contact, during intended use, shall be so
designed that physical injury and damage are avoided. This requirement is met when:
1. the accessible parts are rounded or chamfered, and all other edges accessible during intended use
are free from burrs and sharp edges,
2. feet of tubular components shall be capped or otherwise closed.
Movable and adjustable parts shall be designed so that injuries and inadvertent operation are avoided.
It shall not be possible for any load bearing part of the storage unit to come loose unintentionally.
All parts which are lubricated to assist sliding shall be designed to protect users from lubricant stains
when in normal use.
9
---------------------- Page: 11 ----------------------
oSIST prEN 16121:2021
prEN 16121:2021 (E)
If it can cause injury, all roll fronts and doors sliding vertically including those constructed from hinged
elements shall not move by themselves from any position higher than 200 mm measured from the closed
position.
In order to avoid pinching points for feet, the safe height for vertically moving units shall be at least
100 mm from the floor.
Subject to the conditions contained within the general safety principles (5.1.1), all extension elements
and trays shall not become detached from the unit when subjected to one horizontal pull force of 200 N
applied to the handle of the loaded extension element/tray. The extension element/tray shall be loaded
in accordance with Table 1, unless the component is conspicuously and durably marked by the
manufacturer with a maximum load. In this case the component shall be loaded with the stated maximum
load.
5.3 Holes in tubular/rigid components
There shall be no holes in the ends of tubular components or holes in rigid components in accessible parts
between 8 mm and 12 mm, unless the depth of penetration is less than 10 mm. This requirement is
fulfilled if there is no hazard present when tested in accordance with A.1.
5.4 Shear and compression points
5.4.1 Shear and compression points when setting up and folding
Unless 5.4.2 or 5.4.3 are applicable, shear and compression points that are created only during setting up
and folding are acceptable, because the user can be assumed to be in control of his/her movements and
to be able to cease applying the force immediately upon experiencing pain.
The edges of parts moving relative to each other and creating shear and compression points shall be as
specified in 5.2.
The shear and compression points for furniture intended for use in schools and kindergartens are
contained in Annex B.
5.4.2 Shear and compression points under influence of powered mechanisms
With the exception of operation of doors, flaps and extension elements, there shall be no areas where the
distance between two accessible parts moving relative to each other can be less than 25 mm, and more
than 8 mm in any position during movement that could present a risk of injury to the user, created by
parts of the furniture operated by powered mechanisms, e.g. electrical motors, mechanical springs and
gas lifts.
This requirement is fulfilled if there is no hazard present when tested in accordance with A.2.1.
The shear and compression points for furniture intended for use in schools and kindergartens are
contained in Annex B.
5.4.3 Shear and compression points during use
With the exception of operation of doors, flaps and extension elements including their hardware, there
shall be no areas where the distance between two accessible parts moving relative to each other can be
less than 18 mm, and more than 8 mm in any position that could present a risk of injury to the user,
created by loads applied during normal use.
The loads defined within Table 2 are considered representative of normal use.
This requirement is fulfilled if there is no hazard present when tested in accordance with A.2.2.
The shear and compression points for furniture intended for use in schools and kindergartens are
contained in Annex B.
10
---------------------- Page: 12 ----------------------
oSIST prEN 16121:2021
prEN 16121:2021 (E)
5.5 Hinged horizontal lids
Horizontal lids that are 1 000 mm or less from the floor and weigh 0,25 kg or more, that are hinged, shall
be provided with lid-support mechanisms to prevent sudden collapse or dropping of the lid. The lid-
support mechanism shall support the lid so that at no position in the arc of travel of the lid from within
50 mm of the fully closed position through an arc not to exceed 60° from the fully closed position shall it
drop more than 12 mm under the influence of its own mass, except in the last 50 mm of travel. The test
shall be carried out in accordance with EN 71-1:2014+A1:2018, 8.31.2.
The lid-support mechanism shall confirm to this requirement before and after being tested to the
durability of flaps test, as described in Table 5.
5.6 Vertical glass components
2
Any external, vertical glass component ≥ 0,1 m in area, where the smallest dimension is greater than or
equal to 200 mm and any part of which is less than 900 mm above the floor, shall not break or become
detached, when impacted once in accordance with EN 14072:2003, Clause 5 with a drop height of 70 mm.
The impact point shall be on the most adverse corner 100 mm from the edge of the glass.
This requirement is not applicable if either:
— the manufacturer, importer or retailer, provides verification that the glass fulfils the requirements in
EN 12150-1:2015+A1:2019, Clause 8, fragmentation test; or where the mode of breakage (β)
according to EN 12600, is Type B or Type C, or
— the glass has been tested in accordance with EN 12150-1:2015+A1:2019, 8.3 and 8.4 (fragmentation
test) with a minimum particle count of 40 particles in any 50 mm x 50 mm square, in derogation that
the test has been performed on one full size sample of the glass, as used in the product.
5.7 Stability
The requirements for stability only apply to units where the height to the top of the unit is 650 mm or
more above the floor level, and when the potential energy (3.8), exceeds the value 65.
Where specified the unit shall be loaded in accordance with the loads specified in Table 2. When the unit
or component is conspicuously and durably marked by the manufacturer with a maximum load, the unit
or component shall be loaded with the stated maximum load multiplied by 0,5, but the load shall not
exceed the value calculated using Table 2.
11
---------------------- Page: 13 ----------------------
oSIST prEN 16121:2021
prEN 16121:2021 (E)
Table 2 — Loads for stability testing
Component Load Load
Non-domestic a
Office
All horizontal storage areas, including shelves, bottoms,
2 2
0,325 kg/dm 1,5 kg/dm
tops and flaps
Extension elements, trays and baskets with clear height
3 3
0,2 kg/dm 0,5 kg/dm
(3.5), H, ≤ 1 dm:
(0,2667 – 0,0667H)
Extension elements, trays and baskets with clear height
3
3
kg/dm
0,5 kg/dm
(3.5), H, between 1 dm and 2,5 dm:
(H in dm)
Extension elements, trays and baskets with clear height
3 3
0,1 kg/dm 0,5 kg/dm
(3.5), H, ≥ 2,5 dm:
Hanging rails 2 kg/dm 5 kg/dm
Suspended filing pockets 1,25 kg/dm 4 kg/dm
a
When the unit or component is conspicuously and durably marked by the manufacturer with a maximum load,
the unit or component shall be loaded with the stated maximum load.
Storage units shall be tested for stability according to Table 3, and following the order listed in Table 3.
The stability requirements are fulfilled when tested in accordance with Table 3, the storage unit does not
overturn. If the storage unit is prevented from overturning by an open extension element, open door or
open flap the stability requirements are not fulfilled.
12
---------------------- Page: 14 ----------------------
oSIST prEN 16121:2021
prEN 16121:2021 (E)
Table 3 — Stability tests
Test No Test Reference Loading Force
5.6.1 Doors, extension elements and EN 16122:2012, Vertical force, 750
flaps closed, all storage units 11.2.1 N;
unloaded - Units that are, or can
be, adjusted to a height of 1
000 mm or less
5.6.2 Doors, extension elements and EN 16122:2012, Vertical force, 350
flaps closed, all storage units 11.2.2 N;
50
unloaded - Units that are, or can
Outward
be, adjusted to a height of more
force, N;
than 1 000 mm
5.6.3 All storage areas unloaded and all EN 16122:2012, - -
doors, extension elements and 11.4.1
flaps open
5.6.4 All storage areas unloaded with EN 16122:2012, Vertical force, 100
overturning load 11.4.2 N
5.6.5 All storage areas loaded with EN 16122:2012, Vertical force, 20 % of
overturning load 11.4.3 N total mass
(3.4) of
the unit
but not
greater
than
300 N
5.6.6 Doors, extension elements and EN 16122:2012, Outward 100
flaps closed and locked 11.5 force, N;
5.6.7 Dynamic stability test for units EN 16122:2012, - -
a 11.6
with castors
a
The test shall be carried out in accordance with EN 16122:2012, 11.6 except that the stops shall be
...
Questions, Comments and Discussion