SIST EN 300 019-2-7 V3.0.0:2006
(Main)Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-7: Specification of environmental tests; Portable and non-stationary use
- Abstract
The present document specifies test methods and severities for the verification of the required resistibility of telecommunication equipment according to the relevant environmental class. The tests defined in the present document apply to portable and non-stationary use of equipment, covering the environments stated in EN 300 019-1-7 [1].
- Status
- Published
- Publication Date
- 31-Jan-2006
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Feb-2006
- Due Date
- 01-Feb-2006
- Completion Date
- 01-Feb-2006
SIST EN 300 019-2-7 V3.0.0:2006 is the Slovenian adoption of ETSI EN 300 019-2-7 V3.0.0 for Environmental Engineering (EE) of telecommunications equipment. It specifies environmental test methods and severities for verifying the resistibility of telecom equipment used in portable and non-stationary conditions, so designers, test labs and quality teams can match tests to the intended use environment.
What does SIST EN 300 019-2-7 V3.0.0:2006 specify?
SIST EN 300 019-2-7 V3.0.0:2006 specifies the environmental tests used to verify telecom equipment against the environmental classes for portable and non-stationary use. The scope is limited to the environments covered by EN 300 019-1-7 [1].
The document is organized into:
- Clause 1 - Scope
- Clause 2 - References
- Clause 3 - Environmental test specifications
- Clause 4 - Notes to tables
- Annex A - Bibliography
Clause 3 gives the test specifications for the four use environments T 7.1, T 7.2, T 7.3 and T 7.3E, while clause 4 explains how to read the tables and when some tests are or are not recommended. That structure matters in practice because the environmental class and the intended use location determine which test set to apply.
What are the key requirements of SIST EN 300 019-2-7 V3.0.0:2006?
SIST EN 300 019-2-7 V3.0.0:2006 assumes the equipment under test is operational during the test conditions unless stated otherwise, and the product specification must define the required performance before, during and after testing. In practice, the test plan has to say what is measured and what pass/fail criteria apply.
How does clause 3 define the test setup?
Clause 3 says input and load conditions shall be chosen to obtain full utilization of the equipment under test, and heat dissipation shall be maximized except for the steady-state low-temperature test. That means the equipment should be stressed in a realistic worst-case operating state, not a lightly loaded one.
What do the environmental classes cover?
- T 7.1, in clause 3.1 and table 1, applies to permanently temperature-controlled enclosed locations. It focuses on indoor use and direct transfer between such locations.
- T 7.2, in clause 3.2 and table 2, applies to enclosed locations without temperature or humidity control, although heating may be used to avoid low temperatures. This is the class to use when the environment is less controlled but still not exposed to full outdoor weather.
- T 7.3, in clause 3.3 and table 3, applies to partly weatherprotected and non-weatherprotected locations, including transfer between them. This matters for equipment that can be used outdoors or moved in and out of protected areas.
- T 7.3E, in clause 3.4 and table 4, extends the non-weatherprotected case to a broader range of construction and colder exposure. It is the stricter choice when the equipment may face colder outdoor conditions.
Each of these tables combines climatic, chemical, mechanical and biological exposure categories, but only where the standard recommends a test method for that condition.
Which mechanical tests are part of the standard?
Tables 5 and 6 cover mechanical tests for T 7.1 to T 7.3E and distinguish portable IEC 721 classes 7M2 and 7M3. They include vibration, random vibration, shocks, bumps, free fall, and drop and topple.
This is important because portable equipment is exposed to handling, transport and movement as well as climate. Clause 4 notes that random vibration is considered more realistic than sinusoidal vibration, and that free fall is supplemented by drop and topple because the exact attitude of falling equipment cannot be fixed.
What do the notes change in practice?
Clause 4 explains how to interpret the table entries:
- the higher dry-heat value accounts for direct solar heat trap effects
- temperature change tests are used to check design tolerancing
- the rain test is a hand-held shower-type test
- chemically active substances and mechanically active substances are mainly design and material-selection considerations
- flora, fauna, dust and sand are also treated as design conditions in some cases rather than test conditions
That means the standard is not only a list of chamber settings - it also tells users where to test, where to monitor function, and where to make design decisions instead of running a separate laboratory test.
What terms does SIST EN 300 019-2-7 V3.0.0:2006 define?
Portable and non-stationary use means telecom equipment intended to be moved, transferred or used in changing locations rather than fixed installation.
Temperature-controlled locations are enclosed places where temperature is controlled permanently, while humidity is usually not controlled.
Partly temperature-controlled locations are enclosed places without full temperature or humidity control, but where heating may be used to avoid low temperatures.
Partly weatherprotected and non-weatherprotected locations are places with limited or no protection from weather, including transfer between those locations.
Acceleration Spectral Density (ASD) is the vibration measure used in the random vibration tests in tables 5 and 6.
Characteristic severity is the environmental severity level used as the basis for the test recommendations and notes.
Resistibility is the ability of telecommunications equipment to withstand the environmental conditions defined for its class.
Who uses SIST EN 300 019-2-7 V3.0.0:2006?
SIST EN 300 019-2-7 V3.0.0:2006 is used by equipment designers, environmental test engineers, verification laboratories, quality managers and procurement teams working with telecommunications equipment. They use it to choose the correct environmental class, set up qualification tests, write product specifications and check whether portable or transportable equipment is fit for the intended locations.
It is most relevant for telecom terminal equipment and related products that are carried, moved or used outside fixed, fully controlled installations.
What changed in SIST EN 300 019-2-7 V3.0.0:2006 from the previous edition?
The document history shows earlier publication as ETS 300 019-2-5, then V2.1.2, then V3.0.0. The history also records adoption through the one-step approval procedure before publication in December 2002.
Which standards are used with SIST EN 300 019-2-7 V3.0.0:2006?
- EN 300 019-1-7 [1] - gives the environmental conditions and classes that this part tests against.
- IEC 60068-2 [2] - supplies the environmental test methods cited in the tables, such as cold, dry heat, damp heat, vibration, shock and bump.
- ETS 300 019-2-0 [3] - provides the general overview of part 2.
- ISO 4180-2 [4] - is used in the free-fall test notes for selecting fall heights by mass.
What does the SIST EN 300 019-2-7 V3.0.0:2006 document contain?
SIST EN 300 019-2-7 V3.0.0:2006 contains four environmental test specification tables for T 7.1, T 7.2, T 7.3 and T 7.3E, plus two mechanical test tables for portable classes 7M2 and 7M3. It also contains notes that explain why certain tests are recommended, why some are not recommended, and how to apply the severities.
The document uses those tables to support design verification, environmental qualification and test planning for telecom equipment intended for portable and non-stationary use. Annex A provides the bibliography used by the standard.
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.
IMP NDT d.o.o.
Non-destructive testing services. Radiography, ultrasonic, magnetic particle, penetrant, visual inspection.
Inštitut za kovinske materiale in tehnologije
Institute of Metals and Technology. Materials testing, metallurgical analysis, NDT.
Sponsored listings
Frequently Asked Questions
SIST EN 300 019-2-7 V3.0.0:2006 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-7: Specification of environmental tests; Portable and non-stationary use". This standard covers: The present document specifies test methods and severities for the verification of the required resistibility of telecommunication equipment according to the relevant environmental class. The tests defined in the present document apply to portable and non-stationary use of equipment, covering the environments stated in EN 300 019-1-7 [1].
The present document specifies test methods and severities for the verification of the required resistibility of telecommunication equipment according to the relevant environmental class. The tests defined in the present document apply to portable and non-stationary use of equipment, covering the environments stated in EN 300 019-1-7 [1].
SIST EN 300 019-2-7 V3.0.0:2006 is classified under the following ICS (International Classification for Standards) categories: 19.040 - Environmental testing; 33.050.01 - Telecommunication terminal equipment in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 300 019-2-7 V3.0.0:2006 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-februar-2006
Okoljski inženiring (EE) – Okoljski pogoji in preskusi vplivov okolja na
telekomunikacijsko opremo – 2-7. del: Specifikacija preskusov vplivov okolja –
Prenosna in nefiksna uporaba
Environmental Engineering (EE); Environmental conditions and environmental tests for
telecommunications equipment; Part 2-7: Specification of environmental tests; Portable
and non-stationary use
Ta slovenski standard je istoveten z: EN 300 019-2-7 Version 3.0.0
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
European Standard (Telecommunications series)
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 2-7: Specification of environmental tests;
Portable and non-stationary use
2 ETSI EN 300 019-2-7 V3.0.0 (2002-12)
Reference
REN/EE-01034-2-7
Keywords
environment, mobile, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, send your comment to:
editor@etsi.org
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2002.
All rights reserved.
TM TM TM
DECT , PLUGTESTS and UMTS are Trade Marks of ETSI registered for the benefit of its Members.
TM
TIPHON and the TIPHON logo are Trade Marks currently being registered by ETSI for the benefit of its Members.
TM
3GPP is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners.
ETSI
3 ETSI EN 300 019-2-7 V3.0.0 (2002-12)
Contents
Intellectual Property Rights.3
Foreword.3
1 Scope.3
2 References.3
3 Environmental test specifications.3
3.1 Specification T 7.1: Temperature-controlled locations .3
3.2 Specification T 7.2: Partly temperature-controlled locations .3
3.3 Specification T 7.3: Partly weatherprotected and non-weatherprotected locations.3
3.4 Specification T 7.3E: Partly weatherprotected and non-weatherprotected locations - extended.3
4 Notes to tables .3
4.1 General note.3
4.2 Notes to tables 1 to 6 .3
Annex A (informative): Bibliography.3
History .3
ETSI
4 ETSI EN 300 019-2-7 V3.0.0 (2002-12)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://webapp.etsi.org/IPR/home.asp).
All published ETSI deliverables shall include information which directs the reader to the above source of information.
Foreword
This European Standard (Telecommunications series) has been produced by ETSI Technical Committee Environmental
Engineering (EE).
The present document is part 2, sub-part 7 of a multi-part deliverable covering environmental conditions and
environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions";
Part 2: "Specification of environmental tests";
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations".
Part 1 specifies different standardized environmental classes covering climatic and biological conditions, chemically
and mechanically active substances and mechanical conditions during storage, transportation and in use.
Part 2 specifies the recommended test severities and test methods for the different environmental classes.
Part 2-0 forms a general overview of part 2. The present document deals with portable and non-stationary use.
National transposition dates
Date of adoption of this EN: 29 November 2002
Date of latest announcement of this EN (doa): 28 February 2003
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 31 August 2003
Date of withdrawal of any conflicting National Standard (dow): 31 August 2003
ETSI
5 ETSI EN 300 019-2-7 V3.0.0 (2002-12)
1 Scope
The present document specifies test methods and severities for the verification of the required resistibility of
telecommunication equipment according to the relevant environmental class.
The tests defined in the present document apply to portable and non-stationary use of equipment, covering the
environments stated in EN 300 019-1-7 [1].
2 References
The following documents contain provisions which, through reference in this text, constitute provisions of the present
document.
• References are either specific (identified by date of publication and/or edition number or version number) or
non-specific.
• For a specific reference, subsequent revisions do not apply.
• For a non-specific reference, the latest version applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
[1] ETSI EN 300 019-1-7: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-7: Classification of environmental
conditions; Portable and non-stationary use".
[2] IEC 60068-2 (all parts): "Environmental testing - Part 2: Tests".
[3] ETSI ETS 300 019-2-0: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 2-0: Specification of environmental
tests; Introduction".
[4] ISO 4180-2 (1980): "Complete, filled transport packages - General rules for the compilation of
performance test schedules - Part 2: Quantitive data".
3 Environmental test specifications
The detailed descriptions of the environmental conditions are given in clauses 4 and 5 of EN 300 019-1-7 [1].
ETS 300 019-2-0 [3] forms a general overview of part 2 of the present document.
The equipment under test is assumed to be in its operational state throughout the test conditions described in this part
unless otherwise stated. The required performance before, during and after the test needs to be specified in the product
specification. Input and load conditions of the equipment shall be chosen to obtain full utilization of the equipment
under test. The heat dissipation shall be maximized, except for the steady state, low temperature test, where it shall be
minimized.
ETSI
6 ETSI EN 300 019-2-7 V3.0.0 (2002-12)
3.1 Specification T 7.1: Temperature-controlled locations
This specification applies to use at, and direct transfer between, permanently temperature-controlled enclosed locations where humidity is usually not controlled. See tables 1, 5
and 6.
Table 1: Test specification T 7.1: Temperature-controlled locations - climatic tests
Environmental parameter Environmental Environmental test specification T7.1: Portable,
Class 7.1 Temperature - controlled location
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
low (°C) +5 +5 16 h Ab/Ad: Cold 1
IEC 60068-2-1 [2]
Air temperature high (°C) +40 +40 or +50 16 h Bb/Bd: Dry heat 2
IEC 60068-2-2 [2]
change (°C) +5/+25 +5/+25 3 cycles Na: Change of 3
IEC 60068-2-14 [2]
t = 3 h temperature
low (%) 5 none 4
relative high (%) 85 93 96 h Cb: Damp heat 5
IEC 60068-2-56 [2]
(°C) +30 +30 steady state
Humidity condensation (%) yes 90-100 2 cycles Db: Damp heat 6
IEC 60068-2-30 [2]
(°C) +30 Cyclic, variant 2
absolute 1 none 4
low (g/m )
25 none 7
high (g/m )
pressure low (kPa) 70 none 8
Air high (kPa) 106 none 8
speed (m/s) 5,0 none 4
intensity (mm/min) no
rain
Water low temperature (°C) no
other sources no
icing & frosting no
Radiation solar 700 none 11
(W/m )
heat 600 none 11
(W/m )
sulphur 0,3/1,0 none 12
SO (mg/m )
0,1/0,5 none 12
HS (mg/m )
Chemically salts Sea and road salt mist none 12
active
chlorine 0,1/0,3 none 12
Cl (mg/m )
substances
0,1/0,5 none 12
HCl (mg/m )
nitrogen 0,5/1,0 none 12
NO (mg/m )
x
1,0/3,0 none 12
NH (mg/m )
hydrogen fluoride 0,01/0,03 none 12
HF (mg/m )
ozone 0,05/0,1 none 12
O (mg/m )
ETSI
7 ETSI EN 300 019-2-7 V3.0.0 (2002-12)
Environmental parameter Environmental Environmental test specification T7.1: Portable,
Class 7.1 Temperature - controlled location
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
Mechanically
dust 1,5 none 13
sedimentation (mg/(m h))
active
0,2 none 13
suspension (mg/m )
substances
sand 30 none 13
(mg/m )
Flora and micro organisms no
Fauna
rodents, insects no
no: This condition does not occur in this class.
none: Verification is required only in special cases.
NOTES: Number of note, see clause 3.4.
3.2 Specification T 7.2: Partly temperature-controlled locations
This specification applies to use at and direct transfer between, enclosed locations having neither temperature nor humidity control but where heating may be used to avoid low
temperatures. Building construction avoids extremely high temperatures. See tables 2, 5 and 6.
Table 2: Test specification T 7.2: Partly temperature-controlled locations - climatic tests
Environmental parameter Environmental Environmental test specification T7.2: Portable,
Class 7.2 Partly temperature- controlled locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
low (°C) -5 -5 16 h Ab/Ad: Cold 1
IEC 60068-2-1 [2]
Air temperature high (°C) +45 +45 or +55 16 h Bb/Bd: Dry heat 2
IEC 60068-2-2 [2]
change (°C) -5/+25 -5/+25 3 cycles Na: Change of 3
IEC 60068-2-14 [2]
t = 3 h temperature
low (%) 5 none 4
relative high (%) 95 93 96 h Cb: Damp heat 5
IEC 60068-2-56 [2]
(°C) +30 steady state
Humidity condensation (%) yes 90-100 2 cycles Db: Damp heat 6
IEC 60068-2-30 [2]
(°C) +30 Cyclic, variant 2
absolute 1 none 4
low (g/m )
29 none 7
high (g/m )
pressure low (kPa) 70 none 8
Air high (kPa) 106 none 8
speed (m/s) 5,0 none 4
intensity (mm/min) no
rain
Water low temperature (°C) no
other sources dripping water none 10
icing & frosting yes none 4
ETSI
8 ETSI EN 300 019-2-7 V3.0.0 (2002-12)
Environmental parameter Environmental Environmental test specification T7.2: Portable,
Class 7.2 Partly temperature- controlled locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
Radiation solar 700 none 11
(W/m )
heat 600 none 11
(W/m )
sulphur 0,3/1,0 none 12
SO (mg/m )
0,1/0,5 none 12
HS (mg/m )
Chemically salts sea and road salt mist none 12
active
chlorine 0,1/0,3 none 12
Cl (mg/m )
substances
0,1/0,5 none 12
HCl (mg/m )
nitrogen 0,5/1,0 none 12
NO (mg/m )
x
1,0/3,0 none 12
NH (mg/m )
hydrogen fluoride 0,01/0,03 none 12
HF (mg/m )
ozone 0,05/0,1 none 12
O (mg/m )
Mechanically dust 20 none 13
sedimentation (mg/(m h))
active 3
5,0 none 13
suspension (mg/m )
substances
sand 300 none 13
(mg/m )
Flora and micro organisms moulds, fungus, etc. none 14
Fauna
rodents, insects rodents, etc. none 14
no: This condition does not occur in this class.
none: Verification is required only in special cases.
NOTES: Number of note, see clause 3.4.
ETSI
9 ETSI EN 300 019-2-7 V3.0.0 (2002-12)
3.3 Specification T 7.3: Partly weatherprotected and non-weatherprotected locations
This specification applies to use at totally or partly weatherprotected locations of such construction that extremely low temperatures are avoided and to use at
non-weatherprotected locations and to transfe
...