SIGNIFICANCE AND USE
5.1 The presence and concentration of elements in lime and limestone is important in determining product quality and its suitability for various uses. This test method provides a means of measuring the major and trace element concentration in lime and limestone.
SCOPE
1.1 The following test method covers the use of inductively coupled plasma-atomic emission spectroscopy (ICP) and atomic absorption spectroscopy (AA) in the analysis of major and trace elements in limestone and lime (calcined limestone).
1.2 Table 1 lists some of the elements that can be analyzed by this test method and the preferred wavelengths. Also see U.S. EPA Methods 200.7 and 200.9.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard8 pagesEnglish language
- Standard8 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This procedure is suitable for manufacturing control and verifying that the product meets specifications. It provides rapid, multi-element determinations with sufficient accuracy to ensure product quality and minimize production delays. The analytical performance data included may be used as a benchmark to determine whether similar X-ray spectrometers provide equivalent precision and accuracy, or whether the performance of a particular X-ray spectrometer has changed.
SCOPE
1.1 This test method covers the X-ray emission spectrometric analysis of limestone, quicklime, hydrated lime, and hydraulic lime using wavelength dispersive instruments.
1.2 The values stated in SI units are to be regarded as the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 10.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
5.1 There are existing lime-based flue gas desulfurization units in operation that require a method to measure the oxides available for sulfur dioxide absorption. Dissolved magnesium oxide varies among limes depending on the limestone sources and calcination conditions.
SCOPE
1.1 This test method covers analysis of magnesian, dolomitic and high-calcium limes for total neutralizing capability and dissolved major oxides. Dissolved calcium and magnesium are the major species that neutralize acid under the conditions of the test.
1.2 The test conditions are chosen to measure the acid-neutralizing capacity of both calcium hydroxide and magnesium hydroxide contained in slaked lime. By controlling the neutralization pH at 6, magnesium hydroxide and magnesium oxide are titrated in addition to calcium hydroxide fraction.
1.3 This test method also determines the fraction of Mg ions present in the lime that will dissolve under lime flue gas desulfurization (FGD) conditions. Because the Mg2+ ion alters FGD performance, it is important to know its concentration.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Since all limes and waste acid solutions are different, this test method evaluates the relative quantity of a given lime needed for the neutralization of a specific quantity of acid.
4.2 Liming materials have a specific basicity factor or measure of alkalinity which can be used for comparing their relative neutralizing power. It avoids dependence on chemical analysis and is determined as grams of calcium oxide equivalents per kilogram of liming material.
4.3 Likewise, specific waste acids have an acid value that can be expressed as grams of hydrochloric acid equivalent per litre of acid waste. This value is related on a stoichiometric basis to lime neutralization requirements of a liquid acid waste.
SCOPE
1.1 This test method covers the testing of quicklime and hydrated lime for use in the treatment of waste acid solutions and includes the characterization of the liming material and of the acid waste.
Note 1: When agreed upon by the manufacturer and the purchaser, this method may be used directly to evaluate the lime requirement for a plant waste acid and in the preparation of the lime slurry; the pH, the time, temperature, and other conditions of treatment may be adjusted to conform to plant practice. Otherwise the test shall be performed as described in this method.
Note 2: Under some conditions of test the lime requirement may vary substantially from that indicated by ultimate chemical analysis or by the use of a determination of available alkalinity by titration to a stoichiometric end point.
1.2 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard3 pagesEnglish language
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
4.1 These test methods provide accurate and reliable analytical procedures to determine the chemical constituents of limestone, quicklime, and hydrated lime (see Note 1). The percentages of specific constituents which determine a material's quality or fitness for use are of significance depending upon the purpose or end use of the material. Results obtained may be used in relation to specification requirements.
4.2 Because quicklime and hydrated lime quickly absorb water and carbon dioxide from the air, precision and bias are extremely dependent upon precautions taken during sample preparation and analysis to minimize excessive exposure to ambient conditions.
Note 1: These test methods can be applied to other calcareous materials if provisions are made to compensate for known interferences.
SCOPE
1.1 These test methods cover the chemical analysis of high-calcium and dolomitic limestone, quicklime, and hydrated lime. These test methods are classified as either standard (preferred) or alternative (optional).
1.2 The standard test methods are those that employ classical gravimetric or volumetric analytical procedures and are typically those required for referee analyses where chemical specification requirements are an essential part of contractual agreement between buyer and seller.
1.3 Alternative or optional test methods are provided for those who wish to use procedures shorter or more convenient than the standard methods for the routine determinations of certain constituents. Optional test methods may sometimes be preferred to the standard test methods, but frequently the use of modern and expensive instrumentation is indicated which may not be accessible to everyone. Therefore, the use of these test methods must be left to the discretion of each laboratory.
1.4 The analytical procedures appear in the following order:
Section
Aluminum Oxide
15
Available Lime Index
28
Calcium and Magnesium Oxide:
Alternative EDTA Titration Method
31
Calcium Carbonate Equivalent
33
Calcium Oxide:
Gravimetric Method
16
Volumetric Method
17
Carbon Dioxide by Standard Method
22
Combined Oxides of Iron and Aluminum
12
Ferrous Iron
Appendix X5
Free Calcium Oxide
Appendix X6
Free Moisture in Hydrated Lime
21
Free Moisture in Limestone
20
Free Silica
29
Insoluble Matter Including Silicon Dioxide:
Standard Method
8
Optional Perchloric Acid Method
9
Insoluble Matter Other Than Silicon Dioxide
11
Loss on Ignition
19
Magnesium Oxide
18
Manganese:
Bismuthate Method
Appendix X4
Periodate (Photometric) Method
27
pH Determination of Alkaline Earth Solutions
34
Phosphorus:
Titrimetric Method
Appendix X3
Molybdovanadate Method
26
Silicon Dioxide
10
Strontium Oxide
Appendix X2
Sulfur Trioxide
23
Total Carbon:
Direct Combustion-Thermal Conductivity Cell
Method
32
Total Carbon and Sulfur:
Combustion/Infrared Detection Method
35
Total Iron:
Standard Method, Potassium Dichromate
Titration
13
Potassium Permanganate Titration Method
Appendix X1
Ortho-Phenanthroline, Photometric Method
14
Total Sulfur:
Sodium Carbonate Fusion
24
Combustion-Iodate Titration Method
25
Unhydrated Oxides
30
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
For specific precautionary statements, see 9.3, 10.2.1, 18.4.3, 31.6.4.2, X2.3.1, and X5.4.1.1.
1.6 This international standard was developed...
- Standard40 pagesEnglish language
SIGNIFICANCE AND USE
4.1 These test methods provide accurate and reliable analytical procedures to determine the chemical constituents of limestone, quicklime, and hydrated lime (see Note 1). The percentages of specific constituents which determine a material's quality or fitness for use are of significance depending upon the purpose or end use of the material. Results obtained may be used in relation to specification requirements.
4.2 Because quicklime and hydrated lime quickly absorb water and carbon dioxide from the air, precision and bias are extremely dependent upon precautions taken during sample preparation and analysis to minimize excessive exposure to ambient conditions.
Note 1: These test methods can be applied to other calcareous materials if provisions are made to compensate for known interferences.
SCOPE
1.1 These test methods cover the chemical analysis of high-calcium and dolomitic limestone, quicklime, and hydrated lime. These test methods are classified as either standard (preferred) or alternative (optional).
1.2 The standard test methods are those that employ classical gravimetric or volumetric analytical procedures and are typically those required for referee analyses where chemical specification requirements are an essential part of contractual agreement between buyer and seller.
1.3 Alternative or optional test methods are provided for those who wish to use procedures shorter or more convenient than the standard methods for the routine determinations of certain constituents. Optional test methods may sometimes be preferred to the standard test methods, but frequently the use of modern and expensive instrumentation is indicated which may not be accessible to everyone. Therefore, the use of these test methods must be left to the discretion of each laboratory.
1.4 The analytical procedures appear in the following order:
Section
Aluminum Oxide
15
Available Lime Index
28
Calcium and Magnesium Oxide:
Alternative EDTA Titration Method
31
Calcium Carbonate Equivalent
33
Calcium Oxide:
Gravimetric Method
16
Volumetric Method
17
Carbon Dioxide by Standard Method
22
Combined Oxides of Iron and Aluminum
12
Ferrous Iron
Appendix X5
Free Calcium Oxide
Appendix X6
Free Moisture in Hydrated Lime
21
Free Moisture in Limestone
20
Free Silica
29
Insoluble Matter Including Silicon Dioxide:
Standard Method
8
Optional Perchloric Acid Method
9
Insoluble Matter Other Than Silicon Dioxide
11
Loss on Ignition
19
Magnesium Oxide
18
Manganese:
Bismuthate Method
Appendix X4
Periodate (Photometric) Method
27
pH Determination of Alkaline Earth Solutions
34
Phosphorus:
Titrimetric Method
Appendix X3
Molybdovanadate Method
26
Silicon Dioxide
10
Strontium Oxide
Appendix X2
Sulfur Trioxide
23
Total Carbon:
Direct Combustion-Thermal Conductivity Cell
Method
32
Total Carbon and Sulfur:
Combustion/Infrared Detection Method
35
Total Iron:
Standard Method, Potassium Dichromate
Titration
13
Potassium Permanganate Titration Method
Appendix X1
Ortho-Phenanthroline, Photometric Method
14
Total Sulfur:
Sodium Carbonate Fusion
24
Combustion-Iodate Titration Method
25
Unhydrated Oxides
30
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see 9.3, 10.2.1, 18.4.3, 31.6.4.2, X2.3.1, and X5.4.1.1.
1.6 This international standard was developed in...
- Standard40 pagesEnglish language
- Standard40 pagesEnglish language
- Standard40 pagesEnglish language
SIGNIFICANCE AND USE
4.1 These test methods provide accurate and reliable analytical procedures to determine the chemical constituents of limestone, quicklime, and hydrated lime (see Note 1). The percentages of specific constituents which determine a material's quality or fitness for use are of significance depending upon the purpose or end use of the material. Results obtained may be used in relation to specification requirements.
4.2 Because quicklime and hydrated lime quickly absorb water and carbon dioxide from the air, precision and bias are extremely dependent upon precautions taken during sample preparation and analysis to minimize excessive exposure to ambient conditions.
Note 1: These test methods can be applied to other calcareous materials if provisions are made to compensate for known interferences.
SCOPE
1.1 These test methods cover the chemical analysis of high-calcium and dolomitic limestone, quicklime, and hydrated lime. These test methods are classified as either standard (preferred) or alternative (optional).
1.2 The standard test methods are those that employ classical gravimetric or volumetric analytical procedures and are typically those required for referee analyses where chemical specification requirements are an essential part of contractual agreement between buyer and seller.
1.3 Alternative or optional test methods are provided for those who wish to use procedures shorter or more convenient than the standard methods for the routine determinations of certain constituents. Optional test methods may sometimes be preferred to the standard test methods, but frequently the use of modern and expensive instrumentation is indicated which may not be accessible to everyone. Therefore, the use of these test methods must be left to the discretion of each laboratory.
1.4 The analytical procedures appear in the following order:
Section
Aluminum Oxide
15
Available Lime Index
28
Calcium and Magnesium Oxide:
Alternative EDTA Titration Method
31
Calcium Carbonate Equivalent
33
Calcium Oxide:
Gravimetric Method
16
Volumetric Method
17
Carbon Dioxide by Standard Method
22
Combined Oxides of Iron and Aluminum
12
Ferrous Iron
Appendix X5
Free Calcium Oxide
Appendix X6
Free Moisture in Hydrated Lime
21
Free Moisture in Limestone
20
Free Silica
29
Insoluble Matter Including Silicon Dioxide:
Standard Method
8
Optional Perchloric Acid Method
9
Insoluble Matter Other Than Silicon Dioxide
11
Loss on Ignition
19
Magnesium Oxide
18
Manganese:
Bismuthate Method
Appendix X4
Periodate (Photometric) Method
27
pH Determination of Alkaline Earth Solutions
34
Phosphorus:
Titrimetric Method
Appendix X3
Molybdovanadate Method
26
Silicon Dioxide
10
Strontium Oxide
Appendix X2
Sulfur Trioxide
23
Total Carbon:
Direct Combustion-Thermal Conductivity Cell
Method
32
Total Carbon and Sulfur:
Combustion/Infrared Detection Method
35
Total Iron:
Standard Method, Potassium Dichromate
Titration
13
Potassium Permanganate Titration Method
Appendix X1
Ortho-Phenanthroline, Photometric Method
14
Total Sulfur:
Sodium Carbonate Fusion
24
Combustion-Iodate Titration Method
25
Unhydrated Oxides
30
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see 9.3, 10.2.1, 18.4.3, 31.6.4.2, X2.3.1, and X5.4.1.1.
1.6 This international standard was developed in...
- Standard39 pagesEnglish language
- Standard39 pagesEnglish language
SIGNIFICANCE AND USE
5.1 There are existing lime-based flue gas desulfurization units in operation that require a method to measure the oxides available for sulfur dioxide absorption. Dissolved magnesium oxide varies among limes depending on the limestone sources and calcination conditions.
SCOPE
1.1 This test method covers analysis of magnesian, dolomitic and high-calcium limes for total neutralizing capability and dissolved major oxides. Dissolved calcium and magnesium are the major species that neutralize acid under the conditions of the test.
1.2 The test conditions are chosen to measure the acid-neutralizing capacity of both calcium hydroxide and magnesium hydroxide contained in slaked lime. By controlling the neutralization pH at 6, magnesium hydroxide and magnesium oxide are titrated in addition to calcium hydroxide fraction.
1.3 This test method also determines the fraction of Mg ions present in the lime that will dissolve under lime flue gas desulfurization (FGD) conditions. Because the Mg2+ ion alters FGD performance, it is important to know its concentration.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard3 pagesEnglish language
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
5.1 There are existing lime-based flue gas desulfurization units in operation that require a method to measure the oxides available for sulfur dioxide absorption. Dissolved magnesium oxide varies among limes depending on the limestone sources and calcination conditions.
SCOPE
1.1 This test method covers analysis of magnesian, dolomitic and high-calcium limes for total neutralizing capability and dissolved major oxides. Dissolved calcium and magnesium are the major species that neutralize acid under the conditions of the test.
1.2 The test conditions are chosen to measure the acid-neutralizing capacity of both calcium hydroxide and magnesium hydroxide contained in slaked lime. By controlling the neutralization pH at 6, magnesium hydroxide and magnesium oxide are titrated in addition to calcium hydroxide fraction.
1.3 This test method also determines the fraction of Mg ions present in the lime that will dissolve under lime flue gas desulfurization (FGD) conditions. Because the Mg++ ion alters FGD performance, it is important to know its concentration.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard3 pagesEnglish language
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The presence and concentration of elements in lime and limestone is important in determining product quality and its suitability for various uses. This test method provides a means of measuring the major and trace element concentration in lime and limestone.
SCOPE
1.1 The following test method covers the use of inductively coupled plasma-atomic emission spectroscopy (ICP) and atomic absorption spectroscopy (AA) in the analysis of major and trace elements in limestone and lime (calcined limestone).
1.2 Table 1 lists some of the elements that can be analyzed by this test method and the preferred wavelengths. Also see U.S. EPA Methods 200.7 and 200.9.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard4 pagesEnglish language
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Since all limes and waste acid solutions are different, this test method evaluates the relative quantity of a given lime needed for the neutralization of a specific quantity of acid.
4.2 Liming materials have a specific basicity factor or measure of alkalinity which can be used for comparing their relative neutralizing power. It avoids dependence on chemical analysis and is determined as grams of calcium oxide equivalents per kilogram of liming material.
4.3 Likewise, specific waste acids have an acid value that can be expressed as grams of hydrochloric acid equivalent per litre of acid waste. This value is related on a stoichiometric basis to lime neutralization requirements of a liquid acid waste.
SCOPE
1.1 This test method covers the testing of quicklime and hydrated lime for use in the treatment of waste acid solutions and includes the characterization of the liming material and of the acid waste. Note 1—When agreed upon by the manufacturer and the purchaser, this method may be used directly to evaluate the lime requirement for a plant waste acid and in the preparation of the lime slurry; the pH, the time, temperature, and other conditions of treatment may be adjusted to conform to plant practice. Otherwise the test shall be performed as described in this method. Note 2—Under some conditions of test the lime requirement may vary substantially from that indicated by ultimate chemical analysis or by the use of a determination of available alkalinity by titration to a stoichiometric end point.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Since all limes and waste acid solutions are different, this test method evaluates the relative quantity of a given lime needed for the neutralization of a specific quantity of acid.
4.2 Liming materials have a specific basicity factor or measure of alkalinity which can be used for comparing their relative neutralizing power. It avoids dependence on chemical analysis and is determined as grams of calcium oxide equivalents per kilogram of liming material.
4.3 Likewise, specific waste acids have an acid value that can be expressed as grams of hydrochloric acid equivalent per litre of acid waste. This value is related on a stoichiometric basis to lime neutralization requirements of a liquid acid waste.
SCOPE
1.1 This test method covers the testing of quicklime and hydrated lime for use in the treatment of waste acid solutions and includes the characterization of the liming material and of the acid waste.
Note 1: When agreed upon by the manufacturer and the purchaser, this method may be used directly to evaluate the lime requirement for a plant waste acid and in the preparation of the lime slurry; the pH, the time, temperature, and other conditions of treatment may be adjusted to conform to plant practice. Otherwise the test shall be performed as described in this method.
Note 2: Under some conditions of test the lime requirement may vary substantially from that indicated by ultimate chemical analysis or by the use of a determination of available alkalinity by titration to a stoichiometric end point.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard3 pagesEnglish language
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This procedure is suitable for manufacturing control and verifying that the product meets specifications. It provides rapid, multi-element determinations with sufficient accuracy to ensure product quality and minimize production delays. The analytical performance data included may be used as a benchmark to determine whether similar X-ray spectrometers provide equivalent precision and accuracy, or whether the performance of a particular X-ray spectrometer has changed.
SCOPE
1.1 This test method covers the X-ray emission spectrometric analysis of limestone, quicklime, hydrated lime, and hydraulic lime using wavelength dispersive instruments.
1.2 The values stated in SI units are to be regarded as the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 10.
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
4.1 These test methods provide accurate and reliable analytical procedures to determine the chemical constituents of limestone, quicklime, and hydrated lime (See Note 1). The percentages of specific constituents which determine a material's quality or fitness for use are of significance depending upon the purpose or end use of the material. Results obtained may be used in relation to specification requirements.
4.2 Because quicklime and hydrated lime quickly absorb water and carbon dioxide from the air, precision and bias are extremely dependent upon precautions taken during sample preparation and analysis to minimize excessive exposure to ambient conditions.
Note 1: These test methods can be applied to other calcareous materials if provisions are made to compensate for known interferences.
SCOPE
1.1 These test methods cover the chemical analysis of high-calcium and dolomitic limestone, quicklime, and hydrated lime. These test methods are classified as either standard (preferred) or alternative (optional).
1.2 The standard test methods are those that employ classical gravimetric or volumetric analytical procedures and are typically those required for referee analyses where chemical specification requirements are an essential part of contractual agreement between buyer and seller.
1.3 Alternative or optional test methods are provided for those who wish to use procedures shorter or more convenient than the standard methods for the routine determinations of certain constituents. Optional test methods may sometimes be preferred to the standard test methods, but frequently the use of modern and expensive instrumentation is indicated which may not be accessible to everyone. Therefore, the use of these test methods must be left to the discretion of each laboratory.
1.4 The analytical procedures appear in the following order:
Section
Aluminum Oxide
15
Available Lime Index
28
Calcium and Magnesium Oxide:
Alternative EDTA Titration Method
31
Calcium Carbonate Equivalent
33
Calcium Oxide:
Gravimetric Method
16
Volumetric Method
17
Carbon Dioxide by Standard Method
22
Combined Oxides of Iron and Aluminum
12
Ferrous Iron
Appendix X5
Free Calcium Oxide
Appendix X6
Free Moisture in Hydrated Lime
21
Free Moisture in Limestone
20
Free Silica
29
Insoluble Matter Including Silicon Dioxide:
Standard Method
8
Optional Perchloric Acid Method
9
Insoluble Matter Other Than Silicon Dioxide
11
Loss on Ignition
19
Magnesium Oxide
18
Manganese:
Bismuthate Method
Appendix X4
Periodate (Photometric) Method
27
pH Determination of Alkaline Earth Solutions
34
Phosphorus:
Titrimetric Method
Appendix X3
Molybdovanadate Method
26
Silicon Dioxide
10
Strontium Oxide
Appendix X2
Sulfur Trioxide
23
Total Carbon:
Direct Combustion-Thermal Conductivity Cell Method
32
Total Carbon and Sulfur:
Combustion/Infrared Detection Method
35
Total Iron:
Standard Method, Potassium Dichromate Titration
13
Potassium Permanganate Titration Method
Appendix X1
Ortho-Phenanthroline, Photometric Method
14
Total Sulfur:
Sodium Carbonate Fusion
24
Combustion-Iodate Titration Method
25
Unhydrated Oxides
30
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see 9.3, 10.2.1, 18.4.3, 31.6.4.2, X2.3.1, and X5.4.1.1.
- Standard38 pagesEnglish language
- Standard38 pagesEnglish language
SIGNIFICANCE AND USE
These test methods provide accurate and reliable analytical procedures to determine the chemical constituents of limestone, quicklime, and hydrated lime (See Note 1). The percentages of specific constituents which determine a material's quality or fitness for use are of significance depending upon the purpose or end use of the material. Results obtained may be used in relation to specification requirements.
Because quicklime and hydrated lime quickly absorb water and carbon dioxide from the air, precision and bias are extremely dependent upon precautions taken during sample preparation and analysis to minimize excessive exposure to ambient conditions.
Note 1—These test methods can be applied to other calcareous materials if provisions are made to compensate for known interferences.
SCOPE
1.1 These test methods cover the chemical analysis of high-calcium and dolomitic limestone, quicklime, and hydrated lime. These test methods are classified as either standard (preferred) or alternative (optional).
1.2 The standard test methods are those that employ classical gravimetric or volumetric analytical procedures and are typically those required for referee analyses where chemical specification requirements are an essential part of contractual agreement between buyer and seller.
1.3 Alternative or optional test methods are provided for those who wish to use procedures shorter or more convenient than the standard methods for the routine determinations of certain constituents. Optional test methods may sometimes be preferred to the standard test methods, but frequently the use of modern and expensive instrumentation is indicated which may not be accessible to everyone. Therefore, the use of these test methods must be left to the discretion of each laboratory.
1.4 The analytical procedures appear in the following order:
Section Aluminum Oxide 15 Available Lime Index 28 Calcium and Magnesium Oxide: Alternative EDTA Titration Method 31 Calcium Carbonate Equivalent 33 Calcium Oxide: Gravimetric Method 16 Volumetric Method 17 Carbon Dioxide by Standard Method 22 Combined Oxides of Iron and Aluminum 12 Ferrous Iron Appendix X5 Free Calcium Oxide Appendix X6 Free Moisture in Hydrated Lime 21 Free Moisture in Limestone 20 Free Silica 29 Insoluble Matter Including Silicon Dioxide: Standard Method 8 Optional Perchloric Acid Method 9 Insoluble Matter Other Than Silicon Dioxide 11 Loss on Ignition 19 Magnesium Oxide 18 Manganese: Bismuthate Method Appendix X4 Periodate (Photometric) Method 27 pH Determination of Alkaline Earth Solutions 34 Phosphorus: Titrimetric Method Appendix X3 Molybdovanadate Method 26 Silicon Dioxide 10 Strontium Oxide Appendix X2 Sulfur Trioxide 23 Total Carbon: Direct Combustion-Thermal Conductivity Cell Method32 Total Carbon and Sulfur: Combustion/Infrared Detection Method 35 Total Iron: Standard Method, Potassium Dichromate Titration 13 Potassium Permanganate Titration Method Appendix X1 Ortho-Phenanthroline, Photometric Method 14 Total Sulfur: Sodium Carbonate Fusion 24 Combustion-Iodate Titration Method 25 Unhydrated Oxides 30
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see 9.3, 10.2.1, 18.4.3, 31.6.4.2, X2.3.1, and X5.4.1.1.
- Standard37 pagesEnglish language
- Standard37 pagesEnglish language
SIGNIFICANCE AND USE
4.1 These test methods provide accurate and reliable analytical procedures to determine the chemical constituents of limestone, quicklime, and hydrated lime (See Note 1). The percentages of specific constituents which determine a material's quality or fitness for use are of significance depending upon the purpose or end use of the material. Results obtained may be used in relation to specification requirements.
4.2 Because quicklime and hydrated lime quickly absorb water and carbon dioxide from the air, precision and bias are extremely dependent upon precautions taken during sample preparation and analysis to minimize excessive exposure to ambient conditions.
Note 1: These test methods can be applied to other calcareous materials if provisions are made to compensate for known interferences.
SCOPE
1.1 These test methods cover the chemical analysis of high-calcium and dolomitic limestone, quicklime, and hydrated lime. These test methods are classified as either standard (preferred) or alternative (optional).
1.2 The standard test methods are those that employ classical gravimetric or volumetric analytical procedures and are typically those required for referee analyses where chemical specification requirements are an essential part of contractual agreement between buyer and seller.
1.3 Alternative or optional test methods are provided for those who wish to use procedures shorter or more convenient than the standard methods for the routine determinations of certain constituents. Optional test methods may sometimes be preferred to the standard test methods, but frequently the use of modern and expensive instrumentation is indicated which may not be accessible to everyone. Therefore, the use of these test methods must be left to the discretion of each laboratory.
1.4 The analytical procedures appear in the following order:
Section
Aluminum Oxide
15
Available Lime Index
28
Calcium and Magnesium Oxide:
Alternative EDTA Titration Method
31
Calcium Carbonate Equivalent
33
Calcium Oxide:
Gravimetric Method
16
Volumetric Method
17
Carbon Dioxide by Standard Method
22
Combined Oxides of Iron and Aluminum
12
Ferrous Iron
Appendix X5
Free Calcium Oxide
Appendix X6
Free Moisture in Hydrated Lime
21
Free Moisture in Limestone
20
Free Silica
29
Insoluble Matter Including Silicon Dioxide:
Standard Method
8
Optional Perchloric Acid Method
9
Insoluble Matter Other Than Silicon Dioxide
11
Loss on Ignition
19
Magnesium Oxide
18
Manganese:
Bismuthate Method
Appendix X4
Periodate (Photometric) Method
27
pH Determination of Alkaline Earth Solutions
34
Phosphorus:
Titrimetric Method
Appendix X3
Molybdovanadate Method
26
Silicon Dioxide
10
Strontium Oxide
Appendix X2
Sulfur Trioxide
23
Total Carbon:
Direct Combustion-Thermal Conductivity Cell Method
32
Total Carbon and Sulfur:
Combustion/Infrared Detection Method
35
Total Iron:
Standard Method, Potassium Dichromate Titration
13
Potassium Permanganate Titration Method
Appendix X1
Ortho-Phenanthroline, Photometric Method
14
Total Sulfur:
Sodium Carbonate Fusion
24
Combustion-Iodate Titration Method
25
Unhydrated Oxides
30
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see 9.3, 10.2.1, 18.4.3, 31.6.4.2, X2.3.1, and X5.4.1.1.
- Standard38 pagesEnglish language
- Standard38 pagesEnglish language
SIGNIFICANCE AND USE
The presence and concentration of elements in lime and limestone is important in determining product quality and its suitability for various uses. This test method provides a means of measuring the major and trace element concentration in lime and limestone.
SCOPE
1.1 The following test method covers the use of inductively coupled plasma-atomic emission spectroscopy (ICP) and atomic absorption spectroscopy (AA) in the analysis of major and trace elements in limestone and lime (calcined limestone).
1.2 Table 1 lists some of the elements that can be analyzed by this test method and the preferred wavelengths. Also see U.S. EPA Methods 200.7 and 200.9.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
TABLE 1 Elements and Some Suggested WavelengthsA Major ElementsICP Wavelength, nmAA Wavelength, nm Calcium317.933 (315.887)B422.7 Magnesium279.079 (285.213)285.2 Silicon251.611 (288.160)251.6 Aluminum308.215 (309.271)309.3 Iron259.940248.3 Manganese257.610279.5 Sodium588.995 (589.59)589.0 Potassium766.491766.5 Phosphorus214.914 (213.618)...C Strontium421.552460.7 Trace ElementsICP Wavelength, nmAA Wavelength, nm Antimony206.833217.6 Arsenic193.696193.7 Barium455.403 (493.409)553.6 Beryllium313.042234.9 Boron249.773249.8 Cadmium226.502 (228.80)228.8 Chromium267.716 (205.552)357.9 Cobalt228.616240.7 (242.5) Copper324.754324.8 Lead220.353217.0 (283.3) Molybdenum202.030 (203.844)313.3 Nickel231.604 (221.647)232.0 Selenium196.090196.0 Silver328.068328.1 Sulfur180.731 (180.669)...C Thallium190.864276.8 Tin189.989235.5 (286.3) Vanadium292.402318.4 Zinc213.856 (202.551)213.9
A The suggested wavelengths may vary for your particular instrument.
B Numbers in parentheses are alternate wavelengths.
C Not recommended or not used.
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
There are existing lime-based flue gas desulfurization units in operation that require a method to measure the oxides available for sulfur dioxide absorption. Dissolved magnesium oxide varies among limes depending on the limestone sources and calcination conditions.
SCOPE
1.1 This test method covers analysis of magnesian, dolomitic and high-calcium limes for total neutralizing capability and dissolved major oxides. Dissolved calcium and magnesium are the major species that neutralize acid under the conditions of the test.
1.2 The test conditions are chosen to measure the acid-neutralizing capacity of both calcium hydroxide and magnesium hydroxide contained in slaked lime. By controlling the neutralization pH at 6, magnesium hydroxide and magnesium oxide are titrated in addition to calcium hydroxide fraction.
1.3 This test method also determines the fraction of Mg ions present in the lime that will dissolve under lime flue gas desulfurization (FGD) conditions. Because the Mg++ ion alters FGD performance, it is important to know its concentration.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
Since all limes and waste acid solutions are different, this test method evaluates the relative quantity of a given lime needed for the neutralization of a specific quantity of acid.
Liming materials have a specific basicity factor or measure of alkalinity which can be used for comparing their relative neutralizing power. It avoids dependence on chemical analysis and is determined as grams of calcium oxide equivalents per kilogram of liming material.
Likewise, specific waste acids have an acid value that can be expressed as grams of hydrochloric acid equivalent per litre of acid waste. This value is related on a stoichiometric basis to lime neutralization requirements of a liquid acid waste.
SCOPE
1.1 This test method covers the testing of quicklime and hydrated lime for use in the treatment of waste acid solutions and includes the characterization of the liming material and of the acid waste. Note 1
When agreed upon by the manufacturer and the purchaser, this method may be used directly to evaluate the lime requirement for a plant waste acid and in the preparation of the lime slurry; the pH, the time, temperature, and other conditions of treatment may be adjusted to conform to plant practice. Otherwise the test shall be performed as described in this method. Note 2
Under some conditions of test the lime requirement may vary substantially from that indicated by ultimate chemical analysis or by the use of a determination of available alkalinity by titration to a stoichiometric end point.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
These test methods provide accurate and reliable analytical procedures to determine the chemical constituents of limestone, quicklime, and hydrated lime (See Note 1). The percentages of specific constituents which determine a material’quality or fitness for use are of significance depending upon the purpose or end use of the material. Results obtained may be used in relation to specification requirements.
Because quicklime and hydrated lime quickly absorb water and carbon dioxide from the air, precision and bias are extremely dependent upon precautions taken during sample preparation and analysis to minimize excessive exposure to ambient conditions.
Note 1—These test methods can be applied to other calcareous materials if provisions are made to compensate for known interferences.
SCOPE
1.1 These test methods cover the chemical analysis of high-calcium and dolomitic limestone, quicklime, and hydrated lime. These test methods are classified as either standard (preferred) or alternative (optional).
1.2 The standard test methods are those that employ classical gravimetric or volumetric analytical procedures and are typically those required for referee analyses where chemical specification requirements are an essential part of contractual agreement between buyer and seller.
1.3 Alternative or optional test methods are provided for those who wish to use procedures shorter or more convenient than the standard methods for the routine determinations of certain constituents. Optional test methods may sometimes be preferred to the standard test methods, but frequently the use of modern and expensive instrumentation is indicated which may not be accessible to everyone. Therefore, the use of these test methods must be left to the discretion of each laboratory.
1.4 The analytical procedures appear in the following order:
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see , , , , , and .
- Standard36 pagesEnglish language
SIGNIFICANCE AND USE
This procedure is suitable for manufacturing control and verifying that the product meets specifications. It provides rapid, multi-element determinations with sufficient accuracy to ensure product quality and minimize production delays. The analytical performance data included may be used as a benchmark to determine whether similar X-ray spectrometers provide equivalent precision and accuracy, or whether the performance of a particular X-ray spectrometer has changed.
SCOPE
1.1 This test method covers the X-ray emission spectrometric analysis of limestone, quicklime, hydrated lime, and hydraulic lime using wavelength dispersive instruments.
1.2 The values stated in SI units are to be regarded as the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section .
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
The presence and concentration of elements in lime and limestone is important in determining product quality and its suitability for various uses. This test method provides a means of measuring the major and trace element concentration in lime and limestone.
SCOPE
1.1 The following test method covers the use of inductively coupled plasma-atomic emission spectroscopy (ICP) and atomic absorption spectroscopy (AA) in the analysis of major and trace elements in limestone and lime (calcined limestone).
1.2 Table 1 lists some of the elements that can be analyzed by this test method and the preferred wavelengths. Also see U.S. EPA Method 200.7 and 200.9.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard4 pagesEnglish language
SCOPE
1.1 This test method covers analysis of magnesian, dolomitic and high-calcium limes for total neutralizing capability and dissolved major oxides. Dissolved calcium and magnesium are the major species that neutralize acid under the conditions of the test.
1.2 The test conditions are chosen to measure the acid-neutralizing capacity of both calcium hydroxide and magnesium hydroxide contained in slaked lime. By controlling the neutralization pH at 6, magnesium hydroxide and magnesium oxide are titrated in addition to calcium hydroxide fraction.
1.3 This test method also determines the fraction of Mg ions present in the lime that will dissolve under lime flue gas desulfurization (FGD) conditions. Because the Mg++ ion alters FGD performance, it is important to know its concentration.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
There are existing lime-based flue gas desulfurization units in operation that require a method to measure the oxides available for sulfur dioxide absorption. Dissolved magnesium oxide varies among limes depending on the limestone sources and calcination conditions.
SCOPE
1.1 This test method covers analysis of magnesian, dolomitic and high-calcium limes for total neutralizing capability and dissolved major oxides. Dissolved calcium and magnesium are the major species that neutralize acid under the conditions of the test.
1.2 The test conditions are chosen to measure the acid-neutralizing capacity of both calcium hydroxide and magnesium hydroxide contained in slaked lime. By controlling the neutralization pH at 6, magnesium hydroxide and magnesium oxide are titrated in addition to calcium hydroxide fraction.
1.3 This test method also determines the fraction of Mg ions present in the lime that will dissolve under lime flue gas desulfurization (FGD) conditions. Because the Mg++ ion alters FGD performance, it is important to know its concentration.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard3 pagesEnglish language
SCOPE
1.1 The following test method covers the use of inductively coupled plasma-atomic emission spectroscopy (ICP) and atomic absorption spectroscopy (AA) in the analysis of major and trace elements in limestone and lime (calcined limestone).
1.2 Table 1 lists some of the elements that can be analyzed by this test method and the preferred wavelengths. Also see U.S. EPA Method 200.7 and 200.9.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard4 pagesEnglish language
SCOPE
1.1 These test methods cover the chemical analysis of high-calcium and dolomitic limestone, quicklime, and hydrated lime. These test methods are classified as either standard (preferred) or alternative (optional).
1.2 The standard test methods are those that employ classical gravimetric or volumetric analytical procedures and are typically those required for referee analyses where chemical specification requirements are an essential part of contractual agreement between buyer and seller.
1.3 Alternative or optional test methods are provided for those who wish to use procedures shorter or more convenient than the standard methods for the routine determinations of certain constituents. Optional test methods may sometimes be preferred to the standard test methods, but frequently the use of modern and expensive instrumentation is indicated which may not be accessible to everyone. Therefore, the use of these test methods must be left to the discretion of each laboratory.
1.4 The analytical procedures appear in the following order: Section Aluminum Oxide 15 Available Lime Index 28 Calcium and Magnesium Oxide: Alternative EDTA Titration Method 31 Calcium Carbonate Equivalent 33 Calcium Oxide: Gravimetric Method 16 Volumetric Method 17 Carbon Dioxide by Standard Method 22 Combined Oxides of Iron and Aluminum 12 Ferrous Iron X5 Free Calcium Oxide X6 Free Moisture in Hydrated Lime 21 Free Moisture in Limestone 20 Free Silica 29 Insoluble Matter Including Silicon Dioxide: Standard Method 8 Optional Perchloric Acid Method 9 Insoluble Matter Other Than Silicon Dioxide 11 Loss on Ignition 19 Magnesium Oxide 18 Manganese: Bismuthate Method X4 Periodate (Photometric) Method 27 pH Determination of Alkaline Earth Solutions 34 1a Phosphorus: Titrimetric Method X3 Molybdovanadate Method 26 Silicon Dioxide 10 Strontium Oxide X2 Sulfur Trioxide 23 Total Carbon: Direct Combustion-Thermal Conductivity Cell Method 32 Total Iron: Standard Method, Potassium Dichromate Titration 13 Potassium Permanganate Titration Method X1 Ortho-Phenanthroline, Photometric Method 14 Total Sulfur: Sodium Carbonate Fusion 24 Combustion-Iodate Titration Method 25 Unhydrated Oxides 30
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Notes 11, 13, 27, 47, X2.1, and X5.1.
- Standard36 pagesEnglish language
SCOPE
1.1 This test method covers the X-ray emission spectrometric analysis of limestone, quicklime, hydrated lime, and hydraulic lime using wavelength dispersive instruments.
1.2 The values stated in SI units are to be regarded as the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 10.
- Standard6 pagesEnglish language
SCOPE
1.1 This test method covers the testing of quicklime and hydrated lime for use in the treatment of waste acid solutions and includes the characterization of the liming material and of the acid waste. Note 1-When agreed upon by the manufacturer and the purchaser, this method may be used directly to evaluate the lime requirement for a plant waste acid and in the preparation of the lime slurry; the pH, the time, temperature, and other conditions of treatment may be adjusted to conform to plant practice. Otherwise the test shall be performed as described in this method. Note 2-Under some conditions of test the lime requirement may vary substantially from that indicated by ultimate chemical analysis or by the use of a determination of available alkalinity by titration to a stoichiometric end point.
1.2 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard2 pagesEnglish language
SIGNIFICANCE AND USE
This practice is designed to present in a standardized format information on the variability of limestone or lime from a single source over a period of time. It can be applied to all materials covered in Test Methods C 25 and C 110, and Specification C 141.
SCOPE
1.1 This practice is intended for use in instances where the purchaser desires information on the uniformity of limestone or lime produced at a single source. It is intended that this test method normally be used for the predominant material manufactured at a plant. Guidelines for sampling, testing and presentation of results (Table 1) are given.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard2 pagesEnglish language
SCOPE
1.1 This practice is intended for use in instances where the purchaser desires information on the uniformity of limestone or lime produced at a single source. It is intended that this test method normally be used for the predominant material manufactured at a plant. Guidelines for sampling, testing and presentation of results (Table 1) are given.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard2 pagesEnglish language
Frequently Asked Questions
C07.05 is a Technical Committee within ASTM International. It is named "Chemical Tests". This committee has published 30 standards.
C07.05 develops ASTM standards in the area of Information technology. Currently, there are 30 published standards from this technical committee.
ASTM is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.
A Technical Committee (TC) in ASTM is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.