CEN/TC 72/WG 3 - Fire alarm devices
To prepare product standards for fire alarm sounders, voice alarm components and alarm devices other than audible for use with fire detection and fire alarm systems.
Fire alarm devices
To prepare product standards for fire alarm sounders, voice alarm components and alarm devices other than audible for use with fire detection and fire alarm systems.
General Information
This European Standard specifies the requirements, test methods and performance criteria for visual alarm devices in a fixed installation intended to signal a visual warning of a fire between the fire detection and fire alarm system and the occupants of a building. It is intended to cover only those devices which derive their operating power by means of a physical electrical connection to an external source such as a fire alarm system.
This European Standard specifies the evaluation of conformity and the marking of the visual alarm devices.
This European Standard applies to visual alarm devices that rely on software for their operation and to those that do not.
This European Standard applies only to pulsing or flashing visual alarm devices, for example xenon beacons or rotating beacons. Devices giving continuous light output are excluded from this European Standard.
This European Standard is not intended to cover visual indicators, for example those on detectors or on the control and indicating equipment.
- Standard66 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements, test methods and performance criteria for loudspeakers intended to broadcast a warning of fire between a fire detection and fire alarm system and the occupants of a building.
This European Standard specifies loudspeakers for two types of application environment: type A, generally for indoor use and type B, generally for outdoor use.
This European Standard does not cover loudspeakers for special applications, for example loudspeaker for use in hazardous applications, if such applications require additional or other requirements or tests than those given in this European Standard.
This European Standard is not intended to cover addressable loudspeakers, loudspeakers with active components.
Voice alarm sounders are covered in EN 54-3:2001.
- Standard58 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements, methods of test and performance criteria for voice alarm control and indicating equipment for use in fire detection and fire alarm systems installed in buildings, where the alarm signal is in the form of tone(s) or voice message(s), or both.
It also provides for the evaluation of conformity of the equipment to the requirements of this European Standard.
NOTE The overall requirements of a voice alarm system, especially concerning audibility and intelligibility, are not covered in this part of EN 54. The manufacturer should consider requirements of an overall system that may affect the equipment design. Such system requirements may be specified in another part of EN 54, in national legislation, codes and standards or in contractual documents.
- Standard65 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, test methods and performance criteria for fire alarm sounders, including voice sounders, in a fixed installation intended to signal an audible warning between the fire detection and fire alarm systems and the occupants of a building (see EN 54-1:2011).
This European Standard provides for the assessment and verification of constancy of performance (AVCP) of fire alarm sounders to this EN.
This European Standard is not intended to cover:
a) loudspeaker type devices primarily intended for emitting emergency voice messages that are generated from an external audio source;
b) supervisory sounders, for example, within the control and indicating equipment.
- Draft21 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, test methods and performance criteria for fire alarm sounders, including voice sounders, in a fixed installation intended to signal an audible warning between the fire detection and fire alarm systems and the occupants of a building (see EN 54-1:2011).
This European standard provides for the assessment and verification of constancy of performance (AVCP) of fire alarm sounders to this EN.
This European standard is not intended to cover:
a) loudspeaker type devices primarily intended for emitting emergency voice messages that are generated from an external audio source;
b) supervisory sounders, for example, within the control and indicating equipment.
- Standard72 pagesEnglish languagesale 10% offe-Library read for1 day
This annex to EN 54-3 will describe the additional requirements and testing applicable to Audible fire alarm devices - Voice alarm sounders.
Note: a voice alarm sounder is an audible fire alarm device that contains all the necessary components to generate and broadcast recorded voice messages.
- Amendment19 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, test methods and performance criteria for fire alarm sounders in a fixed installation intended to signal an audible warning of fire between a fire detection and fire alarm system and the occupants of a building. It is intended to cover only those devices which derive their operating power by means of a physical electrical connection to an external source such as a fire alarm system.
This standard specifies fire alarm sounders for two types of application environment, type A for indoor use and type B for outdoor use.
This standard is not intended to cover:
a) loudspeaker type devices primarily intended for emitting emergency voice messages;
b) supervisory sounders, for example, within the control and indicating equipment.
- Standard28 pagesEnglish languagesale 10% offe-Library read for1 day