WG 11 - TC 77/SC 77B/WG 11
TC 77/SC 77B/WG 11
General Information
Establishes a common and reproducible reference for evaluating the immunity of electrical and electronic equipment when subjected to electrical fast transient/bursts on supply, signal, control and earth ports. The test method documented in this part of IEC 61000-4 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. The standard defines: - test voltage waveform; - range of test levels; - test equipment; - verification procedures of test equipment; - test set-up; - test procedure. The standard gives specifications for laboratory and post-installation tests. The contents of the corrigenda of August 2006 and June 2007 have been included in this copy.
- Standard31 pagesEnglish languagesale 15% off
- Standard31 pagesFrench languagesale 15% off
- Standard63 pagesEnglish and French languagesale 15% off
- Standard65 pagesEnglish and French languagesale 15% off
This part of IEC 61000-4 relates to the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, with regard to: a) repetitive damped oscillatory waves occurring mainly in power, control and signal cables installed in high voltage and medium voltage (HV/MV) substations; b) repetitive damped oscillatory waves occurring mainly in power, control and signal cables installed in gas insulated substations (GIS) and in some cases also air insulated substations (AIS) or in any installation due to HEMP phenomena. The object of this basic standard is to establish the immunity requirements and a common reference for evaluating in a laboratory the performance of electrical and electronic equipment intended for residential, commercial and industrial applications, as well as of equipment intended for power stations and substations, as applicable. The purpose of this standard is to define: - test voltage and current waveforms; - ranges of test levels; - test equipment; - test setup; - test procedure. The object of this standard is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to damped oscillatory waves. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. It has the status of a basic EMC publication in accordance with IEC Guide 107.
- Standard71 pagesEnglish and French languagesale 15% off
- Standard71 pagesEnglish and French languagesale 15% off
This part of IEC 61000 relates to the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, to non-repetitive damped oscillatory transients (ring waves) occurring in low-voltage power, control and signal lines supplied by public and non-public networks. The object of this basic standard is to establish the immunity requirements and a common reference for evaluating in a laboratory the performance of electrical and electronic equipment intended for residential, commercial and industrial applications, as well as of equipment intended for power stations and substations, as applicable. The purpose of this standard is to define: - test voltage and current waveforms; - ranges of test levels; - test equipment; - test set-up; - test procedure.
- Standard63 pagesEnglish and French languagesale 15% off
IEC 61000-4-5:2005 relates to the immunity requirements, test methods, and range of recommended test levels for equipment to unidirectional surges caused by overvoltages from switching and lightning transients. Several test levels are defined which relate to different environment and installation conditions. These requirements are developed for and are applicable to electrical and electronic equipment. The object of this standard is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to surges. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. This standard defines:
- a range of test levels;
- test equipment;
- test setups;
- test procedures.
The task of the described laboratory test is to find the reaction of the EUT under specified operational conditions, to surge voltages caused by switching and lightning effects at certain threat levels. It is not intended to test the capability of the EUT's insulation to withstand high-voltage stress. Direct injections of lightning currents, i.e, direct lightning strikes, are not considered in this standard. It has the status of a basic EMC publication in accordance with IEC Guide 107.
The contents of the corrigendum of October 2009 have been included in this copy.
- Standard48 pagesEnglish languagesale 15% off
- Standard48 pagesFrench languagesale 15% off
- Standard95 pagesEnglish and French languagesale 15% off
Introduces additional requirements for the calibration of the fast transient/ burst generator. The intention is to improve the reproducibility of the test.
- Standard4 pagesEnglish languagesale 15% off
- Standard4 pagesFrench languagesale 15% off
- Standard7 pagesEnglish and French languagesale 15% off





