ISO/TC 94/SC 14/WG 3 - Wildland firefighting
Lutte contre les feux d'espaces naturels
General Information
This document covers the general design, minimum performance requirements and methods of test for wildland firefighting footwear. This document does not cover PPE for structural firefighting (see ISO 11999 series), for use against chemical, biological, radiological and nuclear hazards, ISO 18639 series PPE for firefighters undertaking specific rescue activities or for use where a reflective outer surface is required (see ISO 15538). Activities in support of wildland firefighting, such as the cutting of trees and the use of a chainsaw can require additional protection to that provided in this document. Users are directed to those relevant standards for the requirements associated with such protection.
- Standard23 pagesEnglish languagesale 15% off
- Draft24 pagesEnglish languagesale 15% off
This document specifies the minimum performance requirements and methods of test for firehoods that cover the head and neck and are used for wildland firefighting. An optional requirement has been included to provide limited protection against particulate contaminants This document covers the general design of the PPE, the minimum levels of performance for the materials employed and the methods of test used. This PPE is not intended to provide protection during fire entrapment. This document does not cover firehoods for structural firefighting (see ISO 11999‑9). This document only applies in situations when compatible protective clothing, helmet, and when necessary respiratory protection devices are also worn.
- Standard16 pagesEnglish languagesale 15% off
- Draft16 pagesEnglish languagesale 15% off
This document specifies the minimum performance requirements and methods of test for helmets used for wildland firefighting. This document covers the general design of wildland firefighting helmets, the minimum levels of performance for the materials employed and the methods of test used. The personal protection equipment (PPE) is not intended to provide protection during fire entrapment. This document does not cover PPE for structural firefighting (see ISO 11999 series), for use against chemical, biological, radiological and nuclear hazards, or for use where a reflective outer surface is required (see ISO 15538). Activities in support of wildland firefighting, such as the cutting of trees and the use of a chainsaw can require additional protection to that provided in this document. Users are directed to those relevant standards for the requirements associated with such protection.
- Standard22 pagesEnglish languagesale 15% off
This document specifies the minimum performance requirements and methods of test for personal protective equipment (PPE), gloves, that cover the hands whilst wildland firefighting. This document covers the general design of the PPE, the minimum levels of performance for the materials employed and the methods of test used. This PPE is not intended to provide protection during fire entrapment. A risk assessment (see ISO/TR 21808) can be undertaken to determine if the gloves covered by this document are suitable for their intended use and the expected exposure. This document does not cover PPE for structural firefighting (see ISO 11999‑4), for use against chemical, biological, radiological and nuclear hazards, or for use where a reflective outer surface is required (see ISO 15538). Activities in support of wildland firefighting, such as the cutting of trees and the use of a chainsaw can require additional protection to that provided in this document. Users can refer to the relevant standards for the requirements associated with such protection.
- Standard17 pagesEnglish languagesale 15% off
This document specifies the minimum performance requirements and test methods for assessing compatibility of wildland firefighters' personal protective equipment (PPE). This document does not cover PPE for structural firefighting (see ISO 11999 series), for use against chemical, biological, radiological and nuclear hazards, or for use where a reflective outer surface is required (see ISO 15538). Activities in support of wildland firefighting, such as the cutting of trees and the use of a chainsaw can require additional compatibility testing to that provided in this document. Users are directed to those relevant standards for the requirements associated with such protection.
- Standard3 pagesEnglish languagesale 15% off
This document specifies the minimum performance requirements and methods of test for personal protective equipment (PPE) face and eye protection, for wildland firefighting. This document covers the general design of the PPE, the minimum levels of performance for the materials employed and the methods of test used. This PPE is not intended to provide protection during fire entrapment. This document does not cover PPE for structural firefighting (see ISO 11999 series), for use against chemical, biological, radiological and nuclear hazards, or for use where a reflective outer surface is required (see ISO 15538). Activities in support of wildland firefighting, such as the cutting of trees and the use of a chainsaw can require additional protection to that provided in this document. Users are directed to those relevant standards for the requirements associated with such protection.
- Standard23 pagesEnglish languagesale 15% off
This document specifies test methods and minimum performance requirements for personal protective clothing, designed to protect the wearer's body, except for the head, hands, and feet, that is worn during wildland firefighting and associated activities. This clothing is not intended to provide protection during fire entrapment. This document covers the general design of the garment, the minimum level of performance for the materials employed and the methods of test to determine these levels. This document is not applicable to clothing for use in situations encountered in structural firefighting (ISO 11999‑3), rescue (ISO 18639‑3) or where a high level of infrared radiation is expected (ISO 15538), nor does this document cover clothing to protect against chemical, biological, electrical or radiation hazards. This document does not provide protection against high mechanical risks such as for protection when using chain saws. NOTE For information on test methods, minimum performance requirements and general design refer to ISO 15384.
- Standard2 pagesEnglish languagesale 15% off
This document specifies the minimum performance requirements and methods of test for personal protective equipment (PPE) covering the torso, neck, arms, hands, legs, feet, head, eyes and hearing that is used for wildland firefighting. This document covers the general design of the PPE, the minimum levels of performance for the materials employed and the methods of test used. The PPE is not intended to provide protection during fire entrapment. This document does not cover PPE for structural firefighting (see ISO 11999 series), for use against chemical, biological, radiological and nuclear hazards, or for use where a reflective outer surface is required (see ISO 15538). Activities in support of wildland firefighting, such as the cutting of trees and the use of a chainsaw can require additional protection to that provided in this document. Users are directed to those relevant standards for the requirements associated with such protection. To assist with selection of the right PPE, a risk assessment (see Annex A) can be conducted to determine the type of PPE, and performance levels, for different categories of protection are required. This document describes performance requirements for PPE and includes requirements for marking and manufacturer's instructions.
- Standard13 pagesEnglish languagesale 15% off
This document specifies the minimum performance requirements and methods of test for hearing protection used when wildland firefighting. This document covers the general design of the personal protective equipment (PPE), the minimum levels of performance for the materials employed and the methods of test used. The PPE is not intended to provide protection during fire entrapment. This document does not cover PPE for structural firefighting (see ISO 11999 series), for use against chemical, biological, radiological and nuclear hazards, or for use where a reflective outer surface is required (see ISO 15538). Activities in support of wildland firefighting, such as the cutting of trees and the use of a chainsaw can require additional protection to that provided in this document. Users are directed to those relevant standards for the requirements associated with such protection.
- Standard4 pagesEnglish languagesale 15% off
- Draft4 pagesEnglish languagesale 15% off