This document specifies a test method for the determination of the resistance of fire dampers to heat, and for the evaluation of their ability to prevent fire and smoke from spreading from one fire compartment to another through an air distribution system. This document describes the test requirements related to intumescent fire dampers. It is intended for intumescent fire dampers that are expected to be classified as EI dampers. Without the addition of a mechanical damper, they are unable to achieve the “S” classification, which includes a leakage limit imposed at ambient temperature. This document is not intended to be used for dampers used only in smoke control systems, for testing fire protection devices which only deal with air transfer applications, or for dampers used in suspended ceilings, as the installation of the damper and duct can have an adverse effect on the performance of the suspended ceiling, requiring other methods of evaluation. NOTE "Air transfer" is a low-pressure application through a fire separation door (or wall, floor) without any connection to an air duct.

  • Standard
    44 pages
    English language
    sale 15% off
  • Draft
    44 pages
    English language
    sale 15% off

This document specifies a test method for the determination of the resistance of fire dampers to heat, and for the evaluation of their ability to prevent fire and smoke spreading from one fire compartment to another through an air distribution system. It is applicable to mechanical fire dampers. It is not intended to be used for dampers used only in smoke control systems, for testing fire protection devices which only deal with air transfer applications, or for dampers used in suspended ceilings, as the installation of the damper and duct can have an adverse effect on the performance of the suspended ceiling, requiring other methods of evaluation. NOTE "Air transfer" is a low-pressure application through a fire separation door (or wall, floor) without any connection to an air duct.

  • Standard
    39 pages
    English language
    sale 15% off

ISO 6944-2:2009 establishes a method of test in which kitchen extract ducts are required to provide fire resistance. The requirements are intended to limit the spread of fire from the duct when a fire occurs within the duct and assesses the structural integrity of the duct when a fire occurs in the area surrounding the duct.

  • Standard
    17 pages
    English language
    sale 15% off

ISO 6944-1:2008 specifies a method for determining the fire resistance of vertical and horizontal ventilation ducts under standardized fire conditions. The test examines the behaviour of ducts exposed to fire from the outside (duct A) and fire inside the duct (duct B). It is intended that ISO 6944-1:2008 be used in conjunction with ISO 834-1. ISO 6944-1:2008 is not applicable to ducts whose fire resistance depends on the fire resistance performance of a ceiling, ducts containing fire dampers at points where they pass through fire separations, doors of inspection openings, unless included in the duct to be tested, two- or three-sided ducts, or the fixing of suspension devices to floors or walls. General guidance and background information are provided.

  • Standard
    32 pages
    English language
    sale 15% off
  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    12 pages
    French language
    sale 15% off

Gives a test method for the determination of the resistance of a fire damper to heat and the passage of smoke and gases at high temperatures. The purpose is to evaluate the ability of a damper to prevent fire and smoke spreading through an air distribution system.

  • Standard
    18 pages
    English language
    sale 15% off
  • Standard
    19 pages
    French language
    sale 15% off
  • Standard
    19 pages
    French language
    sale 15% off

Specifies a method of test and criteria for vertical and horizontal ducts under standardized fire conditions. The general purpose is to measure the ability to resist the spread of fire from one fire compartment to another without the aid of fire dampers. Is applicable to vertical and horizontal ducts with or without branches, taking into account joints, air supply and exhaust openings and suspension devices etc.

  • Standard
    21 pages
    English language
    sale 15% off
  • Standard
    21 pages
    French language
    sale 15% off
  • Standard
    21 pages
    French language
    sale 15% off