This document specifies specifications and test methods for elastomeric seismic isolators used for buildings to guarantee high durability and high performance. It is applicable to elastomeric seismic isolators used to provide buildings with protection from earthquake damage. The isolators covered consist of alternate elastomeric layers and reinforcing steel plates. They are placed between a superstructure and its substructure to provide both flexibility for decoupling structural systems from ground motion, and damping capability to reduce displacement at the isolation interface and the transmission of energy from the ground into the structure at the isolation frequency.

  • Standard
    45 pages
    English language
    sale 15% off

This document specifies minimum requirements and test methods for flat sliding seismic-protection isolators used for buildings and the materials used in the manufacture of such isolators. It is applicable to flat sliding seismic-protection isolators used to provide buildings with protection from earthquake damage. The sliders are each mounted on elastomeric bearings to provide vertical compliance and rotational flexibility about horizontal axes.

  • Standard
    43 pages
    English language
    sale 15% off
  • Draft
    43 pages
    English language
    sale 15% off

This document provides guidance on ISO 22762-3:2018. It includes examples of design calculations, and provides data on the characteristics obtained from all types of elastomeric isolators.

  • Technical specification
    31 pages
    English language
    sale 15% off

This document specifies minimum requirements and test methods for elastomeric seismic isolators used for buildings and the rubber material used in the manufacture of such isolators. It is applicable to elastomeric seismic isolators used to provide buildings with protection from earthquake damage. The isolators covered consist of alternate elastomeric layers and reinforcing steel plates. They are placed between a superstructure and its substructure to provide both flexibility for decoupling structural systems from ground motion, and damping capability to reduce displacement at the isolation interface and the transmission of energy from the ground into the structure at the isolation frequency.

  • Standard
    61 pages
    English language
    sale 15% off

This document specifies minimum requirements and test methods for elastomeric seismic isolators used for bridges, as well as rubber material used in the manufacture of such isolators. It is applicable to elastomeric seismic isolators used to provide bridges with protection from earthquake damage. The isolators covered consist of alternate elastomeric layers and reinforcing steel plates, which are placed between a superstructure and its substructure to provide both flexibility for decoupling structural systems from ground motion and damping capability to reduce displacement at the isolation interface and the transmission of energy from the ground into the structure at the isolation frequency.

  • Standard
    56 pages
    English language
    sale 15% off

This document specifies the test methods for determination of a) the properties of the rubber material used to manufacture the elastomeric seismic isolators, and b) the characteristics of elastomeric seismic isolators. It is applicable to elastomeric seismic isolators used to provide buildings or bridges with protection from earthquake damage. The isolators covered consist of alternate elastomeric layers and reinforcing steel plates which are placed between a superstructure and its substructure to provide both flexibility for decoupling structural systems from ground motion, and damping capability to reduce displacement at the isolation interface and the transmission of energy from the ground into the structure at the isolation frequency.

  • Standard
    79 pages
    English language
    sale 15% off

ISO/TS 22762‑4:2014 provides guidance on the use of ISO 22762‑3:2010. It includes example design calculations and provides data on the characteristics obtained from all types of elastomeric isolators.

  • Technical specification
    31 pages
    English language
    sale 15% off

ISO 22762-2:2010 specifies minimum requirements and test methods for elastomeric seismic isolators used for bridges, as well as rubber material used in the manufacture of such isolators. It is applicable to elastomeric seismic isolators used to provide bridges with protection from earthquake damage. The isolators covered consist of alternate elastomeric layers and reinforcing steel plates which are placed between a superstructure and its substructure to provide both flexibility for decoupling structural systems from ground motion and damping capability to reduce displacement at the isolation interface and the transmission of energy from the ground into the structure at the isolation frequency.

  • Standard
    55 pages
    English language
    sale 15% off

ISO 22762-3:2010 specifies minimum requirements and test methods for elastomeric seismic isolators used for buildings and the rubber material used in the manufacture of such isolators. It is applicable to elastomeric seismic isolators used to provide buildings with protection from earthquake damage. The isolators covered consist of alternate elastomeric layers and reinforcing steel plates. They are placed between a superstructure and its substructure to provide both flexibility for decoupling structural systems from ground motion, and damping capability to reduce displacement at the isolation interface and the transmission of energy from the ground into the structure at the isolation frequency.

  • Standard
    60 pages
    English language
    sale 15% off

ISO 22762-1:2010 specifies the test methods for determination of the properties of the rubber material used to manufacture the elastomeric seismic isolators, and for determination of the characteristics of elastomeric seismic isolators. It is applicable to elastomeric seismic isolators used to provide buildings or bridges with protection from earthquake damage. The isolators covered consist of alternate elastomeric layers and reinforcing steel plates which are placed between a superstructure and its substructure to provide both flexibility for decoupling structural systems from ground motion, and damping capability to reduce displacement at the isolation interface and the transmission of energy from the ground into the structure at the isolation frequency.

  • Standard
    77 pages
    English language
    sale 15% off

ISO 22762 applies to elastomeric seismic isolators used to provide buildings or bridges with protection from earthquake damage. The isolators covered consist of alternate elastomer layers and reinforcing steel plates. They are placed between a superstructure and its substructure to provide both flexibility for decoupling structural systems from ground motion, and damping capability to reduce displacement at the isolation interface and the transmission of energy from the ground into the structure at the isolation frequency. ISO 22762-2:2005 specifies the requirements for elastomeric seismic isolators used for bridges and the requirements for the rubber material used in the manufacture of such isolators. The specification covers requirements, design rules, manufacturing tolerances, marking and labelling and test methods for elastomeric isolators.

  • Standard
    57 pages
    English language
    sale 15% off

ISO 22762 applies to elastomeric seismic isolators used to provide buildings or bridges with protection from earthquake damage. The isolators covered consist of alternate elastomer layers and reinforcing steel plates. They are placed between a superstructure and its substructure to provide both flexibility for decoupling structural systems from ground motion, and damping capability to reduce displacement at the isolation interface and the transmission of energy from the ground into the structure at the isolation frequency. ISO 22762-1:2005 specifies the test methods for determination of the characteristics of elastomeric seismic isolators and for measurement of the properties of the rubber material used in their manufacture. The specifications cover testing for all properties required in the elastomeric isolators, such as compression and shear properties, the durability of the isolators and the physical properties of the materials used in isolators.

  • Standard
    78 pages
    English language
    sale 15% off

ISO 22762 applies to elastomeric seismic isolators used to provide buildings or bridges with protection from earthquake damage. The isolators covered consist of alternate elastomer layers and reinforcing steel plates. They are placed between a superstructure and its substructure to provide both flexibility for decoupling structural systems from ground motion, and damping capability to reduce displacement at the isolation interface and the transmission of energy from the ground into the structure at the isolation frequency. ISO 22762-3:2005 specifies the requirements for elastomeric seismic isolators used for buildings and the requirements for the rubber material used in the manufacture of such isolators. The specification covers requirements, design rules, manufacturing tolerances, marking and labelling and test methods for elastomeric isolators.

  • Standard
    63 pages
    English language
    sale 15% off