Standard Test Methods for Carbon Black-Ash Content

SIGNIFICANCE AND USE
The ash content of a carbon black is the amount of non-carbon components present after combustion. Primary contributants to ash are the manufacturing process water and the catalyst in the feedstock.
SCOPE
1.1 These test methods cover the determination of the ash content of carbon black.
1.2The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements see Sections 6 and 13.

General Information

Status
Historical
Publication Date
30-Apr-2007
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D1506-99(2007) - Standard Test Methods for Carbon Black-Ash Content
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D1506 − 99(Reapproved 2007)
Standard Test Methods for
Carbon Black—Ash Content
This standard is issued under the fixed designation D1506; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope contributants to ash are the manufacturing process water and
the catalyst in the feedstock.
1.1 These test methods cover the determination of the ash
content of carbon black.
Method A—Muffle Furnace Method
1.2 The values stated in SI units are to be regarded as
5. Apparatus
standard. No other units of measurement are included in this
standard.
5.1 Muffle Furnace, capable of temperature regulation of
1.3 This standard does not purport to address all of the 625°C at 550°C.
safety concerns, if any, associated with its use. It is the
5.2 Crucibles:
responsibility of the user of this standard to establish appro-
5.2.1 Porcelain Crucible, high-form, size O, rim 35 mm,
priate safety and health practices and determine the applica- 3
height 29 mm, capacity 15 cm , with cover size E.
bility of regulatory limitations prior to use. For specific
5.2.2 Porous Quartz Fiber Crucible, rim 47 mm, height 14
precautionary statements see Sections 6 and 13. 3
mm, with disk.
5.3 Analytical Balance, having a sensitivity of 0.1 mg.
2. Referenced Documents
5.4 Desiccator.
2.1 ASTM Standards:
D1799 Practice for Carbon Black—Sampling Packaged
5.5 Oven, gravity-convection type, capable of temperature
Shipments
regulation within 61°C at 125°C and temperature uniformity
D1900 Practice for Carbon Black—Sampling Bulk Ship-
within 65°C.
ments
D4483 Practice for Evaluating Precision for Test Method
6. Hazards
Standards in the Rubber and Carbon Black Manufacturing
6.1 Precautions:
Industries
6.1.1 Keep the door of the furnace open about 6 mm to
admit air to support the combustion of organic material.
3. Summary of Test Method
6.1.2 Exert care in removing ashed sample from furnace to
3.1 Apre-driedsample(1hat125°C)isweighedbeforeand
desiccator.
after combustion for 16 h at 550°C. The remaining ash is
6.1.3 Always keep the cover on the crucible when transfer-
weighed and calculated as a percent of the dried sample.
ring it to and from the desiccator to prevent the loss of ash due
to air currents.
4. Significance and Use
6.1.4 Afterthesamplehascooledinthedesiccator,admitair
slowly to avoid loss of ash from the crucible.
4.1 The ash content of a carbon black is the amount of
non-carbon components present after combustion. Primary
7. Sampling
7.1 Samples shall be taken in accordance with Practices
These test methods are under the jurisdiction of ASTM Committee D24 on D1799 or D1900.
Carbon Black and are the direct responsibility of Subcommittee D24.31 on
Non-Carbon Black Components of Carbon Black.
CurrenteditionapprovedMay1,2007.PublishedJuly2007.Originallyapproved
in 1957. Last previous edition approved in 1999 as D1506 – 99. DOI: 10.1520/ The sole source of supply of the apparatus (quartz ashing dishes, Part Number
D1506-99R07. 303040) known to the committee at this time is CEM Corporation, P.O. Box 200,
For referenced ASTM standards, visit the ASTM website, www.astm.org, or Matthews, NC 28106. If you are aware of alternative suppliers, please provide this
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM information to ASTM International Headquarters. Your comments will receive
Standards volume information, refer to the standard’s Document Summary page on careful consideration at a meeting of the responsible technical committee, which
the ASTM website. you may attend.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
D1506 − 99 (2007)
TABLE 1 Precision Parameters for D1506 Ash Content, (Type 1
8. Procedure
Precision)
8.1 Ignite the crucible with cover in the muffle furnace at
Units Percent Ash
550 6 25°C for 1 h. Place the crucible and cover in the
Material Mean Level Sr (r) SR (R)
desiccator. Cool to room temperature and weigh to nearest 0.1
IRB#6 (N330) 0.233 0.018 21.4 0.027 32.4
mg.
SRB D5 (N762) 0.258 0.015 16.0 0.030 32.6
N650 0.289 0.019 18.7 0.031 30.4
8.2 Dry an adequate sample of carbon black for1hinthe
N550 0.436 0.025 16.1 0.037 23.7
gravity-convection oven set at 125°C in an open container of
SRB A5 (N135) 0.565 0.023 11.5 0.056 27.9
Average 0.356
suitable dimensions, so that the depth of the black is no more
Pooled Values 0.020 16.0 0.037 29.7
than 10 mm. Cool and store the sample in a desiccator.
8.3 Weigh 2 60.1 g of the dried carbon black into the
ignited crucible and weigh to the nearest 0.1 mg. Place the
TABLE 2 Interlaboratory Precision Program
uncovered crucible and its cover into the furnace (Note 1)at
Nominal Test Period Material Number of Laboratories
550°C for 16 h (porcelain crucible) or 1.5 h (porous quartz
March 1996 N650 45
fibercrucible–see6.1.1).Coverthecruciblecontainingtheash, October 1996 IRB#6 (N330) 37
March 1997 SRB N762 48
remove from the furnace to the desiccator, and allow to cool to
September 1997 SRB A5 (N135) 43
room temperature. Weigh the covered crucible to the nearest
March 1998 N550 46
0.1 mg. Put the covered crucible back into the desiccator for
additional 0.5 h. Reweigh to the nearest 0.1 mg. Repeat this
weighing process until constant mass is obtained.
NOTE 1—For carbon blacks with very low ash content (such as high
testing was performed using two operators in each laboratory
purityblacks)largersamplemassandlongerashingtimemayberequired.
performing the test once on each of two days (total of four
NOTE 2—If control testing is done at temperatures exceeding 550°C,
some volatile salts may be lost from inorganic ash. tests). A test result is the value obtained from a single
determination. Acceptable difference values were not mea-
9. Calculation
sured. The between operator component of variation is in-
cluded in the calculated values for r and R.
9.1 Calculate the percent ash to the nearest 0.01 % as
follows:
11.4 The results of the precision calculations for this test are
given in Table 1. The materials are arranged in ascending
A 5 D 2 B / C 2 B 3100 (1)
@~ ! ~ !#
“mean level” order.
11.5 Repeatability—The pooled relative repeatability, (r), of
where:
this test has been established as 16.0 %. Any other value in
A = ash, %,
Table 1 may be used as an estimate of repeatability, as
B = mass of crucible, g,
appropriate. The difference between two single test results (or
C = mass of crucible plus the sample, g, and
determinations) found on identical test material under the
D = mass of crucible plus the ash, g.
repeatability conditions prescribed for this test will exceed the
10. Report
repeatability on an average of not more than once in 20 cases
in the normal and correct operation of the method. Two single
10.1 Report the following information:
test results that differ by more than the appropriate value from
10.1.1 Proper identification of the sample, and
Table 1 must be suspected of being from different populations
10.1.2 A result obtained from an individual determination
and some appropriate action taken.
reported to the nearest 0.01 %.
NOTE 3—Appropriate action may be an investigation of the test method
11. Precision and Bias
procedure or apparatus for faulty operation or the declaration of a
significant difference in the two materials, samples, etc., which generated
11.1 These precision statements have been prepared in
the two test results.
accordance with Practice D4483. Refer to this practice for
11.6 Reproducibility—The pooled relative reproducibility,
terminology and other statistical details.
(R),ofthistesthasbeenestablishedas29.7 %.Anyothervalue
11.2 The precision results in this precision and bias section
in Table 1 may be used as an estimate of reproducibility, as
give an estimate of the precision of this test method with the
appropriate. The difference between two single and indepen-
materials used in the particular interlaboratory program de-
dent test results found by two operators working under the
scribed below.The precision parameters should not be used for
prescribed reproducibility conditions in different laboratories
acceptance or rejection testing of any
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.