Standard Specification for Insulation Resistance Monitor for Shipboard Electrical Motors and Generators

SCOPE
1.1 This specification covers monitoring devices (monitors) for the automatic detection and signaling of low insulation resistance values in idle electrical motors or generators, or both.
1.2 Monitors are intended for permanent installation in both existing or new panels and controller enclosures designed for marine application.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 The following safety hazards caveat pertains only to the test method described in this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-Dec-1993
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F1134-94 - Standard Specification for Insulation Resistance Monitor for Shipboard Electrical Motors and Generators
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

ASTM F3334 94 m 0759530 0538131 745 m
AMERICAN SOCIETY FOR TESTING AND MATERIALS
[[b Designation: F 1134 - 94
1916 Raze St. Philadelphia; Pa 191 03
Reprinted from the Annual Book of ASTM Standards. CopyrigM ASTM
If not listed In the current combined index will appear in the next edition
Standard Specification for
Insulation Resistance Monitor for Shipboard Electrical Motors
and Generators’
This standard is isrued under the fixed designation F 1134; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
(t) indicates an editorial change since the last revision or reapproval.
superscript epsilon
leakage resistance of electrical machine windings to ground,
1. Scope
while the monitored machine stands idle.
1.1 This specification covers monitoring devices (mon-
itors) for the automatic detection and signaling of low
4. Monitor Classification
insulation resistance values in idle electrical motors or
4.1 Type-The insulation resistance monitors covered by
generators, or both.
this specification shall be of the following types:
1.2 Monitors are intended for permanent installation in
1 Type I-Alternating current motor monitors.
4,l.
both existing or new panels and controller enclosures de-
4.1.2 Type 11-Alternating current generator monitors.
signed for marine application.
4.1.3 Type 111-Direct current motor monitors.
1.3 The values stated in SI units are to be regarded as the
4.1.4 Type IV-Direct current generator monitors.
standard. The values given in parentheses are for informa-
4.2 Duty Rating-All monitors shall be capable of contin-
tion only.
as defined in accordance with
uous duty operations
1.4 The following safety hazards caveat pertains only to
IEEE 100.
the test method described in this specification: This standard
does not purport to address all of the safety concerns, ifany,
5. Ordering Information
associated with its use. It is the responsibility of ihe user of
5.1 Monitoring devices shall be ordered by including the
this standard to establish appropriate safety and health
following information:
of regulatory limi-
practices and determine the applicability
5.1.1 Purpose or Use of Monitor(s)-Application as motor
tations prior to use,
or generator monitor.
5.1.2 Line voltage and frequency.
2. Referenced Documents
5.1.3 Control voltage and frequency.
2.1 UL Standard:
5.1.4 Type of starter (if motor monitor).
UL94 Test for Flammability of Plastic Materials for Parts
5.1.5 Winding configuration (if motor monitor).
in Devices and Appliances2
5.1.6 Location of monitor.
2.2 IEEE Standards:
5.1.7 SensitivitpSet for 1 megohm (optional setting, if
IEEE 45 Recommended Practice for Electrical Installa-
requested, from 0.1 to 5 MQ),
tions on Shipboard3
5.1.8 Remote monitoring devices.
IEEE 100 Standard Dictionary of Electrical and Elec-
5.1.9 Special options requested (that is, test buttons,
tronics Terms3
elevated ambient temperature usage, etc.).
2.3 Government Siandard:
Title 46 Code of Federal Regulations Shipping4
6. Materials and Manufacture
6.1 General-Materials used in the construction of insu-
3. Terminology
lation resistance monitors are to be manufactured and tested
3.1 Definitions-In general definitions shall be in accor-
in accordance with IEEE 45. Materials conforming to other
dance with IEEE 100 (see Section 2).
recognized standards will be subject to approval by the
3.2 Descriptions of Terms Specific to This Standard:
procuring agency, provided they are not less effective.
3.2.1 idle machine-rotary machine, when not rotating,
6.2 Flame-Retardant Materials-Enclosure materials
owing to the absence of energy.
used in the construction of the monitors are to be flame-
3.2.2 monitor-device, generally located in a motor
retardant in. accordance with UL94, and have a minimum
starter, control panel, or main switchboard, that senses the
flame rating of 94V-1 for monitors being installed within a
motor controller enclosure, or switchgear-type enclosure, or
a minimum rating of 94-5V for monitors not installed within
This specification is under the jurisdiction of ASTM Committee F-25 on
Shipbuilding and is the direct responsibility of Subcommittee F25. IO on Electrical,
such an enclosure.
Electronics, and Automation.
6.3 Electrical Insulation-Electrical insulation materials
Current edition approved Feb. IS, 1994. Published April 1994. Originally
used and application thereof shall be in accordance with the
published as F I 134 - 88. Lasrprevious edition F 1 134 - 88.
Available from Undenvriters Laboratories, Inc. 333 Plingsten Rd., requirements of IEEE 45.
Northbrook, 1L 60062.
6.4 Current Carrying Terminals-All monitor current
’ Available
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.