Standard Practice for Applied Weight Per Unit Area of Liquid Adhesive

SIGNIFICANCE AND USE
For the bonding of adherends, the amount of adhesive present is critical and it is important to understand that this practice does not ensure sufficient adhesive is present on the adherend surface.
This practice can be used to supplement industry uses such as that of visually checking the spread or the use of mil-thickness gages.
In laboratory and industrial operations, hand or mechanical application of adhesives can be duplicated for cost savings using this practice.
SCOPE
1.1 This practice provides a procedure for the estimation of the quantity of liquid adhesive applied in a spreading or coating operation.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
30-Apr-2007
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D899-00(2007) - Standard Practice for Applied Weight Per Unit Area of Liquid Adhesive
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D899 − 00 (Reapproved 2007)
StandardPractice for
Applied Weight Per Unit Area of Liquid Adhesive
This standard is issued under the fixed designation D899; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope 4. Significance and Use
1.1 This practice provides a procedure for the estimation of
4.1 For the bonding of adherends, the amount of adhesive
thequantityofliquidadhesiveappliedinaspreadingorcoating
present is critical and it is important to understand that this
operation.
practice does not ensure sufficient adhesive is present on the
adherend surface.
1.2 The values stated in SI units are to be regarded as the
standard. The values given in parentheses are for information
4.2 This practice can be used to supplement industry uses
only.
such as that of visually checking the spread or the use of
1.3 This standard does not purport to address all of the mil-thickness gages.
safety concerns, if any, associated with its use. It is the
4.3 In laboratory and industrial operations, hand or me-
responsibility of the user of this standard to establish appro-
chanical application of adhesives can be duplicated for cost
priate safety and health practices and determine the applica-
savings using this practice.
bility of regulatory limitations prior to use.
5. Apparatus
2. Referenced Documents
5.1 The following apparatus is required for this practice:
2.1 ASTM Standards:
5.1.1 A balance, capable of weighing the material accu-
D907 Terminology of Adhesives
rately to the nearest 1 %, and
5.1.2 A suitable instrument for measuring the linear dimen-
3. Terminology
sions of the specimens to the nearest 1 %.
3.1 Definitions—Several terms in this practice are defined in
accordance with Terminology D907.
6. Test Specimens
3.2 Definitions of Terms Specific to This Standard:
6.1 Select test specimens from portions of the actual mate-
3.2.1 spreading or coating weight per unit area, n—the total
rial to be coated or spread, or from the same lot or a similar
quantity of liquid adhesive uniformly applied, expressed in
one,havingthesamephysicalcharacteristicssuchasthickness,
pounds per thousand square feet of joint or surface area. (See
density, or texture.
spread in Terminology D907.)
3.2.2 test specimen, n—the material that is to be coated with 6.2 Thesizeofthespecimenmayvarywiththenatureofthe
adhesive. (See adherend in Terminology D907). substrate.
3.2.3 total quantity of liquid adhesive applied— the weight
NOTE 1—Materials of low porosity normally require larger test speci-
of the adhesive on the test specimen as applied on the surface
mens than materials of high porosity.
or at the glue joint, whether resulting from a single spread, a
6.3 Use simple geometric shapes for the test specimens to
double spread, or multiple applications.
facilitate precise measurement of dimensions.
6.4 For operations involving the coating or spreading of
1 sheeted stock, individual plies or lamina of the adherend, a
This practice is under the jurisdiction of ASTM Committee D14 on Adhesives
and is the direct responsibility of Subcommittee D14.10 on Working Properties minimum of 5 test specimens is required for determining the
Current edition approved May 1, 2007. Published May 2007. Originally
average weight of liquid adhesive applied.
approved in 1947. Last previous edition approved in 2000 as D899 – 00. DOI:
10.1520/D0899-00R07.
6.5 For operations where the test specimen is in continuous
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
form, such as roll stock of paper or fabric, use a test specimen
contact ASTM
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.