SIGNIFICANCE AND USE
5.1 This test method establishes water immersion, drying, and cleaning procedures to be used when determining whether building materials noted in 1.1 are flood damage resistant for applications that comply with the National Flood Insurance Program (NFIP) [44 CFR § 60.3(a)(3)].
5.2 This test method exposes the test specimen to water immersion and drying conditions to simulate the effects of wetting and subsequent drying that occurs with a flood event. The wetting and drying exposure is followed by surface cleaning. This test method provides a measure of how test specimens may respond to water immersion, subsequent drying, and cleaning that occur with flood events.
5.3 This test method is useful for determining water absorption characteristics of different test specimens in terms of percent increase in test specimen weight, their drying characteristics in terms of elapsed time to dry to equilibrium weight, and changes in physical appearance following water immersion and surface cleaning.
5.4 This test method is useful in comparing the water absorption characteristics of different test specimens, their drying characteristics, and changes in physical appearance following water immersion and surface cleaning. This test method is also useful in comparing test specimen physical dimensions before water immersion, immediately following removal from water immersion, after drying, and after cleaning.
5.5 The ability to directly compare test results will vary by many factors including test specimen size and whether test specimens are individual building materials or composite assemblies of building materials.
SCOPE
1.1 This test method is intended to apply to building materials used in construction below the base flood elevation (BFE) including, but not limited to: individual building materials and composite assemblies of building materials that constitute permanent integral parts of a finished building including walls, floors, ceilings, stairways, built-in partitions, finishes, cladding, and other similarly incorporated architectural and structural items.
1.2 Requirements for evaluation of other hazards associated with flood damage including, but not limited to: debris impact, flood velocity, wave action, water pressure differential, scour, erosion, biological and chemical contaminants in floodwater, and other factors that would be adverse to continued use of the structure for its intended purpose including long-term occupant health impacts are outside of the scope of the methods presented herein.
1.3 The water immersion, drying, and cleaning procedures specified in this test method establishes standard conditions for laboratory evaluation of test specimen response to water immersion, subsequent drying, and cleaning. The results of these tests are one factor in assessing the characteristics of building materials with regard to water immersion, drying, and ability to be cleaned. Application of these test results to predict these characteristics for actual building construction requires the evaluation of test conditions as compared to conditions of end-use.
1.4 The water immersion and drying procedures shall not be construed as representative of water makeup, duration of immersion, or conditions of drying during an actual flood event because actual flood conditions vary with such factors as makeup of water, depth and duration of immersion, and ambient temperature and humidity.
1.5 The cleaning procedures specified in this test method are intended to simulate surface cleaning that normally occurs after flooding.
1.6 The cleaning procedures specified in this test method shall not be construed as superseding standards or manufacturer’s recommended methods for cleaning and restoration after flooding.
1.7 A commentary to this test method is provided in Appendix X1.
1.8 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mat...
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: E3075 − 16
Standard Test Method for
Water Immersion and Drying for Evaluation of Flood
1
Damage Resistance
This standard is issued under the fixed designation E3075; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
INTRODUCTION
Theperformanceofconstructionmaterialsduringfloodeventsisanitemofimportanceforproperty
owners and communities, especially those located in flood-prone areas. Requirements for the use of
flood-resistantbuildingmaterialsinfloodhazardareascanbefoundintheUSmodelcodes,standards,
and guidelines pertaining to flood resistant design and construction. To promote uniformity in
evaluation of building material response to flooding, this test method prescribes standard conditions
for water immersion, subsequent drying, and cleaning such as occur during flood events. Other
deleterious effects of floods that are outside the scope of this test method include, but are not limited
to,debrisimpact,floodvelocity,waveaction,waterpressuredifferential,scour,erosion,biologicaland
chemical contaminants in floodwater, and other factors including long-term occupant health impacts
that would be adverse to continued use of the structure.
1. Scope abilitytobecleaned.Applicationofthesetestresultstopredict
these characteristics for actual building construction requires
1.1 This test method is intended to apply to building
the evaluation of test conditions as compared to conditions of
materials used in construction below the base flood elevation
end-use.
(BFE) including, but not limited to: individual building mate-
rials and composite assemblies of building materials that 1.4 Thewaterimmersionanddryingproceduresshallnotbe
constitute permanent integral parts of a finished building construed as representative of water makeup, duration of
including walls, floors, ceilings, stairways, built-in partitions, immersion,orconditionsofdryingduringanactualfloodevent
finishes, cladding, and other similarly incorporated architec- because actual flood conditions vary with such factors as
tural and structural items. makeup of water, depth and duration of immersion, and
ambient temperature and humidity.
1.2 Requirements for evaluation of other hazards associated
with flood damage including, but not limited to: debris impact, 1.5 Thecleaningproceduresspecifiedinthistestmethodare
flood velocity, wave action, water pressure differential, scour, intendedtosimulatesurfacecleaningthatnormallyoccursafter
erosion, biological and chemical contaminants in floodwater, flooding.
and other factors that would be adverse to continued use of the
1.6 The cleaning procedures specified in this test method
structureforitsintendedpurposeincludinglong-termoccupant
shall not be construed as superseding standards or manufac-
health impacts are outside of the scope of the methods
turer’s recommended methods for cleaning and restoration
presented herein.
after flooding.
1.3 The water immersion, drying, and cleaning procedures
1.7 A commentary to this test method is provided in
specifiedinthistestmethodestablishesstandardconditionsfor
Appendix X1.
laboratory evaluation of test specimen response to water
1.8 The values stated in inch-pound units are to be regarded
immersion, subsequent drying, and cleaning. The results of
as standard. The values given in parentheses are mathematical
these tests are one factor in assessing the characteristics of
conversions to SI units that are provided for information only
buildingmaterialswithregardtowaterimmersion,drying,and
and are not considered standard.
1.9 This standard does not purport to address all of the
1
This test method is under the jurisdiction of ASTM Committee E06 on
safety concerns, if any, associated with its use. It is the
Performance of Buildings and is the direct responsibility of Subcommittee E06.25
responsibility of the user of this standard to establish appro-
on Whole Buildings and Facilities.
priate safety and health practices and determine the applica-
Current edition approved Dec. 1, 2016. Published December 2016. DOI:
10.1520/E3075-16. bility of regulatory limitations prior to use.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
E3075 − 16
2. Referenced Documents wetting and subsequent drying that occurs with a flood event.
2 The wetting and drying exposure is followed by surface
2.1 ASTM Standard:
cleaning. This test method provides a measure of how test
D7789Practice for Collection of Fungal Material from
specimens may respond to water immersion, subsequent
Surfaces by Swab
d
...