Standard Test Methods for Evaluating Water-Resistive Barrier (WRB) Coatings Used under Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage

SIGNIFICANCE AND USE
4.1 This series of test methods provides a means to evaluate performance of the water-resistive barrier coating when subjected to various physical and environmental conditions. The water-resistive barrier coating is applied between the EIFS and substrate in an EIFS-clad wall assembly and is intended to provide additional protection to the building and its contents from incidental moisture intrusion that may occur through the building envelope. Although protected from direct weather exposure after the EIFS is installed, the coating must be durable and weather resistant as it is subjected to various environmental conditions prior to application of the EIFS as well as while the system is in service.
SCOPE
1.1 These test methods apply to trowel, roller, or spray applied Water-resistive barrier (WRB) coatings that are applied over exterior sheathing prior to application of EIFS or EIFS with drainage wall claddings.  
1.2 Test methods for in place wall system and cladding related to tests such as fire resistance, wind load capability, air barrier performance, and so forth. should also be considered but are outside the scope of this document.  
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
31-Mar-2019
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM E2570/E2570M-07(2019) - Standard Test Methods for Evaluating Water-Resistive Barrier (WRB) Coatings Used under Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: E2570/E2570M − 07 (Reapproved 2019)
Standard Test Methods for
Evaluating Water-Resistive Barrier (WRB) Coatings Used
under Exterior Insulation and Finish Systems (EIFS) or EIFS
1
with Drainage
This standard is issued under the fixed designation E2570/E2570M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope Sandwich Constructions
D2247 Practice for Testing Water Resistance of Coatings in
1.1 These test methods apply to trowel, roller, or spray
100 % Relative Humidity
applied Water-resistive barrier (WRB) coatings that are applied
D2898 Practice for Accelerated Weathering of Fire-
over exterior sheathing prior to application of EIFS or EIFS
Retardant-Treated Wood for Fire Testing
with drainage wall claddings.
E72 Test Methods of Conducting Strength Tests of Panels
1.2 Test methods for in place wall system and cladding
for Building Construction
related to tests such as fire resistance, wind load capability, air
E96/E96M Test Methods for Gravimetric Determination of
barrier performance, and so forth. should also be considered
Water Vapor Transmission Rate of Materials
but are outside the scope of this document.
E330/E330M Test Method for Structural Performance of
1.3 The values stated in either SI units or inch-pound units Exterior Windows, Doors, Skylights and Curtain Walls by
Uniform Static Air Pressure Difference
are to be regarded separately as standard. The values stated in
each system are not necessarily exact equivalents; therefore, to E331 Test Method for Water Penetration of Exterior
Windows, Skylights, Doors, and Curtain Walls by Uni-
ensure conformance with the standard, each system shall be
used independently of the other, and values from the two form Static Air Pressure Difference
E631 Terminology of Building Constructions
systems shall not be combined.
E1233/E1233M Test Method for Structural Performance of
1.4 This standard does not purport to address all of the
Exterior Windows, Doors, Skylights, and Curtain Walls by
safety concerns, if any, associated with its use. It is the
Cyclic Air Pressure Differential
responsibility of the user of this standard to establish appro-
E2110 Terminology for Exterior Insulation and Finish Sys-
priate safety, health, and environmental practices and deter-
tems (EIFS)
mine the applicability of regulatory limitations prior to use.
E2134/E2134M Test Method for Evaluating the Tensile-
1.5 This international standard was developed in accor-
Adhesion Performance of an Exterior Insulation and
dance with internationally recognized principles on standard-
Finish System (EIFS)
ization established in the Decision on Principles for the
E2485/E2485M Test Method for Freeze/Thaw Resistance of
Development of International Standards, Guides and Recom-
Exterior Insulation and Finish Systems (EIFS) and Water
mendations issued by the World Trade Organization Technical
Resistive Barrier Coatings
Barriers to Trade (TBT) Committee.
3
2.2 AATCC Standard:
AATCC 127 Water Resistance: Hydrostatic Pressure Test
2. Referenced Documents
2
2.1 ASTM Standards: 3. Terminology
C297/C297M Test Method for Flatwise Tensile Strength of
3.1 Definitions related to EIFS may be found in Terminol-
ogy E2110 and general terms in Terminology E631.
1
This test method is under the jurisdiction of ASTM Committee E06 on
4. Significance and Use
Performance of Buildings and is the direct responsibility of Subcommittee E06.58
4.1 This series of test methods provides a means to evaluate
on Exterior Insulation and Finish Systems (EIFS).
Current edition approved April 1, 2019. Published April 2019. Originally performance of the water-resistive barrier coating when sub-
e1
approved in 2007. Last previous edition approved in 2014 as E2570–07 (2014) .
jected to various physical and environmental conditions. The
DOI: 10.1520/E2570_E2570M-07R19.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
3
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Available from American Association of Textile Chemists and Colorists
Standards volume information, refer to the standard’s Document Summary page on (AATCC), P.O. Box 12215, Research Triangle Park, NC 27709-2215, http://
the ASTM website. www.aatcc.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E2570/E2570M − 07 (2019)
w
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.