ASTM F2764-10e1
(Specification)Standard Specification for 30 to 60 in. [750 to 1500 mm] Polypropylene (PP) Triple Wall Pipe and Fittings for Non-Pressure Sanitary Sewer Applications
Standard Specification for 30 to 60 in. [750 to 1500 mm] Polypropylene (PP) Triple Wall Pipe and Fittings for Non-Pressure Sanitary Sewer Applications
ABSTRACT
This specification covers requirements and test methods for triple wall polypropylene pipe and fittings with nominal inside diameters of 30 to 60 in. [750 to 1600 mm]. These requirements are intended to provide pipe and fittings suitable for underground use for non-pressure sanitary sewer systems. Pipe and fittings produced in accordance with this specification shall be installed in compliance with Practice D2321. Pipe and fittings with a interior wall, a exterior wall and an annular corrugated profile middle wall are covered by this specification.
SCOPE
1.1 This specification covers requirements and test methods for triple wall polypropylene pipe and fittings. The nominal inside diameters covered are 30 to 60 in. [750 to 1600 mm].
1.2 The requirements of this specification are intended to provide pipe and fittings suitable for underground use for non-pressure sanitary sewer systems. Pipe and fittings produced in accordance with this specification shall be installed in compliance with Practice D2321.
1.3 This specification covers pipe and fittings with a interior wall, a exterior wall and an annular corrugated profile middle wall (Fig. 1).
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.5 The following precautionary statement applies only to Section 7 of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
An American National Standard
´1
Designation: F2764 – 10
Standard Specification for
30 to 60 in. [750 to 1500 mm] Polypropylene (PP) Triple Wall
Pipe and Fittings for Non-Pressure Sanitary Sewer
1
Applications
This standard is issued under the fixed designation F2764; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1
´ NOTE—Appendix X3 was editorially corrected in April 2010.
1. Scope D638 Test Method for Tensile Properties of Plastics
D790 Test Methods for Flexural Properties of Unreinforced
1.1 This specification covers requirements and test methods
and Reinforced Plastics and Electrical Insulating Materials
for triple wall polypropylene pipe and fittings. The nominal
D792 Test Methods for Density and Specific Gravity (Rela-
inside diameters covered are 30 to 60 in. [750 to 1600 mm].
tive Density) of Plastics by Displacement
1.2 The requirements of this specification are intended to
D1238 Test Method for Melt Flow Rates of Thermoplastics
provide pipe and fittings suitable for underground use for
by Extrusion Plastometer
non-pressure sanitary sewer systems. Pipe and fittings pro-
D1505 Test Method for Density of Plastics by the Density-
duced in accordance with this specification shall be installed in
Gradient Technique
compliance with Practice D2321.
D1600 Terminology for Abbreviated Terms Relating to
1.3 This specification covers pipe and fittings with a interior
Plastics
wall, a exterior wall and an annular corrugated profile middle
D2122 Test Method for Determining Dimensions of Ther-
wall (Fig. 1).
moplastic Pipe and Fittings
1.4 The values stated in either SI units or inch-pound units
D2321 Practice for Underground Installation of Thermo-
are to be regarded separately as standard. The values stated in
plastic Pipe for Sewers and Other Gravity-Flow Applica-
each system may not be exact equivalents; therefore, each
tions
system shall be used independently of the other. Combining
D2412 Test Method for Determination of External Loading
values from the two systems may result in non-conformance
Characteristics of Plastic Pipe by Parallel-Plate Loading
with the standard.
D2444 Test Method for Determination of the Impact Resis-
1.5 The following precautionary statement applies only to
tance of Thermoplastic Pipe and Fittings by Means of a
Section 7 of this specification. This standard does not purport
Tup (Falling Weight)
to address all of the safety concerns, if any, associated with its
D2990 Test Methods for Tensile, Compressive, and Flex-
use. It is the responsibility of the user of this standard to
ural Creep and Creep-Rupture of Plastics
establish appropriate safety and health practices and deter-
D3212 Specification for Joints for Drain and Sewer Plastic
mine the applicability of regulatory limitations prior to use.
Pipes Using Flexible Elastomeric Seals
2. Referenced Documents
D3895 Test Method for Oxidative-Induction Time of Poly-
2
olefins by Differential Scanning Calorimetry
2.1 ASTM Standards:
D4101 Specification for Polypropylene Injection and Extru-
A666 Specification for Annealed or Cold-Worked Austen-
sion Materials
itic Stainless Steel Sheet, Strip, Plate, and Flat Bar
D4218 Test Method for Determination of Carbon Black
D256 Test Methods for Determining the Izod Pendulum
Content in Polyethylene Compounds By the Muffle-
Impact Resistance of Plastics
Furnace Technique
D618 Practice for Conditioning Plastics for Testing
D4389 Specification for Finished Glass Fabrics Woven
From Rovings
1
This specification is under the jurisdiction ofASTM Committee F17 on Plastic
D6992 Test Method for Accelerated Tensile Creep and
Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.
Creep-Rupture of Geosynthetic Materials Based on Time-
Current edition approved April 15, 2010. Published April 2010. DOI:10.1520/
Temperature Superposition Using the Stepped Isothermal
D2764–10E01.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Method
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
´1
F2764 – 10
FIG. 1 Typical Triple Wall Pipe Profile
F412 Terminology Relating to Plastic Piping Systems 4.1.4 Pipe laying length,
F477 SpecificationforElastomericSeals(Gaskets)forJoin- 4.1.5 Fitting type(s):
ing Plastic Pipe
4.1.5.1 Size and type of fittings, including mainline and
F2136 Test Method
...
Questions, Comments and Discussion