ASTM F3240-19e1
(Practice)Standard Practice for Installation of Seamless Molded Hydrophilic Gaskets (SMHG) for Long-Term Watertightness of Cured-in-Place Rehabilitation of Main and Lateral Pipelines
Standard Practice for Installation of Seamless Molded Hydrophilic Gaskets (SMHG) for Long-Term Watertightness of Cured-in-Place Rehabilitation of Main and Lateral Pipelines
SIGNIFICANCE AND USE
5.1 This practice is for use by designers and specifiers, regulatory agencies, owners, and inspection organizations that are involved in the rehabilitation of main and lateral pipelines and manholes. As for any practice, modifications may be required for specific job conditions.
SCOPE
1.1 This practice covers the requirements for the installation of seamless molded hydrophilic gaskets (SMHG) in cured-in-place pipe (CIPP) rehabilitation of main and lateral pipelines.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 There is no similar or equivalent ISO Standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
Relations
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
´1
Designation: F3240 − 19
Standard Practice for
Installation of Seamless Molded Hydrophilic Gaskets
(SMHG) for Long-Term Watertightness of Cured-in-Place
1,2
Rehabilitation of Main and Lateral Pipelines
This standard is issued under the fixed designation F3240; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1
ε NOTE—6.1.2 and the caption of Fig. 4 were editorially corrected in December 2019.
1. Scope* 2. Referenced Documents
3
1.1 Thispracticecoverstherequirementsfortheinstallation 2.1 ASTM Standards:
of seamless molded hydrophilic gaskets (SMHG) in cured-in- D1149 Test Methods for Rubber Deterioration—Cracking in
place pipe (CIPP) rehabilitation of main and lateral pipelines. an Ozone Controlled Environment
D1600 TerminologyforAbbreviatedTermsRelatingtoPlas-
1.2 The values stated in inch-pound units are to be regarded
tics
as standard. The values given in parentheses are mathematical
D2240 Test Method for Rubber Property—Durometer Hard-
conversions to SI units that are provided for information only
ness
and are not considered standard.
F412 Terminology Relating to Plastic Piping Systems
1.3 There is no similar or equivalent ISO Standard.
F1216 Practice for Rehabilitation of Existing Pipelines and
1.4 This standard does not purport to address all of the
Conduits by the Inversion and Curing of a Resin-
safety concerns, if any, associated with its use. It is the Impregnated Tube
responsibility of the user of this standard to establish appro-
F1743 Practice for Rehabilitation of Existing Pipelines and
priate safety, health, and environmental practices and deter- ConduitsbyPulled-in-PlaceInstallationofCured-in-Place
mine the applicability of regulatory limitations prior to use.
Thermosetting Resin Pipe (CIPP)
1.5 This international standard was developed in accor- F2019 Practice for Rehabilitation of Existing Pipelines and
dance with internationally recognized principles on standard- Conduits by the Pulled in Place Installation of Glass
ization established in the Decision on Principles for the
Reinforced Plastic (GRP) Cured-in-Place Thermosetting
Development of International Standards, Guides and Recom- Resin Pipe (CIPP)
mendations issued by the World Trade Organization Technical
F2599 Practice for The Sectional Repair of Damaged Pipe
Barriers to Trade (TBT) Committee. By Means of An Inverted Cured-In-Place Liner
F2561 Practice for Rehabilitation of a Sewer Service Lateral
and Its Connection to the Main Using a One Piece Main
1
This practice is under the jurisdiction of ASTM Committee F17 on Plastic
and Lateral Cured-in-Place Liner
Piping Systems and is the direct responsibility of Subcommittee F17.67 on
4
Trenchless Plastic Pipeline Technology. 2.2 NASSCO Guidelines:
Current edition approved Sept. 15, 2019. Published September 2019. Originally
Recommended Specifications for Sewer Collection System
approved in 2017. Last previous edition approved in 2017 as F3240–17.DOI:
Rehabilitation.
10.1520/F3240–19E01.
2
Practice for Installation of Seamless Molded Hydrophilic Gaskets (SMHG) for PACP NASSCO Pipeline Assessment & Certification Pro-
Long-Term Watertightness of Cured-in-Place Rehabilitation of Main and Lateral
gram
Pipelines is covered by patents 6,994,118, 7,975,726, 8,240,340, 8,240,341,
8,567,451, 8,636,036, 8,651,145, 8,667,991, 8,678,037, 8,689,835, 9,169,957,
3
9,366,375, 9,562,339, 9,551,449, (LMK Technologies, Inc. 1779 Chessie Lane, For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Ottawa,IL61350).Interestedpartiesareinvitedtosubmitinformationregardingthe contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
identification of acceptable alternatives to this patented item to the Committee on Standards volume information, refer to the standard’s Document Summary page on
Standards, ASTM Headquarters, 100 Barr Harbor Drive, West Conshohocken, PA the ASTM website.
4
19428-2959. Your comments will receive careful consideration at a meeting of the Available from NASSCO 2470 Longstone Lane, Suite M Marriottsville, MD
responsible technical committee, which you may attend. 21104 https://www.nassco.org/
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
´1
F3240 − 19
5
2.3 ISO Standard
ISO 17025 General requirements for
...
Questions, Comments and Discussion