ASTM C1149-02
(Specification)Standard Specification for Self-Supported Spray Applied Cellulosic Thermal Insulation
Standard Specification for Self-Supported Spray Applied Cellulosic Thermal Insulation
SCOPE
1.1 The specification covers the physical properties of self-supported spray applied cellulosic fibers intended for use as thermal insulation or an acoustical absorbent material, or both.
1.2 This specification covers chemically treated cellulosic materials intended for pneumatic applications where temperatures do not exceed 82.2°C (180°F) and where temperatures will routinely remain below 65.6°C (150°F).
1.2.1 Type I—Material applied with liquid adhesive and suitable for either exposed or enclosed applications.
1.2.2 Type II—Materials containing a dry adhesive that is activated by water during installation and intended only for enclosed or covered applications.
1.3 This is a material specification only and is not intended to deal with methods of application that are supplied by the manufacturer.
1.4 The values stated in SI units are to be regarded as standard. The inch-pound units given in parentheses are for information only.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 1149 – 02
Standard Specification for
1
Self-Supported Spray Applied Cellulosic Thermal Insulation
This standard is issued under the fixed designation C 1149; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
2
1. Scope Loose-Fill Thermal Insulation
C 976 Test Method for Thermal Performance of Building
1.1 The specification covers the physical properties of
2
Assemblies by Means of a Calibrated Hot Box
self-supported spray applied cellulosic fibers intended for use
E 84 Test Method for Surface Burning Characteristics of
as thermal insulation or an acoustical absorbent material, or
3
Building Materials
both.
E 605 Test Methods for Thickness and Density of Sprayed
1.2 This specification covers chemically treated cellulosic
3
Fire-Resistive Material Applied to Structural Members
materials intended for pneumatic applications where tempera-
E 736 Test Method for the Cohesion/Adhesion of Sprayed
tures do not exceed 82.2°C (180°F) and where temperatures
3
Fire-Resistive Materials Applied to Structural Members
will routinely remain below 65.6°C (150°F).
E 759 Test Method for Effect of Deflection of Sprayed
1.2.1 Type I—Material applied with liquid adhesive and
3
Fire-Resistive Material Applied to Structural Members
suitable for either exposed or enclosed applications.
E 859 Test Method for Air Erosion of Sprayed Fire-
1.2.2 Type II—Materials containing a dry adhesive that is
3
Resistive Materials Applied to Structural Members
activated by water during installation and intended only for
enclosed or covered applications.
3. Terminology
1.3 This is a material specification only and is not intended
3.1 Definitions—Definitions in Terminology C 168 shall
to deal with methods of application that are supplied by the
apply in this specification.
manufacturer.
3.2 Definitions of Terms Specific to This Standard:
1.4 The values stated in SI units are to be regarded as
3.2.1 constant mass—no change in successive weighings in
standard. The inch-pound units given in parentheses are for
excess of 0.5 % of specimen mass taken at 4-h intervals unless
information only.
otherwise specified. Specimen should not be always increasing
1.5 This standard does not purport to address all of the
in weight or decreasing in weight.
safety concerns, if any, associated with its use. It is the
3.2.2 cured—the state of the finished product after it has
responsibility of the user of this standard to establish appro-
achieved constant mass.
priate safety and health practices and determine the applica-
3.2.3 curing—the process in which the liquid vehicle is
bility of regulatory limitations prior to use.
removed. Normally achieved in ambient building conditions
2. Referenced Documents with forced air convection to hasten the evaporation process.
3.2.4 prepared sample—samples prepared in accordance
2.1 ASTM Standards:
2
with Section 5 and cured to constant mass prior to conducting
C 168 Terminology Relating to Thermal Insulation
thespecifictests.Thepreparedsamples,afterreachingconstant
C 177 Test Method for Steady-State Heat Flux Measure-
mass, as defined in 3.2.1, shall have a density within 610 % of
ments and Thermal Transmission Properties by Means of
2 the manufacturer’s recommended design density.
the Guarded-Hot-Plate Apparatus
3.2.5 self supporting—a product that can be tested by the
C 236 Test Method for Steady-State Thermal Performance
2 criteria imposed by this specification and that will require no
of Building Assemblies by Means of a Guarded Hot Box
support other than itself or the substrate to which it is attached.
C 518 Test Method for Steady-State Heat Flux Measure-
3.2.6 specimen—definition of specimen as used in this
ments and Thermal Transmission Properties by Means of
2
specification shall be the same as that for prepared sample in
the Heat Flow Meter Apparatus
3.2.4.
C 739 Specification for Cellulosic Fiber (Wood-Base)
3.2.7 sprayed fiber—chemicallytreatedcellulosicmaterials,
that are pneumatically conveyed and mixed with water or
1
This specification is under the jurisdiction of ASTM Committee C16 on adhesive, or both, at the spray nozzle and become self-
Thermal Insulation and is the direct responsibility of Subcommittee C16.23 on
supporting when cured.
Blanket and Loose Fill Insulation.
Current edition approved Oct. 10, 2002. Published December 2002. Originally
published as C 1149-90. Last previous edition C 1149-98.
2 3
Annual Book of ASTM Standards, Vol 04.06. Annual Book of ASTM Standards, Vol 04.07.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
--------
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.