ASTM E1048-88(2021)
(Specification)Standard Specification for Color-Coding Pipets or Containers Coated With Anticoagulants
Standard Specification for Color-Coding Pipets or Containers Coated With Anticoagulants
ABSTRACT
This specification establishes a color-coding system to identify the anticoagulants used in coating pipets or containers not exceeding 1 mL in volume. Its purpose is to ensure that if a color code is used with an anticoagulant, all manufacturers will be encouraged, though not required, to use the same code.
SCOPE
1.1 This specification covers a system to identify the anticoagulants used in coating pipets or containers not exceeding 1 mL in volume.
1.2 The purpose of this specification is to ensure that if a color code is used with an anticoagulant, all manufacturers will be encouraged to use the same code; it is not intended to require color coding.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: E1048 −88 (Reapproved 2021)
Standard Specification for
Color-Coding Pipets or Containers Coated With
1
Anticoagulants
This standard is issued under the fixed designation E1048; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Color Code
1.1 This specification covers a system to identify the anti- 2.1 The color coding used to identify the anticoagulant used
coagulants used in coating pipets or containers not exceeding 1 in coating the pipets shall be in accordance with Table 1.
mL in volume.
2.2 Variations in the enamels used and in the methods of
1.2 The purpose of this specification is to ensure that if a application appropriate for pipets made from different types of
color code is used with an anticoagulant, all manufacturers will glass inevitably result in minor variations of color, and it is
be encouraged to use the same code; it is not intended to therefore not appropriate to specify more closely the colors
require color coding. mentioned in the table.
1.3 The values stated in SI units are to be regarded as
3. Dimensions and Permissible Variations
standard. No other units of measurement are included in this
3.1 The color code shall consist of a color band 1-3 mm
standard.
wide which shall completely encircle the pipet in a plane
1.4 This international standard was developed in accor-
perpendicular to its longitudinal axis.
dance with internationally recognized principles on standard-
3.2 The location of the color code shall not be more than 20
ization established in the Decision on Principles for the
mm from the top of the pipet.
Development of International Standards, Guides and Recom-
mendations issued by the World Trade Organization Technical
3.3 If other color code bands are used to indicate capacity,
Barriers to Trade (TBT) Committee.
they shall be 2-6 mm wide. The anticoagulant color code band
shou
...
This May Also Interest You
ABSTRACT
This specification establishes a color-coding system for indicating capacity and identifying subdivisions in disposable glass and plastic laboratory pipets with multiple graduations, but excluding disposable prothrombin and disposable micropipets. This specification intends to ensure that when color coding is utilized, all manufacturers will be encouraged to use the same color for nominal value identification. Besides the colors to be used, requirements for durability, style, and location are also presented.
SCOPE
1.1 This specification provides a system for color coding disposable pipets (glass and plastic) with multiple graduations. The color will indicate capacity and subdivisions for identification purposes.
1.2 The intent of this specification is to ensure that when color coding is utilized, all manufacturers will be encouraged to use the same color for nominal value identification.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification2 pagesEnglish languagesale 15% off
ABSTRACT
This specification establishes a color-coding system for indicating capacity and identifying subdivisions in disposable glass and plastic laboratory pipets with multiple graduations, but excluding disposable prothrombin and disposable micropipets. This specification intends to ensure that when color coding is utilized, all manufacturers will be encouraged to use the same color for nominal value identification. Besides the colors to be used, requirements for durability, style, and location are also presented.
SCOPE
1.1 This specification provides a system for color coding disposable pipets (glass and plastic) with multiple graduations. The color will indicate capacity and subdivisions for identification purposes.
1.2 The intent of this specification is to ensure that when color coding is utilized, all manufacturers will be encouraged to use the same color for nominal value identification.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification2 pagesEnglish languagesale 15% off
SIGNIFICANCE AND USE
4.1 The primary use of these test methods is testing to determine the specified mechanical properties of steel, stainless steel, and related alloy products for the evaluation of conformance of such products to a material specification under the jurisdiction of ASTM Committee A01 and its subcommittees as designated by a purchaser in a purchase order or contract.
4.1.1 These test methods may be and are used by other ASTM Committees and other standards writing bodies for the purpose of conformance testing.
4.1.2 The material condition at the time of testing, sampling frequency, specimen location and orientation, reporting requirements, and other test parameters are contained in the pertinent material specification or in a general requirement specification for the particular product form.
4.1.3 Some material specifications require the use of additional test methods not described herein; in such cases, the required test method is described in that material specification or by reference to another appropriate test method standard.
4.2 These test methods are also suitable to be used for testing of steel, stainless steel and related alloy materials for other purposes, such as incoming material acceptance testing by the purchaser or evaluation of components after service exposure.
4.2.1 As with any mechanical testing, deviations from either specification limits or expected as-manufactured properties can occur for valid reasons besides deficiency of the original as-fabricated product. These reasons include, but are not limited to: subsequent service degradation from environmental exposure (for example, temperature, corrosion); static or cyclic service stress effects, mechanically-induced damage, material inhomogeneity, anisotropic structure, natural aging of select alloys, further processing not included in the specification, sampling limitations, and measuring equipment calibration uncertainty. There is statistical variation in all aspects of mechanical testin...
SCOPE
1.1 These test methods2 cover procedures and definitions for the mechanical testing of steels, stainless steels, and related alloys. The various mechanical tests herein described are used to determine properties required in the product specifications. Variations in testing methods are to be avoided, and standard methods of testing are to be followed to obtain reproducible and comparable results. In those cases in which the testing requirements for certain products are unique or at variance with these general procedures, the product specification testing requirements shall control.
1.2 The following mechanical tests are described:
Sections
Tension
7 to 14
Bend
15
Hardness
16
Brinell
17
Rockwell
18
Portable
19
Impact
20 to 30
Keywords
32
1.3 Annexes covering details peculiar to certain products are appended to these test methods as follows:
Annex
Bar Products
Annex A1
Tubular Products
Annex A2
Fasteners
Annex A3
Round Wire Products
Annex A4
Significance of Notched-Bar Impact Testing
Annex A5
Converting Percentage Elongation of Round Specimens to
Equivalents for Flat Specimens
Annex A6
Testing Multi-Wire Strand
Annex A7
Rounding of Test Data
Annex A8
Methods for Testing Steel Reinforcing Bars
Annex A9
Procedure for Use and Control of Heat-cycle Simulation
Annex A10
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 When these test methods are referenced in a metric product specification, the yield and tensile values may be determined in inch-pound (ksi) units then converted into SI (MPa) units. The elongation determined in inch-pound gauge lengths of 2 in. or 8 in. may be report...
- Standard51 pagesEnglish languagesale 15% off
- Standard51 pagesEnglish languagesale 15% off
SIGNIFICANCE AND USE
4.1 Using the procedures and apparatus in Sections 8 and 9 and the manufacturer's instructions, pressure-tight joints as strong as the pipe itself can be made between manufacturer-recommended combinations of pipe and fittings. See Specification F1055 for performance requirements of polyethylene electrofusion fittings.
SCOPE
1.1 This practice describes procedures for making joints suitable for pressure service with polyethylene (PE) pipe and fittings by means of electrofusion joining techniques in, but not limited to, a field environment. Other suitable electrofusion joining procedures are available from various sources including fitting manufacturers. This standard does not purport to address all possible electrofusion joining procedures, or to preclude the use of qualified procedures developed by other parties that have been proven to produce reliable electrofusion joints. (Note 1)
Note 1: Reference to the manufacturer in this practice refers to the electrofusion fitting manufacturer.
1.2 The parameters and procedure are applicable only to joining polyethylene pipe and fittings (Note 2) which are intended for PE fuel gas pipe per Specification D2513 and PE potable water, sewer and industrial pipe manufactured per Specification F714, Specification D3035, Specification F2619, and AWWA C901 and C906.
Note 2: Commercially available materials classified with a thermoplastic pipe material designation code beginning with PE 14, PE 23, PE 24, PE 27, PE 33, PE 34, PE 36, and PE 46, and PE 47 in accordance with Specification D3350 and Terminology F412 are generally acceptable for electrofusion joining using this practice. Consult with the pipe or fitting manufacturer for specific compatibility information.
1.3 Parts that are within the dimensional tolerances given in present ASTM specifications are required to produce sound joints between polyethylene pipe and fittings when using the joining techniques described in this practice.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 The text of this practice references notes, footnotes, and appendices which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the practice.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard7 pagesEnglish languagesale 15% off
- 31-Aug-2023
- F17
SIGNIFICANCE AND USE
5.1 This test method is used to determine the filtering efficiency and flow rate of the filtration component of a sediment retention device, such as a silt fence, a silt barrier, or a silt curtain, for specific soil tested.
5.2 This test method may be used for the design of the filtration component of a sediment retention device to meet requirements of regulatory agencies in filtering efficiency or flow rate for the specific soil tested.
5.2.1 The designer can use this test method to determine the spacing between sediment retention devices.
5.3 This test method is intended for performance evaluation, as the results will depend on the specific soil evaluated. Unless testing with the default soil is desired, it is recommended that the user or representative perform the test to pre-approve products, as sediment retention device manufacturers are not typically equipped to handle or test soil requirements.
5.4 This test method provides a means of evaluating the filtration component of sediment retention devices with different soils under various conditions that simulate the conditions that exist in a sediment retention device installation. This test method may be used to simulate several storm events on the same sediment retention device specimen. Therefore, the number of times this test is repeated per specimen is dependent upon the user and the site conditions.
SCOPE
1.1 This test method is used to determine the filtering efficiency and the flow rate of the filtration component of a sediment retention device, such as a silt fence, silt barrier, or inlet protector.
1.1.1 The results are shown as a percentage for filtering efficiency and cubic metres per square metre per minute (m3/m2/min) or gallons per square foot per minute (gal/ft2/min) for flow rate.
1.1.2 The filtering efficiency indicates the percent of sediment removed from sediment-laden water.
1.1.3 The flow rate is the average rate of passage of the sediment-laden water through the filtration component of a sediment retention device.
1.2 This test method requires several specialized pieces of equipment, such as an integrated water sampler and an analytical balance, or a vacuum filtration system. At the client’s discretion, the test soil is either a site-specific soil or a soil that is representative of a target default gradation.
1.3 The values stated in SI units are the standard, while the inch-pound units are provided for information. The values expressed in each system may not be exact equivalents; therefore, each system must be used independently of the other, without combining values in any way.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish languagesale 15% off
- Standard5 pagesEnglish languagesale 15% off
SIGNIFICANCE AND USE
4.1 The suggestions of this guide are intended to provide proper installation materials and practices to be used during the installation of a central-vacuum system.
SCOPE
1.1 This guide demonstrates proper methods for installing a central-vacuum system.
1.2 Appendix X1 contains additional sources of information that may be helpful to the user of this guide.
1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide7 pagesEnglish languagesale 15% off
ABSTRACT
This specification covers chemical, mechanical, and metallurgical general requirements for metal injection molded (MIM) cobalt-28chromium-6molybddenum components to be used in manufacturing surgical implants. In this specification, the MIM components covered may have been densified beyond their as-sintered density by post-sinter processing. For the chemical requirements, the components supplied in this specification must conform in accordance to the chemical requirements specified herein in Table 1. The product analysis tolerances must also conform to the product tolerances presented in Table 2. The specification also enumerates the mechanical requirements for MIM components wherein the tensile properties of the MIM must conform to the mechanical properties in Table 3. The microstructural requirements and specimen preparation shall be in accordance with Guide E3 and Practice E407.
SCOPE
1.1 This specification covers chemical, mechanical, and metallurgical requirements for metal injection molded (MIM) cobalt-28chromium-6molybdenum components to be used in the manufacture of surgical implants
1.2 The MIM components covered by this specification may have been densified beyond their as-sintered density by post-sinter processing.
1.3 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification5 pagesEnglish languagesale 15% off
ABSTRACT
This specification covers general requirements for flat-rolled stainless and heat-resisting steel plate, sheet, and strip. The steel shall be made by one of the following processes: electric-arc, electric-induction, or other suitable processes. Heat and product analyses shall conform to the chemical requirements for each of the specific elements. The material shall undergo mechanical tests such as tension test, hardness test, and bend test. Special tests like intergranular corrosion test, permeability test, Charpy impact testing and tests for detrimental intermetallic phases in wrought duplex stainless steels shall be also be performed when required.
SCOPE
1.1 This specification2 covers a group of general requirements that, unless otherwise specified in the purchase order or in an individual specification, shall apply to rolled steel plate, sheet, and strip, under each of the following specifications issued by ASTM: Specifications A240/A240M, A263, A264, A265, A666, A693, A793, and A895.
1.2 In the case of conflict between a requirement of a product specification and a requirement of this specification, the product specification shall prevail. In the case of conflict between a requirement of the product specification or a requirement of this specification and a more stringent requirement of the purchase order, the purchase order shall prevail. The purchase order requirements shall not take precedence if they, in any way, violate the requirements of the product specification or this specification; for example, by waiving a test requirement or by making a test requirement less stringent.
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The SI units are shown in brackets, except that when A480M is specified, Annex A3 shall apply for the dimensional tolerances and not the bracketed SI values in Annex A2. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.4 This specification and the applicable material specifications are expressed in both inch-pound and SI units. However, unless the order specifies the applicable “M” specification designation [SI units], the material shall be furnished in inch-pound units.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification26 pagesEnglish languagesale 15% off
- Technical specification26 pagesEnglish languagesale 15% off
SIGNIFICANCE AND USE
5.1 The purpose of this guide is to provide a logical, tiered approach in the development of environmental health criteria coincident with level and effort in the research, development, testing, and evaluation of new materials for military use. Various levels of uncertainty are associated with data collected from previous stages. Following the recommendation in the guide should reduce the relative uncertainty of the data collected at each developmental stage. At each stage, a general weight of evidence qualifier shall accompany each exposure/effect relationship. They may be simple (for example, low, medium, or high confidence) or sophisticated using a numerical value for each predictor as a multiplier to ascertain relative confidence in each step of risk characterization. The specific method used will depend on the stage of development, quantity and availability of data, variation in the measurement, and general knowledge of the dataset. Since specific formulations, conditions, and use scenarios may not be known until the later stages, exposure estimates can be determined when practical (for example, Engineering and Manufacturing Development; see 6.6). Exposure data can then be used with other toxicological data collected from previous stages in a quantitative risk assessment to determine the relative degree of hazard.
5.2 Data developed from the use of this guide are designed to be consistent with criteria required in weapons and weapons system development (for example, programmatic environment, safety and occupational health evaluations, environmental assessments/environmental impact statements, toxicity clearances, and technical data sheets).
5.3 Information shall be evaluated in a flexible manner consistent with the needs of the authorizing program. This requires proper characterization of the current problem. For example, compounds may be ranked relative to the environmental criteria of the prospective alternatives, the replacement compound, and within bo...
SCOPE
1.1 This guide is intended to determine the relative environmental influence of new substances, consistent with the research and development (R&D) level of effort and is intended to be applied in a logical, tiered manner that parallels both the available funding and the stage of research, development, testing, and evaluation. Specifically, conservative assumptions, relationships, and models are recommended early in the research stage, and as the technology is matured, empirical data will be developed and used. Munition constituents are included and may include propellants, oxidizers, explosives, binders, stabilizers, metals, dyes, and other compounds used in the formulation to produce a desired effect. Munition systems range from projectiles, grenades, rockets/missiles, training simulators, to smokes and obscurants. Given the complexity of issues involved in the assessment of environmental fate and effects and the diversity of the systems used, this guide is broad in scope and not intended to address every factor that may be important in an environmental context. Rather, it is intended to reduce uncertainty at minimal cost by considering the most important factors related to human health and environmental impacts of energetic materials. This guide provides an outline for collecting data useful in a relative ranking procedure to provide the systems scientist with a sound basis for prospectively determining a selection of candidates based on environmental and human health criteria. The general principles in this guide are applicable to substances other than energetics if intended to be used in a similar manner with similar exposure profiles.
1.2 The scope of this guide includes:
1.2.1 Energetic and other new/novel materials and compositions in all stages of research, development, test and evaluation.
1.2.2 Environmental assessment, including:
1.2.2.1 Human and ecological effects of the unexploded energetics and ...
- Guide9 pagesEnglish languagesale 15% off
- Guide9 pagesEnglish languagesale 15% off
SIGNIFICANCE AND USE
5.1 This test method is designed to determine the temperature at which the Wet Blue or Wet White specimen experiences shrinkage. In this test method, shrinkage occurs as a result of hydrothermal denaturation of the collagen protein molecules which make up the fiber structure of the Wet Blue or Wet White. The shrinkage temperature of Wet Blue or Wet White is influenced by many different factors, most of which appear to affect the number and nature of crosslinking interactions between adjacent polypeptide chains of the collagen protein molecules. The value of the shrinkage temperature of Wet Blue or Wet White is commonly used as an indicator of the type of tannage or the degree of tannage, or both, of that particular Wet Blue or Wet White (especially for the more hydrothermally stable tannages such as chrome tannage).
SCOPE
1.1 This test method covers the determination of the shrinkage temperature of all types of Wet Blue and Wet White. The heating medium is water when the shrinkage temperature is at or below 98 °C. The heating medium is a glycerine-water solution when the shrinkage temperature is above 98 °C.
1.2 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard3 pagesEnglish languagesale 15% off
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.