Standard Practice for Liquid Penetrant Testing

SIGNIFICANCE AND USE
This practice establishes the basic parameters for controlling the application of the liquid penetrant method. This practice is written so it can be specified on the engineering drawing, specification, or contract. It is not a detailed how-to procedure to be used by the inspector and, therefore, must be supplemented by a detailed procedure that conforms to the requirements of this practice. Test Method E 165 contains information to help develop detailed how-to requirements.
SCOPE
1.1 This practice establishes the minimum requirements for conducting liquid penetrant examination of nonporous metal, and nonmetal components.
1.2 The penetrant examination processes described in this practice are applicable to in-process, final, and maintenance (in-service) inspections. These processes are applicable for the detection of discontinuities, such as lack of fusion, corrosion, cracks, laps, cold shuts, and porosity, that are open or connected to the surface of the component under examination.
1.3 Caution must be exercised in the usage of elevated temperature with components manufactured from thermoplastic materials. Also, some cleaners, penetrants, and developers can have a deleterious effect on nonmetallic materials such as plastics. Prior to examination, tests should be conducted to ensure that none of the cleaning or inspection materials are harmful to the components to be examined.
1.4 The values stated in inch-pound units are regarded as standard. The SI units given in brackets are for information only.
1.5 All areas of this practice may be open to agreement between the cognizant engineering organization and the supplier, or specific direction from the cognizant engineering organization.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
30-Jun-2005
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM E1417-05e1 - Standard Practice for Liquid Penetrant Testing
English language
11 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
´1
Designation:E1417–05
Standard Practice for
1
Liquid Penetrant Testing
This standard is issued under the fixed designation E1417; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1
´ NOTE—Editorial corrections were made in August 2005.
2
1. Scope 2.2 ASTM Standards:
D95 Test Method for Water in Petroleum Products and
1.1 This practice establishes the minimum requirements for
Bituminous Materials by Distillation
conducting liquid penetrant examination of nonporous metal,
D2512 Test Method for Compatibility of Materials with
and nonmetal components.
Liquid Oxygen (Impact Sensitivity Threshold and Pass-
1.2 The penetrant examination processes described in this
Fail Techniques)
practice are applicable to in-process, final, and maintenance
E165 PracticeforLiquidPenetrantExaminationforGeneral
(in-service) inspections. These processes are applicable for the
Industry
detection of discontinuities, such as lack of fusion, corrosion,
E543 Specification for Agencies Performing Nondestruc-
cracks, laps, cold shuts, and porosity, that are open or con-
tive Testing
nected to the surface of the component under examination.
E1135 Test Method for Comparing the Brightness of Fluo-
1.3 Caution must be exercised in the usage of elevated
rescent Penetrants
temperature with components manufactured from thermoplas-
E1316 Terminology for Nondestructive Examinations
tic materials. Also, some cleaners, penetrants, and developers
3
2.3 ASNT Standards:
can have a deleterious effect on nonmetallic materials such as
ANSI/ASNT-CP-189 Standard for Qualification and Certi-
plastics. Prior to examination, tests should be conducted to
fication of Nondestructive Testing Personnel
ensure that none of the cleaning or inspection materials are
SNT-TC-1A Recommended Practice for Personnel Qualifi-
harmful to the components to be examined.
cation and Certification in Nondestructive Testing
1.4 The values stated in inch-pound units are regarded as
,
4 5
2.4 Military Standards:
standard. The SI units given in brackets are for information
MIL-I-25135 Inspection Materials, Penetrant
only.
QPL-25135 Qualified Products of, Inspection Materials,
1.5 All areas of this practice may be open to agreement
Penetrant
between the cognizant engineering organization and the sup-
MIL-STD-410 Nondestructive Testing Personnel Qualifica-
plier, or specific direction from the cognizant engineering
tion and Certification
organization.
MIL-STD-792 Identification Marking Requirements for
1.6 This standard does not purport to address all of the
Special Purpose Components
safety concerns, if any, associated with its use. It is the
MIL-STD-2175 Castings Classification and Inspection of
responsibility of the user of this standard to establish appro-
QPL-AMS-2644 Qualified Products List, Inspection Mate-
priate safety and health practices and determine the applica-
rial, Penetrant
bility of regulatory limitations prior to use.
2. Referenced Documents
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
2.1 The following documents form a part of this practice to
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
the extent specified herein:
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
3
Available fromTheAmerican Society for NondestructiveTesting (ASNT), P.O.
1
This practice is under the jurisdiction of ASTM Committee E07 on Nonde- Box 28518, 1711 Arlingate Lane, Columbus, OH 43228-0518.
4
structive Testing and is the direct responsibility of Subcommittee E07.03 on Liquid Copies of specifications, standards, drawings, and publications required by
Penetrant and Magnetic Particle Methods. manufacturers in connection with specific acquisition functions should be obtained
Current edition approved Aug. 8, 2005. Published July 2005. Originally from the contracting activity or as directed by the contracting officer.
5
approved in 1991. Last previous edition approved in 1999 as E1417 – 99. DOI: AvailablefromStandardizationDocumentsOrderDesk,Bldg.4SectionD,700
10.1520/E1417-05E01. Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
´1
E1417–05
MIL-STD-45662 Calibration System Requirements 3.2.9 rounded indication—penetrant indication whose
6
2.5 ANSI/ISO/AIA Standards: length to width ratio is less than three-to-one.
ANSI/NCSL Z540-1 General
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.