ASTM F1450-12a
(Test Method)Standard Test Methods for Hollow Metal Swinging Door Assemblies for Detention and Correctional Facilities
Standard Test Methods for Hollow Metal Swinging Door Assemblies for Detention and Correctional Facilities
SIGNIFICANCE AND USE
A major concern for prison administrative officials is security barriers used in detention/correctional facilities. These test methods are designed to aid in identifying levels of physical security for swinging detention hollow metal door assemblies.
The construction and size of test doors and all hardware components are representative of the application under investigation, and are the same construction and size throughout all of the tests.
These test methods are not intended to provide a measure of resistance for a door assembly subjected to attack by corrosive agents, by high-powered rifles, explosives, sawing, or other such methods. These test methods are intended to evaluate the resistance of a door assembly to violent attacks using battering devices, such as benches, bunks, or tables; by handguns up to and including .44 magnum, UL-752 Level 3; by prying devices; by devices used to deform the door and render it inoperable; and by fires started by using mattresses, books, and other flammable materials.
The primary purpose or result of these test methods is to approximate the levels of abuse to which door assemblies are potentially subjected in the field. The desired result of its use is to help provide insurance of protection to the public, to facility administrative personnel, and to the inmates themselves.
It is recommended that detention/correctional facility administration provide adequate training, supervision, and preventative maintenance programs to enable door assemblies to function as intended throughout the expected service life.
SCOPE
1.1 These test methods cover requirements for mechanical tests, simulated service test, and testing equipment for determining the performance characteristics of swinging detention hollow metal door assemblies of various styles and types of construction for use in wall openings designed to incarcerate inmates in detention/correctional institutions.
1.2 These test methods test the capability of a swinging door assembly to prevent, delay, and frustrate escape, to limit or control access to unauthorized or secure areas, and to resist common types of vandalism.
1.3 These test methods apply primarily to detention door assemblies to and from secure areas generally found inside detention/correctional facilities, such as: day rooms, control rooms, cells, and sally ports.
1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: F1450 − 12a
Standard Test Methods for
Hollow Metal Swinging Door Assemblies for Detention and
1
Correctional Facilities
This standard is issued under the fixed designation F1450; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope F1758 Test Methods for Detention Hinges Used on
Detention-Grade Swinging Doors
1.1 These test methods cover requirements for mechanical
F1915Test Methods for Glazing for Detention Facilities
tests, simulated service test, and testing equipment for deter-
3
2.2 ANSI/NAAMM/HMMA Standard:
mining the performance characteristics of swinging detention
ANSI/NAAMM/HMMA 863Guide Specifications for De-
hollow metal door assemblies of various styles and types of
tention Security Hollow Metal Doors and Frames
construction for use in wall openings designed to incarcerate
4
inmates in detention/correctional institutions.
2.3 NFPA Standard:
252Methods of Fire Tests of Door Assemblies
1.2 Thesetestmethodstestthecapabilityofaswingingdoor
5
assembly to prevent, delay, and frustrate escape, to limit or
2.4 UL Standards:
control access to unauthorized or secure areas, and to resist
UL-10 (B)Fire Tests of Door Assemblies
common types of vandalism.
UL-10 (C)Fire Tests of Door Assemblies
UL-437Standard for Key Locks
1.3 These test methods apply primarily to detention door
UL-752 Bullet Resisting Equipment
assemblies to and from secure areas generally found inside
UL-1034 Standard for Burglary Resistant Electric Locking
detention/correctional facilities, such as: day rooms, control
Mechanisms
rooms, cells, and sally ports.
1.4 Thevaluesstatedininch-poundunitsaretoberegarded
3. Terminology
as the standard. The values given in parentheses are for
3.1 Definitions:
information only.
3.1.1 bolt—metalbarwhich,whenactuated,isprojected(or
1.5 This standard does not purport to address all of the
thrown) either horizontally or vertically into a retaining
safety concerns, if any, associated with its use. It is the
member, such as a strike plate, to prevent a door from moving
responsibility of the user of this standard to establish appro-
or opening.
priate safety and health practices and determine the applica-
3.1.2 bolt projection (or bolt throw)—distance from the
bility of regulatory limitations prior to use.
edgeofthedoororframe,attheboltcenterline,tothefarthest
2. Referenced Documents
point on the bolt in the projected position.
2
3.1.3 component—a subassembly, as distinguished from a
2.1 ASTM Standards:
F1577Test Methods for Detention Locks for Swinging part, that combines with other components to make up a total
door assembly.
Doors
F1592Test Methods for Detention Hollow Metal Vision 3.1.3.1 Discussion—The prime components of a door as-
sembly include the following: door, lock, hinges, wall, and
Systems
F1643Test Methods for Detention Sliding Door Locking door frame (includes hinge jamb, strike jamb, and header).
Device Assembly
3.1.4 detention security—assurance of the restriction of
mobilityofinmatestodesignatedareaswithinacorrectionalor
1
These test methods are under the jurisdiction of ASTM Committee F33 on detention facility.
Detention and Correctional Facilities and are the direct responsibility of Subcom-
mittee F33.02 on Physical Barriers.
CurrenteditionapprovedJune1,2012.PublishedJuly2012.Originallyapproved
3
in 1992. Last previous edition approved in 2012 as F1450–12. DOI: 10.1520/ Available fromAmerican National Standards Institute (ANSI), 25 W. 43rd St.,
F1450-12A. 4th Floor, New York, NY 10036, http://www.ansi.org.
2 4
For referenced ASTM standards, visit the ASTM website, www.astm.org, or Available from National Fire Protection Association (NFPA), 1 Batterymarch
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Park, Quincy, MA 02169-7471, http://www.nfpa.org.
5
Standards volume information, refer to the standard’s Document Summary page on Available from Underwriters Laboratories (UL), 333 Pfingsten Rd.,
the ASTM website. Northbrook, IL 60062-2096, http://www.ul.com.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
F1450 − 12a
3.1.5 door assembly—unit composed of a group of parts or 4.3 These test methods are not intended to provide a
components that make up an opening barrier for a passageway measure of resistance for a door assembly subjected to attack
through a wall. by corrosive agents, by high-powered rifles, explosives,
sawing, or other such methods. These test methods are in-
3.1.5.1 Discussion—Forthepurposeofthesetestm
...
This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:F1450–12 Designation:F1450–12a
Standard Test Methods for
Hollow Metal Swinging Door Assemblies for Detention and
1
Correctional Facilities
This standard is issued under the fixed designation F1450; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 These test methods cover requirements for mechanical tests, simulated service test, and testing equipment for determining
the performance characteristics of swinging detention hollow metal door assemblies of various styles and types of construction for
use in wall openings designed to incarcerate inmates in detention/correctional institutions.
1.2 These test methods test the capability of a swinging door assembly to prevent, delay, and frustrate escape, to limit or control
access to unauthorized or secure areas, and to resist common types of vandalism.
1.3 These test methods apply primarily to detention door assemblies to and from secure areas generally found inside
detention/correctional facilities, such as: day rooms, control rooms, cells, and sally ports.
1.4 Thevaluesstatedininch-poundunitsaretoberegardedasthestandard.Thevaluesgiveninparenthesesareforinformation
only.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
F1577 Test Methods for Detention Locks for Swinging Doors
F1592 Test Methods for Detention Hollow Metal Vision Systems
F1643 Test Methods for Detention Sliding Door Locking Device Assembly
F1758 Test Methods for Detention Hinges Used on Detention-Grade Swinging Doors
F1915 Test Methods for Glazing for Detention Facilities
3
2.2 ANSI/NAAMM/HMMA Standard:
ANSI/NAAMM/HMMA 863 Guide Specifications for Detention Security Hollow Metal Doors and Frames
4
2.3 NFPA Standard:
252 Methods of Fire Tests of Door Assemblies
5
2.4 UL Standards:
UL-10 (B) Fire Tests of Door Assemblies
UL-10 (C) Fire Tests of Door Assemblies
UL-437 Standard for Key Locks
UL-752 Bullet Resisting Equipment
UL-1034 Standard for Burglary Resistant Electric Locking Mechanisms
3. Terminology
3.1 Definitions:
3.1.1 bolt—metal bar which, when actuated, is projected (or thrown) either horizontally or vertically into a retaining member,
such as a strike plate, to prevent a door from moving or opening.
1
These test methods are under the jurisdiction ofASTM Committee F33 on Detention and Correctional Facilities and are the direct responsibility of Subcommittee F33.02
on Physical Barriers.
Current edition approved Jan.June 1, 2012. Published AprilJuly 2012. Originally approved in 1992. Last previous edition approved in 20102012 as F1450 – 102. DOI:
10.1520/F1450-12A.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http://www.ansi.org.
4
Available from National Fire Protection Association (NFPA), 1 Batterymarch Park, Quincy, MA 02169-7471, http://www.nfpa.org.
5
Available from Underwriters Laboratories (UL), 333 Pfingsten Rd., Northbrook, IL 60062-2096, http://www.ul.com.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
F1450–12a
3.1.2 bolt projection (or bolt throw)—distance from the edge of the door or frame, at the bolt center line, to the farthest point
on the bolt in the projected position.
3.1.3 component—a subassembly, as distinguished from a part, that combines with other components to make up a total door
assembly.
3.1.3.1 Discussion—The prime components of a door assembly include the following: door, lock, hinges, wall, and door frame
(includes hinge jamb, strike jamb, and header).
3.1.4 detention security—assurance of the restriction of mobility of inmates to designated areas within a correctional or
detention facility.
3.1.5 door assembly—unit composed of a group of parts or compon
...