Standard Test Method for Nonvolatile Matter of Agricultural Adjuvant Solutions by Thermogravimetry

SIGNIFICANCE AND USE
5.1 This test method is intended for use in quality control, material screening, and related problem solving where a nonvolatile content is desired or a comparison can be made with a known material of the same type.  
5.2 The parameters described may be altered to suit a particular analysis, provided the changes are noted in the report.
SCOPE
1.1 This test method covers the determination of the non-volatile matter of agricultural tank mix adjuvant solutions by thermogravimetry.  
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Historical
Publication Date
31-Oct-2017
Current Stage
Ref Project

Buy Standard

Standard
ASTM E2043-99(2017) - Standard Test Method for Nonvolatile Matter of Agricultural Adjuvant Solutions by Thermogravimetry
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM E2043-99(2017) - Standard Test Method for Nonvolatile Matter of Agricultural Adjuvant Solutions by Thermogravimetry
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: E2043 − 99 (Reapproved 2017)
Standard Test Method for
Nonvolatile Matter of Agricultural Adjuvant Solutions by
1
Thermogravimetry
This standard is issued under the fixed designation E2043; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 3.1.1 nonvolatile matter, n—the matter remaining after heat-
ing an agricultural adjuvant solution at 50 6 2.5°C for 16 h.
1.1 This test method covers the determination of the non-
volatile matter of agricultural tank mix adjuvant solutions by
4. Summary of Test Method
thermogravimetry.
4.1 This test method is an empirical technique using ther-
1.2 The values stated in SI units are to be regarded as
mogravimetry in which the mass of an agricultural adjuvant,
standard. No other units of measurement are included in this
heated at a controlled rate in an appropriate environment, is
standard.
recorded as a function of time and temperature. Nonvolatile
matteristhemassremainingafterheatingataspecifictimeand
1.3 This standard does not purport to address all of the
temperature.
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro-
5. Significance and Use
priate safety, health, and environmental practices and deter-
5.1 This test method is intended for use in quality control,
mine the applicability of regulatory limitations prior to use.
material screening, and related problem solving where a
1.4 This international standard was developed in accor-
nonvolatile content is desired or a comparison can be made
dance with internationally recognized principles on standard-
with a known material of the same type.
ization established in the Decision on Principles for the
Development of International Standards, Guides and Recom-
5.2 The parameters described may be altered to suit a
mendations issued by the World Trade Organization Technical
particular analysis, provided the changes are noted in the
Barriers to Trade (TBT) Committee.
report.
6. Apparatus
2. Referenced Documents
2 6.1 Aluminum Weighing Dishes, flat bottom, 70 mL capac-
2.1 ASTM Standards:
ity.
E473 Terminology Relating to Thermal Analysis and Rhe-
ology 6.2 Analytical Balance, with a sensitivity of 0.01 g.
E1131 Test Method for CompositionalAnalysis by Thermo-
6.3 Desiccator.
gravimetry
6.4 Drying Oven, gravity convection-type, capable of main-
E1519 Terminology Relating to Agricultural Tank Mix Ad-
taining a temperature of 50 6 2.5°C. If many determinations of
juvants
solvent-based adjuvants are being made at the same time, an
explosion-proof oven should be used.
3. Terminology
7. Procedure
3.1 Definitions:
7.1 Bring the material to be tested to equilibrium tempera-
ture at 25 6 5°C.
1
This test method is under the jurisdiction of ASTM Committee E35 on
7.2 Dry two flat-bottomed aluminum weighing dishes in an
Pesticides, Antimicrobials, and Alternative Control Agents and is the direct
oven at 50 6 2.5°C for 1 h. Allow the dishes
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: E2043 − 99 (Reapproved 2012) E2043 − 99 (Reapproved 2017)
Standard Test Method for
Nonvolatile Matter of Agricultural Adjuvant Solutions by
1
Thermogravimetry
This standard is issued under the fixed designation E2043; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This test method covers the determination of the non-volatile matter of agricultural tank mix adjuvant solutions by
thermogravimetry.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
E473 Terminology Relating to Thermal Analysis and Rheology
E1131 Test Method for Compositional Analysis by Thermogravimetry
E1519 Terminology Relating to Agricultural Tank Mix Adjuvants
3. Terminology
3.1 Definitions:
3.1.1 nonvolatile matter, n—the matter remaining after heating an agricultural adjuvant solution at 50 6 2.5°C for 16 h.
4. Summary of Test Method
4.1 This test method is an empirical technique using thermogravimetry in which the mass of an agricultural adjuvant, heated
at a controlled rate in an appropriate environment, is recorded as a function of time and temperature. Nonvolatile matter is the mass
remaining after heating at a specific time and temperature.
5. Significance and Use
5.1 This test method is intended for use in quality control, material screening, and related problem solving where a nonvolatile
content is desired or a comparison can be made with a known material of the same type.
5.2 The parameters described may be altered to suit a particular analysis, provided the changes are noted in the report.
6. Apparatus
6.1 Aluminum Weighing Dishes, flat bottom, 70 mL capacity.
6.2 Analytical Balance, with a sensitivity of 0.01 g.
6.3 Desiccator.
1
This test method is under the jurisdiction of ASTM Committee E35 on Pesticides, Antimicrobials, and Alternative Control Agents and is the direct responsibility of
Subcommittee E35.22 on Pesticide Formulations and Delivery Systems.
Current edition approved Oct. 1, 2012Nov. 1, 2017. Published October 2012December 2017. Originally approved in 1999. Last previous edition approved in 20062012
as E2043 – 99 (2006).(2012). DOI: 10.1520/E20
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.