Standard Specification for Evaluating Accelerated Aging Performance of Environmentally Controlled Dynamic Glazings

ABSTRACT
This specification provides a basis for evaluating the accelerated aging performance of environmentally controlled dynamic glazings (ECDG) in monolithic glass, monolithic laminated glass, or pre-assembled, permanently sealed insulating glass units that are constructed with glass and fabricated for vision glass areas for use in buildings, such as sliding doors, windows, skylights, and exterior wall systems. ECDG is the glazing material installed in a prepared opening of a building whose visible light transmittance or near infrared light transmittance properties, or both, can be changed reversibly by exposure to changing environmental conditions such as temperature and sunlight intensity. This specification also covers ECDG devices in pre-assembled insulating glass units with capillary tubes intentionally left open, but does not apply to other types of dynamic glazing which require an electrical stimulus to change light transmittance, such as electrochromic glazings.
This specification prescribes the performance requirements and test methods for ECDG, as well as specimen preparation, qualification, and reporting requirements.
SCOPE
1.1 This specification is applicable to environmentally controlled dynamic glazings (ECDG) whose visible light transmittance or near infrared light transmittance properties, or both, can be changed reversibly by exposure to changing environmental conditions such as temperature and sunlight intensity. This includes thermochromic and thermotropic glazing, but currently excludes photochromic glazings as neither Test Method E3119 nor this specification provide a procedure to access multiple states of photochromic glazing specimens.  
1.2 This specification does not apply to other types of dynamic glazing which require an electrical stimulus to change light transmittance, such as electrochromic glazings.  
1.3 This specification covers environmentally controlled dynamic glazing (ECDG) in monolithic glass, monolithic laminated glass, or pre-assembled, permanently sealed insulating glass units with one or more cavities in which at least one lite is an ECDG (which may be in the form of a laminated lite or a single pane with coatings or film applied). This specification is also applicable to ECDG devices in pre-assembled insulating glass units with capillary tubes intentionally left open. As applicable, this specification also requires conformance to Specification E2190.  
1.4 This specification is applicable only to monolithic glass, monolithic laminated glass, and sealed insulating glass units that are constructed with glass and fabricated for vision glass areas for use in buildings, such as sliding doors, windows, skylights, and exterior wall systems.  
1.5 Qualification under this specification is intended to provide a basis for evaluating the aging performance of environmentally controlled dynamic glazing in monolithic glass, monolithic laminated glass, and sealed insulating glass units.  
1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
30-Jun-2019
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM E3120-19 - Standard Specification for Evaluating Accelerated Aging Performance of Environmentally Controlled Dynamic Glazings
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM E3120-19 - Standard Specification for Evaluating Accelerated Aging Performance of Environmentally Controlled Dynamic Glazings
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation:E3120 −19
Standard Specification for
Evaluating Accelerated Aging Performance of
1
Environmentally Controlled Dynamic Glazings
This standard is issued under the fixed designation E3120; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 1.6 The values stated in SI units are to be regarded as
standard. No other units of measurement are included in this
1.1 This specification is applicable to environmentally con-
standard.
trolleddynamicglazings(ECDG)whosevisiblelighttransmit-
1.7 This standard does not purport to address all of the
tance or near infrared light transmittance properties, or both,
safety concerns, if any, associated with its use. It is the
can be changed reversibly by exposure to changing environ-
responsibility of the user of this standard to establish appro-
mental conditions such as temperature and sunlight intensity.
priate safety, health, and environmental practices and deter-
This includes thermochromic and thermotropic glazing, but
mine the applicability of regulatory limitations prior to use.
currently excludes photochromic glazings as neither Test
1.8 This international standard was developed in accor-
Method E3119 nor this specification provide a procedure to
dance with internationally recognized principles on standard-
access multiple states of photochromic glazing specimens.
ization established in the Decision on Principles for the
1.2 This specification does not apply to other types of
Development of International Standards, Guides and Recom-
dynamicglazingwhichrequireanelectricalstimulustochange
mendations issued by the World Trade Organization Technical
light transmittance, such as electrochromic glazings.
Barriers to Trade (TBT) Committee.
1.3 This specification covers environmentally controlled
2. Referenced Documents
dynamic glazing (ECDG) in monolithic glass, monolithic
2
laminated glass, or pre-assembled, permanently sealed insulat-
2.1 ASTM Standards:
ing glass units with one or more cavities in which at least one C162Terminology of Glass and Glass Products
lite is an ECDG (which may be in the form of a laminated lite
C1036Specification for Flat Glass
or a single pane with coatings or film applied). This specifica- C1048Specification for Heat-Strengthened and Fully Tem-
tion is also applicable to ECDG devices in pre-assembled pered Flat Glass
insulating glass units with capillary tubes intentionally left C1172Specification for Laminated Architectural Flat Glass
open. As applicable, this specification also requires confor- E631Terminology of Building Constructions
mance to Specification E2190. E2190Specification for Insulating Glass Unit Performance
and Evaluation
1.4 Thisspecificationisapplicableonlytomonolithicglass,
E3119Test Method for Accelerated Aging of Environmen-
monolithic laminated glass, and sealed insulating glass units
tally Controlled Dynamic Glazing
that are constructed with glass and fabricated for vision glass
G113Terminology Relating to Natural andArtificialWeath-
areas for use in buildings, such as sliding doors, windows,
ering Tests of Nonmetallic Materials
skylights, and exterior wall systems.
1.5 Qualification under this specification is intended to 3. Terminology
provide a basis for evaluating the aging performance of
3.1 Definitions—For definitions of terms found in this
environmentally controlled dynamic glazing in monolithic
specification, refer to Terminologies C162, E631, and G113.
glass, monolithic laminated glass, and sealed insulating glass
3.2 Definitions of Terms Specific to This Standard:
units.
3.2.1 environmentally controlled dynamic glazing, n—in a
preparedopeningofabuilding,theglazingmaterialinstalledin
1
This specification is under the jurisdiction of ASTM Committee E06 on
Performance of Buildings and is the direct responsibility of Subcommittee E06.22
2
on Durability Performance of Building Constructions. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved July 1, 2019. Published September 2019. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
approved in 2017. Last previous edition approved in 2017 as E3120–17. DOI: Standards volume information, refer to the standard’s Document Summary page on
10.1520/E3120–19. the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 --------------------
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: E3120 − 17 E3120 − 19
Standard Specification for
Evaluating Accelerated Aging Performance of
1
Environmentally Controlled Dynamic Glazings
This standard is issued under the fixed designation E3120; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This specification is applicable to environmentally controlled dynamic glazings (ECDG) whose visible light transmittance
or near infrared light transmittance properties, or both, can be changed reversibly by exposure to changing environmental
conditions such as temperature and sunlight intensity. This includes thermochromic and thermotropic glazing, but currently
excludes photochromic glazings as neither Test Method E3119 nor this specification provide a procedure to access multiple states
of photochromic glazing specimens.
1.2 This specification does not apply to other types of dynamic glazing which require an electrical stimulus to change light
transmittance, such as electrochromic glazings.
1.3 This specification covers environmentally controlled dynamic glazing (ECDG) in monolithic glass, monolithic laminated
glass, or pre-assembled, permanently sealed insulating glass units with one or more cavities in which at least one lite is an ECDG
(which may be in the form of a laminated lite or a single pane with coatings or film applied). This specification is also applicable
to ECDG devices in pre-assembled insulating glass units with capillary tubes intentionally left open. As applicable, this
specification also requires conformance to Specification E2190.
1.4 This specification is applicable only to monolithic glass, monolithic laminated glass, and sealed insulating glass units that
are constructed with glass and fabricated for vision glass areas for use in buildings, such as sliding doors, windows, skylights, and
exterior wall systems.
1.5 Qualification under this specification is intended to provide a basis for evaluating the aging performance of environmentally
controlled dynamic glazing in monolithic glass, monolithic laminated glass, and sealed insulating glass units.
1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of
regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
C162 Terminology of Glass and Glass Products
C1036 Specification for Flat Glass
C1048 Specification for Heat-Strengthened and Fully Tempered Flat Glass
C1172 Specification for Laminated Architectural Flat Glass
E631 Terminology of Building Constructions
E2190 Specification for Insulating Glass Unit Performance and Evaluation
E3119 Test Method for Accelerated Aging of Environmentally Controlled Dynamic Glazing
1
This specification is under the jurisdiction of ASTM Committee E06 on Performance of Buildings and is the direct responsibility of Subcommittee E06.22 on Durability
Performance of Building Constructions.
Current edition approved Sept. 1, 2017July 1, 2019. Published December 2017September 2019. Originally approved in 2017. Last previous edition approved in 2017 as
E3120–17. DOI: 10.1520/E3120-17.10.1520/E3120–19.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E3120 − 19
G113 Terminology Relating to Natural and Artificial Weathering Tests of Nonmetallic Materials
3. Terminology
3.1 Definitions—For definitions of terms found in this specification, refer to
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.