ASTM C90-14
(Specification)Standard Specification for Loadbearing Concrete Masonry Units
Standard Specification for Loadbearing Concrete Masonry Units
ABSTRACT
This specification covers hollow and solid concrete masonry units made from hydraulic cement, water, and mineral aggregates with or without the inclusion of other materials. There are three classes of concrete masonry units: normal weight, medium weight, and lightweight. These units are suitable for both loadbearing and nonloadbearing applications. Concrete masonry units shall be made from lightweight or normal weight aggregates, or both.
SCOPE
1.1 This specification covers hollow and solid (see 5.3 and 5.4) concrete masonry units made from hydraulic cement, water, and mineral aggregates with or without the inclusion of other materials. There are three classes of concrete masonry units: (1) normal weight, (2) medium weight, and (3) lightweight. These units are suitable for both loadbearing and nonloadbearing applications.
1.2 Concrete masonry units covered by this specification are made from lightweight or normal weight aggregates, or both.Note 1—The requirements of this specification have been researched, evaluated, and established for over a century, resulting in the physical properties and attributes defined here. These requirements are uniquely and solely applicable to concrete masonry units manufactured on equipment using low or zero slump concrete and the constituent materials defined herein. Many performance attributes of concrete masonry units are indirectly accounted for, or inherently reflected within, the requirements of this specification without direct measurement, assessment, or evaluation. Applying the requirements of this specification to products that may be similar in appearance, use, or nature to those covered by this specification may not address all pertinent physical properties necessary to ensure performance or serviceability of the resulting construction in real-world applications under typical exposure environments. Products manufactured using alternative materials, manufacturing methods, or curing processes not covered by this specification should not be evaluated solely using the requirements in this specification; however, developers of new products can consider the property requirements of this specification as a beginning benchmark for unit performance. It is reasonable to test new products for system performance as well as unit performance.
1.3 The text of this specification references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.Note 2—When particular features are desired such as surface textures for appearance or bond, finish, color, or particular properties such as density classification, higher compressive strength, fire resistance, thermal performance or acoustical performance, these features should be specified separately by the purchaser. Suppliers should be consulted as to the availability of units having the desired features.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C90 −14
StandardSpecification for
1
Loadbearing Concrete Masonry Units
This standard is issued under the fixed designation C90; the number immediately following the designation indicates the year of original
adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscript
epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
for appearance or bond, finish, color, or particular properties such as
1. Scope*
density classification, higher compressive strength, fire resistance, thermal
1.1 This specification covers hollow and solid (see 5.3 and
performance or acoustical performance, these features should be specified
5.4) concrete masonry units made from hydraulic cement,
separately by the purchaser. Suppliers should be consulted as to the
availability of units having the desired features.
water, and mineral aggregates with or without the inclusion of
other materials. There are three classes of concrete masonry
2. Referenced Documents
units: (1) normal weight, (2) medium weight, and (3) light-
weight. These units are suitable for both loadbearing and 2
2.1 ASTM Standards:
nonloadbearing applications.
C33 Specification for Concrete Aggregates
1.2 Concretemasonryunitscoveredbythisspecificationare C140 Test Methods for Sampling and Testing Concrete
made from lightweight or normal weight aggregates, or both.
Masonry Units and Related Units
NOTE 1—The requirements of this specification have been researched,
C150 Specification for Portland Cement
evaluated, and established for over a century, resulting in the physical
C331 Specification for LightweightAggregates for Concrete
properties and attributes defined here. These requirements are uniquely
Masonry Units
and solely applicable to concrete masonry units manufactured on equip-
C426 Test Method for Linear Drying Shrinkage of Concrete
ment using low or zero slump concrete and the constituent materials
definedherein.Manyperformanceattributesofconcretemasonryunitsare Masonry Units
indirectly accounted for, or inherently reflected within, the requirements
C595 Specification for Blended Hydraulic Cements
of this specification without direct measurement, assessment, or evalua-
C618 Specification for Coal Fly Ash and Raw or Calcined
tion.Applying the requirements of this specification to products that may
Natural Pozzolan for Use in Concrete
be similar in appearance, use, or nature to those covered by this
C979 Specification for Pigments for Integrally Colored Con-
specificationmaynotaddressallpertinentphysicalpropertiesnecessaryto
ensure performance or serviceability of the resulting construction in crete
real-world applications under typical exposure environments. Products
C989 Specification for Slag Cement for Use in Concrete and
manufactured using alternative materials, manufacturing methods, or
Mortars
curing processes not covered by this specification should not be evaluated
C1157 Performance Specification for Hydraulic Cement
solely using the requirements in this specification; however, developers of
C1232 Terminology of Masonry
new products can consider the property requirements of this specification
as a beginning benchmark for unit performance. It is reasonable to test
C1240 Specification for Silica Fume Used in Cementitious
new products for system performance as well as unit performance.
Mixtures
1.3 The text of this specification references notes and C1314 Test Method for Compressive Strength of Masonry
footnotes which provide explanatory material. These notes and Prisms
footnotes (excluding those in tables and figures) shall not be E519 Test Method for Diagonal Tension (Shear) in Masonry
considered as requirements of the standard. Assemblages
E72 Test Methods of Conducting Strength Tests of Panels
1.4 The values stated in inch-pound units are to be regarded
for Building Construction
as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only
3. Terminology
and are not considered standard.
3.1 Terminology defined in Terminology C1232 shall apply
NOTE 2—When particular features are desired such as surface textures
for this specification.
1
This specification is under the jurisdiction of ASTM Committee C15 on
Manufactured Masonry Units and is the direct responsibility of Subcommittee
2
C15.03 on Concrete Masonry Units and Related Units. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved Feb. 1, 2014. Published February 2014. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
approved in 1931. Last previous edition approved in 2013 as C90 – 13. DOI: Standards volume information, refer to the stand
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C90 − 13 C90 − 14
Standard Specification for
1
Loadbearing Concrete Masonry Units
This standard is issued under the fixed designation C90; the number immediately following the designation indicates the year of original
adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript
epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope*
1.1 This specification covers hollow and solid (see 5.3 and 5.4) concrete masonry units made from hydraulic cement, water, and
mineral aggregates with or without the inclusion of other materials. There are three classes of concrete masonry units: (1) normal
weight, (2) medium weight, and (3) lightweight. These units are suitable for both loadbearing and nonloadbearing applications.
1.2 Concrete masonry units covered by this specification are made from lightweight or normal weight aggregates, or both.
NOTE 1—The requirements of this specification have been researched, evaluated, and established for over a century, resulting in the physical properties
and attributes defined here. These requirements are uniquely and solely applicable to concrete masonry units manufactured on equipment using low or
zero slump concrete and the constituent materials defined herein. Many performance attributes of concrete masonry units are indirectly accounted for,
or inherently reflected within, the requirements of this specification without direct measurement, assessment, or evaluation. Applying the requirements
of this specification to products that may be similar in appearance, use, or nature to those covered by this specification may not address all pertinent
physical properties necessary to ensure performance or serviceability of the resulting construction in real-world applications under typical exposure
environments. Products manufactured using alternative materials, manufacturing methods, or curing processes not covered by this specification should
not be evaluated solely using the requirements in this specification; however, developers of new products can consider the property requirements of this
specification as a beginning benchmark for unit performance. It is reasonable to test new products for system performance as well as unit performance.
1.3 The text of this specification references notes and footnotes which provide explanatory material. These notes and footnotes
(excluding those in tables and figures) shall not be considered as requirements of the standard.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
NOTE 2—When particular features are desired such as surface textures for appearance or bond, finish, color, or particular properties such as density
classification, higher compressive strength, fire resistance, thermal performance or acoustical performance, these features should be specified separately
by the purchaser. Suppliers should be consulted as to the availability of units having the desired features.
2. Referenced Documents
2
2.1 ASTM Standards:
C33 Specification for Concrete Aggregates
C140 Test Methods for Sampling and Testing Concrete Masonry Units and Related Units
C150 Specification for Portland Cement
C331 Specification for Lightweight Aggregates for Concrete Masonry Units
C426 Test Method for Linear Drying Shrinkage of Concrete Masonry Units
C595 Specification for Blended Hydraulic Cements
C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete
C979 Specification for Pigments for Integrally Colored Concrete
C989 Specification for Slag Cement for Use in Concrete and Mortars
C1157 Performance Specification for Hydraulic Cement
C1232 Terminology of Masonry
C1240 Specification for Silica Fume Used in Cementitious Mixtures
C1314 Test Method for Compressive Strength of Masonry Prisms
1
This specification is under the jurisdiction of ASTM Committee C15 on Manufactured Masonry Units and is the direct responsibility of Subcommittee C15.03 on
Concrete Masonry Units and Related Units.
Current edition approved June 1, 2013Feb. 1, 2014. Published June 2013February 2014. Originally approved in 1931. Last previous edition approved in 20122013 as
C90 – 12.C90 – 13. DOI: 10.1520/C0090-13.10.1520/C0090-14.
2
For referenced ASTM standards, visit the ASTM website, ww
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.