Standard Test Method for Stability of Perchloroethylene with Copper

SIGNIFICANCE AND USE
4.1 This test method is to be used as a guide in selecting or eliminating certain grades of perchloroethylene used for drycleaning fabrics or degreasing metal parts.
SCOPE
1.1 This test method covers the evaluation of the corrosiveness to copper metal by perchloroethylene.  
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
30-Apr-2022
Current Stage
Ref Project

Buy Standard

Standard
ASTM D3316-06(2022) - Standard Test Method for Stability of Perchloroethylene with Copper
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: D3316 − 06 (Reapproved 2022)
Standard Test Method for
Stability of Perchloroethylene with Copper
This standard is issued under the fixed designation D3316; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 5. Apparatus
1.1 This test method covers the evaluation of the corrosive- 5.1 Flask, 300 mL, 24/40 standard-taper joint.
ness to copper metal by perchloroethylene.
5.2 Soxhlet Extractor, 30 mm inside diameter, 24/40
1.2 The values stated in SI units are to be regarded as standard-taper bottom joint, 34/45 standard-taper upper joint.
standard. No other units of measurement are included in this
5.3 Allihn Condenser, bulb type, 34/45 standard-taper bot-
standard.
tom joint.
1.3 This standard does not purport to address all of the
5.4 Bottle, wide-mouth, 8 oz.
safety concerns, if any, associated with its use. It is the
5.5 Funnel, 8 mm outside diameter stem, 35 mm diameter
responsibility of the user of this standard to establish appro-
opening.
priate safety, health, and environmental practices and deter-
mine the applicability of regulatory limitations prior to use.
5.6 Heater, variable control.
1.4 This international standard was developed in accor-
5.7 Light Bulb, 100 W.
dance with internationally recognized principles on standard-
5.8 Beaker, 400 mL.
ization established in the Decision on Principles for the
Development of International Standards, Guides and Recom-
5.9 Analytical Balance.
mendations issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee.
6. Reagents and Materials
6.1 Purity of Reagents—Reagent grade chemicals shall be
2. Referenced Documents
used in all tests. Unless otherwise indicated, it is intended that
2.1 ASTM Standards:
all reagents shall conform to the specifications of the Commit-
E200 Practice for Preparation, Standardization, and Storage
tee on Analytical Reagents of the American Chemical Society,
of Standard and Reagent Solutions for ChemicalAnalysis
where such specifications are available. Other grades may be
used, provided it is first ascertained that the reagent is of
3. Summary of Test Method
sufficiently high purity to permit its use without lessening the
3.1 Clean copper strips are subjected to the action of liquid accuracy of the determination.
and vapor phases of boiling perchloroethylene for 72 h in the
6.2 Purity of Water—Unless otherwise indicated, references
presence of light. Weight loss of copper strips and acid
to water shall be understood to mean distilled water or water of
formation are determined at the end of the test period.
equal purity.
6.3 Acetone, practical grade.
4. Significance and Use
6.4 Copper, electrolytic foil, 0.05 mm thick. Cut three
4.1 This test method is to be used as a guide in selecting or
copper strips, 20 mm by 75 mm. Immerse the strips in
eliminating certain grades of perchloroethylene used for dry-
cleaning fabrics or degreasing metal parts. concentrated HCl until the surface is bright and free of tarnish.
Scribe consecutive identification numbers on the strips. Rinse
thoroughly in running water and dry with a towel. Weigh the
This test method is under the jurisdiction of ASTM Committee D26 on
strips to the nearest 0.1 mg on an analytical balance.
Halogenated Organic Solvents and Fire Extinguishing Agents and is the direct
responsibility of Subcommittee D26.04 on Test Methods.
Current edition approved May 1, 2022. Published May 2022. Originally
approved in 1974. Last previous edition approved in 2016 as D3316-06(2016). DOI: Reagent Chemicals, American Chemical Society Specifications, American
10.1520/D3316-06R22. Chemical Society, Washington, DC. For suggestions on the testing of reagents not
For referenced ASTM standards, visit the ASTM website, www.astm.org, or listed by the American Chemical Society, see Analar Standards for Laboratory
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Chemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeia
Standards volume information, refer to the standard’s Document Summary page on and National Formulary, U.S. Pharmacopeial Convention, Inc. (USP), Rockville,
the ASTM website. MD.
Copyright © ASTM International, 100 B
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.