Standard Practice for Fluorescent Liquid Penetrant Testing Using the Hydrophilic Post-Emulsification Process

SIGNIFICANCE AND USE
5.1 Liquid penetrant examination methods indicate the presence, location, and, to a limited extent, the nature and magnitude of the detected discontinuities. This practice is normally used for production examination of critical components, where reproducibility is essential. More procedural controls and processing steps are required than with other processes.
SCOPE
1.1 This practice covers procedures for fluorescent penetrant examination utilizing the hydrophilic post-emulsification process. It is a nondestructive testing method for detecting discontinuities that are open to the surface such as cracks, seams, laps, cold shuts, laminations, isolated porosity, through leaks, or lack of fusion and is applicable to in-process, final, and maintenance examination. It can be effectively used in the examination of nonporous, metallic materials, both ferrous and nonferrous, and of nonmetallic materials such as glazed or fully densified ceramics and certain nonporous plastics and glass.  
1.2 This practice also provides a reference:  
1.2.1 By which a fluorescent penetrant examination hydrophilic post-emulsification process recommended or required by individual organizations can be reviewed to ascertain their applicability and completeness.  
1.2.2 For use in the preparation of process specifications dealing with the fluorescent penetrant examination of materials and parts using the hydrophilic post-emulsification process. Agreement by the purchaser and the manufacturer regarding specific techniques is strongly recommended.  
1.2.3 For use in the organization of the facilities and personnel concerned with the liquid penetrant examination.  
1.3 This practice does not indicate or suggest standards for evaluation of the indications obtained. It should be pointed out, however, that indications must be interpreted or classified and then evaluated. For this purpose there must be a separate code or specification or a specific agreement to define the type, size, location, and direction of indications considered acceptable, and those considered unacceptable.  
1.3.1 The user is encouraged to use materials and processing parameters necessary to detect conditions of a type or severity which could affect the evaluation of the product.  
1.4 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.5 All areas of this practice may be open to agreement between the cognizant engineering organization and the supplier, or specific direction from the cognizant engineering organization.  
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
30-Jun-2021
Current Stage
Ref Project

Buy Standard

Standard
ASTM E1210-21 - Standard Practice for Fluorescent Liquid Penetrant Testing Using the Hydrophilic Post-Emulsification Process
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM E1210-21 - Standard Practice for Fluorescent Liquid Penetrant Testing Using the Hydrophilic Post-Emulsification Process
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation:E1210 −21
Standard Practice for
Fluorescent Liquid Penetrant Testing Using the Hydrophilic
1
Post-Emulsification Process
This standard is issued under the fixed designation E1210; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 1.4 Units—The values stated in inch-pound units are to be
regarded as standard. The values given in parentheses are
1.1 This practice covers procedures for fluorescent pen-
mathematical conversions to SI units that are provided for
etrantexaminationutilizingthehydrophilicpost-emulsification
information only and are not considered standard.
process. It is a nondestructive testing method for detecting
1.5 All areas of this practice may be open to agreement
discontinuities that are open to the surface such as cracks,
between the cognizant engineering organization and the
seams, laps, cold shuts, laminations, isolated porosity, through
supplier, or specific direction from the cognizant engineering
leaks, or lack of fusion and is applicable to in-process, final,
organization.
and maintenance examination. It can be effectively used in the
examination of nonporous, metallic materials, both ferrous and
1.6 This standard does not purport to address all of the
nonferrous, and of nonmetallic materials such as glazed or
safety concerns, if any, associated with its use. It is the
fully densified ceramics and certain nonporous plastics and
responsibility of the user of this standard to establish appro-
glass.
priate safety, health, and environmental practices and deter-
mine the applicability of regulatory limitations prior to use.
1.2 This practice also provides a reference:
1.7 This international standard was developed in accor-
1.2.1 By which a fluorescent penetrant examination hydro-
dance with internationally recognized principles on standard-
philicpost-emulsificationprocessrecommendedorrequiredby
ization established in the Decision on Principles for the
individual organizations can be reviewed to ascertain their
Development of International Standards, Guides and Recom-
applicability and completeness.
mendations issued by the World Trade Organization Technical
1.2.2 For use in the preparation of process specifications
Barriers to Trade (TBT) Committee.
dealing with the fluorescent penetrant examination of materials
and parts using the hydrophilic post-emulsification process.
2. Referenced Documents
Agreement by the purchaser and the manufacturer regarding
2
2.1 ASTM Standards:
specific techniques is strongly recommended.
D129 Test Method for Sulfur in Petroleum Products (Gen-
1.2.3 For use in the organization of the facilities and
eral High Pressure Decomposition Device Method)
personnel concerned with the liquid penetrant examination.
D516 Test Method for Sulfate Ion in Water
1.3 This practice does not indicate or suggest standards for
D808 Test Method for Chlorine in New and Used Petroleum
evaluationoftheindicationsobtained.Itshouldbepointedout,
Products (High Pressure Decomposition Device Method)
however, that indications must be interpreted or classified and
D1552 Test Method for Sulfur in Petroleum Products by
then evaluated. For this purpose there must be a separate code
High Temperature Combustion and Infrared (IR) Detec-
or specification or a specific agreement to define the type, size,
tion or Thermal Conductivity Detection (TCD)
location, and direction of indications considered acceptable,
E165/E165M Practice for Liquid Penetrant Testing for Gen-
and those considered unacceptable.
eral Industry
1.3.1 Theuserisencouragedtousematerialsandprocessing
E433 Reference Photographs for Liquid Penetrant Inspec-
parameters necessary to detect conditions of a type or severity
tion
which could affect the evaluation of the product.
E543 Specification forAgencies Performing Nondestructive
Testing
E1316 Terminology for Nondestructive Examinations
1
This practice is under the jurisdiction of ASTM Committee E07 on Nonde-
structive Testing and is the direct responsibility of Subcommittee E07.03 on Liquid
2
Penetrant and Magnetic Particle Methods. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved July 1, 2021. Published August 2021. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
approved in 1987. Last previous edition approved in 2016 as E1210 – 16. DOI: Standards volume information, refer to the standard’s Document Summary page on
10.1520/E1210-21.
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: E1210 − 16 E1210 − 21
Standard Practice for
Fluorescent Liquid Penetrant Testing Using the Hydrophilic
1
Post-Emulsification Process
This standard is issued under the fixed designation E1210; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This practice covers procedures for fluorescent penetrant examination utilizing the hydrophilic post-emulsification process. It
is a nondestructive testing method for detecting discontinuities that are open to the surface such as cracks, seams, laps, cold shuts,
laminations, isolated porosity, through leaks, or lack of fusion and is applicable to in-process, final, and maintenance examination.
It can be effectively used in the examination of nonporous, metallic materials, both ferrous and nonferrous, and of nonmetallic
materials such as glazed or fully densified ceramics and certain nonporous plastics and glass.
1.2 This practice also provides a reference:
1.2.1 By which a fluorescent penetrant examination hydrophilic post-emulsification process recommended or required by
individual organizations can be reviewed to ascertain their applicability and completeness.
1.2.2 For use in the preparation of process specifications dealing with the fluorescent penetrant examination of materials and parts
using the hydrophilic post-emulsification process. Agreement by the purchaser and the manufacturer regarding specific techniques
is strongly recommended.
1.2.3 For use in the organization of the facilities and personnel concerned with the liquid penetrant examination.
1.3 This practice does not indicate or suggest standards for evaluation of the indications obtained. It should be pointed out,
however, that indications must be interpreted or classified and then evaluated. For this purpose there must be a separate code or
specification or a specific agreement to define the type, size, location, and direction of indications considered acceptable, and those
considered unacceptable.
1.3.1 The user is encouraged to use materials and processing parameters necessary to detect conditions of a type or severity which
could affect the evaluation of the product.
1.4 Units—The values stated in inch-pound units are to be regarded as standard. SI unitsThe values given in parentheses are for
information only.mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 All areas of this practice may be open to agreement between the cognizant engineering organization and the supplier, or
specific direction from the cognizant engineering organization.
1
This practice is under the jurisdiction of ASTM Committee E07 on Nondestructive Testing and is the direct responsibility of Subcommittee E07.03 on Liquid Penetrant
and Magnetic Particle Methods.
Current edition approved June 1, 2016July 1, 2021. Published June 2016August 2021. Originally approved in 1987. Last previous edition approved in 20102016 as E1210 -
10. – 16. DOI: 10.1520/E1210-16.10.1520/E1210-21.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E1210 − 21
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use.
1.6 All areas of this practice may be open to agreement between the cognizant engineering organization and the supplier, or
specific direction from the cognizant engineering organization.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
D129 Test Method for Sulfur in Petroleum Products (General High Pressure Decomposition Device Method)
D516 Test Method for Sulfate Ion in Water
D808 Test Method for Chlorine in New and Used Petroleum Products (High Pressure Decomposition Device Method)
D1552 Test Method
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.