Standard Specification for Installation of Steel Framing Members to Receive Screw-Attached Gypsum Panel Products

ABSTRACT
This specification covers the minimum requirements for the installation of interior nonstructural steel framing and furring members designed to receive screw-attached gypsum panel products. Details of construction for a specific assembly to achieve the required fire resistance shall be obtained from reports of fire-resistance tests, engineering evaluations, or listings from recognized fire testing laboratories. Each element of the assembly, that is, the studs, runners, rigid furring channels, tie wires, hanger wires, grid suspension systems (consisting of the main beam, cross furring members, and rod and flat hangers) shall be manufactured in the specified dimensions. Specified installation procedures for the metal framing, which includes the runners, studs, chase wall partitions, rigid furring channels, wall furring-bracket systems, and soffits, are detailed thoroughly. Installation requirements for the suspended and furred ceilings, including the main runners, flat hangers and inserts, wood constructions, furring members, rigid furring channels, and grid suspension systems, are discussed methodically as well.
SCOPE
1.1 This specification covers the minimum requirements for the installation of interior nonstructural steel framing and furring members designed to receive screw-attached gypsum panel products. The steel framing and furring members covered in this specification are limited to those complying with Specification C645.  
1.2 Details of construction for a specific assembly to achieve the required fire resistance, sound or acoustic rating shall be obtained from reports of fire-resistance tests, engineering evaluations, or listings from recognized fire testing, sound or acoustic laboratories.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

General Information

Status
Historical
Publication Date
31-Oct-2009
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C754-09a - Standard Specification for Installation of Steel Framing Members to Receive Screw-Attached Gypsum Panel Products
English language
12 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C754 – 09a
Standard Specification for
Installation of Steel Framing Members to Receive Screw-
1
Attached Gypsum Panel Products
This standard is issued under the fixed designation C754; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope* C645 Specification for Nonstructural Steel Framing Mem-
bers
1.1 This specification covers the minimum requirements for
C840 Specification for Application and Finishing of Gyp-
the installation of interior nonstructural steel framing and
sum Board
furring members designed to receive screw-attached gypsum
3
2.2 ICC-ES Document
panel products. The steel framing and furring members cov-
ICC-ES-AC86 Acceptance Criteria for Steel Studs and
ered in this specification are limited to those complying with
Gypsum-Board Interior Nonload-Bearing Walls—
Specification C645.
Complete Construction—AC86—Approved July 1995
1.2 Details of construction for a specific assembly to
(Editorially revised September 2005) (Formerly ICBO
achieve the required fire resistance, sound or acoustic rating
AC86 dated July 1995)
shallbeobtainedfromreportsoffire-resistancetests,engineer-
ing evaluations, or listings from recognized fire testing, sound
3. Terminology
or acoustic laboratories.
3.1 Definitions—Terms shall be as defined in Terminology
1.3 The values stated in inch-pound units are to be regarded
C11.
as standard. The values given in parentheses are mathematical
3.2 Descriptions of Terms Specific to This Standard:
conversions to SI units that are provided for information only
3.2.1 channel, n—the material described in 4.3 to which
and are not considered standard.
furring members are attached.
2. Referenced Documents 3.2.2 cross furring, n—furring member attached perpen-
2
dicular to main runners or framing members.
2.1 ASTM Standards:
3.2.3 cross furring member, n—a member installed perpen-
A641/A641M Specification for Zinc−Coated (Galvanized)
dicularlytothemainbeamsdesignedtoreceivescrewattached
Carbon Steel Wire
gypsum panel products.
A653/A653M Specification for Steel Sheet, Zinc-Coated
3.2.4 direct furring, n—furring members attached directly
(Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed)
to the structural members of the building.
by the Hot-Dip Process
3.2.5 framing member, n—metal studs, runners (track), and
A1008/A1008M Specification for Steel, Sheet, Cold-
rigid furring channels designed to receive screw attached
Rolled, Carbon, Structural, High-Strength Low-Alloy,
gypsum panel products.
High-Strength Low-Alloy with Improved Formability, So-
3.2.6 furred ceiling, n—a ceiling in which the rigid furring
lution Hardened, and Bake Hardenable
channels and studs are attached directly to the structural
C11 TerminologyRelatingtoGypsumandRelatedBuilding
members of the building.
Materials and Systems
3.2.7 furring, v—preparingawallorceilingwithframingor
furring members to provide a level surface or airspace.
3.2.8 furring member, n—metal studs, rigid furring chan-
1
This specification is under the jurisdiction of ASTM Committee C11 on
nels, or channels used either as direct furring or as cross
GypsumandRelatedBuildingMaterialsandSystemsandisthedirectresponsibility
furring.
ofSubcommitteeC11.03onSpecificationsfortheApplicationofGypsumandOther
3.2.9 grid suspension system, n—a ceiling system com-
Products in Assemblies.
Current edition approved Nov. 1, 2009. Published December 2009. Originally
posed of modular interlocking steel components designed to
approved in 1974. Last previous edition approved in 2009 as C754–09. DOI:
receive screw-attached gypsum panel products.
10.1520/C0754-09a.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on Available from ICC Evaluation Services, Inc., 5360 Workman Mill Road,
the ASTM website. Whittier, CA 90601, www.icc-es.org.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C754 – 09a
3.2.10 main beam, n—the main support member of a grid 5. Installation of Metal Framing
suspension system that receives cross furring members.
5.1 Tolerances:
3.2.11 main runner, n—the channel or stud that is attached
5.1.1 Spacing of studs and furring members shall be not
1
to or suspended from the structural members of the build
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.