ASTM E1795-04
(Specification)Standard Specification for Non-Reinforced Liquid Coating Encapsulation Products for Leaded Paint in Buildings
Standard Specification for Non-Reinforced Liquid Coating Encapsulation Products for Leaded Paint in Buildings
ABSTRACT
This specification covers minimum material performance requirements and laboratory test procedures for nonreinforced liquid coating encapsulation products (single or multiple-coat systems) for leaded paint in buildings. Three types of nonreinforced liquid coating encapsulation products are presented: type I - encapsulation products intended for interior use, type II - encapsulation products intended for exterior use, and type III - encapsulation products intended for either interior or exterior use. The impact resistance, adhesion, dry abrasion resistance, water vapour transmission, water and chemical resistance, surface burning characteristics, and volatile organic compound content shall be tested to meet the requirements prescribed. Weathering, aging, scrub resistance, mildew resistance, paintability/repairability, flexibility, and tensile properties shall be tested to meet the requirements prescribed.
SCOPE
1.1 This specification covers minimum material performance requirements and laboratory test procedures for non-reinforced liquid coating encapsulation products (single or multiple-coat systems) for leaded paint in buildings. Performance properties addressed in this specification are:
1.1.1 Impact resistance,
1.1.2 Adhesion,
1.1.3 Dry Abrasion Resistance,
1.1.4 Water Vapor Transmission,
1.1.5 Water and Chemical Resistance,
1.1.6 Surface Burning Characteristics,
1.1.7 Volatile Organic Compound (VOC) Content,
1.1.8 Weathering,
1.1.9 Aging,
1.1.10 Scrub Resistance,
1.1.11 Mildew Resistance,
1.1.12 Paintability/Repairability,
1.1.13 Flexibility, and
1.1.14 Tensile Properties.
1.2 This specification does not address the selection of an encapsulation product for specific use conditions. Specific use conditions may require performance values other than those stated in this specification. See Guide E 1796.
1.3 This specification complements Specification E 1797 for reinforced liquid coating encapsulation products.
1.4 This specification does not cover the use of encapsulation products on industrial steel structures nor on residential coated metal surfaces because no corrosion control requirements are included.
1.5 This specification applies to any non-reinforced liquid applied product that relies primarily on adhesion for attachment to the surface. These products are used to encapsulate a leaded paint surface with the intent of reducing human exposure to lead.
1.6 The results of the test methods included in this specification will not necessarily predict field performance.
1.7 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: E1795 – 04
Standard Specification for
Non-Reinforced Liquid Coating Encapsulation Products for
1
Leaded Paint in Buildings
This standard is issued under the fixed designation E1795; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 1.6 The results of the test methods included in this specifi-
cation will not necessarily predict field performance.
1.1 This specification covers minimum material perfor-
1.7 The values stated in SI units are to be regarded as the
mance requirements and laboratory test procedures for non-
standard. The values given in parentheses are for information
reinforced liquid coating encapsulation products (single or
only.
multiple-coat systems) for leaded paint in buildings. Perfor-
1.8 This standard does not purport to address all of the
mance properties addressed in this specification are:
safety concerns, if any, associated with its use. It is the
1.1.1 Impact resistance,
responsibility of the user of this standard to establish appro-
1.1.2 Adhesion,
priate safety and health practices and determine the applica-
1.1.3 Dry Abrasion Resistance,
bility of regulatory requirements prior to use.
1.1.4 Water Vapor Transmission,
1.1.5 Water and Chemical Resistance,
2. Referenced Documents
1.1.6 Surface Burning Characteristics,
2
2.1 ASTM Standards:
1.1.7 Volatile Organic Compound (VOC) Content,
D16 Terminology for Paint, Related Coatings, Materials,
1.1.8 Weathering,
and Applications
1.1.9 Aging,
D522 Test Methods for Mandrel Bend Test of Attached
1.1.10 Scrub Resistance,
Organic Coatings
1.1.11 Mildew Resistance,
D823 Practices for Producing Films of Uniform Thickness
1.1.12 Paintability/Repairability,
of Paint, Varnish, and Related Products on Test Panels
1.1.13 Flexibility, and
D1005 Test Method for Measurement of Dry-Film Thick-
1.1.14 Tensile Properties.
ness of Organic Coatings Using Micrometers
1.2 This specification does not address the selection of an
D1186 Test Methods for Nondestructive Measurement of
encapsulation product for specific use conditions. Specific use
Dry Film Thickness of Nonmagnetic Coatings Applied to
conditions may require performance values other than those
3
a Ferrous Base
stated in this specification. See Guide E1796.
D1212 Test Methods for Measurement of Wet Film Thick-
1.3 This specification complements Specification E1797 for
ness of Organic Coatings
reinforced liquid coating encapsulation products.
D1308 Test Method for Effect of Household Chemicals on
1.4 This specification does not cover the use of encapsula-
Clear and Pigmented Organic Finishes
tion products on industrial steel structures nor on residential
D1475 Test Method For Density of Liquid Coatings, Inks,
coated metal surfaces because no corrosion control require-
and Related Products
ments are included.
D1653 Test Methods for Water Vapor Transmission of
1.5 This specification applies to any non-reinforced liquid
Organic Coating Films
applied product that relies primarily on adhesion for attach-
D2370 Test Method forTensile Properties of Organic Coat-
ment to the surface. These products are used to encapsulate a
ings
leaded paint surface with the intent of reducing human expo-
D2486 Test Methods for Scrub Resistance of Wall Paints
sure to lead.
1 2
This specification is under the jurisdiction of ASTM Committee E06 on For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Performance of Buildings and is the direct responsibility of Subcommittee E06.23 contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
on Lead Hazards Associated with Buildings. Standards volume information, refer to the standard’s Document Summary page on
Current edition approved April 1, 2004. Published April 2004. Originally the ASTM website.
3
approved in 1995. Last previous edition approved in 2000 as E1795–00. DOI: Withdrawn. The last approved version of this historical standard is referenced
10.1520/E1795-04. on www.astm.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
E1795 – 04
D2794 Test Method for Resistance of Organic Coatings to 4.2 Type II: Exterior Use Only—Type II defines encapsula-
the Effects of Rapid Deformation (Impact) tion products intended for exterior use. These products shall
D3273 Test Method for Resistance to Growth of Mold on meet the requirements of this specification except that for
the Surface of Interior Coatings in an Environmental interior aging (that is, test method described in 10.10.2 not
Chamber conducted).
D3274 Tes
...
Questions, Comments and Discussion