Standard Test Method for Time of Setting of Grouts for Preplaced-Aggregate Concrete in the Laboratory

SCOPE
1.1 This method covers the determination test of time of setting of hydraulic cement grout mixtures used in preplaced-aggregate (PA) concrete using the vicat apparatus.  
1.2 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-Dec-1991
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM C953-87(1997) - Standard Test Method for Time of Setting of Grouts for Preplaced-Aggregate Concrete in the Laboratory
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C953–87 (Reapproved 1997)
Standard Test Method for
Time of Setting of Grouts for Preplaced-Aggregate Concrete
in the Laboratory
This standard is issued under the fixed designation C 953; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 6. Test Sample
1.1 This method covers the determination test of time of 6.1 The test sample shall consist of at least 300 mLof grout
setting of hydraulic cement grout mixtures used in preplaced- taken from a freshly-mixed batch prepared in accordance with
aggregate (PA) concrete using the vicat apparatus. Practice C 938 obtained from a mixer at the laboratory or
1.2 This standard does not purport to address all of the construction site.
safety concerns, if any, associated with its use. It is the
7. Procedure
responsibility of the user of this standard to establish appro-
7.1 Warm the Vicat conical ring and base plate to approxi-
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use. mately 100°C.
7.2 Apply a thin film of paraffin wax to the base of the
2. Referenced Documents
conical ring and place the waxed conical ring on the base plate.
2.1 ASTM Standards: Place a weight on the conical ring to ensure intimate contact
C 191 Test Method for Time of Setting of Hydraulic Ce- with the base plate and allow the conical ring and plate to cool
ment by Vicat Needle to room temperature.
C 938 Practice for Proportioning Grout Mixtures for 7.3 Fill the conical ring apparatus with grout flush with its
Preplaced-Aggregate Concrete top within 2 min after completion of mixing. Strike off the
C 511 Specification for Moist Cabinets, Moist Rooms, and grout flush with the top of the conical ring by a single oblique
Water Storage Tanks Used in the Testing of Hydraulic stroke of a sharp-edged trowel held at a slight angle to the top
Cements and Concretes of the ring. Smooth the top, if necessary, with a few light
touches of the pointed end of the trowel. Take care not to
3. Summary of Method
compress the sample during these cutting and smoothing
3.1 The time of setting, initial and final, of a sample of fluid
operations. The time of completion of molding shall be taken
grout is determined using the Vicat apparatus. as the start of measurement of time of set.
7.4 Store the specimen in the moist room.
4. Significance and Use
7.5 Determine the time of setting using the procedure
4.1 This test method determines the setting time of grout
described in Test Method C 191 except that the first reading
mixed to the fluid consistency required for its use in PA
shall be taken 3 h 6 15 min after po
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.