ASTM D2095-96(2008)
(Test Method)Standard Test Method for Tensile Strength of Adhesives by Means of Bar and Rod Specimens
Standard Test Method for Tensile Strength of Adhesives by Means of Bar and Rod Specimens
SIGNIFICANCE AND USE
Tension tests provide reasonably accurate information with regard to the tensile strength of adhesives. Tensile strength data may be suitable for specification acceptance, service evaluation, manufacturing control, research, and development. Tension tests are not considered significant for applications differing from the test in rate, direction, and type of loading.
SCOPE
1.1 This test method covers the determination of the relative tensile strength of adhesives by the use of bar- and rod-shaped butt-joined specimens under defined conditions of preparation, conditioning, and testing. This test method is applicable to the testing of adhesives with various adherend materials in either similar or dissimilar combinations.
Note 1—An alternative test method for determining the tensile strength of adhesives is Test Method D 897.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D2095 − 96 (Reapproved 2008)
StandardTest Method for
Tensile Strength of Adhesives by Means of Bar and Rod
Specimens
This standard is issued under the fixed designation D2095; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 3.2 Definitions of Terms Specific to This Standard:
3.2.1 tensile strength of an adhesive, n— the maximum
1.1 This test method covers the determination of the relative
tensile stress which it is capable of sustaining. Tensile strength
tensile strength of adhesives by the use of bar- and rod-shaped
is calculated from the maximum load during a tension test
butt-joined specimens under defined conditions of preparation,
carried to rupture and the original cross-sectional area of the
conditioning, and testing. This test method is applicable to the
specimen (see Terminology E6).
testing of adhesives with various adherend materials in either
similar or dissimilar combinations.
4. Significance and Use
NOTE1—Analternativetestmethodfordeterminingthetensilestrength
4.1 Tension tests provide reasonably accurate information
of adhesives is Test Method D897.
withregardtothetensilestrengthofadhesives.Tensilestrength
1.2 The values stated in SI units are to be regarded as the
data may be suitable for specification acceptance, service
standard. The values given in parentheses are for information
evaluation, manufacturing control, research, and development.
only.
Tension tests are not considered significant for applications
1.3 This standard does not purport to address all of the differing from the test in rate, direction, and type of loading.
safety concerns, if any, associated with its use. It is the
5. Apparatus
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica-
5.1 Testing Machine—A testing machine capable of main-
bility of regulatory limitations prior to use.
taining a specified rate of loading, with the error for indicated
loads that are to be measured not exceeding 61 % and the
2. Referenced Documents
load-indicating mechanism essentially free of inertial lag at a
2.1 ASTM Standards:
specified rate of loading. Verify the accuracy of the testing
D897 Test Method for Tensile Properties ofAdhesive Bonds
machine in accordance with Practices E4. Ensure that the
D907 Terminology of Adhesives
testing machine is provided with the following:
D2094 Practice for Preparation of Bar and Rod Specimens
5.1.1 Fixed Member—A fixed or essentially stationary
for Adhesion Tests
member carrying one attachment fixture.
E4 Practices for Force Verification of Testing Machines
5.1.2 Movable Member—A movable member carrying a
E6 Terminology Relating to Methods of Mechanical Testing
second attachment fixture.
E104 Practice for Maintaining Constant Relative Humidity
5.1.3 Attachment Fixtures—Self-aligning type fixtures for
by Means of Aqueous Solutions
holdingaspecimenbetweenthefixedmemberandthemovable
member. Ensure that the fixtures are attached to the fixed and
3. Terminology
movable members in such a way that they will move into
alignmentassoonasloadisapplied,sothatthelongaxisofthe
3.1 Many of the terms in this standard are defined in
Terminology D907. test specimen will coincide with the direction of the applied
load.Adesignforfixturesthathasprovensatisfactoryisshown
in Fig. 1 and Fig. 2.
This test method is under the jurisdiction of ASTM Committee D14 on
Adhesives and is the direct responsibility of Subcommittee D14.80 on Metal 5.2 Conditioning Room or Desiccators—A conditioning
Bonding Adhesives.
room capable of maintaining a relative humidity of 50 62%
Current edition approved April 1, 2008. Published April 2008. Originally
at 23 6 1°C (73.4 6 1.8°F) or desiccators containing a
approved in 1962. Last previous edition approved in 2002 as D2095 – 96 (2002).
saturated salt solution (Note 2) to give the same relative
DOI: 10.1520/D2095-96R08.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
humidity and temperature.
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on NOTE 2—Asaturated salt solution of calcium nitrate will give approxi-
the ASTM website. mately 51 % relative humidity at 24.5°C (see Practice E104).
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
D2095 − 96 (Reapproved 2008)
FIG. 1 Test Specimens and Attachment Fixtures
6. Test Specimens
6.1 Description and Preparation—Bar- or rod-type speci-
mens. Refer to Practice D2094 for the design of the specimens
and the procedures used in preparing them.
6.2 Number of Specimens—Test a minimum of five speci-
mens for each test condition.
7. Conditioning
7.1 Cond
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.