SIGNIFICANCE AND USE
5.1 Liquid-applied glazing materials, bedding sealants, glazing compounds (that is, glazing sealants) are designed to provide a seal between the IG unit and the window or wall framing. Frequently there is physical contact between these materials and an IG unit edge sealant. Depending on the particular IG unit edge sealant, there can be a detrimental physical or chemical interaction between it and the liquid-applied glazing material. Detrimental effects may include: weakening, softening, hardening, or adhesive failure of the IG edge sealant, or visual obstruction inside the IG unit.
SCOPE
1.1 This test method covers a laboratory procedure for quantitatively measuring the compatibility of liquid-applied glazing materials with an insulating glass unit edge sealant. Compatibility is determined by measuring the changes in the insulating glass edge sealant adhesive and cohesive properties. Hereinafter insulating glass is referred to as IG.
1.2 This test method does not address the issue of the integrity of the hermetic seal or changes to the vision area in an IG unit. Such factors as possible unit fogging or primary sealant reaction in a dual-seal system due to volatile components permeating the IG sealant are not considered in this test method.
1.3 The committee with jurisdiction over this standard is not aware of any comparable standards published by other organizations.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C1294 − 15
Standard Test Method for
Compatibility of Insulating Glass Edge Sealants with Liquid-
1
Applied Glazing Materials
This standard is issued under the fixed designation C1294; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope compatibility, compound, elongation, glazing, seal, sealant,
standard conditions, and substrate.
1.1 This test method covers a laboratory procedure for
quantitatively measuring the compatibility of liquid-applied
4. Summary of Test Method
glazing materials with an insulating glass unit edge sealant.
4.1 This test method includes the measurement of tensile
Compatibility is determined by measuring the changes in the
insulating glass edge sealant adhesive and cohesive properties. force, elongation, and percent cohesive or adhesive failure and
observations of the specimen’s general physical appearance
Hereinafter insulating glass is referred to as IG.
and observation of elongation.
1.2 This test method does not address the issue of the
4.2 Test specimens are exposed to 70°C (158°F) heat for
integrityofthehermeticsealorchangestothevisionareainan
IG unit. Such factors as possible unit fogging or primary fourweekswhilecontactingtheliquid-appliedglazingmaterial
being evaluated.
sealant reaction in a dual-seal system due to volatile compo-
nents permeating the IG sealant are not considered in this test 4.2.1 Control specimens are exposed only to the 70°C
(158°F) heat.
method.
1.3 Thecommitteewithjurisdictionoverthisstandardisnot 4.3 Compatibilityisdeterminedbycomparingthemeasured
and observed properties of the test specimens to the control
aware of any comparable standards published by other orga-
samples.
nizations.
1.4 This standard does not purport to address all of the
5. Significance and Use
safety concerns, if any, associated with its use. It is the
5.1 Liquid-applied glazing materials, bedding sealants,
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica- glazing compounds (that is, glazing sealants) are designed to
bility of regulatory limitations prior to use. provide a seal between the IG unit and the window or wall
framing. Frequently there is physical contact between these
2. Referenced Documents
materials and an IG unit edge sealant. Depending on the
2
particular IG unit edge sealant, there can be a detrimental
2.1 ASTM Standards:
physical or chemical interaction between it and the liquid-
C717Terminology of Building Seals and Sealants
applied glazing material. Detrimental effects may include:
C1265Test Method for Determining the Tensile Properties
weakening, softening, hardening, or adhesive failure of the IG
of an Insulating Glass Edge Seal for Structural Glazing
edge sealant, or visual obstruction inside the IG unit.
Applications
3. Terminology
6. Apparatus and Accessory Materials
3.1 Definitions—Refer to Terminology C717 for definitions
6.1 Oven, forced draft, capable of maintaining a constant
of the following terms: adhesive failure, cohesive failure,
temperature of 70 6 3°C (158 6 5°F).
6.2 Tensile Testing Machine, capable of producing a tensile
1
ThistestmethodisunderthejurisdictionofASTMCommitteeC24onBuilding
load on the specimen at the rate of 5 6 0.51 mm (0.2 6 0.02
Seals and Sealants and is the direct responsibility of Subcommittee C24.20 on
in.) per minute.
General Test Methods.
6.2.1 Fixed Member—A fixed or essentially stationary
Current edition approved Dec. 1, 2015. Published January 2016. Originally
member carrying one grip.
approvedin1995.Lastpreviouseditionapprovedin2011asC1294–07(2011).DOI:
10.1520/C1294-15.
6.2.2 Moveable Member—A moveable member carrying a
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
second grip.
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
6.2.3 Grips—The grips should be suitable to firmly grasp
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. the test fixture that holds the test specimen and should be
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
C1294 − 15
designed to eliminate eccentric specimen loading. Specimen 6.11 Container, a shallow aluminum or glass pan or tray is
loading should be parallel to the centerline of the short axis of suitable.Thecontainermustbelargeenoughtoholdallthetest
the sealant. A swivel or universal joint near each end of the
specimens.Acontainer is required for each combination of IG
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C1294 − 07 (Reapproved 2011) C1294 − 15
Standard Test Method for
Compatibility of Insulating Glass Edge Sealants with Liquid-
1
Applied Glazing Materials
This standard is issued under the fixed designation C1294; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This test method covers a laboratory procedure for quantitatively measuring the compatibility of liquid-applied glazing
materials with an insulating glass unit edge sealant. Compatibility is determined by measuring the changes in the insulating glass
edge sealant adhesive and cohesive properties. Hereinafter insulating glass is referred to as IG.
1.2 This test method does not address the issue of the integrity of the hermetic seal or changes to the vision area in an IG unit.
Such factors as possible unit fogging or primary sealant reaction in a dual-seal system due to volatile components permeating the
IG sealant are not considered in this test method.
1.3 The committee with jurisdiction over this standard is not aware of any comparable standards published by other
organizations.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
C717 Terminology of Building Seals and Sealants
C1265 Test Method for Determining the Tensile Properties of an Insulating Glass Edge Seal for Structural Glazing Applications
3. Terminology
3.1 Definitions—Refer to Terminology C717 for definitions of the following terms: adhesive failure, cohesive failure,
compatibility, compound, elongation, glazing, seal, sealant, standard conditions, and substrate.
4. Summary of Test Method
4.1 This test method includes the measurement of tensile force, elongation, and percent cohesive or adhesive failure and
observations of the specimen’s general physical appearance and observation of elongation.
4.2 Test specimens are exposed to 70°C (158°F) heat for four weeks while contacting the liquid-applied glazing material being
evaluated.
4.2.1 Control specimens are exposed only to the 70°C (158°F) heat.
4.3 Compatibility is determined by comparing the measured and observed properties of the test specimens to the control
samples.
5. Significance and Use
5.1 Liquid-applied glazing materials, bedding sealants, glazing compounds (that is, glazing sealants) are designed to provide a
seal between the IG unit and the window or wall framing. Frequently there is physical contact between these materials and an IG
unit edge sealant. Depending on the particular IG unit edge sealant, there can be a detrimental physical or chemical interaction
1
This test method is under the jurisdiction of ASTM Committee C24 on Building Seals and Sealants and is the direct responsibility of Subcommittee C24.20 on General
Test Methods.
Current edition approved Dec. 1, 2011Dec. 1, 2015. Published December 2011January 2016. Originally approved in 1995. Last previous edition approved in 20072011
ε1
as C1294C1294–07(2011).–07 . DOI: 10.1520/C1294-07R11.10.1520/C1294-15.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
C1294 − 15
between it and the liquid-applied glazing material. Detrimental effects may include: weakening, softening, hardening, or adhesive
failure of the IG edge sealant, or visual obstruction inside the IG unit.
6. Apparatus and Accessory Materials
6.1 Oven, forced draft, capable of maintaining a constant temperature of 70 6 3°C (158 6 5°F).
6.2 Tensile Testing Machine, capable of producing a tensile load on the specimen at the rate of 5 6 0.51 mm (0.2 6 0.02 in.)
per minute.
6.2.1 Fixed Member—A fixed or essentially stationary member carrying one grip.
6.2.2 Moveable Member—A moveable member carrying a second grip.
6.2.3 Grips—The grips should be suitable to firmly gra
...
Questions, Comments and Discussion