ASTM E3040-15
(Test Method)Standard Test Method for Evaluation of Instrumental Color Difference with a Gray Scale
Standard Test Method for Evaluation of Instrumental Color Difference with a Gray Scale
SIGNIFICANCE AND USE
5.1 The gray scale grade GSC is useful to evaluate the color difference of any pair of colors that have been subjected to a destructive test whose severity of result is nominated by color difference of the treated member to the untreated member. This includes, but is not limited to, scrub tests, exterior exposures, crocking tests, blocking tests, certain abrasion tests, and color transfer tests.
5.2 A major advantage of the instrumental method of obtaining gray scale grades is that under the visual method substantial screening and training of the operators in visual color assessment is required. No such burden is placed on the operators in this instrumental method.
5.3 The method is usually not used for staining tests which have their own gray scale for staining.
SCOPE
1.1 Test Method D2616 describes a painted gray scale and the procedure to be used in the visual evaluation of color differences on non-self-luminous materials by comparison to this scale. This test method provides an alternative method of obtaining a similarly valued result by an instrumental method.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard, except that the test results of this test method are converted by the calculations to an arbitrary visual scale defined by Test Method D2616, whose units are called GSC (Gray Scale for Change in Color).
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: E3040 − 15
StandardTest Method for
Evaluation of Instrumental Color Difference with a Gray
1
Scale
This standard is issued under the fixed designation E3040; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
3
1. Scope 2.2 ISO Standards:
ISO 105-A05 Textiles—Tests for Colorfastness—Part A05
1.1 Test Method D2616 describes a painted gray scale and
Instrumental assessment of change in colour for determi-
the procedure to be used in the visual evaluation of color
nation of grey scale rating
differences on non-self-luminous materials by comparison to
4
2.3 AATCC Standards:
this scale. This test method provides an alternative method of
AATCC Evaluation Procedure 7 InstrumentalAssessment of
obtaining a similarly valued result by an instrumental method.
the Change in Color of a Test Specimen
5
1.2 The values stated in SI units are to be regarded as
2.4 JIS Standards:
standard. No other units of measurement are included in this
JIS L 0809 Instrumental determination of colour fastness —
standard, except that the test results of this test method are
Change in colour and staining
converted by the calculations to an arbitrary visual scale
3. Terminology
defined by Test Method D2616, whose units are called GS
C
(Gray Scale for Change in Color).
3.1 Definitions:
1.3 This standard does not purport to address all of the 3.1.1 Definitions of appearance terms in Terminology E284
safety concerns, if any, associated with its use. It is the
are applicable to this test method.
responsibility of the user of this standard to establish appro- 3.2 Definitions of Terms Specific to This Standard:
priate safety and health practices and determine the applica-
3.2.1 color change, n—a change in color of any kind
bility of regulatory limitations prior to use. whether in lightness, hue, or chroma or any combination of
these, discernible by comparing the test specimen with a
2. Referenced Documents
corresponding untested specimen.
2
2.1 ASTM Standards:
3.2.2 gray scale grade, GS , n—for color change, the
C
D2244 Practice for Calculation of Color Tolerances and
numerical value that is assigned to the change in color of a test
Color Differences from Instrumentally Measured Color
specimen as compared to an original or untreated specimen.
Coordinates
D2616 Test Method for Evaluation of Visual Color Differ-
4. Summary of Test Method
ence With a Gray Scale
4.1 The color of a specimen that has been submitted to a
E284 Terminology of Appearance
destructive test whose severity is evaluated by change in color,
E308 PracticeforComputingtheColorsofObjectsbyUsing
and an identical untreated specimen, are measured spectropho-
the CIE System
tometrically and both of their colors evaluated by conventional
E1164 PracticeforObtainingSpectrometricDataforObject-
means. The conventional color difference attributes are con-
Color Evaluation
verted to a Gray Scale for Color Change by a series of
calculations.
1
This test method is under the jurisdiction of ASTM Committee E12 on Color
and Appearance and is the direct responsibility of Subcommittee E12.04 on Color
3
and Appearance Analysis. Available from American National Standards Institute (ANSI), 25 W. 43rd St.,
Current edition approved Nov. 1, 2015. Published December 2015. DOI: 4th Floor, New York, NY 10036, http://www.ansi.org.
4
10.1520/E3040-15. Available from American Association of Textile Chemists and Colorists
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or (AATCC), P.O. Box 12215, Research Triangle Park, NC 27709-2215, http://
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM www.aatcc.org.
5
Standards volume information, refer to the standard’s Document Summary page on Available from Japanese StandardsAssociation (JSA), Mita MTBldg., 3-13-12
the ASTM website. Mita, Minato-ku, Tokyo 108-0073, Japan, http://www.jsa.or.jp.
Copyright ©ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA19428-2959. United States
1
---------------------- Page: 1 ----------------------
E3040 − 15
4.2 This test method is similar to the following three 9.2 Measure the color of the test specimen which has been
international test methods: AATCC Evaluation Procedure 7, subjected to the colorfastness test and make the same colori-
ISO 105-A05, and JIS L 0809. metric calculations as done for the reference specimen. Then
make the calculations as described in Annex A1.
5. Significance and Use
10. Calculation or Interpretation of Results
5.1 The gray scale grade GS is useful to evaluate the color
C
difference of any pair of colors that have be
...