Standard Specification for Concrete Made By Volumetric Batching and Continuous Mixing

SCOPE
1.1 This specification covers concrete made from materials continuously batched by volume, mixed in a continuous mixer, and delivered to the purchaser in a freshly mixed and unhardened state. Tests and criteria for batching accuracy and mixing efficiency are specified herein.
1.2 The values stated in either SI units, shown in brackets, or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.
1.3 This specification references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this specification.

General Information

Status
Historical
Publication Date
09-Aug-2001
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C685/C685M-01 - Standard Specification for Concrete Made By Volumetric Batching and Continuous Mixing
English language
9 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 685/C 685M – 01
Standard Specification for
Concrete Made by Volumetric Batching and Continuous
1
Mixing
This standard is issued under the fixed designation C 685/C 685M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
3
1. Scope C 150 Specification for Portland Cement
C 173 Test Method for Air Content of Freshly Mixed
1.1 This specification covers concrete made from materials
2
Concrete by the Volumetric Method
continuously batched by volume, mixed in a continuous mixer,
C 191 Test Method for Time of Setting of Hydraulic Ce-
and delivered to the purchaser in a freshly mixed and unhard-
3
ment by Vicat Needle
ened state. Tests and criteria for batching accuracy and mixing
C 231 Test Method for Air Content of Freshly Mixed
efficiency are specified herein.
2
Concrete by the Pressure Method
1.2 The values stated in either SI units, shown in brackets,
C 260 Specification forAir-EntrainingAdmixtures for Con-
or inch-pound units are to be regarded separately as standard.
2
crete
The values stated in each system may not be exact equivalents;
C 330 Specification for Lightweight Aggregates for Struc-
therefore,eachsystemshallbeusedindependentlyoftheother.
2
tural Concrete
Combining values from the two systems may result in noncon-
C 494/C 494M Specification for Chemical Admixtures for
formance with the standard.
2
Concrete
1.3 This specification references notes and footnotes which
C 567 Test Method for Unit Weight of Structural Light-
provide explanatory material. These notes and footnotes (ex-
2
weight Concrete
cluding those in tables and figures) shall not be considered as
3
C 595 Specification for Blended Hydraulic Cements
requirements of this specification.
C 618 Specification for Coal Fly Ash and Raw or Calcined
2. Referenced Documents Natural Pozzolan for Use as a Mineral Admixture in
2
Portland Cement Concrete
2.1 ASTM Standards:
C 989 Specification for Ground Granulated Blast-Furnace
C 31/C 31M Practice for Making and Curing Concrete Test
2
2
Slag for Use in Concrete and Mortars
Specimens in the Field
2
C 1017/C 1017M Specification for Chemical Admixtures
C 33 Specification for Concrete Aggregates
2
for Use in Producing Flowing Concrete
C 39/C 39M Test Method for Compressive Strength of Cy-
2
C 1064/C 1064M Test Method for Temperature of Freshly
lindrical Concrete Specimens
2
Mixed Portland Cement Concrete
C 109/C 109M Test Method for Compressive Strength of
C 1077 PracticeforLaboratoriesTestingConcreteandCon-
Hydraulic Cement Mortars (Using 2-in. or 50-mm Cube
3
crete Aggregates for Use in Construction and Criteria for
Specimens)
2
Laboratory Evaluation
C 127 Test Method for Specific Gravity and Absorption of
3
2
C 1157 Performance Specification for Hydraulic Cement
Coarse Aggregate
4
D 512 Test Methods for Chloride Ion in Water
C 136 Test Method for Sieve Analysis of Fine and Coarse
4
2
D 516 Test Method for Sulfate Ion in Water
Aggregates
5
2.2 ACI Documents:
C 138 Test Method for Unit Weight, Yield, andAir Content
2
CP-1 Technician Workbook for ACI Certification of Con-
(Gravimetric) of Concrete
crete Field Testing Technician-Grade I
C 143/C 143M Test Method for Slump of Hydraulic-
2
211.1 Standard Practice for Selecting Proportions for Nor-
Cement Concrete
mal, Heavyweight, and Mass Concrete
211.2 Standard Practice for Selecting Proportions for Struc-
1
This specification is under the jurisdiction of ASTM Committee C09 on
tural Lightweight Concrete
Concrete and ConcreteAggregates and is the direct responsibility of Subcommittee
C09.40 on Ready-Mixed Concrete.
Current edition approved Aug. 10, 2001. Published October 2001. Originally
4
published as C 685 – 71 T. Last previous edition C 685 – 00a. Annual Book of ASTM Standards, Vol 11.01.
2 5
Annual Book of ASTM Standards, Vol 04.02. Available from the American Concrete Institute, 38800 Country Club Drive,
3
Annual Book of ASTM Standards, Vol 04.01. Farmington Hills, MI 48331.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C 685/C 685M
NOTE 2—These different cements will produce concretes of different
214 Recommended Practice for Evaluation of Strength Test
properties and should not be used interchangeably.
Results of Concrete
301 Standard Specifications for Structural Concrete 5.1.2 Aggregates—Aggregates shall conform to Specifica-
305R Hot Weather Concreting tion C 33 or Specification C 330 if lightweight concrete is
306R Cold Weather Concreti
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.