Standard Specification for Structural Standing Seam Aluminum Roof Panel Systems

ABSTRACT
This specification covers the design, construction, and weatherability of structural standing seam aluminum roof panel systems. It includes performance requirements for the following elements only: panels, concealed panel clips, panel/clip anchorage, and panel joint sealers. Structural panels shall be designed in accordance with the required specifications for aluminum structures and in accordance with sound engineering methods and practices. The static load capacity and uplift index shall be tested to meet the requirements prescribed. Connections of panels to structural members shall be made with concealed panel clips compatible with the panel design. A fixing line is required to anchor roof panels in order to maintain end alignment and to resist in-plane gravity and thermal force components. Panel-to-panel sidelap connections and endlaps shall be weathertight. Panels of maximum practicable lengths shall be used to minimize endlaps.
SCOPE
1.1 This specification covers the design, construction, and weatherability of structural standing seam aluminum roof panel systems. It includes performance requirements for the following elements only: panels, concealed panel clips, panel/clip anchorage, and panel joint sealers.  
Note 1—These systems are used on both low-slope and steep-slope roof applications. They also are used with or without an underlying deck or sheathing.  
1.2 The objective of this specification is to provide for the overall performance of the structural standing seam aluminum roof panel system as defined in 3.2.6 during its service life in order to provide weather protection, carry the specified design loads, and allow proper access over the roof surface in order to provide for periodic maintenance of the equipment by the building owner.  
1.3 In addition to structural characteristics, the specifier shall evaluate other characteristics beyond the scope of this specification that affect the final choice of roof construction. These include, but are not limited to, functional, legal, insurance, and economic considerations. See Appendix X1 for the specifier's checklist.  
1.4 This specification is not intended to exclude products or systems not covered by the referenced documents.  
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.6 The text of this specification contains notes and footnotes that provide explanatory information and are not requirements of this specification.

General Information

Status
Historical
Publication Date
14-Aug-2011
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM E1637-98(2011) - Standard Specification for Structural Standing Seam Aluminum Roof Panel Systems
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:E1637 −98(Reapproved 2011)
Standard Specification for
1
Structural Standing Seam Aluminum Roof Panel Systems
This standard is issued under the fixed designation E1637; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
2
1.1 This specification covers the design, construction, and 2.1 ASTM Standards:
B209Specification for Aluminum and Aluminum-Alloy
weatherabilityofstructuralstandingseamaluminumroofpanel
systems. It includes performance requirements for the follow- Sheet and Plate
C711Test Method for Low-Temperature Flexibility and
ing elements only: panels, concealed panel clips, panel/clip
anchorage, and panel joint sealers. Tenacity of One-Part, Elastomeric, Solvent-Release Type
Sealants
NOTE 1—These systems are used on both low-slope and steep-slope
C765Test Method for Low-Temperature Flexibility of Pre-
roof applications. They also are used with or without an underlying deck
formed Tape Sealants
or sheathing.
C879TestMethodsforReleasePapersUsedwithPreformed
1.2 The objective of this specification is to provide for the
Tape Sealants
overall performance of the structural standing seam aluminum
D1667Specification for Flexible Cellular Materials—Poly
roof panel system as defined in 3.2.6 during its service life in
(Vinyl Chloride) Foam (Closed-Cell)
order to provide weather protection, carry the specified design
D3310Test Method for Determining Corrosivity of Adhe-
loads,andallowproperaccessovertheroofsurfaceinorderto
sive Materials
provide for periodic maintenance of the equipment by the
E631Terminology of Building Constructions
building owner.
E1592Test Method for Structural Performance of Sheet
1.3 In addition to structural characteristics, the specifier
Metal Roof and Siding Systems by Uniform Static Air
shall evaluate other characteristics beyond the scope of this
Pressure Difference
specification that affect the final choice of roof construction.
E1646Test Method for Water Penetration of Exterior Metal
These include, but are not limited to, functional, legal,
Roof Panel Systems by Uniform Static Air Pressure
insurance, and economic considerations. See Appendix X1 for
Difference
the specifier’s checklist.
E1680Test Method for Rate of Air Leakage Through Exte-
rior Metal Roof Panel Systems
1.4 This specification is not intended to exclude products or
G21Practice for Determining Resistance of Synthetic Poly-
systems not covered by the referenced documents.
meric Materials to Fungi
1.5 Thevaluesstatedininch-poundunitsaretoberegarded
3
2.2 FM Approvals LLC Standard:
as standard. The values given in parentheses are mathematical
Approval Standardfor Class 1 Panel Roofs, Class Number
conversions to SI units that are provided for information only
4471
and are not considered standard.
4
2.3 UL Standard:
1.6 The text of this specification contains notes and foot-
UL580Standard for Safety, Tests for Uplift Resistance of
notesthatprovideexplanatoryinformationandarenotrequire-
Roof Assemblies
ments of this specification.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
1
This specification is under the jurisdiction of ASTM Committee E06 on Standards volume information, refer to the standard’s Document Summary page on
Performance of Buildings and is the direct responsibility of Subcommittee E06.57 the ASTM website.
3
on Performance of Metal Roof Systems. Available from FM Approvals LLC, 1151 Boston Providence Turnpike, P.O.
Current edition approved Aug. 15, 2011. Published September 2011. Originally Box 9102, Norwood, MA 02062, http://www.fmglobal.com.
4
approved in 1994. Last previous edition approved in 2003 as E1637–98(2003). Available from Underwriters Laboratories (UL), 2600 N.W. Lake Rd., Camas,
DOI: 10.1520/E1637-98R11. WA 98607-8542, http://www.ul.com.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E1637−98(2011)
5
2.4 AA Document: 4.1.3 Thermal movement shall be provided for in accor-
Aluminum Design Manual, Latest Edition dance with Sections 7 and 8. Temperature extremes for many
6
localities are found in documents referenced in 2.6-2.8.
2.5 AISI Document:
4.1.4 The standing seam roof system clips do not always
S100NorthAmerican Specification for the Design of Cold-
provide full lateral support to secondary structural members.
Formed Steel Structure Members
The degree of lateral support provided to the secondary
7
2.6 MBMA Document:
structuralmembers
...

Questions, Comments and Discussion