Standard Guide for Measuring Soil Removal from Artificially Soiled Fabrics (Not Suitable for Detergent Ranking)

SCOPE
1.1 This is a guide for measuring the ability of detergents to remove artificially applied soils from fabrics. It is intended as a laboratory screening test to aid in the formulation of detergent products, for quality control and as a basis between the purchaser and seller in standardizing specific products' performance.
1.2 The relative ranking of detergent products will vary greatly depending on the type of soiled fabrics used in the test. Therefore, selection of the standard soiled fabric to be used in a test shall be made by agreement between the interested parties on the basis of experience.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
14-May-2005
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Guide
ASTM D3050-05 - Standard Guide for Measuring Soil Removal from Artificially Soiled Fabrics (Not Suitable for Detergent Ranking)
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D 3050 – 05
Standard Guide for
Measuring Soil Removal from Artificially Soiled Fabrics (Not
1
Suitable for Detergent Ranking)
This standard is issued under the fixed designation D 3050; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope correlation of the detergency performance of any particular
soiled cloth or clothes with detergency of naturally soiled
1.1 This is a guide for measuring the ability of detergents to
articles.
remove artificially applied soils from fabrics. It is intended as
4.2 A suggested procedure for comparing the performance
a laboratory screening test to aid in the formulation of
of any two laundry detergents on naturally soiled family items
detergent products, for quality control and as a basis between
in home laundry equipment under controlled conditions on a
the purchaser and seller in standardizing specific products’
paired comparison basis is described in Method D 2960.
performance.
1.2 The relative ranking of detergent products will vary
5. Apparatus
greatly depending on the type of soiled fabrics used in the test.
5.1 Laboratory Washer—A laboratory scale agitator-type
Therefore, selection of the standard soiled fabric to be used in
3
washing machine.
a test shall be made by agreement between the interested
5.2 Reflectometer, calibrated by means of standard vitreous
parties on the basis of experience.
enamel plaques having reflectances in the range of the fabric or
1.3 This standard does not purport to address all of the
swatch samples being measured.
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro-
6. Reagents and Materials
priate safety and health practices and determine the applica-
6.1 Purity of Reagents—Reagent grade chemicals shall be
bility of regulatory limitations prior to use.
used in all tests. Unless otherwise indicated, it is intended that
2. Referenced Documents all reagents shall conform to the specifications of the Commit-
2 tee onAnalytical Reagents of theAmerican Chemical Society,
2.1 ASTM Standards:
4
where such specifications are available. Other grades may be
D 1193 Specification for Reagent Water
used, provided it is first ascertained that the reagent is of
D 2960 Test Method of Controlled Laundering Test Using
sufficiently high purity to permit its use without lessening the
Naturally Soiled Fabrics and Household Appliances
accuracy of the determination.
3. Summary of Guide 6.2 Purity of Water—Unless otherwise indicated, references
to water shall be understood to mean Type IV reagent water
3.1 Soiled fabric swatches are washed in a laboratory
conforming to Specification D 1193.
washer using the products being tested and the change in
6.3 Hard Water Stock Solution—Prepare a hard water stock
reflectance is measured.
solution by dissolving 2.940 6 0.002 g of calcium chloride
4. Significance and Use
dihydrate (CaCl ·2H O) and 2.033 6 0.002 g of magnesium
2 2
chloride hexahydrate (MgCl ·6H O) in about 300 mLof water.
2 2
4.1 Theguide,asnowconstituted,isnotsuitableforranking
Dilute to a volume of 1 L with additional water. This solution
of detergent products since no basis is available at this time for
1
This guide is under the jurisdiction of ASTM Committee D12 on Soaps and
3
Other Detergents and is the responsibility of Subcommittee D12.15 on Physical The Terg-o-tometer, obtainable from the United States Testing Co., 1415 Park
Testing. Ave., Hoboken, NJ, or its equivalent, has been found satisfactory for this purpose.
4
Current edition approved May 15, 2005. Published June 2005. Originally Reagent Chemicals, American Chemical Society Specifications, American
approved in 1972. Last previous edition approved in 1998 as D 3050 – 98. Chemical Society, Washington, DC. For suggestions on the testing of reagents not
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or listed by the American Chemical Society, see Analar Standards for Laboratory
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Chemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeia
Standards volume information, refer to the standard’s Document Summary page on and National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,
the ASTM website. MD.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
D3050–05
suggested since approximately 80 % of the families in the United States
contains 3000 ppm hardness (expressed
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.