SIGNIFICANCE AND USE
5.1 A critical step in preparing a medical device for safe use on the next patient is effective cleaning. Typically cleaning a medical device includes precleaning at the point-of-use, manual and automated methods for removing soil that accumulate during clinical use. The cleaning solution(s) used are almost always water for rinsing and water with a detergent during washing. AAMI TIR34 (also EN 285) provides guidance about the quality of water to be used during reprocessing. This guidance references various test methods to ensure that water meets the recommended quality.
5.2 When it comes to detergents very little guidance can be found in AAMI, ISO, ASTM, and FDA documents. Further, there are very few consensus methods for evaluating the detergents intended to clean medical devices. The result is that very little detail about detergents, for comparison purposes, is known. As a result, device manufacturers, when authoring their instructions for use (IFU) describe in very generic terms the kind of detergent that can be used to clean their device. Similarly, regulators, also have very little to rely upon for clearing reprocessing instructions. Finally, the healthcare facility, that is ultimately responsible for getting the device clean, has very little detail to assure that one brand of detergent is roughly equivalent to the one used by the medical device manufacturer during validation testing.
5.3 While consensus standard test methods do not exist for detergents intended to clean medical devices, there are dozens of such test methods when it comes to detergents intended to clean dishes, laundry, floors, countertops, and so forth. Many of these methods are under the domain of ASTM D12: Soaps and other Cleaning Agents Including Detergents. While differences certainly do exist, essentially the detergents used for the other purposes are roughly formulated in the same way. Using existing test methods can drive detergent formulation development or determine the need fo...
SCOPE
1.1 Detergents play a critical role in the cleaning of clinically-used medical devices, but there are few consensus methods for describing the key characteristics of these detergents. This guide identifies consensus standards, ASTM and others, used to characterize detergents in other applications, which can also be used to characterize detergents used to clean clinically-used medical devices.
1.2 In identifying these test methods, manufacturers of detergents can reference this guide to characterize their detergents.
1.3 By identifying applicable test methods, gaps may be identified where development of new standardized test methods need to be developed to characterize detergents intended to clean medical devices.
1.4 By identifying applicable test methods that are used and results reported by detergent manufacturers, test results can be shared and may lead in the future to development of performance criteria for the key characteristics of detergent.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 Exclusions:
1.6.1 This guide is not intended for detergents formulated to remove residues as a result of the manufacturing process.
1.6.2 This guide does not provide information related to disinfection or disinfecting agents that might be part of a detergent formulation.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the Worl...
- Guide5 pagesEnglish language
ABSTRACT
This guide details the standard procedures for the preparation of aqueous solutions of soaps and detergents and the determination of their pH. The required reagent for this procedure is distilled water or its equivalent, and the recommended electrodes for the determination of pH are the Fischer Accuphast combination electrode or Orion Ross Sure Flow electrode or their equivalents.
SCOPE
1.1 This guide covers the preparation of aqueous solutions of soaps and detergents and the determination of their pH.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Material Safety Data Sheets are available for reagents and materials. Review them for hazards prior to usage.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide2 pagesEnglish language
SIGNIFICANCE AND USE
4.1 The guide, as now constituted, is not suitable for ranking of detergent products since no basis is available at this time for correlation of the detergency performance of any particular soiled cloth or clothes with detergency of naturally soiled articles.
4.2 A suggested procedure for comparing the performance of any two laundry detergents on naturally soiled family items in home laundry equipment under controlled conditions on a paired comparison basis is described in Method D2960.
SCOPE
1.1 This is a guide for measuring the ability of detergents to remove artificially applied soils from fabrics. It is intended as a laboratory screening test to aid in the formulation of detergent products, for quality control and as a basis between the purchaser and seller in standardizing specific products' performance.
1.2 The relative ranking of detergent products will vary greatly depending on the type of soiled fabrics used in the test. Therefore, selection of the standard soiled fabric to be used in a test shall be made by agreement between the interested parties on the basis of experience.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide2 pagesEnglish language
ABSTRACT
This test method covers the determination of the efficiency of ordinary commercial wetting agents using the skein test. It is applicable under limited and controlled conditions, but does not necessarily yield information correlating with specific end uses. The apparatus is comprised of a hook of standard weight depending on the concentration of the wetting agents and an anchor which shall be a flat, cylindrical, lead slug of specific dimensions. The reagents shall consist of water, acid and base test solutions, and wetting agent. The average of at least four determinations of the sinking time for each concentration of wetting agent shall be obtained and presented in plots with logarithmic coordinates. Standard deviation based on six replicate determinations shall also be calculated for precision.
SCOPE
1.1 This test method2,3 covers the determination of the efficiency of ordinary commercial wetting agents as defined in Terminology D459. This test method is applicable under limited and controlled conditions, but does not necessarily yield information correlating with specific end uses.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The methods in this guide can be used for screening of fabric softener products or to evaluate their performance, through a single cycle or multiple accumulative cycles, relative to a designated reference product or a comparative product(s).
5.2 A single assessment of each of the product characteristics tested by these methods will not predict overall performance of the softener product. A single test run under specified fixed conditions cannot be expected to reflect the comparative performance under many other possible conditions of use.
SCOPE
1.1 This guide evaluates the performance characteristics of fabric softener products. It provides guidance for evaluating the on fabric efficacy of treatment chemicals dosed into the wash, rinse, or dryer cycle in a home laundry washer or dryer. This guide can be used for screening of fabric softener products, or to evaluate the products through multiple accumulative cycles.
1.2 The relative ranking of products assessed by these procedures may be affected by such factors as machine type and settings, fabric load composition, as well as by the washing and drying procedures used.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide7 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The guide can be used to compare anti-redeposition performance of products; however, there is no confirmed basis for correlation of this controlled laboratory technique with consumers’ ranking of anti-redeposition performance.
SCOPE
1.1 This guide provides direction for measuring the ability of detergents to prevent the deposition of soils from detergent solutions onto fabrics. It is intended as a laboratory screening test to aid in the formulation of detergent products, for quality control, and as a basis between the purchaser and seller in standardizing specific products' performance.
1.2 The anti-soil deposition performance of detergent products will vary greatly depending on the type of soils and fabrics used in the test. Therefore, selection of the soils, fabrics, reference detergents, and test conditions shall be made by agreement between the interested parties on the basis of experience.
1.3 There is no single or combination of oily soils or particulate soils, or both, that will precisely predict overall the performance of a product or treatment with respect to anti-redeposition as perceived by a consumer. This guide is intended to assess or compare detergent performance with respect to the anti-redeposition performance for the specific soil chosen.
1.4 The values stated in either inch-pound or SI units are to be regarded separately as the standard. The values given in parentheses are for information only.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Material safety data sheets are available for reagents and materials. Review them for hazards prior to usage.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide4 pagesEnglish language
SIGNIFICANCE AND USE
3.1 The cloud point temperature is a reproducible characteristic of certain pure nonionic surfactants. It is also characteristic of certain nonionic surfactant formulated systems. This test method is appropriate for both systems.
Note 1: If the transition from a distinctly cloudy to a clear solution is not sharp, that is, if it does not take place within a range of 1 °C, this test method is not appropriate.
SCOPE
1.1 This test method covers a procedure to determine the “cloud point” of nonionic surfactants or detergent systems. Cloud Point is the temperature at which dissolved components (solids or liquids) are no longer completely soluble, precipating as a second phase giving the fluid a cloudy appearance. It is limited to those surfactants and detergent systems for which the visible solubility change occurs over a range of 1 °C or less at concentrations of 0.5 % to 1.0 % in DI water between 30 °C and 95 °C.
1.2 Chemical Limitations—Nonionic surfactants that exhibit a characteristic cloud point in general terms consist of a water-in-soluble moiety condensed with 50 % to 75 % by weight of ethylene oxide. If the level of ethoxylation is too low the surfactant may not be water soluble at temperatures less than 30 °C, and if it is too high no cloud point may exist.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard2 pagesEnglish language
ABSTRACT
This test method covers the determination of foaming properties of surface-active agents. Glass tubing apparatus for this test method shall include pipet and a receiver. Apparatus requirements like dimensions, shape, calibration marks, rubber stoppers, etc., shall conform to the specifications as indicated in this standard method. Test solution preparation shall include water preheating, adding the surface-active agent while stirring, and solution aging. Test procedure for foaming properties determination shall be done while surface-active solution is aging as indicated in this standard test method. Report shall include test solution concentration, temperature, water hardness, and foam height.
SCOPE
1.1 This test method covers the determination of the foaming properties of surface-active agents as defined in Terminology D459. This test method is applicable under limited and controlled conditions, but does not necessarily yield information correlating with specific end uses. This method is subjected to the operator of the method as the foam heights are not always level and an average height is determined by the user so it is more of a qualitative measurement in these instances. However, for foam measurements results taken on more flat uniform samples this method has more of a quantitative quality.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard3 pagesEnglish language
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This guide suggests a number of staining agents that are representative of stains commonly encountered in household laundry. The assessment need not be limited to this suggested list of stains, especially if special product types or end uses are being evaluated. This guide can be used to compare stain removal performance of products; however, there is no confirmed basis for correlation of this controlled laboratory technique with consumers’ ranking of stain removal performance.
5.2 The evaluations generated by this guide should be regarded as diagnostic screening tests that are useful in formulation studies, quality control, and ingredient raw material qualification. This guide provides considerable flexibility in choosing specific stains, washing conditions, and laboratory equipment appropriate to the objective of the evaluation. This procedural latitude may result in a reduced level of interlaboratory precision and such comparison of results must be evaluated with caution.
5.3 The procedure is applicable to all types of home laundry products including detergents, presoak and prespotter products, bleaches, and detergent boosters and is expected to be applicable to horizontal and vertical axis machines.
5.4 It is not intended for the evaluation of products or conditions normally associated with commercial laundering or dry cleaning establishments.
SCOPE
1.1 This is a guide for evaluating stain removal performance of home laundry products or home laundering conditions. It provides guidance for the selection, preparation, application, and examination of various types of stains on test fabrics that are subjected to controlled but practical stain removal treatment conditions.
1.2 There is no single combination of stain and fabric that will predict the overall performance of a product or treatment method. A single test, even with a variety of stains/fabrics, can only predict how products or treatment methods compare under the particular conditions chosen for evaluations. A series of assessments is necessary to evaluate the many aspects of stain removal performance and to simulate consumer experience more closely.
1.3 In this guide, the use of both traditional top-loader washing machines as well as front and top-loading high-efficiency washers is addressed.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide8 pagesEnglish language
- Guide8 pagesEnglish language
ABSTRACT
This guide covers the evaluation of the effect of dyestuff color transfer or color loss from dyed fabrics. It is designed as a laboratory screening test to aid in the formulation of detergent products or the comparison of two or more detergents, it is not suitable for detergent or washing machine rankings. The apparatus and materials use in evaluating color transfer or color loss of dyed fabrics are presented in details. The procedure for color transfer in one wash, and color loss in three washes are presented in details.
SCOPE
1.1 This guide covers the evaluation of the effect of dyestuff color transfer or color loss from dyed fabrics. It is designed as a laboratory screening test to aid in the formulation of detergent products or the comparison of two or more detergents.
1.2 There is no single assessment that will give the overall performance of a laundry product. A single test can only suggest how a formulation performs under the particular conditions chosen for the evaluation and cannot be expected to reflect comparative product performance under the many other possible conditions of use. A series of assessments is always necessary in order to evaluate the many aspects of product performance. It is necessary to conduct confirming tests under controlled but practical home-laundering conditions to simulate consumer experience.
1.3 The values stated in either inch-pound or SI units are to be regarded separately as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide3 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The guide can be used to compare anti-redeposition performance of products; however, there is no confirmed basis for correlation of this controlled laboratory technique with consumers’ ranking of anti-redeposition performance.
SCOPE
1.1 This guide provides direction for measuring the ability of detergents to prevent the deposition of soils from detergent solutions onto fabrics. It is intended as a laboratory screening test to aid in the formulation of detergent products, for quality control, and as a basis between the purchaser and seller in standardizing specific products' performance.
1.2 The anti-soil deposition performance of detergent products will vary greatly depending on the type of soils and fabrics used in the test. Therefore, selection of the soils, fabrics, reference detergents, and test conditions shall be made by agreement between the interested parties on the basis of experience.
1.3 There is no single or combination of oily soils or particulate soils, or both, that will precisely predict overall the performance of a product or treatment with respect to anti-redeposition as perceived by a consumer. This guide is intended to assess or compare detergent performance with respect to the anti-redeposition performance for the specific soil chosen.
1.4 The values stated in either inch-pound or SI units are to be regarded separately as the standard. The values given in parentheses are for information only.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Material safety data sheets are available for reagents and materials. Review them for hazards prior to usage.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide4 pagesEnglish language
- Guide4 pagesEnglish language
- Guide4 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The methods in this guide can be used for screening of fabric softener products or to evaluate their performance, through a single cycle or multiple accumulative cycles, relative to a designated reference product or a comparative product(s).
5.2 A single assessment of each of the product characteristics tested by these methods will not predict overall performance of the softener product. A single test run under specified fixed conditions cannot be expected to reflect the comparative performance under many other possible conditions of use.
SCOPE
1.1 This guide evaluates the performance characteristics of fabric softener products. It provides guidance for evaluating the on fabric efficacy of treatment chemicals dosed into the wash, rinse, or dryer cycle in a home laundry washer or dryer. This guide can be used for screening of fabric softener products, or to evaluate the products through multiple accumulative cycles.
1.2 The relative ranking of products assessed by these procedures may be affected by such factors as machine type and settings, fabric load composition, as well as by the washing and drying procedures used.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide7 pagesEnglish language
- Guide7 pagesEnglish language
- Guide7 pagesEnglish language
SIGNIFICANCE AND USE
5.1 A critical step in preparing a medical device for safe use on the next patient is effective cleaning. Typically cleaning a medical device includes precleaning at the point-of-use, manual and automated methods for removing soil that accumulate during clinical use. The cleaning solution(s) used are almost always water for rinsing and water with a detergent during washing. AAMI TIR34 (also EN 285) provides guidance about the quality of water to be used during reprocessing. This guidance references various test methods to ensure that water meets the recommended quality.
5.2 When it comes to detergents very little guidance can be found in AAMI, ISO, ASTM, and FDA documents. Further, there are very few consensus methods for evaluating the detergents intended to clean medical devices. The result is that very little detail about detergents, for comparison purposes, is known. As a result, device manufacturers, when authoring their instructions for use (IFU) describe in very generic terms the kind of detergent that can be used to clean their device. Similarly, regulators, also have very little to rely upon for clearing reprocessing instructions. Finally, the healthcare facility, that is ultimately responsible for getting the device clean, has very little detail to assure that one brand of detergent is roughly equivalent to the one used by the medical device manufacturer during validation testing.
5.3 While consensus standard test methods do not exist for detergents intended to clean medical devices, there are dozens of such test methods when it comes to detergents intended to clean dishes, laundry, floors, countertops, and so forth. Many of these methods are under the domain of ASTM D12: Soaps and other Cleaning Agents Including Detergents. While differences certainly do exist, essentially the detergents used for the other purposes are roughly formulated in the same way. Using existing test methods can drive detergent formulation development or determine the need fo...
SCOPE
1.1 Detergents play a critical role in the cleaning of clinically-used medical devices, but there are few consensus methods for describing the key characteristics of these detergents. This guide identifies consensus standards, ASTM and others, used to characterize detergents in other applications, which can also be used to characterize detergents used to clean clinically-used medical devices.
1.2 In identifying these test methods, manufacturers of detergents can reference this guide to characterize their detergents.
1.3 By identifying applicable test methods, gaps may be identified where development of new standardized test methods need to be developed to characterize detergents intended to clean medical devices.
1.4 By identifying applicable test methods that are used and results reported by detergent manufacturers, test results can be shared and may lead in the future to development of performance criteria for the key characteristics of detergent.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 Exclusions:
1.6.1 This guide is not intended for detergents formulated to remove residues as a result of the manufacturing process.
1.6.2 This guide does not provide information related to disinfection or disinfecting agents that might be part of a detergent formulation.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the Worl...
- Guide5 pagesEnglish language
- Guide5 pagesEnglish language
SIGNIFICANCE AND USE
3.1 The cloud point temperature is a reproducible characteristic of certain pure nonionic surfactants. It is also characteristic of certain nonionic surfactant formulated systems. This test method is appropriate for both systems.
Note 1: If the transition from a distinctly cloudy to a clear solution is not sharp, that is, if it does not take place within a range of 1°C, this test method is not appropriate.
SCOPE
1.1 This test method covers a procedure to determine the “cloud point” of nonionic surfactants or detergent systems. Cloud Point is the temperature at which dissolved components (solids or liquids) are no longer completely soluble, precipating as a second phase giving the fluid a cloudy appearance. It is limited to those surfactants and detergent systems for which the visible solubility change occurs over a range of 1°C or less at concentrations of 0.5 to 1.0 % in DI water between 30 and 95°C.
1.2 Chemical Limitations—Nonionic surfactants that exhibit a characteristic cloud point in general terms consist of a water-in-soluble moiety condensed with 50 to 75 % by weight of ethylene oxide. If the level of ethoxylation is too low the surfactant may not be water soluble at temperatures less than 30°C, and if it is too high no cloud point may exist.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard2 pagesEnglish language
- Standard2 pagesEnglish language
ABSTRACT
This test method covers the determination of the efficiency of ordinary commercial wetting agents using the skein test. It is applicable under limited and controlled conditions, but does not necessarily yield information correlating with specific end uses. The apparatus is comprised of a hook of standard weight depending on the concentration of the wetting agents and an anchor which shall be a flat, cylindrical, lead slug of specific dimensions. The reagents shall consist of water, acid and base test solutions, and wetting agent. The average of at least four determinations of the sinking time for each concentration of wetting agent shall be obtained and presented in plots with logarithmic coordinates. Standard deviation based on six replicate determinations shall also be calculated for precision.
SCOPE
1.1 This test method2,3 covers the determination of the efficiency of ordinary commercial wetting agents as defined in Terminology D459. This test method is applicable under limited and controlled conditions, but does not necessarily yield information correlating with specific end uses.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard3 pagesEnglish language
- Standard3 pagesEnglish language
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The guide can be used to compare anti-redeposition performance of products; however, there is no confirmed basis for correlation of this controlled laboratory technique with consumers’ ranking of anti-redeposition performance.
SCOPE
1.1 This guide provides direction for measuring the ability of detergents to prevent the deposition of soils from detergent solutions onto fabrics. It is intended as a laboratory screening test to aid in the formulation of detergent products, for quality control, and as a basis between the purchaser and seller in standardizing specific products' performance.
1.2 The anti-soil deposition performance of detergent products will vary greatly depending on the type of soils and fabrics used in the test. Therefore, selection of the soils, fabrics, reference detergents, and test conditions shall be made by agreement between the interested parties on the basis of experience.
1.3 There is no single or combination of oily soils or particulate soils, or both, that will precisely predict overall the performance of a product or treatment with respect to anti-redeposition as perceived by a consumer. This guide is intended to assess or compare detergent performance with respect to the anti-redeposition performance for the specific soil chosen.
1.4 The values stated in either inch-pound or SI units are to be regarded separately as the standard. The values given in parentheses are for information only.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Material safety data sheets are available for reagents and materials. Review them for hazards prior to usage.
- Guide4 pagesEnglish language
- Guide4 pagesEnglish language
ABSTRACT
This guide details the standard procedures for the preparation of aqueous solutions of soaps and detergents and the determination of their pH. The required reagent for this procedure is distilled water or its equivalent, and the recommended electrodes for the determination of pH are the Fischer Accuphast combination electrode or Orion Ross Sure Flow electrode or their equivalents.
SCOPE
1.1 This guide covers the preparation of aqueous solutions of soaps and detergents and the determination of their pH.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Material Safety Data Sheets are available for reagents and materials. Review them for hazards prior to usage.
- Guide2 pagesEnglish language
- Guide2 pagesEnglish language
- Guide2 pagesEnglish language
SIGNIFICANCE AND USE
4.1 The guide, as now constituted, is not suitable for ranking of detergent products since no basis is available at this time for correlation of the detergency performance of any particular soiled cloth or clothes with detergency of naturally soiled articles.
4.2 A suggested procedure for comparing the performance of any two laundry detergents on naturally soiled family items in home laundry equipment under controlled conditions on a paired comparison basis is described in Method D2960.
SCOPE
1.1 This is a guide for measuring the ability of detergents to remove artificially applied soils from fabrics. It is intended as a laboratory screening test to aid in the formulation of detergent products, for quality control and as a basis between the purchaser and seller in standardizing specific products' performance.
1.2 The relative ranking of detergent products will vary greatly depending on the type of soiled fabrics used in the test. Therefore, selection of the standard soiled fabric to be used in a test shall be made by agreement between the interested parties on the basis of experience.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Guide2 pagesEnglish language
- Guide2 pagesEnglish language
- Guide2 pagesEnglish language
ABSTRACT
This test method covers the determination of foaming properties of surface-active agents. Glass tubing apparatus for this test method shall include pipet and a receiver. Apparatus requirements like dimensions, shape, calibration marks, rubber stoppers, etc., shall conform to the specifications as indicated in this standard method. Test solution preparation shall include water preheating, adding the surface-active agent while stirring, and solution aging. Test procedure for foaming properties determination shall be done while surface-active solution is aging as indicated in this standard test method. Report shall include test solution concentration, temperature, water hardness, and foam height.
SCOPE
1.1 This test method covers the determination of the foaming properties of surface-active agents as defined in Terminology D459. This test method is applicable under limited and controlled conditions, but does not necessarily yield information correlating with specific end uses.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard3 pagesEnglish language
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The methods in this guide can be used for screening of fabric softener products or to evaluate their performance, through a single cycle or multiple accumulative cycles, relative to a designated reference product or a comparative product(s).
5.2 A single assessment of each of the product characteristics tested by these methods will not predict overall performance of the softener product. A single test run under specified fixed conditions cannot be expected to reflect the comparative performance under many other possible conditions of use.
SCOPE
1.1 This guide evaluates the performance characteristics of fabric softener products. It provides guidance for evaluating the on fabric efficacy of treatment chemicals dosed into the wash, rinse, or dryer cycle in a home laundry washer or dryer. This guide can be used for screening of fabric softener products, or to evaluate the products through multiple accumulative cycles.
1.2 The relative ranking of products assessed by these procedures may be affected by such factors as machine type and settings, fabric load composition, as well as by the washing and drying procedures used.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Guide7 pagesEnglish language
- Guide7 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This guide suggests a number of staining agents that are representative of stains commonly encountered in household laundry. The assessment need not be limited to this suggested list of stains, especially if special product types or end uses are being evaluated. This guide can be used to compare stain removal performance of products; however, there is no confirmed basis for correlation of this controlled laboratory technique with consumers’ ranking of stain removal performance.
5.2 The evaluations generated by this guide should be regarded as diagnostic screening tests that are useful in formulation studies, quality control, and ingredient raw material qualification. This guide provides considerable flexibility in choosing specific stains, washing conditions, and laboratory equipment appropriate to the objective of the evaluation. This procedural latitude may result in a reduced level of interlaboratory precision and such comparison of results must be evaluated with caution.
5.3 The procedure is applicable to all types of home laundry products including detergents, presoak and prespotter products, bleaches, and detergent boosters and is expected to be applicable to horizontal and vertical axis machines.
5.4 It is not intended for the evaluation of products or conditions normally associated with commercial laundering or dry cleaning establishments.
SCOPE
1.1 This is a guide for evaluating stain removal performance of home laundry products or home laundering conditions. It provides guidance for the selection, preparation, application, and examination of various types of stains on test fabrics that are subjected to controlled but practical stain removal treatment conditions.
1.2 There is no single combination of stain and fabric that will predict the overall performance of a product or treatment method. A single test, even with a variety of stains/fabrics, can only predict how products or treatment methods compare under the particular conditions chosen for evaluations. A series of assessments is necessary to evaluate the many aspects of stain removal performance and to simulate consumer experience more closely.
1.3 In this guide, the use of both traditional top-loader washing machines as well as front and top-loading high-efficiency washers is addressed.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Guide8 pagesEnglish language
- Guide8 pagesEnglish language
ABSTRACT
This guide covers the evaluation of the effect of dyestuff color transfer or color loss from dyed fabrics. It is designed as a laboratory screening test to aid in the formulation of detergent products or the comparison of two or more detergents, it is not suitable for detergent or washing machine rankings. The apparatus and materials use in evaluating color transfer or color loss of dyed fabrics are presented in details. The procedure for color transfer in one wash, and color loss in three washes are presented in details.
SCOPE
1.1 This guide covers the evaluation of the effect of dyestuff color transfer or color loss from dyed fabrics. It is designed as a laboratory screening test to aid in the formulation of detergent products or the comparison of two or more detergents.
1.2 There is no single assessment that will give the overall performance of a laundry product. A single test can only suggest how a formulation performs under the particular conditions chosen for the evaluation and cannot be expected to reflect comparative product performance under the many other possible conditions of use. A series of assessments is always necessary in order to evaluate the many aspects of product performance. It is necessary to conduct confirming tests under controlled but practical home-laundering conditions to simulate consumer experience.
1.3 The values stated in either inch-pound or SI units are to be regarded separately as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Guide3 pagesEnglish language
- Guide3 pagesEnglish language
ABSTRACT
This test method covers the determination of the efficiency of ordinary commercial wetting agents using the skein test. It is applicable under limited and controlled conditions, but does not necessarily yield information correlating with specific end uses. The apparatus is comprised of a hook of standard weight depending on the concentration of the wetting agents and an anchor which shall be a flat, cylindrical, lead slug of specific dimensions. The reagents shall consist of water, acid and base test solutions, and wetting agent. The average of at least four determinations of the sinking time for each concentration of wetting agent shall be obtained and presented in plots with logarithmic coordinates. Standard deviation based on six replicate determinations shall also be calculated for precision.
SCOPE
1.1 This test method , covers the determination of the efficiency of ordinary commercial wetting agents as defined in Terminology D459. This test method is applicable under limited and controlled conditions, but does not necessarily yield information correlating with specific end uses.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard3 pagesEnglish language
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
The cloud point temperature is a reproducible characteristic of certain pure nonionic surfactants. It is also characteristic of certain nonionic surfactant formulated systems. This test method is appropriate for both systems.
Note 1—If the transition from a distinctly cloudy to a clear solution is not sharp, that is, if it does not take place within a range of 1°C, this test method is not appropriate.
SCOPE
1.1 This test method covers a procedure to determine the “cloud point” of nonionic surfactants or detergent systems. Cloud Point is the temperature at which dissolved components (solids or liquids) are no longer completely soluble, precipating as a second phase giving the fluid a cloudy appearance. It is limited to those surfactants and detergent systems for which the visible solubility change occurs over a range of 1°C or less at concentrations of 0.5 to 1.0 % in DI water between 30 and 95°C.
1.2 Chemical Limitations—Nonionic surfactants that exhibit a characteristic cloud point in general terms consist of a water-in-soluble moiety condensed with 50 to 75 % by weight of ethylene oxide. If the level of ethoxylation is too low the surfactant may not be water soluble at temperatures less than 30°C, and if it is too high no cloud point may exist.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard2 pagesEnglish language
- Standard2 pagesEnglish language
SIGNIFICANCE AND USE
The test as now constituted is not suitable for ranking of detergent products, since no basis is available at this time for correlation of the anti-deposition performance of detergents using any particular combination of soils and fabrics with anti-redeposition performance during washing of naturally soiled articles.
A suggested procedure for comparing the performance of any two laundry detergents or naturally soiled family items in home laundry equipment, under controlled conditions on a paired comparison basis, is described in Method D2960.
SCOPE
1.1 This test method provides guidelines for measuring the ability of detergents to prevent the deposition of soils from detergent solutions onto fabrics. It is intended as a laboratory screening test to aid in the formulation of detergent products, for quality control, and as a basis between the purchaser and seller in standardizing specific products' performance.
1.2 The anti-soil deposition performance of detergent products will vary greatly depending on the type of soils and fabrics used in the test. Therefore, selection of the soils, fabrics, reference detergents, and test conditions shall be made by agreement between the interested parties on the basis of experience.
1.3 The values stated in either inch-pound or SI units are to be regarded separately as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Material safety data sheets are available for reagents and materials. Review them for hazards prior to usage.
- Standard3 pagesEnglish language
ABSTRACT
This test method covers the determination of foaming properties of surface-active agents. Glass tubing apparatus for this test method shall include pipet and a receiver. Apparatus requirements like dimensions, shape, calibration marks, rubber stoppers, etc., shall conform to the specifications as indicated in this standard method. Test solution preparation shall include water preheating, adding the surface-active agent while stirring, and solution aging. Test procedure for foaming properties determination shall be done while surface-active solution is aging as indicated in this standard test method. Report shall include test solution concentration, temperature, water hardness, and foam height.
SCOPE
1.1 This test method covers the determination of the foaming properties of surface-active agents as defined in Terminology D 459. This test method is applicable under limited and controlled conditions, but does not necessarily yield information correlating with specific end uses.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard3 pagesEnglish language
- Standard3 pagesEnglish language
ABSTRACT
This guide details the standard procedures for the preparation of aqueous solutions of soaps and detergents and the determination of their pH. The required reagent for this procedure is distilled water or its equivalent, and the recommended electrodes for the determination of pH are the Fischer Accuphast combination electrode or Orion Ross Sure Flow electrode or their equivalents.
SCOPE
1.1 This guide covers the preparation of aqueous solutions of soaps and detergents and the determination of their pH.
1.2 The values stated in SI units are to be regarded as the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Material Safety Data Sheets are available for reagents and materials. Review them for hazards prior to usage.
- Guide2 pagesEnglish language
SIGNIFICANCE AND USE
The guide, as now constituted, is not suitable for ranking of detergent products since no basis is available at this time for correlation of the detergency performance of any particular soiled cloth or clothes with detergency of naturally soiled articles.
A suggested procedure for comparing the performance of any two laundry detergents on naturally soiled family items in home laundry equipment under controlled conditions on a paired comparison basis is described in Method D 2960.
SCOPE
1.1 This is a guide for measuring the ability of detergents to remove artificially applied soils from fabrics. It is intended as a laboratory screening test to aid in the formulation of detergent products, for quality control and as a basis between the purchaser and seller in standardizing specific products' performance.
1.2 The relative ranking of detergent products will vary greatly depending on the type of soiled fabrics used in the test. Therefore, selection of the standard soiled fabric to be used in a test shall be made by agreement between the interested parties on the basis of experience.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Guide2 pagesEnglish language
SCOPE
1.1 This is a guide for evaluating stain removal performance of home laundry products or home laundering conditions. It provides guidance for the selection, preparation, application, and examination of various types of stains on test fabrics that are subjected to controlled but practical stain removal treatment conditions.
1.2 There is no single type of stain that will predict the overall performance of a product or treatment method. A single test, even with a variety of stains, can only predict how products or treatment methods compare under the particular conditions chosen for evaluation. A series of assessments is necessary to evaluate the many aspects of stain removal performance and to simulate consumer experience more closely.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Guide6 pagesEnglish language
SCOPE
1.1 This is a guide for measuring the ability of detergents to remove artificially applied soils from fabrics. It is intended as a laboratory screening test to aid in the formulation of detergent products, for quality control and as a basis between the purchaser and seller in standardizing specific products' performance.
1.2 The relative ranking of detergent products will vary greatly depending on the type of soiled fabrics used in the test. Therefore, selection of the standard soiled fabric to be used in a test shall be made by agreement between the interested parties on the basis of experience.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Guide2 pagesEnglish language
SCOPE
1.1 This is a guide for measuring the ability of detergents to remove artificially applied soils from fabrics. It is intended as a laboratory screening test to aid in the formulation of detergent products, for quality control and as a basis between the purchaser and seller in standardizing specific products' performance.
1.2 The relative ranking of detergent products will vary greatly depending on the type of soiled fabrics used in the test. Therefore, selection of the standard soiled fabric to be used in a test shall be made by agreement between the interested parties on the basis of experience.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Guide2 pagesEnglish language
ABSTRACT
This test method covers the determination of the efficiency of ordinary commercial wetting agents using the skein test. It is applicable under limited and controlled conditions, but does not necessarily yield information correlating with specific end uses. The apparatus is comprised of a hook of standard weight depending on the concentration of the wetting agents and an anchor which shall be a flat, cylindrical, lead slug of specific dimensions. The reagents shall consist of water, acid and base test solutions, and wetting agent. The average of at least four determinations of the sinking time for each concentration of wetting agent shall be obtained and presented in plots with logarithmic coordinates. Standard deviation based on six replicate determinations shall also be calculated for precision.
SCOPE
1.1 This test method2,3 covers the determination of the efficiency of ordinary commercial wetting agents as defined in Terminology D 459. This test method is applicable under limited and controlled conditions, but does not necessarily yield information correlating with specific end uses.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard4 pagesEnglish language
SCOPE
1.1 This is a guide for measuring the ability of detergents to remove artificially applied soils from fabrics. It is intended as a laboratory screening test to aid in the formulation of detergent products, for quality control and as a basis between the purchaser and seller in standardizing specific products' performance.
1.2 The relative ranking of detergent products will vary greatly depending on the type of soiled fabrics used in the test. Therefore, selection of the standard soiled fabric to be used in a test shall be made by agreement between the interested parties on the basis of experience.
1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Guide2 pagesEnglish language
SCOPE
1.1 This is a guide for evaluating stain removal performance of home laundry products or home laundering conditions. It provides guidance for the selection, preparation, application, and examination of various types of stains on test fabrics that are subjected to controlled but practical stain removal treatment conditions.
1.2 There is no single type of stain that will predict the overall performance of a product or treatment method. A single test, even with a variety of stains, can only predict how products or treatment methods compare under the particular conditions chosen for evaluation. A series of assessments is necessary to evaluate the many aspects of stain removal per- formance and to simulate consumer experience more closely.
1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of whoever uses this standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Guide6 pagesEnglish language
SCOPE
1.1 This method 2,3 covers the determination of the efficiency of ordinary commercial wetting agents as defined in Definitions D459. This method is applicable under limited and controlled conditions, but does not necessarily yield information correlating with specific end uses.
1.2 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.>
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
The test as now constituted is not suitable for ranking of detergent products, since no basis is available at this time for correlation of the anti-deposition performance of detergents using any particular combination of soils and fabrics with anti-redeposition performance during washing of naturally soiled articles.
A suggested procedure for comparing the performance of any two laundry detergents or naturally soiled family items in home laundry equipment, under controlled conditions on a paired comparison basis, is described in Method D 2960.
SCOPE
1.1 This test method provides guidelines for measuring the ability of detergents to prevent the deposition of soils from detergent solutions onto fabrics. It is intended as a laboratory screening test to aid in the formulation of detergent products, for quality control, and as a basis between the purchaser and seller in standardizing specific products' performance.
1.2 The anti-soil deposition performance of detergent products will vary greatly depending on the type of soils and fabrics used in the test. Therefore, selection of the soils, fabrics, reference detergents, and test conditions shall be made by agreement between the interested parties on the basis of experience.
1.3 The values stated in either inch-pound or SI units are to be regarded separately as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Material safety data sheets are available for reagents and materials. Review them for hazards prior to usage.
- Standard3 pagesEnglish language
SCOPE
1.1 This guide covers the preparation of aqueous solutions of soaps and detergents and the determination of their pH.
1.2 The values stated in SI units are to be regarded as the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Material Safety Data Sheets are available for reagents and materials. Review them for hazards prior to usage.
- Guide2 pagesEnglish language
SCOPE
1.1 This guide covers the preparation of aqueous solutions of soaps and detergents and the determination of their pH.
1.2 The values stated in SI units are to be regarded as the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Material Safety Data Sheets are available for reagents and materials. Review them for hazards prior to usage.
- Guide2 pagesEnglish language
SCOPE
1.1 This test method provides guidelines for measuring the ability of detergents to prevent the deposition of soils from detergent solutions onto fabrics. It is intended as a laboratory screening test to aid in the formulation of detergent products, for quality control, and as a basis between the purchaser and seller in standardizing specific products' performance.
1.2 The anti-soil deposition performance of detergent products will vary greatly depending on the type of soils and fabrics used in the test. Therefore, selection of the soils, fabrics, reference detergents, and test conditions shall be made by agreement between the interested parties on the basis of experience.
1.3 The values stated in either inch-pound or SI units are to be regarded separately as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Material safety data sheets are available for reagents and materials. Review them for hazards prior to usage.
- Standard3 pagesEnglish language
SCOPE
1.1 This test method covers the determination of the solubility inversion temperature or "cloud point" of nonionic surfactants or detergent systems which are characteristically less soluble in water at higher temperatures than at lower temperatures. It is limited to those surfactants and detergent systems for which the visible solubility change occurs over a range of 1°C or less at concentrations of 0.5 to 1.0 % in water between 30 and 95°C.
1.2 Chemical Limitations -Nonionic surfactants that exhibit a characteristic cloud point in general terms consist of a water-in-soluble moiety condensed with 50 to 75 % by weight of ethylene oxide.
1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.>
- Standard1 pageEnglish language
SIGNIFICANCE AND USE
The cloud point temperature is a reproducible characteristic of certain pure nonionic surfactants. It is also characteristic of certain nonionic surfactant formulated systems. This test method is appropriate for both systems.
Note 1—If the transition from a distinctly cloudy to a clear solution is not sharp, that is, if it does not take place within a range of 1°C, this test method is not appropriate.
SCOPE
1.1 This test method covers the determination of the solubility inversion temperature or "cloud point" of nonionic surfactants or detergent systems which are characteristically less soluble in water at higher temperatures than at lower temperatures. It is limited to those surfactants and detergent systems for which the visible solubility change occurs over a range of 1°C or less at concentrations of 0.5 to 1.0 % in water between 30 and 95°C.
1.2 Chemical LimitationsNonionic surfactants that exhibit a characteristic cloud point in general terms consist of a water-in-soluble moiety condensed with 50 to 75 % by weight of ethylene oxide.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard2 pagesEnglish language
SCOPE
1.1 This test method covers the determination of the foaming properties of surface-active agents as defined in Terminology D459. This test method is applicable under limited and controlled conditions, but does not necessarily yield information correlating with specific end uses.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard2 pagesEnglish language
SCOPE
1.1 This test method covers the determination of the foaming properties of surface-active agents as defined in Terminology D459. This test method is applicable under limited and controlled conditions, but does not necessarily yield information correlating with specific end uses.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard2 pagesEnglish language
Frequently Asked Questions
D12.15 is a Technical Committee within ASTM International. It is named "Physical Testing". This committee has published 43 standards.
D12.15 develops ASTM standards in the area of Information technology. Currently, there are 43 published standards from this technical committee.
ASTM is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.
A Technical Committee (TC) in ASTM is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.