Standard Test Method for Fluorescent Liquid Penetrant Examination Using the Hydrophilic Post-Emulsification Process

SIGNIFICANCE AND USE
Liquid penetrant examination methods indicate the presence, location, and, to a limited extent, the nature and magnitude of the detected discontinuities. This test method is normally used for production examination of critical components, where reproducibility is essential. More procedural controls and processing steps are required than with other processes.
SCOPE
1.1 This test method covers procedures for fluorescent penetrant examination utilizing the hydrophilic post-emulsification process. It is a nondestructive testing method for detecting discontinuities that are open to the surface such as cracks, seams, laps, cold shuts, laminations, isolated porosity, through leaks, or lack of fusion and is applicable to in-process, final, and maintenance examination. It can be effectively used in the examination of nonporous, metallic materials, both ferrous and nonferrous, and of nonmetallic materials such as glazed or fully densified ceramics and certain nonporous plastics and glass.
1.2 This test method also provides a reference:
1.2.1 By which a fluorescent penetrant examination hydrophilic post-emulsification process recommended or required by individual organizations can be reviewed to ascertain their applicability and completeness.
1.2.2 For use in the preparation of process specifications dealing with the fluorescent penetrant examination of materials and parts using the hydrophilic post-emulsification process. Agreement by the purchaser and the manufacturer regarding specific techniques is strongly recommended.
1.2.3 For use in the organization of the facilities and personnel concerned with the liquid penetrant examination.
1.3 This test method does not indicate or suggest standards for evaluation of the indications obtained. It should be pointed out, however, that indications must be interpreted or classified and then evaluated. For this purpose there must be a separate code or specification or a specific agreement to define the type, size, location, and direction of indications considered acceptable, and those considered unacceptable.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.4 All areas of this test method may be open to agreement between the cognizant engineering organization and the supplier, or specific direction from the cognizant engineering organization.

General Information

Status
Historical
Publication Date
31-Dec-2004
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM E1210-05 - Standard Test Method for Fluorescent Liquid Penetrant Examination Using the Hydrophilic Post-Emulsification Process
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information.
Designation: E1210 – 05
Standard Test Method for
Fluorescent Liquid Penetrant Examination Using the
1
Hydrophilic Post-Emulsification Process
This standard is issued under the fixed designation E1210; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 1.5 All areas of this test method may be open to agreement
between the cognizant engineering organization and the sup-
1.1 This test method covers procedures for fluorescent
plier, or specific direction from the cognizant engineering
penetrant examination utilizing the hydrophilic post-
organization.
emulsificationprocess.Itisanondestructivetestingmethodfor
detecting discontinuities that are open to the surface such as
2. Referenced Documents
cracks, seams, laps, cold shuts, laminations, isolated porosity,
2
2.1 ASTM Standards:
through leaks, or lack of fusion and is applicable to in-process,
D129 Test Method for Sulfur in Petroleum Products (Gen-
final, and maintenance examination. It can be effectively used
eral Bomb Method)
in the examination of nonporous, metallic materials, both
D516 Test Method for Sulfate Ion in Water
ferrous and nonferrous, and of nonmetallic materials such as
D808 TestMethodforChlorineinNewandUsedPetroleum
glazed or fully densified ceramics and certain nonporous
Products (Bomb Method)
plastics and glass.
D1552 Test Method for Sulfur in Petroleum Products
1.2 This test method also provides a reference:
(High-Temperature Method)
1.2.1 By which a fluorescent penetrant examination hydro-
E165 PracticeforLiquidPenetrantExaminationforGeneral
philic post-emulsification process recommended or required by
Industry
individual organizations can be reviewed to ascertain their
E433 Reference Photographs for Liquid Penetrant Inspec-
applicability and completeness.
tion
1.2.2 For use in the preparation of process specifications
E543 Specification for Agencies Performing Nondestruc-
dealing with the fluorescent penetrant examination of materials
tive Testing
and parts using the hydrophilic post-emulsification process.
E1316 Terminology for Nondestructive Examinations
Agreement by the purchaser and the manufacturer regarding
2.2 ASNT Documents:
specific techniques is strongly recommended.
Recommended Practice SNT-TC-1A Personnel Qualifica-
1.2.3 For use in the organization of the facilities and
3
tion and Certification in Nondestructive Testing
personnel concerned with the liquid penetrant examination.
ANSI/ASNT-CP-189 Standard for Qualification and Certi-
1.3 This test method does not indicate or suggest standards
3
fication of Nondestructive Testing Personnel
for evaluation of the indications obtained. It should be pointed
2.3 Military Standard:
out, however, that indications must be interpreted or classified
MIL-STD-410 Nondestructive Testing Personnel Qualifica-
and then evaluated. For this purpose there must be a separate
4
tion and Certification
code or specification or a specific agreement to define the type,
2.4 AIA Standard:
size, location, and direction of indications considered accept-
NAS 410 Certification and Qualification of Nondestructive
able, and those considered unacceptable.
5
Testing Personnel
1.4 This standard does not purport to address all of the
2.5 DoD Contracts—Unless otherwise specified, the issue
safety concerns, if any, associated with its use. It is the
of the documents that are DoD adopted are those listed in
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use. 2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
1 3
This test method is under the jurisdiction of ASTM Committee E07 on Available fromTheAmerican Society for NondestructiveTesting (ASNT), P.O.
Nondestructive Testing and is the direct responsibility of Subcommittee E07.03 on Box 28518, 1711 Arlingate Lane, Columbus, OH 43228-0518.
4
Liquid Penetrant and Magnetic Particle Methods. AvailablefromStandardizationDocumentsOrderDesk,Bldg.4SectionD,700
Current edition approved January 1, 2005. Published January 2005. Originally Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.
5
approved in 1987. Last previous edition approved in 1999 as E1210 - 99. DOI: Available from the Aerospace Industries Association of America, Inc., 1250
10.1520/E1210-05. Eye St., N.W., Washington, DC 20005.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocke
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.