ASTM C1107/C1107M-13
(Specification)Standard Specification for Packaged Dry, Hydraulic-Cement Grout (Nonshrink)
Standard Specification for Packaged Dry, Hydraulic-Cement Grout (Nonshrink)
ABSTRACT
This specification covers packaged dry, hydraulic cement grout (nonshrink) intended for use under applied load where a change in height below initial placement height is to be avoided. Grouts covered are composed of hydraulic cement, fine aggregate, and other ingredients. They require only the addition of mixing water for use. The materials used as ingredients in packaged, dry, grout include hydraulic cement, fine aggregate, and other ingredients. The performance requirements of the specimens are presented in details. Grout mixtures shall be produced using the conditions prescribed. For smaller quantities of grout, the mortar-mixing apparatus shall be as specified. Mixer for grout performance qualifications shall be clean, pre-wetted, and drained and essentially free of hardened mortar and other foreign material that can be removed with a trowel or by reasonably striking with a hammer. The procedures for preliminary adjustment mixing and grout performance qualification are presented in details. Consistency testing shall be performed on the grout mixture. Determine the yield of the grout using the 400-mL cylindrical measure described.
SCOPE
1.1 This specification covers packaged dry, hydraulic cement grout (nonshrink) intended for use under applied load (such as to support a structure, a machine, and the like) where a change in height below initial placement height is to be avoided.
1.2 Grouts covered are composed of hydraulic cement, fine aggregate, and other ingredients. They require only the addition of mixing water for use.
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.4 The following safety hazards caveat pertains only to the test method portion of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C1107/C1107M −13
StandardSpecification for
1
Packaged Dry, Hydraulic-Cement Grout (Nonshrink)
ThisstandardisissuedunderthefixeddesignationC1107/C1107M;thenumberimmediatelyfollowingthedesignationindicatestheyear
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* Hydraulic-Cement Mortar and Concrete
C185 Test Method for Air Content of Hydraulic Cement
1.1 This specification covers packaged dry, hydraulic ce-
Mortar
ment grout (nonshrink) intended for use under applied load
C305 Practice for Mechanical Mixing of Hydraulic Cement
(such as to support a structure, a machine, and the like) where
Pastes and Mortars of Plastic Consistency
a change in height below initial placement height is to be
C702 PracticeforReducingSamplesofAggregatetoTesting
avoided.
Size
1.2 Grouts covered are composed of hydraulic cement, fine
C827 Test Method for Change in Height at Early Ages of
aggregate, and other ingredients. They require only the addi-
Cylindrical Specimens of Cementitious Mixtures
tion of mixing water for use.
C939 Test Method for Flow of Grout for Preplaced-
1.3 The values stated in either SI units or inch-pound units Aggregate Concrete (Flow Cone Method)
C1090 Test Method for Measuring Changes in Height of
are to be regarded separately as standard. The values stated in
each system may not be exact equivalents; therefore, each Cylindrical Specimens of Hydraulic-Cement Grout
C1437 Test Method for Flow of Hydraulic Cement Mortar
system shall be used independently of the other. Combining
values from the two systems may result in non-conformance
with the standard. 3. Terminology
1.4 The following safety hazards caveat pertains only to the
3.1 Definitions—For definitions of terms used in this
test method portion of this specification: This standard does
specification, refer to Terminology C125.
not purport to address all of the safety concerns, if any,
3.2 Definitions of Terms Specific to This Standard:
associated with its use. It is the responsibility of the user of this
3.2.1 consistency, flowable, n—a grout consistency having a
standard to establish appropriate safety and health practices
flow of 125 to 145 by the flow test in accordance with the
and determine the applicability of regulatory limitations prior
applicable provisions of Test Method C1437; the flow after 5
to use.
drops of the flow table in 3 s.
2. Referenced Documents 3.2.2 consistency, fluid, n—a grout consistency having a
2
time of efflux of 10 to 30 s when tested by the flow cone
2.1 ASTM Standards:
procedure of Test Method C939.
C109/C109M Test Method for Compressive Strength of
Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube 3.2.3 consistency, plastic, n—a grout consistency having a
Specimens) flow of 100 to 125 by the flow test in accordance with the
C125 Terminology Relating to Concrete and Concrete Ag- applicable provisions of Test Method C1437; the flow after 5
gregates drops of the flow table in 3 s.
C138/C138M Test Method for Density (Unit Weight),Yield,
and Air Content (Gravimetric) of Concrete 4. Ordering Information
C157/C157M Test Method for Length Change of Hardened
4.1 When the purchaser specifies that properties of the
packaged,drygroutmeettherequirementsofthisspecification,
also specify which, if any, of the optional requirements apply.
1
This specification is under the jurisdiction of ASTM Committee C09 on
Concrete and Concrete Aggregatesand is the direct responsibility of Subcommittee
4.2 When the grout is to be used in contact with stressed
C09.43 on Packaged Dry Combined Materials.
tendons or other corrosion-sensitive, load-bearing structural
CurrenteditionapprovedMay1,2013.PublishedJuly2013.Originallyapproved
members, the purchaser shall supply this information to the
in 1991. Last previous edition approved in 2011 as C1107/C1107M–11. DOI:
10.1520/C1107_C1107M-13.
manufacturer and obtain assurances that the material meets
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
relevant chloride, nitrite, nitrate, sulfide, and sulfate
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
requirements, and any other material limitations imposed by
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. the applicable codes and standards (See Note 1).
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
C1107/C1107M−13
4.3 When the grout is to be used in abnormal or aggressive 7. Sampling
environments, the purchaser shall suppl
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C1107/C1107M − 11 C1107/C1107M − 13
Standard Specification for
1
Packaged Dry, Hydraulic-Cement Grout (Nonshrink)
This standard is issued under the fixed designation C1107/C1107M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope*
1.1 This specification covers packaged dry, hydraulic cement grout (nonshrink) intended for use under applied load (such as to
support a structure, a machine, and the like) where a change in height below initial placement height is to be avoided.
1.2 Grouts covered are composed of hydraulic cement, fine aggregate, and other ingredients. They require only the addition of
mixing water for use.
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each
system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the
two systems may result in non-conformance with the standard.
1.4 The following safety hazards caveat pertains only to the test method portion of this specification: This standard does not
purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to
establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
C109/C109M Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
C125 Terminology Relating to Concrete and Concrete Aggregates
C138/C138M Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
C157/C157M Test Method for Length Change of Hardened Hydraulic-Cement Mortar and Concrete
C185 Test Method for Air Content of Hydraulic Cement Mortar
C305 Practice for Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic Consistency
C702 Practice for Reducing Samples of Aggregate to Testing Size
C827 Test Method for Change in Height at Early Ages of Cylindrical Specimens of Cementitious Mixtures
C939 Test Method for Flow of Grout for Preplaced-Aggregate Concrete (Flow Cone Method)
C1090 Test Method for Measuring Changes in Height of Cylindrical Specimens of Hydraulic-Cement Grout
C1437 Test Method for Flow of Hydraulic Cement Mortar
3. Terminology
3.1 Definitions—For definitions of terms used in this specification, refer to Terminology C125.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 consistency, flowable, n—a grout consistency having a flow of 125 to 145 by the flow test in accordance with the
applicable provisions of Test Method C1437; the flow after 5 drops of the flow table in 3 s.
3.2.2 consistency, fluid, n—a grout consistency having a time of efflux of 10 to 30 s when tested by the flow cone procedure
of Test Method C939.
3.2.3 consistency, plastic, n—a grout consistency having a flow of 100 to 125 by the flow test in accordance with the applicable
provisions of Test Method C1437; the flow after 5 drops of the flow table in 3 s.
1
This specification is under the jurisdiction of ASTM Committee C09 on Concrete and Concrete Aggregatesand is the direct responsibility of Subcommittee C09.43 on
Packaged Dry Combined Materials.
Current edition approved April 1, 2011May 1, 2013. Published April 2011July 2013. Originally approved in 1991. Last previous edition approved in 20082011 as
C1107/C1107M–08.–11. DOI: 10.1520/C1107_C1107M-11.10.1520/C1107_C1107M-13.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
C1107/C1107M − 13
4. Ordering Information
4.1 When the purchaser specifies that properties of the packaged, dry grout meet the requirements of this specification, also
specify which, if any, of the optional requirements apply.
4.2 When the grout is to be used in cont
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.