ASTM D5708-12e1
(Test Method)Standard Test Methods for Determination of Nickel, Vanadium, and Iron in Crude Oils and Residual Fuels by Inductively Coupled Plasma (ICP) Atomic Emission Spectrometry
Standard Test Methods for Determination of Nickel, Vanadium, and Iron in Crude Oils and Residual Fuels by Inductively Coupled Plasma (ICP) Atomic Emission Spectrometry
SIGNIFICANCE AND USE
4.1 These test methods cover, in single procedures, the determination of Ni, V, and Fe in crude oils and residual oils. These test methods complement Test Method D1548, which covers only the determination of vanadium.
4.2 When fuels are combusted, vanadium present in the fuel can form corrosive compounds. The value of crude oils can be determined, in part, by the concentrations of nickel, vanadium, and iron. Nickel and vanadium, present at trace levels in petroleum fractions, can deactivate catalysts during processing. These test methods provide a means of determining the concentrations of nickel, vanadium, and iron.
SCOPE
1.1 These test methods cover the determination of nickel, vanadium, and iron in crude oils and residual fuels by inductively coupled plasma (ICP) atomic emission spectrometry. Two different test methods are presented.
1.2 Test Method A (Sections 7 – 11 and 18 – 22)—ICP is used to analyze a sample dissolved in an organic solvent. This test method uses oil-soluble metals for calibration and does not purport to quantitatively determine or detect insoluble particulates.
1.3 Test Method B (Sections 12 – 22)—ICP is used to analyze a sample that is decomposed with acid.
1.4 The concentration ranges covered by these test methods are determined by the sensitivity of the instruments, the amount of sample taken for analysis, and the dilution volume. A specific statement is given in 15.2. Typically, the low concentration limits are a few tenths of a mg/kg. Precision data are provided for the concentration ranges specified in Section 21.
1.5 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
´1
Designation: D5708 − 12
StandardTest Methods for
Determination of Nickel, Vanadium, and Iron in Crude Oils
and Residual Fuels by Inductively Coupled Plasma (ICP)
1
Atomic Emission Spectrometry
This standard is issued under the fixed designation D5708; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1
ε NOTE—Subsection X1.5 was corrected editorially in May 2015.
1. Scope* 2. Referenced Documents
2
2.1 ASTM Standards:
1.1 These test methods cover the determination of nickel,
D1193 Specification for Reagent Water
vanadium, and iron in crude oils and residual fuels by
1
D1548 Test Method for Vanadium in Heavy Fuel Oil
inductively coupled plasma (ICP) atomic emission spectrom-
3
(Withdrawn 1997)
etry. Two different test methods are presented.
D4057 Practice for Manual Sampling of Petroleum and
1.2 Test Method A (Sections 7–11 and 18–22)—ICP is
Petroleum Products
used to analyze a sample dissolved in an organic solvent. This
D4177 Practice for Automatic Sampling of Petroleum and
test method uses oil-soluble metals for calibration and does not
Petroleum Products
purport to quantitatively determine or detect insoluble particu-
D5185 Test Method for Multielement Determination of
lates.
Used and Unused Lubricating Oils and Base Oils by
1.3 Test Method B (Sections 12–22)—ICP is used to
Inductively Coupled Plasma Atomic Emission Spectrom-
analyze a sample that is decomposed with acid.
etry (ICP-AES)
D6299 Practice for Applying Statistical Quality Assurance
1.4 The concentration ranges covered by these test methods
and Control Charting Techniques to Evaluate Analytical
are determined by the sensitivity of the instruments, the
Measurement System Performance
amount of sample taken for analysis, and the dilution volume.
D7260 Practice for Optimization, Calibration, and Valida-
A specific statement is given in 15.2. Typically, the low
tion of Inductively Coupled Plasma-Atomic Emission
concentration limits are a few tenths of a mg/kg. Precision data
Spectrometry (ICP-AES) for ElementalAnalysis of Petro-
are provided for the concentration ranges specified in Section
leum Products and Lubricants
21.
1.5 The values stated in SI units are to be regarded as 3. Summary of Test Method
standard. The values given in parentheses are for information
3.1 Test Method A—Approximately 10 g of the sample are
only.
dissolved in an organic solvent (Warning—Combustible. Va-
1.6 This standard does not purport to address all of the
por is harmful.) to give a specimen solution containing 10 %
safety concerns, if any, associated with its use. It is the (m/m) of sample. The solution is nebulized into the plasma,
responsibility of the user of this standard to establish appro-
and the intensities of the emitted light at wavelengths charac-
priate safety and health practices and determine the applica- teristic of the analytes are measured sequentially or simultane-
bility of regulatory limitations prior to use.
ously. The intensities are related to concentrations by the
appropriate use of calibration data.
1 2
These test methods are under the jurisdiction of ASTM Committee D02 on For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Petroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility of contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Subcommittee D02.03 on Elemental Analysis. Standards volume information, refer to the standard’s Document Summary page on
Current edition approved Dec. 1, 2012. Published January 2013. Originally the ASTM website.
3
approved in 1995. Last previous edition approved in 2011 as D5708–11. DOI: The last approved version of this historical standard is referenced on
10.1520/D5708-12E01. www.astm.org.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
´1
D5708 − 12
3.2 Test Method B—One to 20 g of sample are weighed into 6.2 Prior to weighing, stir the sample and manually shake
a beaker and decomposed with concentrated sulfuric acid the sample container. If the sample does not readily flow at
(Warning—Poison. Causes severe burns. Harmful or fatal if room temperature, heat the sample in a drying oven at 80°C or
swallowed or inhaled.) by heating to dryness. Great care must at another safe temperature.
be used in this decomposition because the acid fumes are
TEST METHOD A—
corrosive and the mixture is potentially flammable. The re-
ICP WITH AN ORGANIC SOLVENT SPECI
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
´1
Designation: D5708 − 12 D5708 − 12
Standard Test Methods for
Determination of Nickel, Vanadium, and Iron in Crude Oils
and Residual Fuels by Inductively Coupled Plasma (ICP)
1
Atomic Emission Spectrometry
This standard is issued under the fixed designation D5708; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1
ε NOTE—Subsection X1.5 was corrected editorially in May 2015.
1. Scope*
1.1 These test methods cover the determination of nickel, vanadium, and iron in crude oils and residual fuels by inductively
coupled plasma (ICP) atomic emission spectrometry. Two different test methods are presented.
1.2 Test Method A (Sections 7 – 11 and 18 – 22)—ICP is used to analyze a sample dissolved in an organic solvent. This test
method uses oil-soluble metals for calibration and does not purport to quantitatively determine or detect insoluble particulates.
1.3 Test Method B (Sections 12 – 22) —ICP is used to analyze a sample that is decomposed with acid.
1.4 The concentration ranges covered by these test methods are determined by the sensitivity of the instruments, the amount
of sample taken for analysis, and the dilution volume. A specific statement is given in 15.2. Typically, the low concentration limits
are a few tenths of a mg/kg. Precision data are provided for the concentration ranges specified in Section 21.
1.5 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
D1193 Specification for Reagent Water
1 3
D1548 Test Method for Vanadium in Heavy Fuel Oil (Withdrawn 1997)
D4057 Practice for Manual Sampling of Petroleum and Petroleum Products
D4177 Practice for Automatic Sampling of Petroleum and Petroleum Products
D5185 Test Method for Multielement Determination of Used and Unused Lubricating Oils and Base Oils by Inductively
Coupled Plasma Atomic Emission Spectrometry (ICP-AES)
D6299 Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measure-
ment System Performance
D7260 Practice for Optimization, Calibration, and Validation of Inductively Coupled Plasma-Atomic Emission Spectrometry
(ICP-AES) for Elemental Analysis of Petroleum Products and Lubricants
3. Summary of Test Method
3.1 Test Method A—Approximately 10 g of the sample are dissolved in an organic solvent (Warning—Combustible. Vapor is
harmful.) to give a specimen solution containing 10 % (m/m) of sample. The solution is nebulized into the plasma, and the
1
These test methods are under the jurisdiction of ASTM Committee D02 on Petroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility of
Subcommittee D02.03 on Elemental Analysis.
Current edition approved Dec. 1, 2012. Published January 2013. Originally approved in 1995. Last previous edition approved in 2011 as D5708–11. DOI:
10.1520/D5708-12.10.1520/D5708-12E01.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
The last approved version of this historical standard is referenced on www.astm.org.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
´1
D5708 − 12
intensities of the emitted light at wavelengths characteristic of the analytes are measured sequentially or simultaneously. The
intensities are related to concentrations by the appropriate use of calibration data.
3.2 Test Method B—One to 20 g of sample are weighed into a beaker and decomposed with concentrated sulfuric acid
(Warning—Poison. Causes severe burns. Harmful or fatal if swallowed or inhaled.) by heating to dryness. Great care must be used
in this decomposition because the acid fumes are corrosive and the
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.