Standard Test Method for Air Permeance of Building Materials

SCOPE
1.1 This test method is to determine the air permeance of building materials at various pressure differentials with the intent of determining an assigned air permeance rate of the material at the reference pressure difference (ΔP) of 75 Pa.
1.2 The method is intended to assess flexible sheet or rigid panel-type materials using a 1 m X 1 m specimen size.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurements are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Dec-2001
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM E2178-01 - Standard Test Method for Air Permeance of Building Materials
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
Designation: E 2178 – 01
Standard Test Method for
1
Air Permeance of Building Materials
This standard is issued under the fixed designation E 2178; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 5. Sampling
1.1 This test method is to determine the air permeance of 5.1 The number of specimens to be tested must be suitable
building materials at various pressure differentials with the to establish an air leakage rate which is representative of the
intent of determining an assigned air permeance rate of the product. In no case shall less than five specimens be tested.
material at the reference pressure difference (DP)of75Pa.
NOTE 1—Because of the variability in the manufacture of a product, the
1.2 The method is intended to assess flexible sheet or rigid
number of specimens to be tested may vary from product to product.
panel-type materials usinga1m 3 1 m specimen size.
Certain materials may have standard methods for sampling that shall be
1.3 The values stated in SI units are to be regarded as used to sample these materials.
standard. No other units of measurements are included in this
6. Test Apparatus
standard.
1.4 This standard does not purport to address all of the 6.1 A schematic of the air leakage test apparatus is pre-
sented in Fig. 1.
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro- 6.1.1 Airtight Test Chamber—The airtight test chamber
shall be at least 0.32 m deep and capable of receivinga1mby
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use. 1 m test specimen, anchored to the test chamber by means of
a compression frame and clamping devices. The test chamber
2. Referenced Documents
and compression frame shall be stiff enough to limit deflection
2.1 ASTM Standards: within the operating flexibility of the gaskets used to seal the
E 283 Test Method for Rate of Air Leakage through Exte- test specimen to the chamber. Two parallel ribbons of self-
2
rior Windows, Curtain Walls and Doors adhesive gasket material shall be applied at all sealing points of
E 1677 Specification for an Air Retarder Material or System the apparatus/test specimen assembly. The gasket ribbons shall
2
for Low-Rise Framed Building Walls be made of medium-density gasket material that can be fused
or glued at joints. The test apparatus shall contain an over-
3. Terminology
pressure control device and windows to verify the specimen
3.1 Definitions:
installation.
3.1.1 air permeance—the rate of air flow (L/s), per unit area 6.1.2 Flow Measuring Devices—The flow measuring de-
2
(m ) and per unit static pressure differential (Pa). vices used to gage the air flow through the test specimen shall
-6 3
be capable of measuring air flow rate from 1 3 10 m /s (.001
4. Significance and Use -2 3
L/s) up to 1.88 3 10 m /s (18.8 L/s), with an accuracy of 6
4.1 The purpose of this test is to measure the air permeance
3 % of the reading.
of flexible or rigid sheet materials. The results of this test may
6.1.3 Pressure Measuring Devices—The static pressure dif-
be useful in determining suitability of that material as a
ferential across the test specimen shall be measured by pressure
component of an air retarder system.
measuring devices with an accuracy of 6 0.5 % of the pressure
4.2 This method does not address the installed air leakage
reading. The laboratory barometric pressure shall be measured
performance of building materials. The installed performance
with a device capable of measuring barometric pressure within
of air retarder materials and air retarder systems in low-rise
6 3 % of the reading.
framed wall construction is addressed in Specification E 1677.
6.1.4 Piping—The piping connecting the flow measuring
devices and the vacuum blower shall be airtight and contain
flow control devices to regulate the static pressure across the
1
This test method is under the jurisdiction of ASTM Committee E06 on
test specimen within 6 0.5 % of the pressure reading. The pipe
Performance of Buildings and is the direct responsibility of Subcommittee E06.41
connection to the test chamber shall contain an air filter to
on Air Leakage and Ventilation Performance.
Current edition approved Dec. 10, 2001. Published March 2002.
prevent dust or particulate matter from affecting the flow
2
Annual Book of ASTM Standards, Vol 04.11.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
NOTICE: This standard has
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.