Standard Practice for Installation of Thick Poured Lightweight Cellular Concrete Underlayments and Preparation of the Surface to Receive Resilient Flooring

SIGNIFICANCE AND USE
4.1 This practice provides minimum recommendations for the installation of thick poured lightweight cellular concrete floor underlayments suitable to receive resilient floor coverings. This practice establishes the proper preparation, installation and quality control for thick poured lightweight cellular concrete floor underlayments.  
4.2 Actual requirements for thick poured lightweight cellular concrete underlayments are generally included as part of project plans or specifications and may vary from the recommendations set forth in this practice. Project plans or specifications, or both, shall supersede the recommendations set forth in this practice.
SCOPE
1.1 This practice covers the installation and preparation of the thick poured lightweight cellular concrete underlayments over wood structural panel subfloors in commercial structures or over concrete floors in commercial structures and the preparation of the thick poured lightweight cellular concrete underlayment surface prior to the installation of resilient flooring in commercial buildings.  
1.2 This practice points out the factors that are required to be controlled while installing thick poured lightweight cellular concrete underlayment as a base for resilient flooring.  
1.3 This practice does not cover the structural adequacy of the wood structural panel subfloor or concrete subfloor. The structural integrity of assemblies is governed by local building codes.  
1.4 This practice does not supercede the thick poured lightweight cellular concrete underlayment manufacturers', adhesive manufacturers' or resilient flooring manufacturers' written instructions. Consult the individual manufacturer for specific recommendations.  
1.5 Thick poured lightweight cellular concrete underlayments are not suitable for use on concrete slabs on ground due to potential moisture problems arising from moisture intrusion, unless an adequate vapor retarder or vapor barrier is present directly beneath the concrete subfloor.  
1.6 The values stated in inch-pound units are to be regarded as standard. The values stated in parentheses are mathematical conversions to SI Units, which are provided for information only.  
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
31-Jan-2019
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM F2471-19 - Standard Practice for Installation of Thick Poured Lightweight Cellular Concrete Underlayments and Preparation of the Surface to Receive Resilient Flooring
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM F2471-19 - Standard Practice for Installation of Thick Poured Lightweight Cellular Concrete Underlayments and Preparation of the Surface to Receive Resilient Flooring
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: F2471 − 19
Standard Practice for
Installation of Thick Poured Lightweight Cellular Concrete
Underlayments and Preparation of the Surface to Receive
1
Resilient Flooring
This standard is issued under the fixed designation F2471; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope priate safety, health, and environmental practices and deter-
mine the applicability of regulatory limitations prior to use.
1.1 This practice covers the installation and preparation of
1.8 This international standard was developed in accor-
the thick poured lightweight cellular concrete underlayments
dance with internationally recognized principles on standard-
over wood structural panel subfloors in commercial structures
ization established in the Decision on Principles for the
or over concrete floors in commercial structures and the
Development of International Standards, Guides and Recom-
preparation of the thick poured lightweight cellular concrete
mendations issued by the World Trade Organization Technical
underlayment surface prior to the installation of resilient
Barriers to Trade (TBT) Committee.
flooring in commercial buildings.
2. Referenced Documents
1.2 This practice points out the factors that are required to
2
be controlled while installing thick poured lightweight cellular
2.1 ASTM Standards:
concrete underlayment as a base for resilient flooring.
C330 Specification for Lightweight Aggregates for Struc-
tural Concrete
1.3 This practice does not cover the structural adequacy of
C796 Test Method for FoamingAgents for Use in Producing
the wood structural panel subfloor or concrete subfloor. The
Cellular Concrete Using Preformed Foam
structural integrity of assemblies is governed by local building
C869 Specification for Foaming Agents Used in Making
codes.
Preformed Foam for Cellular Concrete
1.4 This practice does not supercede the thick poured
F141 Terminology Relating to Resilient Floor Coverings
lightweight cellular concrete underlayment manufacturers’,
F710 Practice for Preparing Concrete Floors to Receive
adhesive manufacturers’ or resilient flooring manufacturers’
Resilient Flooring
written instructions. Consult the individual manufacturer for
F1482 Practice for Installation and Preparation of Panel
specific recommendations.
Type Underlayments to Receive Resilient Flooring
1.5 Thick poured lightweight cellular concrete underlay-
F2170 Test Method for Determining Relative Humidity in
ments are not suitable for use on concrete slabs on ground due
Concrete Floor Slabs Using in situ Probes
to potential moisture problems arising from moisture intrusion,
F2678 Practice for Preparing Panel Underlayments, Thick
unless an adequate vapor retarder or vapor barrier is present
Poured Gypsum Concrete Underlayments, Thick Poured
directly beneath the concrete subfloor.
Lightweight Cellular Concrete Underlayments, and Con-
crete Subfloors with Underlayment Patching Compounds
1.6 The values stated in inch-pound units are to be regarded
to Receive Resilient Flooring
as standard. The values stated in parentheses are mathematical
conversions to SI Units, which are provided for information
3. Terminology
only.
3.1 Definitions used in this practice shall be in accordance
1.7 This standard does not purport to address all of the
with Terminology F141.
safety concerns, if any, associated with its use. It is the
3.2 Definitions of Terms Specific to This Standard:
responsibility of the user of this standard to establish appro-
3.2.1 fully adhered flooring, n—resilient flooring which has
adhesive under the entire product, bonding it to the underlay-
ment surface (see Practice F1482).
1
This practice is under the jurisdiction of ASTM Committee F06 on Resilient
Floor Coverings and is the direct responsibility of Subcommittee F06.40 on
2
Practices. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved Feb. 1, 2019. Published March 2019. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
approvedin2005asF2471-05.Lastpreviouseditionapprovedin2013asF2471-13. Standards volume information, refer to the standard’s Document Summary page on
DOI: 10.1520/F2471-19. the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F2471 − 19
3.2.2 non-fully adhered flooring, n—resilient floor
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: F2471 − 13 F2471 − 19
Standard Practice for
Installation of Thick Poured Lightweight Cellular Concrete
Underlayments and Preparation of the Surface to Receive
1
Resilient Flooring
This standard is issued under the fixed designation F2471; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This practice covers the installation and preparation of the thick poured lightweight cellular concrete underlayments over
wood structural panel subfloors in commercial structures or over concrete floors in commercial structures and the preparation of
the thick poured lightweight cellular concrete underlayment surface prior to the installation of resilient flooring in commercial
buildings.
1.2 This practice points out the factors that are required to be controlled while installing thick poured lightweight cellular
concrete underlayment as a base for resilient flooring.
1.3 This practice does not cover the structural adequacy of the wood structural panel subfloor or concrete subfloor. The
structural integrity of assemblies is governed by local building codes.
1.4 This practice does not supercede the thick poured lightweight cellular concrete underlayment manufacturers’, adhesive
manufacturers’ or resilient flooring manufacturers’ written instructions. Consult the individual manufacturer for specific
recommendations.
1.5 Thick poured lightweight cellular concrete underlayments are not suitable for use on concrete slabs on ground due to
potential moisture problems arising from moisture intrusion, unless an adequate vapor retarder or vapor barrier is present directly
beneath the concrete subfloor.
1.6 The values stated in inch-pound units are to be regarded as standard. The values stated in parentheses are mathematical
conversions to SI Units, which are provided for information only.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
C330 Specification for Lightweight Aggregates for Structural Concrete
C796 Test Method for Foaming Agents for Use in Producing Cellular Concrete Using Preformed Foam
C869 Specification for Foaming Agents Used in Making Preformed Foam for Cellular Concrete
F141 Terminology Relating to Resilient Floor Coverings
F710 Practice for Preparing Concrete Floors to Receive Resilient Flooring
F1482 Practice for Installation and Preparation of Panel Type Underlayments to Receive Resilient Flooring
F2170 Test Method for Determining Relative Humidity in Concrete Floor Slabs Using in situ Probes
F1482 Practice for Installation and Preparation of Panel Type Underlayments to Receive Resilient Flooring
1
This practice is under the jurisdiction of ASTM Committee F06 on Resilient Floor Coverings and is the direct responsibility of Subcommittee F06.40 on Practices.
Current edition approved May 1, 2013Feb. 1, 2019. Published June 2013March 2019. Originally approved in 2005 as F2471-05. Last previous edition approved in
20082013 as F2471-08.-13. DOI: 10.1520/F2471-13.10.1520/F2471-19.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F2471 − 19
F2678 Practice for Preparing Panel Underlayments, Thick Poured Gypsum Concrete Underlayments, Thick Poured Lightweight
Cellular Concrete Underlayments, and Concrete Subfloors with Underlayment Patching Compounds to Receive Resilient
Flooring
3. Terminology
3.1 Definitions used in this practice shall be
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.