Water quality - Determination of dissolved bromate - Method using ion chromatography (IC) and post column reaction (PCR) (ISO 11206:2011)

ISO 11206:2011 specifies a method for the determination of dissolved bromate in water (e.g. drinking water, mineral water, raw water, surface water, partially treated water or swimming pool water).
Appropriate pretreatment of the sample (e.g. dilution) allows determination of bromate at concentrations ³0,5 µg/l.
The working range is restricted by the ion‑exchange capacity of the separator column. Dilution of the sample to the bromate working range can be necessary.

Wasserbeschaffenheit - Bestimmung von gelöstem Bromat - Verfahren mittels Ionenchromatographie (IC) und Nachsäulenreaktion (PCR) (ISO 11206:2011)

Diese Internationale Norm legt ein Verfahren zur Bestimmung von gelöstem Bromat in Wasser (z. B. Trinkwasser, Mineralwasser, Rohwasser, Oberflächenwasser, teilweise behandeltes Wasser oder Badewasser) fest.
Eine geeignete Probenvorbehandlung (z. B. Verdünnung) erlaubt die Bestimmung von Bromatkonzentrationen ≥ 0,5 µg/l.
Der Arbeitsbereich ist durch die Kapazität der Trennsäule begrenzt. Eine Probenverdünnung in den Arbeitsbereich kann erforderlich sein.

Qualité de l'eau - Dosage du bromate dissous - Méthode utilisant la chromatographie ionique (IC) et la réaction post-colonne (PCR) (ISO 11206:2011)

L'ISO 11206:2011 spécifie une méthode pour le dosage du bromate dissous dans l'eau (par exemple l'eau potable, l'eau minérale, l'eau brute, les eaux de surface, l'eau partiellement traitée ou l'eau de piscine).
Le prétraitement approprié de l'échantillon (par exemple dilution) permet de doser le bromate à des concentrations supérieures ou égales à 0,5 µg/l.
Le domaine de travail est limité à la capacité d'échange ionique de la colonne de séparation. Il peut être nécessaire de diluer l'échantillon dans le domaine de travail du bromate.

Kakovost vode - Določevanje raztopljenega bromata - Metoda z ionsko kromatografijo in pokolonsko reakcijo (PCR) (ISO 11206:2011)

Ta mednarodni standard določa metodo za določevanje raztopljenega bromata v vodi (npr. pitna, mineralna, surova, površinska, delno pripravljena ali bazenska voda). Ustrezna predpriprava vzorca (npr. redčenje) omogoča določevanje bromata pri koncentraciji   0,5 μg/l.  Delovni obseg je omejen z zmogljivostjo ionske izmenjave separatorske kolone. Morda je potrebno redčenje vzorca do delovnega obsega bromata.

General Information

Status
Published
Publication Date
12-Mar-2013
Withdrawal Date
29-Sep-2013
Technical Committee
Drafting Committee
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
13-Mar-2013
Due Date
10-Oct-2013
Completion Date
13-Mar-2013

Buy Standard

Standard
EN ISO 11206:2013
English language
22 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN ISO 11206:2013
01-julij-2013
.DNRYRVWYRGH'RORþHYDQMHUD]WRSOMHQHJDEURPDWD0HWRGD]LRQVNR
NURPDWRJUDILMRLQSRNRORQVNRUHDNFLMR 3&5  ,62
Water quality - Determination of dissolved bromate - Method using ion chromatography
(IC) and post column reaction (PCR) (ISO 11206:2011)
Wasserbeschaffenheit - Bestimmung von gelöstem Bromat - Verfahren mittels
Ionenchromatographie (IC) und Nachsäulenreaktion (PCR) (ISO 11206:2011)
Qualité de l'eau - Détermination du bromate dissous - Méthode utilisant la
chromatographie ionique (IC) et la réaction post-colonne (PCR) (ISO 11206:2011)
Ta slovenski standard je istoveten z: EN ISO 11206:2013
ICS:
13.060.50 3UHLVNDYDYRGHQDNHPLþQH Examination of water for
VQRYL chemical substances
SIST EN ISO 11206:2013 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN ISO 11206:2013

---------------------- Page: 2 ----------------------

SIST EN ISO 11206:2013


EUROPEAN STANDARD
EN ISO 11206

NORME EUROPÉENNE

EUROPÄISCHE NORM
March 2013
ICS 13.060.50
English Version
Water quality - Determination of dissolved bromate - Method
using ion chromatography (IC) and post column reaction (PCR)
(ISO 11206:2011)
Qualité de l'eau - Détermination du bromate dissous - Wasserbeschaffenheit - Bestimmung von gelöstem Bromat
Méthode utilisant la chromatographie ionique (IC) et la - Verfahren mittels Ionenchromatographie (IC) und
réaction post-colonne (PCR) (ISO 11206:2011) Nachsäulenreaktion (PCR) (ISO 11206:2011)
This European Standard was approved by CEN on 10 February 2013.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2013 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 11206:2013: E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN ISO 11206:2013
EN ISO 11206:2013 (E)
Contents Page
Foreword . 3

2

---------------------- Page: 4 ----------------------

SIST EN ISO 11206:2013
EN ISO 11206:2013 (E)
Foreword
The text of ISO 11206:2011 has been prepared by Technical Committee ISO/TC 147 “Water quality” of the
International Organization for Standardization (ISO) and has been taken over as EN ISO 11206:2013 by
Technical Committee CEN/TC 230 “Water analysis” the secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by September 2013, and conflicting national standards shall be
withdrawn at the latest by September 2013.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
Endorsement notice
The text of ISO 11206:2011 has been approved by CEN as EN ISO 11206:2013 without any modification.